Cisco ONS SONET TL1 Command Guide, Release 10.x.x
Chapter 7, CHG Commands
Downloads: This chapterpdf (PDF - 214.0KB) The complete bookPDF (PDF - 12.52MB) | Feedback

Table of Contents

CHG Commands

CHG Commands

This chapter provides change (CHG) commands for the Cisco ONS 15454, Cisco ONS 15454 M2, and Cisco ONS 15454 M6.


NoteAll commands supported on the Cisco ONS 15454 platform are also supported on Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.


7.1 CHG-ACCMD-<MOD_TACC>

(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Change Test Access Mode for the DS1, DS3I, E1, E3, STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS96C, STS6C, STS9C, T1, T3, VT1, or VT2 (CHG-ACCMD-<MOD_TACC>) command changes the test access (TACC) mode for the circuit being tested. This can be a change from monitoring the data to inserting data into the synchronous transport signal (STS). For more information about TACC, refer to the Cisco ONS SDH and Cisco ONS 15600 SONET TL1 Reference Guide . See Table 30-1 for supported modifiers by platform.

 
Usage Guidelines

This command can only be applied to an existing test access point (TAP) connection.


Caution For this command to be applicable, first create the TAP using the ED-<MOD_PATH> command. Intrusive test access modes are traffic-affecting. If a facility/path is connected to a TAP in an intrusive test access mode, it is forced to go into the Out of Service, Maintenance (OOS-MT) state. The forced transition could be traffic-affecting. The present state of the facility/path is stored by the network element (NE) and is restored when the TAP connection is terminated. Test access connections are dropped automatically if the TL1 session is terminated or is timed out.


Note • If there is no TAP connection, a DENY error message is returned.

  • If a requested condition already exists, a SRCN error message is returned.
  • If a requested access configuration is invalid, a SRAC error message is returned.
  • If a requested TAP does not exist, a RTEN error message is returned.


 

Category

Troubleshooting and Test Access

Security

Maintenance

Input Format

CHG-ACCMD-<MOD_TACC>:[<TID>]:<TAP>: <CTAG>::<MD>;

Input Example

CHG-ACCMD-STS1:CISCO:8:123::MONE;

Input Parameters

<TAP>

The test access point number. The TAP number must be an integer with a range of 1 to 999. It is a string.

Note This command only supports changing the mode for a single TAP number at a time.

<MD>

The test access mode. (SPLTE, SPLTF, LOOPE, and LOOPF require an external quasi-random signal [QRS] input signal.) Single facility access digroup (FAD ) test access does not support MONEF, SPLTEF, and SPLTAB modes.

The parameter type is test access mode (TACC_MODE).

  • LOOPE

Splits both the A and B paths. Connect the line incoming from the E direction to the line outgoing in the E direction, and connect this looped configuration to the FAD. The line outgoing in the F direction will have a QRS connected, and the line incoming from the F direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

  • LOOPF

Splits both the A and B paths. Connect the line incoming from F direction to the line outgoing in the F direction, and connect this looped configuration to the FAD. The line outgoing in the E direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

  • MONE

Indicates that a monitor connection will be provided from the FAD to the A transmission path of the accessed circuit.

  • MONEF

Indicates that a monitor connection will be provided for the following:

  • From the FAD1 to a dual FAD (DFAD), or from the odd pair of a facility access path (FAP) to the A transmission path
  • From the FAD2 of the same DFAD or the even pair of a FAP, to the B transmission path of the accessed circuit
  • MONF

Indicates that a monitor connection will be provided from the FAD to the B transmission path of the accessed circuit.

  • SPLTA

Indicates that a connection will be provided from both the E and F sides of the A transmission path of the circuit under test to the FAD and split the A transmission path. Intrusive test access mode.

  • SPLTB

Indicates that a connection will be provided from both the E and F sides of the B transmission path of the circuit under test to the FAD and split the B transmission path. Intrusive test access mode.

  • SPLTE

Splits both the A and B paths and connect the E side of the accessed circuit to the FAD. The line outgoing in the F direction will have a QRS connected, the line incoming from the F direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

  • SPLTEF

Splits both the A and B paths, and connect the E side of the accessed circuit to FAD1 and the F side to FAD2. Intrusive test access mode.

  • SPLTF

Splits both the A and B paths, and connect the F side of the accessed circuit to the FAD. The line outgoing in the E direction will have a QRS connected, the line incoming in the E direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

7.2 CHG-EQPT

(Cisco ONS 15454) The Change Equipment (CHG-EQPT) command performs an in-service upgrade from low density (LD) electrical cards (DS1 [DS1-14, DS1N-14], DS3 [DS3-12, DS3N-12, DS3NE-12], EC1, and DS3XM-6) to high density (HD) electrical cards (DS1/E1-56, DS3/EC1-48, and DS3XM-12).

 
Usage Guidelines

  • For Software Release 6.0 and later, only limited upgrades are supported, such as upgrading one LD DS3-12 card to one HD DS3/EC1-48 card.
  • Optical (OC-N) card upgrades and downgrades are supported with the limitations of the MRC-12 and MRC-2.5G-4 cards.
  • Compatible equipment types for card upgrade:

DS3XM-6 to DS3XM-12

DS-3/DS3-N/DS3-E/DS3N-E to DS3/EC1-48

DS-1/DS1-N to DS1/E1-56

DS1-28-DS3-EC1-3

DS1-84-DS3-EC1-3

  • Provisioning rules for card upgrade:

DS1-14 and DS1N-14 cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 should be upgraded to DS1/E1-56.

DS1-14 and DSN-14 cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS1/E1-56.

DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 can be upgraded to DS3/EC1-48.

DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS3/EC1-48.

Two upgradable cards provisioned in a 1:1 protection group cannot be upgraded.

Category

Equipment

Security

Maintenance

Input Format

CHG-EQPT:[<TID>]:<AID>:<CTAG>::<EQPTTYPE>:[PPMTYPE=PPMTYPE>],
[PPMNUM=<PPMNUM>],[PORTNUM=<PORTNUM>],[PORTRATE=<PORTRATE>];

Input Example

CHG-EQPT::SLOT-14:1::MRC-2.5G-4:PPMTYPE=PPM-1,PPMNUM=1,PORTNUM=1,
PORTRATE=OC48;

Input Parameters

Input Parameters
Description

<SRC>

The source access identifier from the “EQPT” section.

<EQPTTYPE>

The equipment type to be upgraded. The parameter type is EQUIPMENT_TYPE.

  • 10GE-XP

(ONS 15454) 2 x 10 Gbps. muxponder/L2 ethernet switch card

  • 100G-LC-C

100G-LC-C card

  • 100G-CK-C

100G-CK-C card

  • 10X10G-LC

10X10G-LC card

  • CFP-LC

CFP-LC card

  • AR-MXP

Any rate muxponder

  • AR-XP

Any rate xponder

  • AR-XPE

Any rate enhanced xponder.

  • 16-WXC-FS

16-WXC-FS card.

  • 15216-MD-40-EVEN

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid

  • 15216-MD-40-ODD

Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid

  • 15216-MD-ID-50

Thermal Interleaver Passive Unit, spaced at 50 GHz grid

  • 15216-FLD4-30-3

Edge 4-Ch Bi-Directional OADM Module 1530.33 to 1532.68.

  • 15216-FLD4-33-4

Edge 4-Ch Bi-Directional OADM Module 1533.47 to 1535.82.

  • 15216-FLD4-36-6

Edge 4-Ch Bi-Directional OADM Module 1536.61 to 1538.98.

  • 15216-FLD4-39-7

Edge 4-Ch Bi-Directional OADM Module 1539.77 to 1542.14.

  • 15216-FLD4-42-9

Edge 4-Ch Bi-Directional OADM Module 1542.94 to 1545.32.

  • 15216-FLD4-46-1

Edge 4-Ch Bi-Directional OADM Module 1546.12 to 1548.51.

  • 15216-FLD4-49-3

Edge 4-Ch Bi-Directional OADM Module 1549.32 to 1551.72.

  • 15216-FLD4-52-5

Edge 4-Ch Bi-Directional OADM Module 1552.52 to 1554.94.

  • 15216-FLD4-55-7

Edge 4-Ch Bi-Directional OADM Module 1555.75 to 1558.17.

  • 15216-FLD4-58-9

Edge 4-Ch Bi-Directional OADM Module 1558.98 to 1561.42.

  • 32DMX-L

3- channel demultiplexer for L-band

  • 32WSS-L

32-channel wavelength switch selector for L-band

  • 40-MXP-C

40 Gbit/Sec Multirate Muxponder

  • 40-SMR1-C

The single module 40-channel ROADM on C-band

  • 40-SMR2-C

The single module 40-channel ROADM with EDFA on C-band

  • 40-TXP-C

40 Gigabits per second Multirate Transponder

  • 80-WXC-C

80-channel wavelength cross-connect spaced at 100 GHz grid

  • AD-1B

OADM 1-Band Filter

  • AD-1C

OADM 1-Channel Filter

  • AD-2C

OADM 2-Channel Filter

  • AD-4B

OADM 4-Band Filter

  • AD-4C

OADM 4-Channel Filter

  • AICI

AIC-I card

  • AIP

Alarm Indication Panel

  • ALM-PWR

Alarm Power

  • ASAP-4

ASAP carrier card with four PIM slots

  • BP

The backplane of the NE

  • CE-100T-8

8-port 100T card

  • CE-1000-4

4-port GIGE mapper card

  • CRFT-TMG

Craft Timing

  • DCC

Data Communications Channel

  • DCU

Dispersion Compensation Unit

  • DMX-32

Optical DMX 32 Channels

  • DS3i-N-12

DS3i-N-12 card

  • E1

E1 card

  • E1-42

42-port E1 card

  • E1000T-2

2-port interface card supporting 1000BaseT Ethernet facilities

  • E100T-12

12-port interface card supporting 100BaseT Ethernet facilities

  • E100T-4

Four-port interface card supporting 100BaseT Ethernet facilities

  • E1N

E1N card

  • E3

E3 card

  • EDRA-1-26

EDRA-1-26 amplifier

  • EDRA-1-35

EDRA-1-35 amplifier

  • EDRA-2-26

EDRA-2-26 amplifier

  • EDRA-2-35

EDRA-2-35 amplifier

  • FBGDCU-1157

 

  • FBGDCU-1322

 

  • FBGDCU-165

 

  • FBGDCU-1653

 

  • FBGDCU-1983

 

  • FBGDCU-331

 

  • FBGDCU-496

 

  • FBGDCU-661

 

  • FBGDCU-826

 

  • FBGDCU-992

 

  • FILLER_CARD

Filler card

  • FMEC-155E-1TO1

The equipment type for FMEC STM1E12 card

  • FMEC-155E-1TO3

The equipment type for FMEC STM1E12 card with 1:3 protection

  • FMEC-155E-UNPROT

The equipment type for FMEC STM1E12 card without protection

  • FMEC-SMZ-E1

FMEC card corresponding to E1 card

  • FMEC-SMZ-E3

FMEC card corresponding to E3 card

  • FTA

Fan Tray of the NE

  • FTA1

Fan Tray 1 of the NE

  • FTA2

Fan Tray 2 of the NE

  • G1K-4

G1K-4 card

  • MD-4

Optical Multiplexer/Demultiplexer with 4 Channels

  • MD-48-CM

 

  • MD-48-EVEN

 

  • MD-48-ODD

 

  • MESH-PP-SMR

The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards

  • MF-16AD-CFS

16-channels - 1 direction, colorless, omnidirectional add/drop unit.

  • MF-4x4-COFS

4-channels, 4-directions, colorless, omnidirectional add/drop unit.

  • MF-AST-EDFA

MF-AST-EDFA unit

  • MF-DEG-5

5-degrees mesh patch panel

  • MF-MPO-8LC

MPO to 8-LC adapter

  • MF-UPG-4

4-degrees upgrade module

  • ML100X-8

8-port 100X card with optical interface

  • ML-100T-8

8-port 100T card with optical interface

  • MMU

Multiring mesh upgrade unit

  • MS-ISC-100T

Fast Ethernet switch card used for internal shelf connection

  • MUX-32

Optical MUX 32 Channels

  • MXP-2.5G-10G

10G (4 * 2.5G) Muxponder card

  • MXP-MR-10DME

10 Gbps datamux with enhanced FEC

  • OPT-AMP-L

Optical preamplifier for L-band

  • OPT-BST

Optical booster amplifier

  • OPT-BST-L

Optical booster for L-band

  • OPT-EDFA-17

MAL-less EDFA Optical Amplifier - C-band - 17dB Gain

  • OPT-EDFA-24

MAL-less EDFA Optical Amplifier - C-band - 24dB Gain

  • OPT-PRE

Optical Preamplifier

  • OPT-RAMP-C

Raman pump amplifier C-band

  • OPT-RAMP-CE

An extended version of Raman pump amplifier

  • OPT-RAMP-COP

Raman COP card.

  • OPT-RAMP-CTP

Raman CTP card.

  • OPT-RAMP-E

Raman pump amplifier E-band

  • OSC-CSM

Optical Service Channel with Combiner/Separator Module

  • OSCM

Optical Service Channel Module

  • OTU2-XP

A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64

  • PIM-4

Pluggable interface module with 4 PPM slots

  • PP-4-SMR

Patch-Panel, 4 degrees, for SMR cards

  • PP-MESH-4

Patch-Panel, 4 degrees

  • PP-MESH-8

Patch-Panel, 8 degrees

  • PPM-1

Pluggable port module with 1-port SFP module

  • PSM

Protection Service Module card

  • PTF-4

Fabric card.

  • PTM-4

Line card.

  • PTSA

CPT 50 panel.

  • PTSYS- Fan-Out-Group

PTSYS Fan-Out-Group.

  • SHELF

Shelf entity

  • STM4

An interface card that supports one or more STM4 (622 Mbps) optical facilities

  • STM4-4

A four port STM4 card

  • STM4-IR-1

An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities

  • STM4-LR-1

An interface card that supports one long range STM4 (622 Mbps) optical facilities

  • STM4-SR-1

An interface card that supports one short range STM4 (622 Mbps) optical facilities

  • STM64-4

A four port STM64 card

  • STM64-LR-1

An interface card that supports one or more STM64 optical facilities

  • STM1

An interface card that supports multiple STM1 (155 Mbps) optical facilities

  • STM1-IR-4

An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities

  • STM1-SR-4

An interface card that supports four short range STM1 (155 Mbps) optical facilities

  • STM1ATM-IR-6

An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers

  • STM1IR-STM1SH-
    1310-8

An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G

  • STM1POS-SR-4

An interface card that supports four short range STM1 (155 Mbps) POS optical facilities

  • STM16

An interface card that supports one or more STM16 (10 Gbps) optical facilities

  • STM16-AS-1

An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot

  • STM16-ELR-1

An interface card that supports one short range STM16 (2.5 Gbps) optical facility

  • STM16-IR-1

An interface card that supports one intermediate range STM16 (10 Gbps) optical facility

  • STM16-LR-1

An interface card that supports one long range STM16 (10 Gbps) optical facility

  • STM16-SR-1

An interface card that supports one short range STM16 (10 Gbps) optical facilities

  • TCC

Timing, Communications, and Control card

  • TDC-CC

Coarse tunable dispersion compensation unit

  • TDC-FC

Fine tunable dispersion compensation unit

  • TXP-MR-10G

10G Multirate Transponder card

  • TXP-MR-2.5G

Multirate 2.5G Unprotected

  • TXPP-MR-2.5G

Multirate 2.5G Protected

  • UNKNOWN

Unknown equipment type

  • UNPROVISIONED

Unprovisioned equipment type

  • WSE

Wire Speed Encryption (WSE) card

  • XC-VXC-10G

XC-VXC-10G cross-connect card

  • XCVXL-10G

XC-VXL-10G cross-connect card

  • XCVXL-2.5G

XC-VXL-2.5G cross-connect card

<PPMTYPE>

Identifies the pluggable port module type. This parameter can take only one value.

  • PPM-1

Single-port PPM

<PPMNUM>

Identifies the pluggable port module number. This parameter is an Integer.

  • 1

PPM No. 1

  • 2

PPM No. 2

  • 3

PPM No. 3

  • 4

PPM No. 4

  • 5

PPM No. 5

  • 6

PPM No. 6

  • 7

PPM No. 7

  • 8

PPM No. 8

  • 9

PPM No. 9

  • 10

PPM No. 10

  • 11

PPM No. 11

  • 12

PPM No. 12

<PORTNUM>

Identifies the port number, which is used on the entity port with PPM. This para meter is an integer.

  • 1

Port No. 1

<PORTRATE>

Identifies the port rate, which is used to specify the port rate of the multi-rate card.

  • STM1

STM-1 rate

  • STM4

STM-4 rate

  • STM16

STM-16 rate