Cisco ONS SONET TL1 Command Guide, Release 10.x.x
Chapter 19, REPT Commands
Downloads: This chapterpdf (PDF - 675.0KB) The complete bookPDF (PDF - 12.54MB) | Feedback

Table of Contents

REPT Messages

REPT Messages

This chapter provides report (REPT) messages for the Cisco ONS 15454.


Note The REPT commands do not apply to the Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.


19.1 REPT ALM <MOD2ALM>

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm for 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, ETH, FSTE, G1000, GFPOS, GIGE, ILK, ISCCOMPAT, ISC3PEER2R, ISC3PEER1G, ISC3PEER2G, OC12, OC192, OC3, OC48, OCH, OMS, OTS, 10GFC, 8GFC, 10GIGE, 100GIGE, 40GIGE, OC192, OTU1, OTU2, OTU3, OTU4, POS, STM1, STM4, STM16, STM64, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC3, VC4, VC4-2c, VC4-3c, VC4-4c, VC4-8c,VC4-16c,VC4-64c, VC12, VCG, VT1, VT2, or WLEN (REPT ALM <MOD2ALM>) message reports an alarm condition against a facility, an RPR interface, or a path.

 
Usage Guidelines

See Table 30-1 for supported modifiers by platform.

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM <MOD2ALM>
“<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],
[<OCRTM>],[<LOCN>],[<DIRN>]:[<DESC>],[<AIDDET>]”
;

SID DATE TIME
** ATAG REPT ALM <MOD2ALM>
“<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>]:[<DESC>],[<AIDDET>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM 1GFC
“FAC-2-1:MJ,LOS,SA,08-01,14-25-59,,:\“LOSS OF SIGNAL\”,OC12”
;

Output Parameters

Parameter
Description

<AID>

Access identifier from the “LINE” and “FACILITY”.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared

  • CR

A critical alarm

  • MJ

A major alarm

  • MN

A minor alarm

  • NA

The condition is not alarmed

  • NR

The alarm is not reported

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Chapter 29, “Conditions” for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

  • NSA

The condition is non-service affecting

  • SA

The condition is service affecting

<OCRDAT>

(Optional) Date

<OCRTM>

(Optional) Time

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.2 REPT ALM BITS

( Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Building Integrated Timing Supply (REPT ALM BITS) message reports an alarm condition on a BITS facility.

 
Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM BITS
“<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>]:[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM BITS
“BITS-1:MJ,SYNC,SA,08-01,14-25-59,,:\“LOSS OF TIMING\””
;

Output Parameters

<AID>

Access identifier from the “BITS” section.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, the two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<CONDTYPE>

The condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 29, “Conditions” for a list of conditions.

<OCRDAT>

(Optional) Date

<OCRTM>

(Optional) Time

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

  • NSA

The condition is non-service affecting.

  • SA

The condition is service affecting.

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.3 REPT ALM COM

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Common (REPT ALM COM) message reports an alarm condition when an AID cannot be given. For example, a fan failure is reported using this message.

 
Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM COM
“[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>]:[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM COM
“COM:MJ,FAN,NSA,08-01,14-25-59,,:\“FAN FAILURE\””
;

Output Parameters

<AID>

(Optional) Access identifier. Identifies the entity to which the command pertains. Indicates an alarm without AID. AID is a string.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is the two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<CONDTYPE>

The condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 29, “Conditions” for a list of conditions.

<OCRDAT>

(Optional) Date

<OCRTM>

(Optional) Time

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

  • NSA

The condition is non-service affecting.

  • SA

The condition is service affecting.

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.4 REPT ALM ENV

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Environment (REPT ALM ENV) message reports a customer-defined condition on an environmental alarm input.

 
Usage Guidelines

None

Category

Environment

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM ENV
“<AID>:<NTFCNCDE>,<ALMTYPE>,[<OCRDAT>],[<OCRTM>],[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM ENV
“ENV-IN-1:MJ,OPENDR,08-01,14-25-59,\“OPEN DOOR\””
;

Output Parameters

<AID>

Access identifier from the “ENV” section. Identifies an environmental input.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<ALMTYPE>

Abbreviated code identifying the alarm. The parameter type is ENV_ALM, which is the environmental alarm types.

  • AIRCOMPR

Air compressor failure

  • AIRCOND

Air conditioning failure

  • AIRDRYR

Air dryer failure

  • BATDSCHRG

Battery discharging

  • BATTERY

Battery failure

  • CLFAN

Cooling fan failure

  • CPMAJOR

Centralized power major failure

  • CPMINOR

Centralized power minor failure

  • ENGINE

Engine failure

  • ENGOPRG

Engine operating

  • ENGTRANS

Standby engine transfer

  • EXPLGS

Explosive gas

  • FIRDETR

Fire detector failure

  • FIRE

Fire

  • FLOOD

Flood

  • FUELLEAK

Fuel leak

  • FUSE

Fuse failure

  • GASALARM

Explosive gas, toxic gas, ventilation fail, or gas monitor fail

  • HATCH

Controlled Environment Vault (CEV) hatch fail

  • GEN

Generator failure

  • HIAIR

High airflow

  • HIHUM

High humidity

  • HITEMP

High temperature

  • HIWTR

High water

  • INTRUDER

Intrusion

  • LEVELCON

Level converter

  • LVDADSL

Secondary ADSL low voltage disconnect

  • LVDBYPAS

Low voltage disconnect bypass

  • LWBATVG

Low battery voltage

  • LWFUEL

Low fuel

  • LWHUM

Low humidity

  • LWPRES

Low cable pressure

  • LWTEMP

Low temperature

  • LWWTR

Low water

  • MISC

Miscellaneous

  • OPENDR

Open door

  • POWER

Commercial power failure

  • PUMP

Pump failure

  • PWR-48

48 V power supply failure

  • PWR-139

–139 V power converter

  • PWR-190

–190 V power converter

  • PWRMJ

Power supply major

  • PWRMN

Power supply minor

  • RECT

Rectifier failure

  • RECTHI

Rectifier high voltage

  • RECTLO

Rectifier low voltage

  • RINGGENMJ

Ringing generator major

  • RINGGENMN

Ringing generator minor

  • RTACADSL

AC or AC/rectifier power fail ADSL equipment

  • RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

  • RTACPWR

AC or AC/rectifier power fail DCL equipment

  • RTACPWRENG

Commercial AC fail, site equipped with standby engine

  • RTBAYPWR

AC power loss distributed power RT bay

  • RTRVENG

Retrieve standby engine, commercial AC restored

  • SMOKE

Smoke

  • TEMP

High-low temperature

  • TOXICGAS

Toxic gas

  • TREPEATER

T-repeater shelf

  • VENTN

Ventilation system failure

<OCRDAT>

(Optional) Date.

<OCRTM>

(Optional) Time.

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.5 REPT ALM LMP

(Cisco ONS 15454) The Report Alarm Link Management Protocol (REPT ALM LMP) is the autonomous message which is used to report the LMP-FAIL alarms for the control channels and traffic engineering (TE) links.

 
Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME** ATAG REPT ALM LMP "[<AID>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>]:[<DESC>]"
;

Output Example

va454-5 1998-06-20 14:30:00
A 814.812 REPT ALM LMP
"CTRL-1:MJ,LMP-FAIL,NSA,08-01,14-25-59,,\"LMP Failure\","
;

Output Parameters

<AID>

The LMP control channel AID values.

  • CTRL-ALL

Specifies all the control channels.

  • CTRL-{1-4}

Specifies an individual control channel.

<NTFCNCDE>

The two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The condition is not reported.

<CONDTYPE>

The condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 29, “Conditions” for a list of conditions.

<SRVEFF>

Indicates the effect of the alarm on service.

  • NSA

The condition is non-service affecting.

  • SA

The condition is service affecting.

<OCRDAT>

(Optional) Date (YYYY-MM-DD)

<OCRTM>

(Optional) Time (HH:MM:SS)

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

The condition description.

19.6 REPT ALM EQPT

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Equipment (REPT ALM EQPT) message reports an alarm condition against an equipment unit or slot.

 
Usage Guidelines

None

Category

Equipment

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM EQPT
“<AID>:<NTFCNCDE>,<CONDITION>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>],:[<DESC>],[<AIDDET>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM EQPT
“SLOT-7:MJ,CONTR,NSA,08-01,14-25-59,NEND,RCV:\"CONTROLLER FAILURE\",TSC”
;

Output Parameters

Parameter
Description

<AID>

Access identifier from the “EQPT” section. Equipment AID SLOT-{1-17}.

<NTFCNCDE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<CONDITION>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed conditions (NA), and Not Reported (NR) conditions. See the Chapter 29, “Conditions” for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

  • NSA

The condition is non-service affecting.

  • SA

The condition is service affecting.

<OCRDAT>

(Optional) Date

<OCRTM>

(Optional) Time

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.7 REPT ALM SECU

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Security (REPT ALM SECU) reports the occurrence of an alarmed security event against the NE.

 
Usage Guidelines

Based on TR-NWT-000835, the AID of the security alarm should be the connection identifier (CID) that is not currently supported.

The COM or user identifier (UID) is an acceptable substitute for the AID.


Note The INTRUSION-PSWD condition is the only condition that is reported as a standing condition instead of a transient condition. It defaults to NA and is reported by the REPT EVT SECU message. However, it can be reprovisioned to be reported at a higher severity. If the severity of this alarm is higher than NA, it is reported by the REPT ALM SECU message.


Category

Security

Security

Superuser

Output Format

SID DATE TIME
** ATAG REPT ALM SECU
“<AID>:<NOTIFCODE>,<SECUALMTYPE>”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SECU
“COM:CR,INTRUSION-PSWD”
;

Output Parameters

<AID>

Access identifier. Identifies an entity with the condition. Defaults to COM. AID is a string.

<NOTIFCODE>

Two-letter notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<SECUALMTYPE>

Security alarm type. It is a subset of the CONDITION type. In this release, the only allowable type is INTRUSION-PSWD. The parameter type is SECUALMTYPE (security alarm type).

  • INTRUSION-PSWD

Condition raised after an invalid password is used during login. This condition is raised only if the password is used a specific number of times.

19.8 REPT ALM SYNCN

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Alarm Synchronization (REPT ALM SYNCN) message reports an alarm condition against a synchronization reference.

 
Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT ALM SYNCN
“<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],[<OCRTM>],[<LOCN>],
[<DIRN>]:[<DESC>],[<EQPTTYPE>]”
;

Output Example

TID-000 1998-06-20 14:30:00
** 100.100 REPT ALM SYNCN
“SYNC-NE:MJ,MAN,SA,08-01,14-25-59,,:\“MANUAL SWITCH\”,TCC”
;

Output Parameters

<AID>

Access identifier from the “SYNC_REF”. Identifies a synchronization reference with alarm condition.

<NTFCNCDE>

Notification code. The parameter type is NOTIF_CODE, which is a two-character notification code associated with an autonomous message.

  • CL

The condition causing the alarm has cleared.

  • CR

A critical alarm.

  • MJ

A major alarm.

  • MN

A minor alarm.

  • NA

The condition is not alarmed.

  • NR

The alarm is not reported.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Chapter 29, “Conditions” for a list of conditions.

<SRVEFF>

The effect on service caused by the standing alarm or condition. The parameter type is SERV_EFF, which is the effect of the alarm on service.

  • NSA

The condition is non-service affecting.

  • SA

The condition is service affecting.

<OCRDAT>

(Optional) Date

<OCRTM>

(Optional) Time

<DESC>

(Optional) Condition description.

<EQPTTYPE>

(Optional) The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.9 REPT DBCHG

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Database Change (REPT DBCHG) message reports any changes on the NE that result from:

  • TL1 provisioning commands or their graphical user interface (GUI) equivalents containing the verbs ALW, DLT, ED, ENT, INH, INIT, OPR, RLS, SET, and SW (for example, DLT-EQPT, ENT-CRS-STS1)
  • External event such as a board insertion

 
Usage Guidelines

  • When the secondary state is changed from AINS state to any other state, no REPT DBCHG messages are generated.
  • REPT DBCHG is turned off by default. To turn REPT DBCHG on, you must issue the ALW-MSG-DBCHG command.
  • REPT DBCHG messages are generated every time a roll is performed. A cross-connect delete and add REPT DBCHG message will not be sent every time a roll is performed; instead a REPT DBCHG message on the roll will be sent.

Category

Log

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT DBCHG
“TIME=<TIME>,DATE=<DATE>,[SOURCE=<SOURCE>],[USERID=<USERID>],
DBCHGSEQ=<DBCHGSEQ>:<COMMAND>:[<AID>]:::[<PSTPSTQ>,],<SST>”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT DBCHG
“TIME=14-35-46,DATE=99-07-28,SOURCE=123,USERID=CISCO15,DBCHGSEQ=456:
ENT-CRS-VT1:VT1-4-1-2-6-4:::PST-PSTQ,SST”
;

Output Parameters

<TIME>

The time of the message triggered by the NE.

<DATE>

The date of the message triggered by the NE.

<SOURCE>

(Optional) An input-command CTAG if present. SOURCE is a string. Maximum length of 20 characters.

<USERID>

(Optional) The user name or user identifier. USERID is a string. Maximum length of 20 characters.

<DBCHGSEQ>

Identifier or range of identifiers to be retrieved. It is a sequential number of the DBCHGSEQ message. DBCHGSEQ is an integer.

<COMMAND>

The input command or substitute. Maximum length of 20 characters. COMMAND is a string.

<AID>

Access identifier. Maximum length of 64 characters.Excess characters will be truncated. AID is a string.

<PSTPSTQ>

Admin state in the PST-PSTQ format. The parameter type is PST_PSTQ, which is the service state of the entity described by the primary state (SST) and a primary state qualifier (PSTQ).

  • IS-NR

In Service and Normal

  • OOS-AU

Out of Service and Autonomous

  • OOS-AUMA

Out of Service and Autonomous Management

  • OOS-MA

Out of Service and Management

<SST>

Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.

  • AINS

Automatic In-Service

  • DSBLD

Disabled

  • LPBK

Loopback

  • MEA

Mismatched Equipment

  • MT

Maintenance

  • OOG

Out of Group

  • SWDL

Software Download

  • UAS

Unassigned

  • UEQ

Unequipped

19.10 REPT EVT <MOD2ALM>

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event for 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS1, E100, E1000, E3, E4, EC1, ETH, FSTE, G1000, GFPOS, GIGE, ILK, ISCCOMPAT, ISC3PEER2R, ISC3PEER1G, ISC3PEER2G, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STM1,STM4,STM16,STM64, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, UDCDCC, UDCF, VC3, VC4, VC4-2c, VC4-3c, VC4-4c, VC4-8c, VC4-16c,VC4-64c, VC12, VCG, VT1, VT2, WLEN, or RPRIF (REPT EVT <MOD2ALM>) message reports the occurrence of a nonalarmed event. In Software Release 5.0 and later, REPT EVT <MOD2ALM> can report the remote monitoring (RMON)-managed threshold crossing alarm.

 
Usage Guidelines

See Table 30-1 for supported modifiers by platform.

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT <MOD2ALM>
“<AID>:<CONDTYPE>,[<CONDEFF>],,,[<LOCN>],[<DIRN>],[<MONVAL>],[<THLEV>],
[<TMPER>]:[<DESC>],[<AIDDET>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT 1GFC
“FAC-5-1:WKSWPR,TC,,,FEND,,12,13,15-MIN:\“WORKING SWITCH TO PROTECTION\”,
OC48”
;

Output Parameters

<AID>

Access identifier from the “ALL”.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Chapter 29, “Conditions”for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<LOCN>

(Optional) Location associated with a particular command in reference to the entity identified by the AID. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the Far End of the facility.

  • NEND

Action occurs on the Near End of the facility.

<DIRN>

Direction relative to the entity identified by the AID. Direction of PM relative to the entity identified by the AID. The parameter type is DIRECTION (transmit and receive directions).

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

  • TRMT

Transmit direction only

<MONVAL>

(Optional) Monitored value. Value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. MONVAL is a float.

<THLEV>

(Optional) Threshold level. THLEV is a float.

<TMPER>

(Optional) Accumulation time period for performance counters. The parameter type is TMPER, which is the accumulation time period for the performance management center.

  • 1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.

  • 1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

  • 1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

  • 15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

  • RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.11 REPT EVT BITS

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Building Integrated Timing Supply (REPT EVT BITS) message reports a non-alarmed event against a BITS facility.

 
Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
** ATAG REPT EVT BITS
“<AID>:<CONDTYPE>,[<CONDEFF>],,,[<LOCN>],[<DIRN>],,,:[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT ALM BITS
“BITS-1:SSM-STU,TC,,,,,,,:\“SYNCHRONIZED - TRACEABILITY UNKNOWN\””
;

Output Parameters

<AID>

Access identifier from the “BITS” section.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 node, whether or not the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 29, “Conditions” for a list of conditions.

<CONDEFF>

The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.12 REPT EVT COM

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Common (REPT EVT COM) message reports a nonalarmed event against an NE when there is no AID associated with it.

 
Usage Guidelines

None

Category

Fault

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT COM
“[<AID>]:<CONDTYPE>,[<CONDEFF>],,,,,,[<LOCN>],[<DIRN>]:[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT COM
“COM:CLDRESTART,TC,,,,,,,:\“COLD RESTART\”,”
;

Output Parameters

<AID>

(Optional) Access identifier. Identifies the entity to which the command pertains. AID is a string.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Chapter 29, “Conditions” for a list of conditions.

<CONDEFF>

The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.13 REPT EVT ENV

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Environment (REPT EVT ENV) message reports the occurrence of a nonalarmed event against an environment alarm input.

 
Usage Guidelines

None

Category

Environment

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT ENV
“<AID>:<ALMTYPE>,[<CONDEFF>],,,,,,[<LOCN>],[<DIRN>]:[<DESC>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT ENV
“ENV-IN-2:OPENDR,TC,,,,,,,:\“OPEN DOOR\””
;

Output Parameters

<AID>

Access identifier from the “ENV” section. Identifies an environmental input.

<ALMTYPE>

Abbreviated code identifying the alarm. The parameter type is ENV_ALM (environmental alarm types).

  • AIRCOMPR

Air compressor failure

  • AIRCOND

Air conditioning failure

  • AIRDRYR

Air dryer failure

  • BATDSCHRG

Battery discharging

  • BATTERY

Battery failure

  • CLFAN

Cooling fan failure

  • CPMAJOR

Centralized power major failure

  • CPMINOR

Centralized power minor failure

  • ENGINE

Engine failure

  • ENGOPRG

Engine operating

  • ENGTRANS

Standby engine transfer

  • EXPLGS

Explosive gas

  • FIRDETR

Fire detector failure

  • FIRE

Fire

  • FLOOD

Flood

  • FUELLEAK

Fuel leak

  • FUSE

Fuse failure

  • GASALARM

Explosive gas, toxic gas, ventilation fail, or gas monitor fail

  • HATCH

CEV hatch fail

  • GEN

Generator failure

  • HIAIR

High airflow

  • HIHUM

High humidity

  • HITEMP

High temperature

  • HIWTR

High water

  • INTRUDER

Intrusion

  • LEVELCON

Level converter

  • LVDADSL

Secondary ADSL low voltage disconnect

  • LVDBYPAS

Low voltage disconnect bypass

  • LWBATVG

Low battery voltage

  • LWFUEL

Low fuel

  • LWHUM

Low humidity

  • LWPRES

Low cable pressure

  • LWTEMP

Low temperature

  • LWWTR

Low water

  • MISC

Miscellaneous

  • OPENDR

Open door

  • POWER

Commercial power failure

  • PUMP

Pump failure

  • PWR-48

48 V power supply failure

  • PWR-139

–139 V power converter

  • PWR-190

–190 V power converter

  • PWRMJ

Power supply major

  • PWRMN

Power supply minor

  • RECT

Rectifier failure

  • RECTHI

Rectifier high voltage

  • RECTLO

Rectifier low voltage

  • RINGGENMJ

Ringing generator major

  • RINGGENMN

Ringing generator minor

  • RTACADSL

AC or AC/rectifier power fail ADSL equipment

  • RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

  • RTACPWR

AC or AC/rectifier power fail DCL equipment

  • RTACPWRENG

Commercial AC fail, site equipped with standby engine

  • RTBAYPWR

AC power loss distributed power RT bay

  • RTRVENG

Retrieve standby engine, commercial AC restored

  • SMOKE

Smoke

  • TEMP

High-low temperature

  • TOXICGAS

Toxic gas

  • TREPEATER

T-repeater shelf

  • VENTN

Ventilation system failure

<CONDEFF>

The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<DESC>

(Optional) Condition description.

19.14 REPT EVT EQPT

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Equipment (REPT EVT EQPT) message reports the occurrence of a nonalarmed event against an equipment unit or slot.

 
Usage Guidelines

None

Category

Equipment

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT EQPT
“<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,[<LOCN>],[<DIRN>]:[<DESC>],[<AIDDET>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT EQPT
“SLOT-7:PLUGIN,TC,,,,,,,:\“EQUIPMENT PLUG-IN\”,TCC”
;

Output Parameters

Parameter
Description

<AID>

Access identifier from the “EQPT” section. Equipment AID SLOT-{1-17}.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Chapter 29, “Conditions” for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.15 REPT EVT FXFR

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Software Download (REPT EVT FXFR) message reports the FTP software download status of the start, completion, and completed percentage.

 
Usage Guidelines

  • The FXFR_RSLT is only sent when the FXFR_STATUS is COMPLD.
  • The BYTES_XFRD is only sent when the FXFR_STATUS is IP or COMPLD.

Category

File Transfer

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT FXFR
“<FILENAME>,<FXFR_STATUS>,[<FXFR_RSLT>],[<BYTES_XFRD>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT FXFR
“NEW.PKG,COMPLD,SUCCESS,21215147”
;

Output Parameters

<FILENAME>

When a package is being transferred between the FTP server and the controller cards, the filename field will contain the string ACTIVE. Following this transfer, if there is a second common-control card on the NE, the file will be copied over to the second card during which time REPT EVT FXFR messages will be generated with a filename of STANDBY. FILENAME is a string.

<FXFR_STATUS>

The status of the file transfer. The parameter type is TX_STATUS, which is the status of the file transfer.

  • COMPLD

The file transmission is completed.

  • IP

The file transmission is in progress.

  • START

The file transmission is started.

<FXFR_RSLT>

(Optional) The result of the file transfer. The parameter type is TX_RSLT, which is the result of the file transfer.

  • FAILURE

A failed result

  • SUCCESS

A successful result

<BYTES_XFRD>

(Optional) The percentage of bytes transferred. BYTES_XFRED is a string.

19.16 REPT EVT IOSCFG

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Internet Operating System Configuration File (REPT EVT IPSCFG) message reports the status of copying the Cisco IOS configuration file when the COPY-IOSCFG command is issued.

 
Usage Guidelines

  • You can identify if this message is caused by a Cisco IOS configuration file downloading, uploading, or merging by looking at the SRC and DEST fields in the message. See the “COPY-IOSCFG” section for more details.
  • There is no success/failure in the message to indicate the success or failure of the merge process when merging the startup Cisco IOS config file to the running config file.

Category

File Transfer

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT IOSCFG
“<AID>:<SRC>,<DEST>,<STATUS>,[<RESULT>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT IOSCFG
“SLOT-1:STARTUP,IOS-CONFIG-FILE-IN-NETWORK,COMPLD,SUCCESS”
;

Output Parameters

<AID>

Access identifier from the “EQPT” section. Slot AID for the equipment.

<SRC>

Source access identifier. Specifies where the Cisco IOS configuration file is copied from. SRC is a string.

<DEST>

Destination. Specifies where the Cisco IOS configuration file is copied to. DEST is a string.

<STATUS>

The status of COPY-IOSCFG. The parameter type is TX_STATUS, which is the status of the file transfer.

  • COMPLD

The file transmission is completed.

  • IP

The file transmission is in progress.

  • START

The file transmission is started.

<RESULT>

(Optional) The result of the file transfer. The parameter type is TX_RSLT, which is the result of the file transfer.

  • FAILURE

A failed result

  • SUCCESS

A successful result

19.17 REPT EVT SECU

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Security (REPT EVT SECU) message reports the occurrence of a nonalarmed security event against the NE.

 
Usage Guidelines

  • Based on TR-NWT-000835 in TR-NWT-000835 and the AID of the security alarm should be the CID, which is not supported in this release. The COM or UID is an acceptable substitute for the AID here. CIDs will be supported in a future release.
  • For the rule of single failure, single message/alarm, the security alarm will not be reported as REPT ALM COM, because it is reported as REPT ALM SECU.
  • Because the NE sends this security message as a transient message, to make all TL1 autonomous messages consistent, the TL1 agent reports the security message into REPT EVT SECU.
  • This message is inhibited by default. A Superuser will have to issue the ALW-MSG-SECU to see this message.

Category

Security

Security

Superuser

Output Format

SID DATE TIME
A ATAG REPT EVT SECU
“<AID>:<DNFIELD>,[<CONDEFF>],,,[<LOCN>],[<DIRN>],,,:<SECURITY>:<DNFIELD1>”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SECU
“COM:LOGIN-FAILURE-PSWD,TC,,,,,,,:\“SECURITY:
INVALID LOGIN - PASSWORD - SEE AUDIT LOG\””
;

Output Parameters

<AID>

Access identifier. Identifies an entity with the condition. Defaults to COM. AID is a string.

<DNFIELD>

String

<CONDEFF>

The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

The PM count retrieval direction. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

<SECURITY>

SECURITY is a string.

<DNFIELD1>

DNFIELD1 is a string.

19.18 REPT EVT SESSION

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Session (REPT EVT SESSION) message reports a nonalarmed event related to establishing a session with the NE.

 
Usage Guidelines

The WARN field might contain different information depending on the type of session-related event.

  • If the password aging feature has not been enabled (or the feature is enabled but the password is not close to expiring):

/*USER <UID> LOGGED IN <IP/SERIAL PORT*/

  • If the forced password feature is enforced and the user is logging in for the first time (or the password has expired):

/*PLEASE CHANGE PASSWORD BEFORE CONTINUING*/

  • If a session is terminated for any reason (except a user timeout), the reason for the session termination is indicated in the WARN field.

Category

Security

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT SESSION
“<AID>:<EXP>,<PCN>”
“<WARN>”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SESSION
“TCCP:YES,5-DAY”
“/* USER TERRI LOGGED IN TO TCCP */”
;

Output Parameters

<AID>

Access identifier. Identifies the NE with which a session is established. AID is a string.

<EXP>

Indicates whether the password is alive (for example, no password updating is required at the moment), expired, or is about to expire. The parameter type is YES_NO, which indicates whether the user’s password is about to expire, the user is logged into the NE, or the user is locked out of the NE.

  • NO

No

  • YES

Yes

<PCN>

The number of days still remaining before the existing password expires. PCN appears only if EXP=YES and one of the following conditions has been met:

  • The warning period has not been exhausted.
  • The user is a new user establishing a session for the first time and the forced password change policy has been activated.

PCN is a string.

<WARN>

Free format text containing additional information about the security event. WARN is a string.

19.19 REPT EVT SYNCN

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Event Synchronization (REPT EVT SYNCN) message reports the occurrence of a nonalarmed event against a synchronization entity.

 
Usage Guidelines

None

Category

Synchronization

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT EVT SYNCN
“<AID>:<CONDTYPE>,[<CONDEFF>],,,,,,[<LOCN>],[<DIRN>]:[<DESC>],[<AIDDET>]”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT EVT SYNCN
“SYNC-NE:SWTOINT,SC,,,,,,,:\“SWITCH TO INTERNAL CLOCK\”,TCC”
;

Output Parameters

Parameter
Description

<AID>

Access identifier from the “SYNC_REF”.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is CONDITION, which is any problem detected on an ONS 15454 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not Alarmed (NA) conditions, and Not Reported (NR) conditions. See the Chapter 29, “Conditions” for a list of conditions.

<CONDEFF>

(Optional) The effect of the event on the condition of the NE. The parameter type is COND_EFF, which is the state of the condition upon the affected unit.

  • CL

Standing condition cleared

  • SC

Standing condition raised

  • TC

Transient condition

<DESC>

(Optional) Condition description.

<AIDDET>

(Optional) AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The parameter type is EQPT_TYPE, which is the type of equipment being provisioned into a slot.

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157
  • FBGDCU-1322
  • FBGDCU-165
  • FBGDCU-1653
  • FBGDCU-1983
  • FBGDCU-331
  • FBGDCU-496
  • FBGDCU-661
  • FBGDCU-826
  • FBGDCU-992
  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM
  • MD-48-EVEN
  • MD-48-ODD
  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

19.20 REPT PM <MOD2>

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Performance Monitoring for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, ETH, FSTE, G1000, GFPOS, GIGE, HDTV, ILK, ISCCOMPAT, ISC3PEER2R, ISC3PEER1G, ISC3PEER2G, OC12, OC192, OC3, OC48, OCH, OMS, OTS, 10GFC, 8GFC,10GIGE,100GIGE,40GIGE,OC192,OTU1,OTU2,OTU3, OTU4, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, or VT2 (REPT PM <MOD2>) message reports autonomous monitoring statistics as a result of the schedule created by SCHED-PMREPT.

 
Usage Guidelines

See Table 30-1 for supported modifiers by platform.


Note Autonomous performance monitoring (Auto PM) report will have all PM paths reported without any filtering. If a particular parameter is not applicable to that card or circuit, then the value of MONVAL and VLDTY will be NA.


Category

Performance

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT PM <MOD2>
“<AID>:<MONTYPE>,<MONVAL>,<VLDTY>,<LOCN>,<DIRN>,<TMPER>,<MONDAT>,
<MONTM>”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100 REPT PM 10GFC
“FAC-3-1:CVL,10,PRTL,NEND,BTH,15-MIN,05-25,14-46”
;

Output Parameters

<AID>

Access identifier from the “ALL” section.

<MONTYPE>

Monitored type. The parameter type is ALL_MONTYPE, which is the monitoring type list.

  • AISSP

Alarm Indication Signal Seconds Path

  • ALL

All possible values

  • BBE-PM

OTN—Background Block Errors—Path Monitor Point

  • BBE-SM

OTN—Background Block Errors—Section Monitor Point

  • BBER-PM

OTN—Background Block Error Ratio—Path Monitor Point expressed as one tenth of a percentage.

  • BBER-SM

OTN—Background Block Error Ratio—Section Monitor Point expressed as one tenth of a percentage.

  • BIEC

FEC—Bit Errors Corrected

  • CGV

8B10B—Code Group Violations

  • CSSP

Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)

  • CVCPP

Coding Violations—CP-Bit Path

  • CVL

Coding Violations—Line

  • CVP

Coding Violations—Path

  • CVS

Coding Violations—Section

  • CVV

Coding Violations—Section

  • DCG

8B10B—Data Code Groups

  • ESAP

Errored Second Type A—Path (DS3XM-12 DS1 PM count)

  • ESBP

Errored Second Type B—Path (DS3XM-12 DS1 PM count)

  • ESCPP

Errored Seconds—CP Bit Path

  • ESL

Errored Seconds—Line

  • ESNPFE

Errored Second—Network Path (DS3XM-12 DS1 PM count)

  • ESP

Errored Seconds—Path

  • ES-PM

OTN—Errored Seconds—Path Monitor Point

  • ES-SM

OTN—Errored Seconds—Section Monitor Point

  • ESR

Errored Second—Ratio

  • ESR-PM

Errored Seconds Ratio—Path monitor point expressed as one tenth of a percentage

  • ESR-SM

Errored Seconds Ratio—Section monitor point expressed as one tenth of a percentage

  • ESS

Errored Seconds—Section

  • ESV

Errored Seconds—VT Path

  • etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

  • etherStatsCollisions

Number of transmit packets that are collisions

  • etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including frame check sequence [FCS] octets) of between 64 and 1518 octets

  • etherStatsDropEvents

Number of received frames dropped at the port level

  • etherStatsFragments

The total number of packets received that were less than 64 octets

  • etherStatsJabbers

The total number of packets received that are longer than 1518 octets

  • etherStatsOctets

The total number of octets of data

  • etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

  • etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

  • etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

  • FCP

Failure Count—Line

  • FC-PM

OTN—Failure Count—Path Monitor Point

  • FC-SM

OTN—Failure Count—Section Monitor Point

  • HP-AR

Availability Ratio

  • HP-BBE

High-Order Path Background Block Error

  • HP-BBER

High-Order Path Background Block Error Ratio

  • HP-EB

High-Order Path Errored Block

  • HP-ES

High-Order Path Errored Second

  • HP-ESA

High-Order Path Errored Seconds—A

  • HP-ESB

High-Order Path Errored Seconds—B

  • HP-ESR

High-Order Path Errored Second Ratio

  • HP-FC

High-Order Path Failure Count

  • HP-NPJC-PDET

High-Order Path Negative Pointer Justification Count, Path Detected

  • HP-NPJC-PGEN

High-Order Path, Negative Pointer Justification Count, Path Generated

  • HP-OI

Outage Intensity

  • HP-PJCDIFF

High-Order Path Pointer Justification Count Difference

  • HP-PJCS-PDET

High-Order Path Pointer Justification Count, Path Detected

  • HP-PJCS-PGEN

High-Order Path Pointer Justification Count Seconds, Path Generated

  • HP-PPJC-PDET

High-Order Path Positive Pointer Justification Count, Path Detected

  • HP-PPJC-PGEN

High-Order Path, Positive Pointer Justification Count, Path Generated

  • HP-SEPI

The number of SEP events in available time

  • HP-SES

High-Order Path Severely Errored Seconds

  • HP-SESR

High-Order Path Severely Errored Second Ratio

  • HP-UAS

High-Order Path Unavailable Seconds

  • ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

  • ifInDiscards

The number of inbound packets

  • ifInErrorBytePktss

Receive Error Byte

  • ifInErrors

The number of inbound packets (or transmission units) that contained errors

  • ifInFramingErrorPkts

Receive Framing Error

  • ifInJunkInterPkts

Receive Interpacket Junk

  • ifInMulticastPkts

Number of multicast packets received since the last counter reset

  • ifInOctets

Number of bytes transmitted since the last counter reset

  • ifInUcastPkts

Number of unicast packets received since the last counter reset

  • ifOutBroadcastPkts

Number of broadcast packets transmitted

  • ifOutDiscards

The number of outbound packets

  • ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

  • ifOutMulticastPkts

Number of multicast packets transmitted

  • ifOutPayloadCrcErrors

Received payload cyclic redundancy check (CRC) errors

  • ifOutUcastPkts

Number of unicast packets transmitted

  • IOS

8B10B—Idle Ordered Sets

  • IPC

Invalid Packet Count

  • LBCL-AVG

Average Laser Bias current in microA

  • LBCL-MAX

Maximum Laser Bias current in microA

  • LBCL-MIN

Minimum Laser Bias current in microA

  • LBCN

Normalized Laser Bias Current for OC3-8

  • LBCN-HWT

Laser Bias Current

  • LBCN-LWT

Laser Bias Current

  • LOSSL

Loss of Signal Seconds—Line

  • LP-BBE

Low-Order Path Background Block Error

  • LP-BBER

Low-Order Path Background Block Error Ratio

  • LP-EB

Low-Order Path Errored Block

  • LP-ES

Low-Order Path Errored Second

  • LP-ESA

Low-Order Path Errored Seconds—A

  • LP-ESB

Low-Order Path Errored Seconds—B

  • LP-ESR

Low-Order Path Errored Second Ratio

  • LP-FC

Low-Order Path Failure Count

  • LP-NPJC-DET

Low-Order Negative Pointer Justification Count, Detected

  • LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

  • LP-PPJC-DET

Low-Order Positive Pointer Justification Count, Detected

  • LP-PPJC-GEN

Low-Order positive Pointer Justification Count, Generated

  • LP-SEP

Low-Order Path Severely Errored Period

  • LP-SEPI

Low-Order Path Severely Errored Period Intensity

  • LP-SES

Low-Order Path Severely Errored

  • LP-UAS

Low-Order Path Unavailable Seconds

  • MS-PSC

Protection switch count

  • MS-PSD

Protection switch duration

  • NIOS

8B10B—Non Idle Ordered Sets

  • NPJC-PDET

Negative Pointer Justification Count, Path Detected

  • NPJC-PGEN

Negative Pointer Justification Count, Path Generated

  • OPR-AVG

Average Receive Power in tenths of a microW

  • OPR-MAX

Maximum Receive Power in tenths of a microW

  • OPR-MIN

Minimum Receive Power in tenths of a microW

  • OPRN

Normalized Optical Receive Power for OC3-8

  • OPRN-MAX

Maximum value for OPRN

  • OPRN-MIN

Minimum value for OPRN

  • OPT-AVG

Average Transmit Power in tenths of a microW

  • OPT-MAX

Maximum Transmit Power in tenths of a microW

  • OPT-MIN

Minimum Transmit Power in tenths of a microW

  • OPTN

Normalized value for Optical Power Transmitted for the OC3-8 card

  • OPTN-MAX

Maximum value for OPTN

  • OPTN-MIN

Minimum value for OPTN

  • OPWR-AVG

Optical Power—Average Interval Value in one tenth of a dBm

  • OPWR-MAX

Optical Power—Maximum Interval Value in one tenth of a dBm

  • OPWR-MIN

Optical Power—Minimum Interval Value in one tenth of a dBm

  • PPJC-PDET

Positive Pointer Justification Count, Path Detected

  • PPJC-PGEN

Positive Pointer Justification Count, Path Generated

  • PRE-FECBER

Enum to hold PRE-FECBER value

  • PSC

Protection Switching Count

  • PSC-R

Protection Switching Count—Ring

  • PSC-S

Protection Switching Count—Span

  • PSC-W

Protection Switching Count—Working

  • PSD

Protection Switching Duration

  • PSD-R

Protection Switching Duration—Ring

  • PSD-S

Protection Switching Duration—Span

  • PSD-W

Protection Switching Duration—Working

  • SASCPP

Severely Errored Framing/Alarm Indication Signal (SEF/AIS) Second—CP-Bit Path

  • SASP

Severely Errored Framing/AIS Seconds Path

  • SEFS

Severely Errored Framing Seconds

  • SEFSP

Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)

  • SESCPP

Severely Errored Second—CP-Bit Path

  • SESL

Severely Errored Second—Line

  • SESNPFE

Severely Errored Second—Network Path (DS3XM-12 DS1 PM count)

  • SESP

Severely Errored Second—Path

  • SES-PM

OTN—Severely Errored Second—Path

  • SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as one tenth of a percentage

  • SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as one tenth of a percentage

  • SESS

Severely Errored Second—Section

  • SES-SM

OTN—Severely Errored Second—Section Monitor Point

  • SESV

Severely Errored Second—VT Path

  • UASCPP

Unavailable Second—CP-Bit Path

  • UASL

Unavailable Second—Line

  • UASNPFE

Unavailable Second—Network Path (DS3XM-12 DS1 PM count)

  • UASP

Unavailable Second—Path

  • UAS-PM

OTN—Unavailable Second—Path Monitor Point

  • UAS-SM

OTN—Unavailable Second—Section Monitor Point

  • UASV

Unavailable Second—VT Path

  • UNC-WORDS

Forward Error Correction (FEC)—Uncorrectable Words

  • VPC

Valid Packet Count

<MONVAL>

The value to which the register identified by MONTYPE is to be initialized to or the measured value of a monitored parameter. The value is in the form of numeric counts or rates. MONVAL is a string.

<VLDTY>

Indicates whether the information for the specified time period was accumulated over the entire time period or a portion of that time period. Validity indicator for the reported PM data. The parameter type is VALIDITY, which is the response validity.

  • COMPL

Complete response

  • PRTL

Partial response

<LOCN>

Location associated with a particular command in reference to the entity identified by the AID. The parameter type is LOCATION, which is the location where the action is to take place.

  • FEND

Action occurs on the far end of the facility.

  • NEND

Action occurs on the near end of the facility.

<DIRN>

Direction relative to the entity identified by the AID. Direction of PM relative to the entity identified by the AID. The parameter type is DIRECTION, which is the transmit and receive directions.

  • BTH

Both transmit and receive directions

  • RCV

Receive direction only

  • TRMT

Transmit direction only

<TMPER>

Accumulation time period for performance counters. The parameter type is TMPER, which is the accumulation time period for the performance management center.

  • 1-DAY

Performance parameter accumulation interval length; every 24 hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.

  • 1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

  • 1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

  • 15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

  • RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.

<MONDAT>

The beginning date of the PM or storage register period specified in TMPER. The format is MM-DD. MONDAT is a string.

<MONTM>

The beginning time of day of the PM or storage register period specified in TMPER. The format is HH-MM. MONTM is a string.

19.21 REPT SW

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Report Switch (REPT SW) message reports the autonomous switching of a unit in a duplex equipment pair to the standby state and its mate unit to the active state. An automatic report for the occurrence or clearance of an alarm or event that triggers the switch might be associated with the message.

 
Usage Guidelines

None

Category

Protection

Security

Retrieve

Output Format

SID DATE TIME
A ATAG REPT SW
“<ACTID>,<STDBYID>”
;

Output Example

TID-000 1998-06-20 14:30:00
A 100.100 REPT SW
“SLOT-8,SLOT-10”
;

Output Parameters

<ACTID>

Identifies the equipment unit from the “EQPT” section that was placed in the active state. Parameter grouping cannot be used with this parameter.

<STDBYID>

Identifies the equipment unit from the “EQPT” section that was placed in the standby state. Parameter grouping cannot be used with this parameter.