Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.1(2)
Viewing Server Properties
Downloads: This chapterpdf (PDF - 392.0KB) The complete bookPDF (PDF - 1.25MB) | Feedback

Viewing Server Properties

Viewing Server Properties

This chapter includes the following sections:

Viewing CPU Properties

Before You Begin

The server must be powered on, or the properties will not display.


Procedure
  Command or Action Purpose
Step 1 Server# scope chassis  

Enters chassis command mode.

 
Step 2 Server /chassis # show cpu [detail] 

Displays CPU properties.

 

This example displays CPU properties:

Server# scope chassis
Server /chassis # show cpu
Name         Cores    Version                                            
------------ -------- -------------------------------------------------- 
CPU1         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
CPU2         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    

Server /chassis #  

Viewing Memory Properties

Before You Begin

The server must be powered on, or the properties will not display.


Procedure
  Command or Action Purpose
Step 1 Server# scope chassis  

Enters chassis command mode.

 
Step 2 Server /chassis # show dimm [detail] 

Displays memory properties.

 

This example displays memory properties:

Server# scope chassis
Server /chassis # show dimm
Name       Capacity (MB)   Speed (MHz)     Type            
---------- --------------- --------------- --------------- 
DIMM_A1    2048            1067            Other           
DIMM_A2    0               1067            Other           
DIMM_B1    0               1067            Other           
DIMM_B2    0               1067            Other           
DIMM_C1    0               1067            Other           
DIMM_C2    0               1067            Other           
DIMM_D1    2048            1067            Other           
DIMM_D2    0               1067            Other           
DIMM_E1    0               1067            Other           
DIMM_E2    0               1067            Other           
DIMM_F1    0               1067            Other           
DIMM_F2    0               1067            Other 
  
Server /chassis #  

Viewing Power Supply Properties

Before You Begin

The server must be powered on, or the properties will not display.


Procedure
  Command or Action Purpose
Step 1 Server# scope chassis  

Enters chassis command mode.

 
Step 2 Server /chassis # show psu [detail] 

Displays power supply properties.

 

This example displays power supply properties:

Server# scope chassis
Server /chassis # show psu
Name       In. Power (Watts)    Out. Power (Watts)   Firmware  Status     
---------- -------------------- -------------------- -------- ---------- 
PSU1       74                   650                  R0E      Present    
PSU2       83                   650                  R0E      Present    

Server /chassis #  

Viewing Storage Properties

Before You Begin

The server must be powered on, or the properties will not display.


Procedure
  Command or Action Purpose
Step 1 Server# scope chassis  

Enters chassis command mode.

 
Step 2 Server /chassis # show hdd [detail] 

Displays storage properties.

 

This example displays storage properties:

Server# scope chassis
Server /chassis # show hdd
Name                 Status               
-------------------- -------------------- 
HDD_01_STATUS        present              
HDD_02_STATUS        present              
HDD_03_STATUS        present              
HDD_04_STATUS        present 

Server /chassis #