Guest

Cisco uBR10000 Series Universal Broadband Routers

Field Notice: FN - 63750 - UBR10K Cards Might Fail to Boot After Software Upgrade or Power Cycle - Fix on Failure

Field Notice: FN - 63750 - UBR10K Cards Might Fail to Boot After Software Upgrade or Power Cycle - Fix on Failure

March 3, 2014


NOTICE:

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.

Revision History

Revision Date Comment
1.0
03-MAR-2014
Initial Public Release

Products Affected

Product Line
Products Affected
UBR10K   
ESR-HH-1GE(=)  
UBR10-2XDS-SIP(=) 
UBR10-MC5X20H-D(=) 

Problem Description

The Cisco UBR10K linecards (listed in the Products Affected section) might fail to boot up after a software upgrade or other user action where the board requires a power cycle operation.

Background

Cisco has been working with some customers on an issue related to memory components manufactured by a single supplier between 2005 and 2010. These memory components are widely used across the industry and are included in a number of Cisco products. 

Although the majority of Cisco products using these components are experiencing field failure rates below expected levels, some components may fail earlier than anticipated. A handful of our customers have recently experienced a higher number of failures, leading us to change our approach to managing this issue. 

While other vendors have chosen to address this issue in different ways, Cisco believes its approach is the best course of action for its customers. Despite the cost, we are demonstrating that we always make customer satisfaction a top priority. Customers can learn more about this topic at Memory Component Issue web page.

A degraded component will not affect the ongoing operation of a device, but will be exposed by a subsequent power cycle event. This event will result in a hard failure of the device, which cannot be recovered by a reboot or additional power cycle. For these reasons, additional caution is recommended for operational activities requiring the simultaneous power cycling of multiple devices. This issue has been observed most commonly on devices that have been in service for 24 months or more.

Problem Symptoms

If the UBR10K linecard (listed in the Products Affected section) has been in continuous operation for approximately 24 months, then the hardware might fail to boot up due to memory failure during a power cycle event. This is caused by one or more of these actions:

  • Upgrade the software
  • Reload the entire product
  • Reload after installation
  • Online Insertion Removal/Replacement (OIR)
  • Cable power on/off command

Note: This issue does not affect boards while the boards are in operation. The board failure might occur after one or more of the actions listed are executed.

This is the linecard symptom that is observed:

UBR10-MC5X20H-D(=) 

The console message or the show log command output indicates this string (where X is a number):

%CLCJIB-X-SDRAMUECCER

Workaround/Solution

Fix on Failure Replacement Guidelines: Request RMA product and memory modules through normal service support channels. 

In order to assist with determining the hardware part(s) that might require replacement, consult the error messages documented in the Problem Symptoms section. 

For assistance with replacement part disposition, reference this table:

Please refer to the Replacement of SODIMM on the Cisco uBR10-MC5X20H Line Card Cisco article in order to replace the Memory Modules on this product. 

How To Identify Hardware Levels

Enter the show inventory command in order to obtain the Product ID (PID) of the UBR10K linecard. If the CLI is not available, physically inspect the linecard in order to locate the PID.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: