Guest

CGR 1240 (Pole Mount)

CGR 1120 (Din-Rail Mount)

Expand all

Physical Specifications

Dimensions (H x W x D)30.5 cm x 23 cm x 21.6 cm
12 in. x 9.0 in. x 8.5 in.
8.9 cm x 22.9 cm x 20 cm
3.5 in. x 9.0 in. x 7.8 in.
Rack height-2 RU
Rack mount 19 inches-Yes, using the 19-inch rack tray
Pole mountYesNo
Wall mountYesYes
Din-rail mountNoYes
Typical weight fully configured23 lbs (10.4 kg) 
Unit weight includes base chassis with four communication modules, AC power supply, and 8-Amp-hr battery backup unit
8 lbs (3.6 kg)
Unit weight includes base chassis with two communication modules and integrated AC/DC power supply
Operating temperature3-40 to 70°C (-40 to 158°F) with type test to 85°C (185°F) for 16 hours-25 to 60°C (-25 to 140°F) with type test up to 85°C (185°F) for 16 hours

Communication Modules

IEEE 802.15.4g WPANYesYes
4G LTEYesYes
3.5G (AT&T and non-U.S. version) HSPA+/UMTS/GSM/GPRS/EDGEYesYes
CDMA EV-DO Rev A/0/1xRTT  (Sprint, Verizon, other carriers)YesYes
IEEE 802.16e- 2.3 GHz WiMAXYesYes
IEEE 802.16e- 3.6 GHz 2 WiMAXYesYes
IEEE 802.16e- 1.8 GHz 2 WiMAXYesYes
IEEE 802.16e- 2.5 GHz 3 WiMAXYesYes
IEEE 802.16e- 3.3 GHz 3 WiMAXYesYes

On-Board Interfaces

Gigabit Ethernet combination ports (10/100/1000 copper, 100/1000 SFP)22
10 /100 Fast Ethernet copper ports46
Wi-Fi (IEEE 802.11 b/g/n)YesYes
Serial (RS-232/RS-485) 222
GPS for locationYesYes
IRIG-B 3BNC connectorNo
Digital alarm inputs 324
Digital alarm outputs 321
USB Type A host ports 321
Console and AUX port  (RJ-45)11
SD flash slot (default memory)1 (2 GB)1 (2 GB)

Power Options

Power supplyAC power supply:
100 - 240 VAC
Integrated AC/DC power supply:
3-phase AC power supply: 100 - 240 VAC
9-60 VDC
Battery backup options4,5Integrated battery backup unit (BBU), smart charging, and monitoring:
Base BBU: 5 A-hr
Estimated Run time: 4 hours at nominal temperature, 3 hours at low temperature with battery heaters enabled
Estimated life: 5 years
Extra capacity BBU: 10 A-hr
Estimated Run time: 8 hours at nominal temperature, 6 hours at low temperature with battery heaters enabled
Estimated life: 5 years
Extended life BBU: 15 A-hr
Estimated Run time: 12 hours at nominal temperature, 9 hours at low temperature with battery heaters enabled
Estimated life: 5 years
-
Power options for third-party radiosThe CGR 1240 provides support for powering third-party radios:
Voltage output: 12VDC ± 5%
Power output: Up to 20 W depending upon router configuration
-