Guest

Cisco Unified MeetingPlace

Field Notice: MeetingPlace Server 8112 Cannot Add Meeting Category After a Conversion


May 19, 2004


Products Affected

Product

Comments

Cisco MeetingPlace Server 8112 (M3)

Versions 5.0.2q and 5.1.0x

Problem Description

A duplicate record error is given when attempting to add a meeting category. This is caused by the "mpconvert init" procedure keeping the meeting category record.

Apply the corresponding mpconvert and convpci hot fix before proceeding with a conversion (before running mpconvert init).

Problem Symptoms

Customer will not be able to add meeting category after a conversion.

Workaround/Solution

WORKAROUND:

None

SOLUTION:

A hot fix for 5.1.0 mpconvert and convpci modules is available in hot fix release 5.1.0ad and above. Hot fix for 5.0.2 mpconvert and convpci modules is available on hot fix release 5.0.2x and above.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:

Receive Email Notification For New Field Notices

Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.