Release Notes for Cisco ONS 15310-MA Release 7.0.4

Table Of Contents

Release Notes for Cisco ONS 15310-MA
Release 7.0.4

Contents

Changes to the Release Notes

Changes to Caveats

Caveats

Maintenance and Administration

CSCsc56694

Alarms

CSCse85355

CSCsd52665

CSCsd56328

Electrical IO Card

CSCsh17691

Common Control Cards

CSCsc52028

Alarms

CSCse85355

CSCsh20447

CSCsh22922

CSCsh20419

TL1

CSCsc51017

CSCsh24550

CSCsh21744

Resolved Caveats for Release 7.0.x

Maintenance and Administration

CSCsg17018

TL1

CSCsg22884

Electrical IO Cards

CSCsd59042

CSCsg23089

New Features and Functionality

Daylight Savings Time Support

Related Documentation

Release-Specific Documents

Platform-Specific Documents

Obtaining Documentation and Submitting a Service Request


Release Notes for Cisco ONS 15310-MA
Release 7.0.4


June 2008


Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


Release notes address closed (maintenance) issues, caveats, and new features for the Cisco ONS 15310-MA. For detailed information regarding features, capabilities, hardware, and software introduced with this release, refer to Release 7.0 of the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide, Cisco ONS 15310-CL and Cisco ONS 15310-MA Reference Manual, Cisco ONS SONET TL1 Command Guide, and the Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide. For the most current version of the Release Notes for Cisco ONS 15310-MA Release 7.0.4, visit the following URL:

http://www.cisco.com/en/US/products/hw/optical/ps2001/prod_release_notes_list.html

Cisco also provides Bug Toolkit, a web resource for tracking defects. To access Bug Toolkit, visit the following URL:

http://tools.cisco.com/Support/BugToolKit/action.do?hdnAction=searchBugs

Contents

Changes to the Release Notes

Caveats

Resolved Caveats for Release 7.0.x

New Features and Functionality

Related Documentation

Obtaining Documentation and Submitting a Service Request

Changes to the Release Notes

This section documents supplemental changes that have been added to the Release Notes for
Cisco ONS 15310-MA Release 7.0.4
since the production of the Cisco ONS 15310-MA System Software CD for Release 7.0.4.

The following changes have been added to the release notes for Release 7.0.4.

Changes to Caveats

The following caveats have been added.

CSCse85355

CSCsd52665

CSCsd56328

Caveats

Review the notes listed below before deploying the ONS 15310-MA. Caveats with tracking numbers are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without tracking numbers are provided to point out procedural or situational considerations when deploying the product.

Maintenance and Administration


Caution VxWorks is intended for qualified Cisco personnel only. Customer use of VxWorks is not recommended, nor is it supported by Cisco's Technical Assistance Center. Inappropriate use of VxWorks commands can have a negative and service affecting impact on your network. Please consult the troubleshooting guide for your release and platform for appropriate troubleshooting procedures. To exit without logging in, enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit after logging in, type "logout" at the VxWorks shell prompt.

CSCsc56694

IPPM enabled by CTC for an OCn trunk card is disabled automatically after two hours. This issue will be resolved in Release 8.0.

Alarms

CSCse85355

The NE should report alarms or conditions on ingress port not on any internal ports. Alarm detected at the internal ports (TERM) side will be ingress map to the MON side. So the NE raises the STS-MON/VT-MON and STS-TERM/VT-TERM alarms or conditions on the STS-MON/VT-MON ports, irrespective of the actual detection port (MON or TERM). If the user wants the customized severity to be reflected for a specifc STS/VT alarms, the alarm profile entities of both STS-MON and STS-TERM, if available, should be changed to the same severity.

CSCsd52665

The NE should report alarms or conditions on ingress port not on any internal ports. Alarm detected at the internal ports (TERM) side will be ingress map to the MON side. So the NE raises the STS-MON/VT-MON and STS-TERM/VT-TERM alarms or conditions on the STS-MON/VT-MON ports, irrespective of the actual detection port (MON or TERM). If the user wants the customized severity to be reflected for a specifc STS/VT alarms, the alarm profile entities of both STS-MON and STS-TERM, if available, should be changed to the same severity.

CSCsd56328

The NE should report alarms or conditions on ingress port not on any internal ports. Alarm detected at the internal ports (TERM) side will be ingress map to the MON side. So the NE raises the STS-MON/VT-MON and STS-TERM/VT-TERM alarms or conditions on the STS-MON/VT-MON ports, irrespective of the actual detection port (MON or TERM). If the user wants the customized severity to be reflected for a specifc STS/VT alarms, the alarm profile entities of both STS-MON and STS-TERM, if available, should be changed to the same severity.

Electrical IO Card

CSCsh17691

The 3-DS3 / 84 DS1 pack does not output any DS3 rate signal, i.e. no pulses, while in the IS or IS, AINS states if a crossconnection to the port is not in effect. The pack should put out a DS3 AIS signal when not crossconnected, regardless of its state. This appears when the crossconnection to the port is not present. No workaround available. This issue will be resolved in Release 8.01.

Common Control Cards

CSCsc52028

The CTX 2500 card does not accept more than 52 ENE sessions. Figuring 16 ENE sessions per GNE session, the expected ENE logins for 7 GNE sessions is 112, whereas the CTX 2500 accepts only 52. This issue will be resolved in Release 8.0.

Alarms

CSCse85355

After setting the alarm profile to report UNEQ-V as CR, the alarm still reports as the default, MJ, in some instances. To see this, on a single ONS 15310-MA create a path protection VT circuit using a single source with a primary and secondary destination to create the path selector. Inject UNEQ-V into the protect path (for example, CTX2). This declares a minor UNEQ-V. Now inject UNEQ-V into the working path (for example, CTX1). A major UNEQ-V will be declared, rather than the CR that the alarm profile is set to. If the UNEQ-V is injected into the working path first, then into the protect path, a CR UNEQ-V will be declared and is correct. The workaround is to apply profiles for UNEQ-V monitor and UNEQ-V term that both have the same severity desired. This issue will be resolved in a future release.

CSCsh20447

When you have two open slots and if you enable Alarms on open slots and do a retrive all alarms from TL1 Session you can see only one alarm even though you have two open slots. In 7.04 load, in CTC Provisioning->defaults->node->general->RaiseAlarmOnOpenSlot set this flag to true. Open a TL1 session; give RETR-COND-ALL: C. This issue is expected to be fixed in a future release.

CSCsh22922

Create a path protection between 310ma and 454 nodes have a loopback for OC3 card in 454. Create a vt circuit from 310ma to OC3 in 454. Connect test set to ds1 and pump traffic on ds1 port. From the CTC do edit circuit option, in switch column give a Manual to Protection switch. MAN-REQ alarm rises with severity as MN/NA. Change the severity of this alarm from CTC and give APPLY. Do a SYNC option from CTC. Even though you changed the severity of the Alarm that wont reflects in Conditions Pane. If you do a switch from Manual to working this works fine. This issue will be resolved in Release 8.0.

CSCsh20419

When you have two OPEN SLOTS in 15310MA and if you enable alarms on Open slots you will see only one alarm getting raised in Condition Pane of CTC. In 7.04 load, in CTC Provisioning->defaults->node->general->RaiseAlarmOnOpenSlot, set this flag to true. Do retrive in Conditions Pane. Only one alarm is raised, even though you have 2 open slots. This issue is expected to be fixed in a future release.

TL1


Note To be compatible with TL1 and DNS, all nodes must have valid names. Node names should contain alphanumeric characters or hyphens, but no special characters or spaces.


CSCsc51017

When multiple TL1 GNE and ENE sessions are created on a 30+ node network, some of the TL1 sessions might continue to be displayed in the user login pane under the network view, even when the sessions have been closed. If this occurs, restart CTC. This issue will be resolved in a future release.

CSCsh24550

Issuing the RTRV-NE-IPMAP command with ALL aid from TL1 to a 15310MA node retrieves the IP of 454 on the other side of DCC more than once. Command that creates the problem: RTRV-NE-IPMAP:: ALL: A; This issue will be resolved in Release 8.0.

CSCsh21744

The performance Monitoring registers for the counts SASCPP, UASCPP, SESCPP, ESCP, and CVCPP are not initialized to zero. May lead to a Threshold Crossing Alert. 1. DS1-28-DS3-EC1-3 and DS1-84-DS3-EC1-3 cards on 15310MA. 2. The DS3 ports configured with C-BIT frame format. 3. Command which will create the problem INIT-REG-T3: T3-1-1:1:: CVCPP; or SASCPP or SESCP or UASCP or ESCP.

Workaround: All the registers can be cleared at one go through the CTC or by the following TL1 command. INIT-REG-T3: T3-1-1:1: all. This issue is expected to be resolved in 8.01 release.

Resolved Caveats for Release 7.0.x

This section documents caveats resolved in Release 7.0.4.

Maintenance and Administration

CSCsg17018

The Inhibit FE loopback parameter for the mentioned cards should be set to true. (The check box should be checked.) Before you test this, a) Please delete the database. (FlmDeleteDb) b) And reboot the node. (Reboot)

You can check the parameter as mentioned below.

Card View

Maintenance Pane

Loopback Pane

Port pane on the card for which this is supported. (Mentioned in the bracket)

For 7.04 310MA

DS1_28_DS3_EC1_3_LINE_CARD (DS3 Port)

DS1_84_DS3_EC1_3_LINE_CARD (DS3 Port)

15454

DS3XM_LINE_CARD (DS3)

DS3XM12_LINE_CARD (DS3)

DS3I_LINE_CARD (DS3I)

DS3E_LINE_CARD (DS3)

DS3_EC1_48_LINE_CARD (DS3 & EC1 Port)

DS1_E1_56_LINE_CARD (You can see these values on loopback pane itself)

TL1

CSCsg22884

This bug is about retrieval of Far end Performance Monitoring values through TL1 on the 15310MA on the cards DS1-28-DS3-EC1-3 and DS1-84-DS3-EC1-84. Now these are retrievable through TL1.

Electrical IO Cards

CSCsd59042

When upgrading the software from Release 6.x.x to Release 7.x.x, the DS3 and EC1-12 cards fail to load if the node name begins with the letters FL. Changing the node name resolves this issue.

CSCsg23089

SF LED is ON even when all the DS3 or DS1 ports are in IS_AINS state. Expected behavior is, SF LED should be on only in IS state and if any of IS port has any alarms on it. In all other states it should be OFF. It is made consistent with expected behavior.

New Features and Functionality

The following feature has been added to the ONS 15310-MA for Release 7.0.2.

Daylight Savings Time Support

With Release 7.0.2 CTC and TL1 display daylight savings time (DST) in keeping with the new DST rules applicable from 2007 forward. As described in the change in energy policy for the United States of America (USA), the DST start date will be the 2nd Sunday of March and the DST end date will be 1st Sunday of November.

Related Documentation

Release-Specific Documents

Release Notes for the Cisco ONS 15310-CL Release 7.0

Release Notes for the Cisco ONS 15310-CL Release 7.0.x

Release Notes for the Cisco ONS 15454 SDH Release 7.0.x

Release Notes for the Cisco ONS 15327 Release 7.0.x

Release Notes for the Cisco ONS 15600 Release 7.0.x

Release Notes for the Cisco ONS 15454 Release 7.0.x

Platform-Specific Documents

Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide
Provides installation, turn up, test, and maintenance procedures

Cisco ONS 15310-CL and Cisco ONS 15310-MA Reference Manual
Provides technical reference information for cards, nodes, and networks

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide
Provides a list of SONET alarms and troubleshooting procedures, general troubleshooting information, transient conditions, and error messages

Cisco ONS SONET TL1 Command Guide
Provides a comprehensive list of TL1 commands

Cisco ONS SONET TL1 Reference Guide
Provides general information, procedures, and errors for TL1

Cisco ONS 15310-CL and Cisco ONS 15310-MA Ethernet Card Software Feature and Configuration Guide
Provides software feature and operation information for Ethernet cards

Obtaining Documentation and Submitting a Service Request

For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.