Cable and Port Specifications
This appendix provides cable and port specifications for all of the Cisco Nexus 5000 Series switches.
This appendix includes the following sections:
Console Cable
Note This section applies to the Cisco Nexus 5000 Series switches.
The console cable has a RJ-45, RS-232 connector on one end and a DB9 connector on the other end. See Figure C-1.
Figure C-1 Console Cable
Cable RJ-45 Connector Pinouts
Table C-1 lists the pinouts for the RJ-45 connector on the console cable.
Table C-1 Cable Connector Pinouts
|
|
|
|
RTS |
1 |
8 |
CTS |
DTR |
2 |
6 |
DSR |
TXD |
3 |
2 |
ZXD |
GND |
4 |
5 |
GND |
GND |
5 |
5 |
GND |
ZXD |
6 |
3 |
TXD |
DSR |
7 |
4 |
DTR |
CTS |
8 |
7 |
RTS |
Console Port
Note This section applies to the Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Platform switches.
The console port is an asynchronous RS-232 serial port with an RJ-45 connector.
Console Port Pinouts
Table C-2 lists the pinouts for the console port on the Cisco Nexus 5548 switch and the Cisco Nexus 5020 switch.
Table C-2 Console Port Pinouts for the Cisco Nexus 5548 Switch and the Cisco Nexus 5020 Switch
|
|
1 |
RTS |
2 |
DTR |
3 |
TxD |
4 |
GND |
5 |
GND |
6 |
RxD |
7 |
DSR |
8 |
CTS |
Table C-3 lists the pinouts for the console port on the Cisco Nexus 5010 switch.
Table C-3 Console Port Pinouts for the Cisco Nexus 5010 Switch
|
|
1 |
RTS |
2 |
DTR |
3 |
TxD |
4 |
GND |
5 |
GND |
6 |
RxD |
7 |
DSR |
8 |
CTS |
Supported Power Cords and Plugs
Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit that has IEC 60320 C19 outlet receptacles. The standard power cords have an IEC C13 connector on the end that plugs into the switch. The optional jumper power cords, for use in cabinets, have an IEC C13 connector on the end that plugs into the switch and an IEC C14 connector on the end that plugs into an IEC C13 outlet receptacle.
Note Only the regular power cords or jumper power cords provided with the switch are supported.
Note If you do not order the optional power cord with the system, you are responsible for selecting the appropriate power cord for the product. Using a non-compatible power cord with this product may result in electrical safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered with the system.
Table C-4 lists the power cords and provides their lengths in feet and meters. Table C-5 lists the power cables for the HVAC/HVDC power supplies (NXA-PHV-1100W and NXA-PHV-1100W-B) that are available for the Cisco Nexus 5596 switch.
Table C-4 Power Cords for the Cisco Nexus 5000 Series Switches
|
|
Power Cord Reference Illustration
|
|
|
CAB-250V-10A-AR Power cord 250 VAC 10 A, IRAM 2073 plug Argentina |
8.2 |
2.5 |
Figure C-2 |
CAB-9K10A-AU Power cord 250 VAC 10 A, 3112 plug, Australia |
8.2 |
2.5 |
Figure C-3 |
CAB-250V-10A-CN Power cord 250 VAC 10 A, GB 2009 plug China |
8.2 |
2.5 |
Figure C-4 |
CAB-9K10A-EU Power cord, 250 VAC 10 A, M 2511 plug Europe |
8.2 |
2.5 |
Figure C-5 |
CAB-250V-10A-ID Power cord 250 VAC 16A, EL-208 plug South Africa, United Arab Emirates, India |
8.2 |
2.5 |
Figure C-6 |
CAB-250V-10A-IS Power cord 250 VAC 10 A, SI-32 plug Israel |
8.2 |
2.5 |
Figure C-7 |
CAB-9K10A-IT Power cord 250 VAC 10 A, CEI 23-16 plug Italy |
8.2 |
2.5 |
Figure C-8 |
CAB-9K10A-SW Power cord 250 VAC 10 A, MP232 plug Switzerland |
8.2 |
2.5 |
Figure C-9 |
CAB-9K10A-UK Power cord 250 VAC 10 A, BS1363 plug (13 A fuse) United Kingdom |
8.2 |
2.5 |
Figure C-10 |
CAB-AC-250V/13A Power cord 250 VAC 13 A, NEMA L6-20 plug North America |
6.6 |
2.0 |
Figure C-11 |
CAB-N5K6A-NA Power cord 250 VAC 10 A, NEMA 6-15 plug North America |
8.2 |
2.5 |
Figure C-12 |
CAB-9K12A-NA Power cord 125 VAC 13 A, NEMA 5-15 plug North America |
8.2 |
2.5 |
Figure C-13 |
CAB-C13-CBN Power cord 250 VAC 10 A, SS 10A plug |
8.2 |
2.5 |
Figure C-14 |
CAB-IND-10A Power cord 250 VAC 10 A, EL 208B plug |
8.2 |
2.5 |
Figure C-15 |
CAB-C13-C14-JMPR Cabinet Jumper Power Cord 250 VAC 13 A, C13-C14 Connectors |
2.2 |
0.7 |
Figure C-16 |
Figure C-2 CAB-250V-10A-AR
Figure C-3 CAB-9K10A-AU
Figure C-4 CAB-250V-10A-CN
Figure C-5 CAB-9K10A-EU
Figure C-6 CAB-250V-10A-ID
Figure C-7 CAB-250V-10A-IS
Figure C-8 CAB-9K10A-IT
Figure C-9 CAB-9K10A-SW
Figure C-10 CAB-9K10A-UK
Figure C-11 CAB-AC-250V/13A
Figure C-12 CAB-N5K6A-NA
Figure C-13 CAB-9K12A-NA
Figure C-14 CAB-C13-CBN
Figure C-15 CAB-IND-10A
Table C-5 Power Cable Specifications for HVAC/HVDC Power Supplies
|
|
|
HVAC |
CAB-HVAC-SD-0.6M |
2-foot (0.6 m) cable with Saf-D-Grid and SD connectors (LS-25 straight) |
HVAC |
CAB-HVAC-C14-2M |
6.6-foot (2.0 m) cable with Saf-D-Grid and C14 connector (use for up to 240 V) |
HVAC |
CAB-HVAC-RT-0.6M |
2-foot (0.6 m) cable with Saf-D-Grid and RT connector (LS-25 right angle) |
HVDC |
CAB-HVDC-3T-2M |
6.6-foot (2.0 m) cable with Saf-D-Grid and three terminal connectors |
Jumper Power Cord
Figure C-16 shows the plug connector on the optional jumper power cord for the Cisco Nexus 5000 Series switches. This cable plugs into the power supply, and the receptacle of a power distribution unit for a cabinet. This cable comes in 6- and 9-foot (2- and 3-meter) lengths.
Figure C-16 CAB-C13-C14-JMPR, Jumper Power Cord