06-21-2019 11:10:31.738 +0200 ERROR TcpInputProc - Encountered Streaming S2S error=Cannot register
new_channel="source::perfdata|host:: xxxx.xx.xxx.xxx.xx (https://xxxxx.xx.xxxx.xxx.xx/) |sourcetype:
:nmon_data|145804": desired_field_count=14 conflicts with existing_field_count=0 for data received
from src=10.121.200.154:50626.
S2S通信可能与nmon和IIS的接收没有直接关系,TcpInputProc等组件是报告网络信息(例如S2S协议消息)的日志通道之一。
发送已处理数据时,有若干事件报告来自HF的TcpOutputProc(TCP输出处理器和FD)与索引器x.x.x.x的连接超时。
它开始报告连接被拒绝的警告,最后连接失败。
WARN TcpOutputFd - Connect to x.x.x.x:10101 failed. Connection refused
ERROR TcpOutputFd - Connection to host=x.x.x.x:10101 failed
WARN TcpOutputFd - Connect to x.x.x.x:10101 failed. Connection refused
ERROR TcpOutputFd - Connection to host=x.x.x.x:10101 failed
WARN TcpOutputFd - Connect to x.x.x.x:10101 failed. Connection refused
WARN TcpOutputProc - Cooked connection to ip=x.x.x.x:10101 timed out
WARN TcpOutputProc - Cooked connection to ip=x.x.x.x:10101 timed out
WARN TcpOutputProc - Cooked connection to ip=x.x.x.x:10101 timed out
当Splunk需要一些字段,但收到错误的编号(在本例中为0)时,可能会触发此错误消息。这可能是由于缺少通信、网络或资源繁忙造成的。
的
作为TCPOuputProc和TcpOutputFd组件,输出处理器负责管理将数据转发到已配置的服务器:端口,主要由UF和HF使用。它们管理TCP端口上的文件描述符并执行读取/写入等操作。
当Splunk需要一些字段并且收到错误的数字(在本例中为0)时,可能会触发S2S(splunk to splunk)错误消息。这可能是因为资源繁忙、I/O没有空间写入数据或通常的网络波动而导致通信不足所致。