简介
本文描述从一个来源Cisco安全管理设备(SMA)的备份过程对目标SMA为什么失效与错误“服务器拒绝的漫游- [Errno 32]破裂的导管”。
背景信息
保证这些限制和需求备份的完成:
- 同样AsyncOS版本
- 在网络的目标SMA
- 设备之间的通信与安全壳SSH
- 目标设备的产能是同样或极大的
- 仅一备份过程每次运行
当您从一个SMA的备份数据到另一个SMA,备份出故障。请参阅错误消息出现在备份日志此处:
Wed Jun 11 15:40:07 2014 Warning: BACKUP: Errors: ssync errors during backup to
10.7.72.15, Reason: Server denied roaming - Write failed: Broken pipe - - errors:
"[Errno 32] Broken pipe" - Wed Jun 11 15:40:40 2014 Warning: BACKUP:
Errors: ssync errors during backup to
10.7.72.15, Reason: Server denied roaming - Write failed: Broken pipe - errors:
"[Errno 32] Broken pipe"
Wed Jun 11 15:40:40 2014 Warning: BACKUP: Failed: phase One for the service: isq
Wed Jun 11 15:40:57 2014 Critical: BACKUP: FAILED: Backup job(migrace) for
mgmt2.iol.cz scheduled to start at 11 June 2014, 15:34 to 10.7.72.15 failed with errors
- tracking:Server denied roaming - Write failed: Broken pipe - - errors:
"[Errno 32] Broken pipe"
isq:Server denied roaming - Write failed: Broken pipe - - errors: "[Errno 32]
Broken pipe" - isq:Server denied roaming - Write failed: Broken pipe - errors:
"[Errno 32] Broken pipe".
错误[Errno 32]破裂的导管错误典型地发生,当系统尝试继续和使用已经关闭的连接。使用CLI,检查所有潜在的第2层问题并且查看从etherconfig >媒体的结果和netstat -在两的ni SMAs。
source_SMA> etherconfig
Ethernet interfaces:
1. Data 1 (100baseTX full-duplex: ) 00:1e:c9:51:9a:20
2. Data 2 (Autoselect: ) 00:1e:c9:51:9a:22
3. Management (100baseTX full-duplex: ) 00:10:18:34:d4:bf
source_SMA> netstat -ni
Name Mtu Network Address Ipkts Ierrs Idrop Opkts Oerrs Coll
Data 2 1500 < Link#1 > 00:1e:c9:51:9a:22 0 0 0 0 0 0
Mana~t 1500 < Link#2 > 00:10:18:34:d4:bf 11081531 0 0 11779530 0 0
Mana~t 1500 10.7.72.0 10.7.72.18 1746167 - - 1870789 - -
Data 1 1500 < Link#3 > 00:1e:c9:51:9a:20 24323550 0 0 23750730 0 0
Data 1 1500 192.168.30.0 192.168.30.252 6139415 - - 6089676 - -
target_SMA> etherconfig
Ethernet interfaces:
1. Data 1 (100baseTX full-duplex: ) d4:ae:52:87:f4:44
2. Data 2 (Autoselect: ) d4:ae:52:87:f4:46
3. Data 3 (Autoselect: ) d4:ae:52:87:f4:48
4. Management (100baseTX full-duplex: ) d4:ae:52:87:f4:42
target_SMA> netstat -ni
Name Mtu Network Address Ipkts Ierrs Idrop Opkts Oerrs Coll
Mana~t 1500 < Link#1 > d4:ae:52:87:f4:42 122700 62 0 12289 0 0
Mana~t 1500 10.7.72.0 10.7.72.15 38051 - - 1033 - -
Data 1 1500 < Link#2 > d4:ae:52:87:f4:44 154093 1235 0 54906 0 0
Data 1 1500 192.168.30.0 192.168.30.245 45116 - - 50445 - -
Data 2 1500 < Link#3 > d4:ae:52:87:f4:46 0 0 0 0 0 0
Data 3 1500 < Link#4 > d4:ae:52:87:f4:48 0 0 0 0 0 0
接收的设备(target_SMA)显示在管理和数据1以太网接口的输入错误。如果检查交换机target_SMA连接对,您看到问题是在SMA和Cisco交换机之间的一不兼容。尽管接口速度和双工自动检测,两个设备无法选择同样设置。SMA检测100baseTX全双工,但是在交换机,有仅100baseTX半双工,并且必须配置到100baseTX全双工。