Guest

Cisco TelePresence MCU 4200 Series

HD resolutions not sent to MXP endpoint when motion/sharpness trade off set to balanced

My Cisco acquired Codian/TANDBERG product does not send HD resolutions to my Cisco TelePresence System MXP endpoint when the Motion/sharpness trade off is set to Balanced. What shall I do?

To send 720p 30fps to MXPs, set your Cisco acquired Codian/TANDBERG product's Motion / sharpness tradeoff to Favor sharpness or configure your MXPs as pre-configured endpoints with the Motion / sharpness tradeoff set to Favor sharpness.

For more information about pre-configuring endpoints, refer to the online help topic, Configuring H.323 endpoints.

This article applies to the following products:

  • Cisco TelePresence MCU 4200 / MSE 8420
  • Cisco TelePresence MCU 4500
  • Cisco TelePresence MSE 8510 blade
  • Cisco TelePresence Advanced Media Gateway 3600