R Commands
This chapter describes the Cisco Nexus 1000V commands that begin with the letter R.
radius-server deadtime
To configure the dead-time interval for all RADIUS servers used by a device, use the
radius-server deadtime
command. To revert to the default, use the
no
form of this command.
radius-server deadtime
minutes
no radius-server
deadtime
minutes
Syntax Description
minutes
|
Number of minutes for the dead-time interval. The range is from 1 to 1440 minutes.
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
The dead-time interval is the number of minutes before the device checks a RADIUS server that was previously unresponsive.
Note The default idle timer value is 0 minutes. When the idle time interval is 0 minutes, periodic RADIUS server monitoring is not performed.
Examples
This example shows how to configure the global dead-time interval for all RADIUS servers to perform periodic monitoring:
n1000v(config)# radius-server deadtime 5
This example shows how to revert to the default for the global dead-time interval for all RADIUS servers and disable periodic server monitoring:
n1000v(config)# no radius-server deadtime 5
Related Commands
|
|
show radius-server
|
Displays RADIUS server information.
|
radius-server directed-request
To allow users to send authentication requests to a specific RADIUS server when logging in, use the
radius-server directed request
command. To revert to the default, use the
no
form of this command.
radius-server directed-request
no
radius-server directed-request
Syntax Description
This command has no arguments or keywords.
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
You can specify the
username
@
vrfname
:
hostname
during login, where vrfname is the virtual routing and forwarding (VRF) instance to use and hostname is the name of a configured RADIUS server. The username is sent to the RADIUS server for authentication.
Examples
This example shows how to allow users to send authentication requests to a specific RADIUS serve when logging in:
n1000v(config)# radius-server directed-request
This example shows how to disallow users to send authentication requests to a specific RADIUS server when logging in:
n1000v(config)# no radius-server directed-request
Related Commands
|
|
show radius-server directed-request
|
Displays the directed request RADIUS server configuration.
|
radius-server host
To configure RADIUS server parameters, use the
radius-server host
command. To revert to the default, use the
no
form of this command.
radius-server host
{
hostname | ipv4-address | ipv6-address
}
[
key
[
0
|
7
]
shared-secret
[
pac
]] [
accounting
]
[
acct-port
port-number
] [
auth-port
port-number
] [
authentication
] [
retransmit
count
]
[
test
{
idle-time
time
|
password
password
|
username
name
}]
[
timeout
seconds
[
retransmit
count
]]
no radius-server host
{
hostname | ipv4-address | ipv6-address
}
[
key
[
0
|
7
]
shared-secret
[
pac
]] [
accounting
]
[
acct-port
port-number
] [
auth-port
port-number
] [
authentication
] [
retransmit
count
]
[
test
{
idle-time
time
|
password
password
|
username
name
}]
[
timeout
seconds
[
retransmit
count
]]
Syntax Description
hostname
|
RADIUS server Domain Name Server (DNS) name. The name is alphanumeric, case sensitive, and has a maximum of 256 characters.
|
ipv4-address
|
RADIUS server IPv4 address in the
A
.
B
.
C
.
D
format.
|
ipv6-address
|
RADIUS server IPv6 address in the
X
:
X
:
X
::
X
format.
|
key
|
(Optional) Configures the RADIUS server preshared secret key.
|
0
|
(Optional) Configures a preshared key specified in clear text to authenticate communication between the RADIUS client and server. This is the default.
|
7
|
(Optional) Configures a preshared key specified in encrypted text (indicated by 7) to authenticate communication between the RADIUS client and server.
|
shared-secret
|
Preshared key to authenticate communication between the RADIUS client and server. The preshared key can include any printable ASCII characters (white spaces are not allowed), is case sensitive, and has a maximum of 63 characters.
|
pac
|
(Optional) Enables the generation of Protected Access Credentials (PAC) on the RADIUS Cisco Access Control Server (ACS) for use with Cisco TrustSec.
|
accounting
|
(Optional) Configures accounting.
|
acct-port
port-number
|
(Optional) Configures the RADIUS server port for accounting. The range is from 0 to 65535.
|
auth-port
port-number
|
(Optional) Configures the RADIUS server port for authentication. The range is from 0 to 65535.
|
authentication
|
(Optional) Configures authentication.
|
retransmit
count
|
(Optional) Configures the number of times that the device tries to connect to a RADIUS server(s) before reverting to local authentication. The range is from 1 to 5 times and the default is 1 time.
|
test
|
(Optional) Configures parameters to send test packets to the RADIUS server.
|
idle-time
time
|
Specifies the time interval (in minutes) for monitoring the server. The range is from 1 to 1440 minutes.
|
password
password
|
Specifies a user password in the test packets. The password is alphanumeric, case sensitive, and has a maximum of 32 characters.
|
username
name
|
Specifies a username in the test packets. The is alphanumeric, not case sensitive, and has a maximum of 32 characters.
|
timeout
seconds
|
Specifies the timeout (in seconds) between retransmissions to the RADIUS server. The default is 5 seconds and the range is from 1 to 60 seconds.
|
Defaults
|
|
Accounting port
|
1813
|
Authentication port
|
1812
|
Accounting
|
enabled
|
Authentication
|
enabled
|
Retransmission count
|
1
|
Idle-time
|
none
|
Server monitoring
|
disabled
|
Timeout
|
5 seconds
|
Test username
|
test
|
Test password
|
test
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
When the idle time interval is 0 minutes, periodic RADIUS server monitoring is not performed.
Examples
This example shows how to configure RADIUS server authentication and accounting parameters:
n1000v(config)# radius-server host 10.10.2.3 key HostKey n1000v(config)# radius-server host 10.10.2.3 auth-port 2003 n1000v(config)# radius-server host 10.10.2.3 acct-port 2004 n1000v(config)# radius-server host 10.10.2.3 accounting n1000v(config)# radius-server host radius2 key 0 abcd n1000v(config)# radius-server host radius3 key 7 1234 n1000v(config)# radius-server host 10.10.2.3 test idle-time 10 n1000v(config)# radius-server host 10.10.2.3 test username tester n1000v(config)# radius-server host 10.10.2.3 test password 2B9ka5
Related Commands
|
|
show radius-server
|
Displays RADIUS server information.
|
radius-server key
To configure a RADIUS shared secret key, use the
radius-server key
command. To remove a configured shared secret, use the
no
form of this command.
radius-server key
[
0
|
7
]
shared-secret
no
radius-server key
[
0
|
7
]
shared-secret
Syntax Description
0
|
(Optional) Configures a preshared key specified in clear text to authenticate communication between the RADIUS client and server.
|
7
|
(Optional) Configures a preshared key specified in encrypted text to authenticate communication between the RADIUS client and server.
|
shared-secret
|
Preshared key used to authenticate communication between the RADIUS client and server. The preshared key can include any printable ASCII characters (white spaces are not allowed), is case sensitive, and has a maximum of 63 characters.
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
You must configure the RADIUS preshared key to authenticate the switch on the RADIUS server. The length of the key is restricted to 63 characters and can include any printable ASCII characters (white spaces are not allowed). You can configure a global key to be used for all RADIUS server configurations on the switch. You can override this global key assignment for an individual host by using the
key
keyword in the
radius-server host
command.
Examples
This example shows how to provide various scenarios to configure RADIUS authentication:
n1000v(config)# radius-server key AnyWord n1000v(config)# radius-server key 0 AnyWord n1000v(config)# radius-server key 7 public pac
Related Commands
|
|
show radius-server
|
Displays RADIUS server information.
|
radius-server retransmit
To specify the number of times that the device should try a request with a RADIUS server, use the
radius-server retransmit
command. To revert to the default, use the
no
form of this command.
radius-server retransmit
count
no radius-server retransmit
count
Syntax Description
count
|
Number of times that the device tries to connect to a RADIUS server(s) before reverting to local authentication. The range is from 1 to 5 times.
|
Defaults
1 retransmission
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to configure the number of retransmissions to RADIUS servers:
n1000v(config)# radius-server retransmit 3
This example shows how to revert to the default number of retransmissions to RADIUS servers:
n1000v(config)# no radius-server retransmit 3
Related Commands
|
|
show radius-server
|
Displays RADIUS server information.
|
radius-server timeout
To specify the time between retransmissions to the RADIUS servers, use the
radius-server timeout
command. To revert to the default, use the
no
form of this command.
radius-server timeout
seconds
no radius-server timeout
seconds
Syntax Description
seconds
|
Number of seconds between retransmissions to the RADIUS server. The range is from 1 to 60 seconds.
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to configure the timeout interval:
n1000v(config)# radius-server timeout 30
This example shows how to revert to the default interval:
n1000v(config)# no radius-server timeout 30
Related Commands
|
|
show radius-server
|
Displays RADIUS server information.
|
rate-mode dedicated
To set the dedicated rate mode for the specified ports, use the
rate-mode dedicated
command.
rate-mode dedicated
no rate-mode
Syntax Description
This command has no arguments or keywords.
Command Default
Shared rate mode is the default.
Command Modes
Interface configuration (config-if)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
Use the rate-mode dedicated command to set the dedicated rate mode for the specified ports.
On a 32-port 10-Gigabit Ethernet module, each set of four ports can handle 10 gigabits per second (Gb/s) of bandwidth. You can use the rate-mode parameter to dedicate that bandwidth to the first port in the set of four ports or share the bandwidth across all four ports.
Note When you dedicate the bandwidth to one port, you must first administratively shut down the ports in the group, change the rate mode to dedicated, and then bring the dedicated port administratively up.
Table 1-1
identifies the ports that are grouped together to share each 10 Gb/s of bandwidth and which port in the group can be dedicated to utilize the entire bandwidth.
Table 1-1 Dedicated and Shared Ports
Ports Groups that Can Share Bandwidth
|
Ports that Can be Dedicated to Each 10-Gigabit Ethernet of Bandwidth
|
1, 3, 5, 7
|
1
|
2, 4, 6, 8
|
2
|
9, 11, 13, 15
|
9
|
10, 12, 14, 16
|
10
|
17, 19, 21, 23
|
17
|
18, 20, 22, 24
|
18
|
25, 27, 29, 31
|
25
|
26, 28, 30, 32
|
26
|
When you enter the
rate-mode dedicated
command, the full bandwidth of 10 Gb is dedicated to one port. When you dedicate the bandwidth, all subsequent commands for the port are for dedicated mode.
Examples
This example shows how to configure the dedicated rate mode for Ethernet ports 4/17, 4/19, 4/21, and 4/23:
n1000v(config)# interface ethernet 4/17, ethernet 4/19, ethernet 4/21, ethernet 4/23 n1000v(config-if)# shutdown n1000v(config-if)# interface ethernet 4/17 n1000v(config-if)# rate-mode dedicated n1000v(config-if)# no shutdown
Related Commands
|
|
show interface
|
Displays interface information, which includes the current rate mode dedicated.
|
record
To configure a NetFlow flow record, use the
record
command. To remove the flow record configuration, use the
no
form of the command.
record {name
|
netflow ipv4
{
original-input
|
original-output
| netflow
protocol-port
} |
netflow-original
}
no record {name
|
netflow ipv4
{
original-input
|
original-output
| netflow
protocol-port
} |
netflow-original
}
Syntax Description
name
|
Specifies the name of a new NetFlow flow record.
|
netflow ipv4
|
Specifies a predefined NetFlow flow record that uses traditional IPv4 NetFlow collection schemes.
|
original-input
|
Specifies a predefined NetFlow flow record that uses traditional IPv4 input.
|
original-output
|
Specifies a predefined NetFlow flow record that uses traditional IPv4 output.
|
netflow protocol-port
|
Specifies the NetFlow flow record that uses the protocol and ports aggregation scheme.
|
netflow-original
|
Specifies a NetFlow flow record that uses traditional IPv4 input with origin ASs.
|
Command Modes
Flow monitor configuration (config-flow-monitor)
network-admin
Command History
|
|
4.2(1)SV1(4)
|
This command was modified to change the protocol-port attribute to netflow protocol-port.
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
A flow record defines the information that NetFlow gathers, such as packets in the flow and the types of counters gathered per flow. You can define new flow records or use the pre-defined flow record.
Examples
This example shows how to configure a flow record to use a the predefined traditional IPv4 input NetFlow record:
n1000v(config)# flow monitor testmon n1000v(config-flow-monitor)# record netflow ipv4 original-input n1000v(config-flow-monitor)#
This example shows how to remove the predefined traditional IPv4 input NetFlow flow record configuration:
n1000v(config)# flow monitor testmon n1000v(config-flow-monitor)# no record netflow ipv4 original-input n1000v(config-flow-monitor)#
Related Commands
|
|
show flow monitor
|
Displays NetFlow monitor configuration information.
|
show flow record
|
Displays NetFlow record configuration information.
|
reload
To reboot both the primary and secondary VSM in a redundant pair, use the
reload
command.
reload
Syntax Description
This command has no arguments or keywords.
Command Modes
Any
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
To reboot only one of the VSMs in a redundant pair, use the
reload module
command instead.
Before reloading, use the
copy running-configuration to startup-configuration
command to preserve any configuration changes made since the previous reboot or restart.
Examples
This example shows how to reload both the primary and secondary VSM:
!!!WARNING! there is unsaved configuration!!! This command will reboot the system. (y/n)? [n] y 2010 Sep 3 11:33:35 bl-n1000v %PLATFORM-2-PFM_SYSTEM_RESET: Manual system restart from Command Line Interface
Related Commands
|
|
reload module
|
Reloads the specified VSM (1 or 2) in a redundant pair.
|
reload module
To reload one of the VSMs in a redundant pair, use the
reload module
command.
reload module module
[
force-dnld
]
Syntax Description
module
|
The module number:
-
1 (primary VSM)
-
2 (secondary VSM)
|
force-dnld
|
(Optional) Reboots the specified module to force NetBoot and image download.
|
Command Modes
Any
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
To reboot both the VSMs in a redundant pair, use the
reload
command instead.
Before reloading, use the
copy running-configuration to startup-configuration
command to preserve any configuration changes made since the previous reboot or restart.
Examples
This example shows how to reload VSM 2, the secondary VSM in a redundant pair:
!!!WARNING! there is unsaved configuration!!! This command will reboot the system. (y/n)? [n] y 2010 Sep 3 11:33:35 bl-n1000v %PLATFORM-2-PFM_SYSTEM_RESET: Manual system restart from Command Line Interface
Related Commands
|
|
show version
|
Displays information about the software version.
|
reload
|
Reboots both the primary and secondary VSM.
|
remote
To connect to remote machines, use the
remote
command. To disconnect, use the
no
form of this command.
remote
{
ip
address
address
|
hostname
name
}
no
remote
{
ip
address
address
|
hostname
name
}
Syntax Description
ipaddress
|
Specifies an IP address.
|
address
|
IPv4 address. The format is A.B.C.D.
|
hostname
|
Specifies the remote host name.
|
name
|
Host name. The range of valid values is 1 to 128.
|
Command Modes
SVS connection configuration (config-svs-conn)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to connect to a remote machine:
n1000v#
configure terminaln1000v(config)#
svs connection svsconn1n1000v(config-svs-conn)#
remote hostname server1
Related Commands
|
|
show svs
|
Displays SVS information.
|
resequence
To resequence a list with sequence numbers, use the
resequence
command.
resequence
{{{ip | mac}
access-list
} |
time-range
}
name
number
increment
Syntax Description
ip
|
Indicates resequencing of an IP access-list.
|
mac
|
Indicates resequencing of a MAC access-list.
|
access-list
|
Indicates resequencing of an access list.
|
time-range
|
Indicates resequencing of a time-range.
|
name
|
(Optional) List name.
|
number
|
(Optional) Starting sequence number.
|
increment
|
(Optional) Step to increment the sequence number.
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to resequence the first entry in the MAC ACL named aclOne:
n1000v# configure terminal n1000v(config)# resequence mac access-list aclOne 1 2
Related Commands
|
|
show access-list
|
Displays ACLs.
|
rmdir
To remove a directory, use the
rmdir
command.
rmdir
[
filesystem
:
[
//
module
/
]]
directory
Syntax Description
filesystem
:
|
(Optional) Name of a file system. The name is case sensitive.
|
//
module
/
|
(Optional) Identifier for a supervisor module. Valid values are
sup-active
,
sup-local
,
sup-remote
, or
sup-standby
. The identifiers are case sensitive.
|
directory
|
Name of a directory. The name is case sensitive.
|
Defaults
Removes the directory from the current working directory.
Command Modes
Any
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to remove the my_files directory:
Related Commands
|
|
cd
|
Changes the current working directory.
|
dir
|
Displays the directory contents.
|
pwd
|
Displays the name of the current working directory.
|
role name
To create a user role, use the
role name
command. To remove the role, use the
no
form of this command.
role
name
role-
name
no
role
name
role-
name
Syntax Description
role-
name
|
Creates a user role of this name.
|
Command Modes
Global configuration (config)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to create a role named UserA:
n1000v(
config)#
role name UserA
This example shows how to remove the UserA role:
n1000v(
config)#
no role UserA
Related Commands
|
|
show role
|
Displays the available user roles and their rules.
|
interface policy
|
Denies users assigned to this role access to all interfaces unless specifically permitted.
|
permit interface
|
Specifies the interface(s) that users assigned to this role can access.
|
vlan policy
|
Denies users assigned to this role access to all VLANs unless specifically permitted.
|
permit vlan
|
Specifies the VLAN(s) that users assigned to this role can access.
|
rule
To create a rule defining criteria for a user role, use the
rule
command. To remove a rule, use the
no
form of this command.
rule
number
{
deny
|
permit
} {
read
|
read-write
[
feature
feature-name
|
feature-group
group-name
] |
command
command-name
}
no
rule
number
Syntax Description
number
|
Number that identifies this rule.
|
deny
|
Indicates that the user is denied the ability to perform a function.
|
permit
|
Indicates that the user is permitted to perform a function.
|
read
|
Specifies whether the assigned user has read access.
|
read-write
|
Specifies whether the assigned user has read-write access.
|
feature
|
(Optional) Specifies a feature for the rule.
|
feature-name
|
Name of an individual feature, such as syslog or TACACS+, whose access can be defined in this rule.
|
feature-group
|
(Optional) Specifies a feature type.
|
group-name
|
Grouping of features whose access can be defined in a rule.
|
command
|
Specifies a command for this rule.
|
command-
name
|
Single command, or group of commands collected in a regular expression, whose access can be defined in a rule.
|
Command Modes
Role configuration (config-role)
network-admin
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Usage Guidelines
The
rule number
specifies the order in which the rule is applied, in descending order. For example, if a role has three rules, rule 3 is applied first, rule 2 is applied next, and rule 1 is applied last. You can configure up to 256 rules for each role.
Examples
This example shows how to create a rule that denies access to the
clear users
command:
n1000v(config)# role name UserA n1000v(config-role)# rule 1 deny command clear users
This example shows how to remove the rule 1 configuration:
n1000v(config)# role name UserA n1000v(
config-role)#
no rule 1
Related Commands
|
|
username
|
Configures information about the user.
|
show role
|
Displays the user role configuration.
|
run-script
To run a command script that is saved in a file, use the
run-script
command.
run-script
{
bootflash:
|
volatile:
}
filename
Syntax Description
bootflash:
|
Indicates that the file containing the command script is located in the Bootflash file system.
|
volatile:
|
Indicates that the file containing the command script is located in the Volatile file system.
|
filename
|
The name of the file containing the command script. The name is case sensitive.
|
Command Modes
Any
network-admin
network-operator
Command History
|
|
4.0(4)SV1(1)
|
This command was introduced.
|
Examples
This example shows how to run a command script that is saved in the Sample file on the Volatile file system.
n1000v(
config)#
run-script volatile:Sample
Related Commands
|
|
cd
|
Changes the current working directory.
|
copy
|
Copies files.
|
dir
|
Displays the contents of the working directory.
|
pwd
|