Guest

Cisco 1000 Series Connected Grid Routers

Compare Models

Model Comparison for Cisco 1000 Series Connected Grid Routers (CGR)

 

CGR 1240 (Pole Mount)

CGR 1120 (Din-Rail Mount)

 

Physical Specifications

Dimensions (H x W x D)

30.5 cm x 23 cm x 21.6 cm
12 in. x 9.0 in. x 8.5 in.

8.9 cm x 22.9 cm x 20 cm
3.5 in. x 9.0 in. x 7.8 in.

Rack height

-

2 RU

Rack mount 19 inches

-

Yes, using the 19-inch rack tray

Pole mount

Yes

No

Wall mount

Yes

Yes

Din-rail mount

No

Yes

Typical weight fully configured

23 lbs (10.4 kg) 
Unit weight includes base chassis with four communication modules, AC power supply, and 8-Amp-hr battery backup unit

8 lbs (3.6 kg)
Unit weight includes base chassis with two communication modules and integrated AC/DC power supply

Operating temperature3

-40 to 70°C (-40 to 158°F) with type test to 85°C (185°F) for 16 hours

-25 to 60°C (-25 to 140°F) with type test up to 85°C (185°F) for 16 hours

Communication Modules

IEEE 802.15.4g WPAN

Yes

Yes

4G LTE

Yes

Yes

3.5G (AT&T and non-U.S. version) HSPA+/UMTS/GSM/GPRS/EDGE

Yes

Yes

CDMA EV-DO Rev A/0/1xRTT  (Sprint, Verizon, other carriers)

Yes

Yes

IEEE 802.16e- 2.3 GHz WiMAX

Yes

Yes

IEEE 802.16e- 3.6 GHz 2 WiMAX

Yes

Yes

IEEE 802.16e- 1.8 GHz 2 WiMAX

Yes

Yes

IEEE 802.16e- 2.5 GHz 3 WiMAX

Yes

Yes

IEEE 802.16e- 3.3 GHz 3 WiMAX

Yes

Yes

On-Board Interfaces  

Gigabit Ethernet combination ports (10/100/1000 copper, 100/1000 SFP)

2

2

10 /100 Fast Ethernet copper ports

4

6

Wi-Fi (IEEE 802.11 b/g/n)

Yes

Yes

Serial (RS-232/RS-485) 2

2

2

GPS for location

Yes

Yes

IRIG-B 3

BNC connector

No

Digital alarm inputs 3

2

4

Digital alarm outputs 3

2

1

USB Type A host ports 3

2

1

Console and AUX port  (RJ-45)

1

1

SD flash slot (default memory)

1 (2 GB)

1 (2 GB)

Power Options

Power supply

AC power supply:

  • 100 - 240 VAC

Integrated AC/DC power supply:

  • 3-phase AC power supply: 100 - 240 VAC
  • 9-60 VDC

Battery backup options4,5

Integrated battery backup unit (BBU), smart charging, and monitoring:

  • Base BBU: 8 Amp-hr
    • Run time: 5 hours
    • Estimated life: 5 years
  • Extra capacity BBU: 12 Amp-Hr
    • Run time: 8 hours
    • Estimated life: 5 years
  • Extended life BBU: 12 Amp-Hr
    • Run time: 5 hours
    • Estimated life: 10 years

-

Power options for third-party radios

The CGR 1240 provides support for powering third-party radios:

  • Voltage output: 12VDC ± 5%
  • Power output: Up to 20 W depending upon router configuration

-