Cisco Nexus 6000 Series Hardware Installation Guide
Technical Specifications
Downloads: This chapterpdf (PDF - 134.0KB) The complete bookPDF (PDF - 2.47MB) | Feedback

Technical Specifications

Table Of Contents

Technical Specifications

Switch Specifications

Environmental Specifications

Expansion Module Specifications

Power Specifications

Specifications for the Cisco Nexus 6001 Power Supply

Specifications for the Cisco Nexus 6004 Power Supply


Technical Specifications


This appendix describes the technical specifications for the Cisco Nexus 6000 switch.

This appendix includes the following sections:

Switch Specifications

Environmental Specifications

Expansion Module Specifications

Power Specifications


Note Specifications for cables and connectors are provided in "Cable and Port Specifications."


Switch Specifications

Table B-1 lists the physical specifications for the Cisco Nexus 6001 switch.

Table B-1 Physical Specifications for the Cisco Nexus 6001Switch

Description
Specification

Dimensions (H x W x D)

1.75 inches (4.4 cm) tall, 17.3 inches (43.9 cm) wide, and 30 inches (76.2 cm) deep

Cisco Nexus 6001

31.5lbs


Table B-2 lists the physical specifications for the Cisco Nexus 6004 switch.

Table B-2 Physical Specifications for the Cisco Nexus 6004Switch

Description
Specification

Dimensions (H x W x D)

(17.7 cm) tall, 17.3 inches (43.9 cm) wide, and 30 inches (76.2 cm) deep

Cisco Nexus 6004 with three 1100W power supplies, four expansion modules, and four fan modules

122 lb

Cisco Nexus 6004 with three 1100W power supplies and four fan modules

100 lb


Environmental Specifications

Table B-3 lists the environmental specifications for the Cisco Nexus 6001switch.

Table B-3 Environmental Specifications for the Cisco Nexus 6001switch

Property
Cisco Nexus 6001Switch

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating (storage) temperature

-40 to 158°F (-40 to 70°C)

Humidity

5 to 95% (noncondensing)

Altitude

0 to 10,000 ft (0 to 3000 m)


Table B-4 lists the environmental specifications for the Cisco Nexus 6004 switch.

Table B-4 Environmental Specifications for the Cisco Nexus 6004 switch

Property
Cisco Nexus 6004Switch

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating (storage) temperature

-40 to 158°F (-40 to 70°C)

Humidity

5 to 95% (noncondensing)

Altitude

0 to 10,000 ft (0 to 3000 m)


Expansion Module Specifications

Table B-5 lists the physical specifications for the Cisco Nexus 6004 switch expansion module.

Table B-5 Physical Specifications for the Cisco Nexus 6004 Switch Expansion Module

Description
Specification

Weight

1 lb (0.5 kg)


Power Specifications

This section describes the power specifications for the Cisco Nexus 6000 Series switches. This section includes the following topics:

Specifications for the Cisco Nexus 6001 Power Supply

Specifications for the Cisco Nexus 6004 Power Supply

Specifications for the Cisco Nexus 6001 Power Supply

Table B-6 lists the power supply properties of the Cisco Nexus 6001 platform.

Table B-6 Specifications for the Cisco Nexus 6001Power Supply

AC Power Supply Properties
Specification

Typical operating power

750W

Maximum power

1100W

Input voltage

94 to 240 VAC

Frequency

47 to 63 Hz

Efficiency

94% (at 50% load)

RoHS compliance

Yes

Hot swappable

Yes

Front-to-back air flow power supply

Yes

Back-to-front air flow power supply

Yes


Specifications for the Cisco Nexus 6004 Power Supply

Table B-7 lists the power supply properties of the Cisco Nexus 6004 platform.

Table B-7 Specifications for the Cisco Nexus 6004 Power Supply

AC Power Supply Properties
Specification

Typical operating power

2800 W

Maximum power

3300 W

Input voltage

94 to 240 VAC

Frequency

47 to 63Hz

Efficiency

98% (50 to 100% load)

RoHS compliance

Yes

Hot swappable

Yes

Heat dissipation

11260 BTU/hr (3300W)

Front-to-back air flow power supply

Yes

Back-to-front air flow power supply

Yes