简介
本文描述如何去除和替换在思科聚合服务路由器(ASR)的不同的卡5500个制作机箱。必须采取注意事项,当您从一个ACTIVE机箱时替换或去除所有卡,因为此操作也许影响真实数据流。
Caution:每次请勿执行在超过一(1)卡的卡维护在一个ACTIVE供给电源的制作机箱。因为这将导致数据流损失,请勿从机箱每次去除超过一(1)卡。跟随所有注意事项。
ASR 5500卡类型
有组成ASR 5500机箱卡的四种类型。为了看到您的机箱如何填充,请输入此命令:
[local]ASR5500# show card table
Slot Card Type Oper State SPOF Attach
---------- ---------------------------------------- ------------- ---- ------
1: DPC Data Processing Card Active No
2: DPC Data Processing Card Active No
3: DPC Universal Data Processing Card Active No
4: DPC None - -
5: MMIO Management & 20x10Gb I/O Card Active No
6: MMIO Management & 20x10Gb I/O Card Standby -
7: DPC None - -
8: DPC Universal Data Processing Card Standby -
9: DPC Data Processing Card Active No
10: DPC Data Processing Card Standby -
11: SSC System Status Card Active No
12: SSC System Status Card Active No
13: FSC None - -
14: FSC Fabric & 2x200GB Storage Card Active No
15: FSC Fabric & 2x200GB Storage Card Active No
16: FSC Fabric & 2x200GB Storage Card Active No
17: FSC Fabric & 2x200GB Storage Card Active No
18: FSC None - -
19: NONE None - -
20: NONE None - -
前置卡
结构存储设备卡德(FSC)
机箱能有最多四个FSC卡。六slot为机箱保留。Slot 13到18是为FSC卡。目前思科在Slot 14到17使用四个FSC卡。
系统状态卡德(SSC)
机箱能有最多在Slot 11和12的两个SSC卡。两个卡在一个标准的机箱通常安装。
后卡
数据处理卡德(DPC)
机箱在一个充分填充的机箱能有最多在Slot 1到4和7个到10.所有卡的八个DPC卡通常安装。
管理& I/O卡德(减少)
机箱能有最多在Slot 5和6.的两个减少卡。两个卡在一个完全冗余机箱通常安装。
前提对于卡更换
在您继续进行在此方法概述的步骤步骤(MOP)前,请获取此重要信息,万一必须取消您的更改:
减少卡更换
Note:只要单卡到时,替换在单个维护窗口期间,此步骤可以使用为了替换多个卡。必须为替换的每个卡仿效此做法全文,一个卡每次。从实际里面同时拉多个卡,制作机箱是不可行的。
- 在您继续前,请完成在前提描述的所有预习功课工作对于卡更换部分。
- 如果将替换的卡当前活跃的,请执行从该激活的卡的一个卡切换到一张可用的备用卡片。使用显示打牌用之轻便小桌为了确定卡状态。
[local]ASR5500# card switch from <active slot> to <standby slot>
- 使用显示打牌用之轻便小桌为了验证卡切换是成功的。
- 如果适用,在您取消他们前,请识别并且标记所有电缆。
- 拔出卡(请确保弹出装置互锁被脱离,当您拔出卡)时。
- 插入新的卡。对于一个减少卡,必须交换在减少的安全数字高容量(SDHC)作为此进程一部分,卡。在MIO/UMIO的SDHC内存卡出现作为在CLI的/flash驱动。它存储配置数据,包括引导程序优先级设置。
Caution:必须在ESD SAFE工作站执行SDHC卡的删除和更换。当您处理SDHC卡和MIO/UMIO卡时,请观察ESD注意事项。而且,请确保SD卡进入旧有减少删除的各自新建的减少卡(在新的活动减少卡应该插入从旧有活动减少卡的SD卡;同样申请对SD从暂挂减少卡的卡)。
- 在已经删除减少卡,请找出在电路卡的底部背面角落的SDHC卡。SDHC卡位于推送推送类型持有人。使用您的指尖,请推送SDHC卡内部的后刃,直到您听到单击。发布您的finger,并且卡将弹出在持有人外面。去除卡并且安全存储它在旁边。
- SDHC卡位于推送推送类型持有人。使用您的指尖,请推送SDHC卡内部的后刃,直到您听到单击。发布您的finger,并且卡将弹出在持有人外面。去除卡并且安全存储它在旁边。
- 在更换MIO/UMIO,请找出SDHC持卡人并且去除SDHC卡。为了便于测试该卡包含仅基本配置;当您返回电路卡对思科时,请插入它到已经删除卡在之前。
- 在更换MIO/UMIO,请插入从已经删除MIO/UMIO删除的SDHC卡。使用您的指尖,请推送SDHC卡内部,直到您听到单击并且发布您的finger。这完成SDHC卡换出步骤。
- 如果适用,请建立对新的卡的电缆连接使用在步骤收集的标识信息4。
- 同步文件系统:
[local]ASR5500# filesystem synchronize all -noconfirm
- 如果理想,请执行卡切换为了做新的卡激活。使用显示打牌用之轻便小桌为了确定卡状态。
[local]ASR5500# card switch from <active slot> to <standby slot>
- 使用显示打牌用之轻便小桌为了验证卡切换是成功的。
- 重复健康检查为了保证那里是没有问题。
DPC卡更换
- 在您继续前,请完成在前提描述的所有预习功课工作对于卡更换部分。
- 如果将替换的卡当前活跃的,请执行从激活的卡的卡切换到一张可用的备用卡片。使用显示打牌用之轻便小桌为了确定卡状态。
[local]ASR5500# card switch from <active slot> to <standby slot>
- 使用显示打牌用之轻便小桌为了验证卡切换是成功的。
- 拔出卡(请确保弹出装置互锁被脱离,当您拔出卡)时。
- 插入新的卡。
- 如果理想,请执行卡切换为了做新的卡激活。使用显示打牌用之轻便小桌为了确定卡状态。
从<active slot>的[local]ASR5500#卡交换到<standby slot>
- 使用显示打牌用之轻便小桌为了验证卡切换是成功的。
- 重复健康检查为了保证没有问题。
FSC卡更换
- 在您继续前,请完成在前提描述的所有预习功课工作对于卡更换部分。
- 检查Redundant Array of Independent Disk (RAID)阵列的当前状态。
[local]ASR5500# show hd raid
- 通常RAID状态是可用的,降低是没有,并且所有卡应该在in-sync。
- 如果降低是,注释哪些卡在in-sync。
- 您应该有至少三个FSC卡In-sync为了维护存储阵列的数据完整性。
Note:降低的阵列:如果RAID驱动降低,含义slot失败,并且硬盘驱动器(HD)在该slot对RAID控制器不是可用的。如果您替换的FSC是相同的象不在in-sync的组件,您能继续更换。否则,请终止维护;您将需要其他FSC首先替换发生故障的卡,然后替换最初被安排于更换的FSC。
[local]ASR5500# show hd raid ver
Friday November 07 10:10:12 CST 2014
HD RAID:
State : Available (clean)
Degraded : No
UUID : 34259b4e:4ee9add9:4d84f2ab:21bef1d5
Size : 1.2TB (1200000073728 bytes)
Action : Idle
Card 14
State : In-sync card
Created : Tue Feb 11 13:47:34 2014
Updated : Fri Nov 7 10:09:43 2014
Events : 74778
Description : FSC14 LLYYWWSSSSS
Size : 400GB (400096755712 bytes)
Disk hd14a
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Disk hd14b
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Card 15
State : In-sync card
Created : Tue Feb 11 13:47:34 2014
Updated : Fri Nov 7 10:09:43 2014
Events : 74778
Description : FSC15 LLYYWWSSSSSS
Size : 400GB (400096755712 bytes)
Disk hd15a
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Disk hd15b
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Card 16
State : In-sync card
Created : Tue Feb 11 13:47:34 2014
Updated : Fri Nov 7 10:09:43 2014
Events : 74778
Description : FSC16 LLYYWWSSSSSS
Size : 400GB (400096755712 bytes)
Disk hd16a
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Disk hd16b
State : In-sync component
Created : Tue Feb 11 13:47:30 2014
Updated : Tue Feb 11 13:47:30 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Card 17
State : In-sync card
Created : Tue Feb 11 13:47:34 2014
Updated : Fri Nov 7 10:09:43 2014
Events : 74778
Description : FSC17 LLYYWWSSSSSS
Size : 400GB (400096755712 bytes)
Disk hd17a
State : In-sync component
Created : Fri Oct 31 08:57:49 2014
Updated : Fri Oct 31 08:57:49 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
Disk hd17b
State : In-sync component
Created : Fri Oct 31 08:57:49 2014
Updated : Fri Oct 31 08:57:49 2014
Events : 0
Model : STEC Z16IZF2D-200UCT E12A
Serial Number : LLYYWWSSSSSS
Size : 200GB (200049647616 bytes)
- 如果RAID是健康的,您能继续卡更换;如果RAID在一降低的状态,请继续,只有当您必须替换的卡已经脱机。
- 当您去除FSC卡, RAID变得降低。替换仅单个FSC。如果替换超过一个FSC,您丢失数据。
- 执行一个健康检查为了保证替换的卡。
[local]ASR5500# show card diag <active slot>
- 使用显示hd袭击为了检查RAID驱动的状况。如果状态重建,请继续等待RAID驱动重建。这能花费一个小时。
- 如果RAID驱动不重建,您必须手工开始重建进程。作为管理员,请运行:
[local]ASR5500# hd raid overwrite <hd slot>
- 请使用您替换卡的hdxx插槽编号。例如, hd14。
- 使用显示hd袭击为了复校RAID驱动的状况,应该重建。继续等待RAID驱动重建。这能花费一个小时。
- 继续使用显示hd袭击为了周期地检查直到完整的状态。当RAID重建完成时,请确保卡回到In-sync,并且RAID状态再次是可用的。
- 重复健康检查为了保证那里是没有问题。
SSC卡更换
- 在您继续前,请完成在前提描述的所有预习功课工作对于卡更换部分。
- 如果将替换的卡当前活跃的,请进行从CLI的卡止步不前为了放置脱机的卡。使用显示打牌用之轻便小桌为了确定卡状态。
[local]ASR5500# show card table
[local]ASR5500# card halt <active slot>
- 使用显示打牌用之轻便小桌为了验证卡脱机。
- 如果适用,在您取消所有电缆前,请识别并且标记所有电缆。
- 拔出卡(请确保弹出装置互锁被脱离,当您拔出卡)时。
- 插入新的卡。
- 执行在替换的卡的一个健康检查。
[local]ASR5500# show card diag <active slot>
后续步骤
如果此信息不解决您的问题,则请打开与Cisco TAC团队的一服务请求有此数据的附加到案件:
- SSD -请显示支持详细信息对文件/flash/ <ssd-file-name>压缩- noconfirm
- 简单网络管理协议(SNMP)陷阱- show SNMP陷阱历史记录verbose
- Syslog两个小时和在事件以后的以前两个小时-请显示日志
相关信息