Table Of Contents
Viewing and Responding to Alarms
Viewing and Responding to Alarms Using Physical Switch Controls
Displaying Alarm Reports in the CLI
Displaying Line Alarms on Service Modules
Displaying Log File Information
Viewing and Responding to Alarms
Cisco MGX switches display alarm information about the switch cards and store this information inside the switch. This chapter describes how to interpret the alarm LEDs on the switch and how to obtain alarm reports through the CLI.
Viewing and Responding to Alarms Using Physical Switch Controls
All cards have LEDs for viewing alarm status and switches for responding to alarms. The "Illustrated Card List" chapter in the Cisco MGX 8800/8900 Hardware Installation Guide, Releases 2 - 5.1 describes the LEDs for all cards that can be installed in the MGX 8850 (PXM1E/PXM45), MGX 8950, and MGX 8830 switches.
Note Although there are LEDs for critical, major, and minor alarms on the PXM45 and PXM1E cards, only one of these LEDs is set to "on" when multiple alarms are active. The switch always displays the status of the most severe alarm. Critical alarms are the most severe, and minor alarms are the least severe. If there were 2 major alarms and 10 minor alarms, the switch would set the major alarm LED to on.
Displaying Alarm Reports in the CLI
You can use a CLI session to view the status of node alarms. Alarms are reported in the following categories:
•Node alarms
•Clock alarms
•Switching alarms (on MGX 8850 (PXM45) and MGX 8950 switches only)
•Environment alarms
•Card alarms
•License alarms
The sections that follow describe how to display the different types of alarm reports.
Note The procedures in the following sections can be completed by users at all access levels.
Displaying Node Alarms
A node alarm report displays a summary report of all alarms on the node. To display node alarms, enter the following command:
M8830_CH.1.PXM.a > dspndalmsThe following example shows the node alarm report display.
M8830_CH.1.PXM.a > dspndalmsNode Alarm SummaryAlarm Type Critical Major Minor---------- -------- ------- -------Clock Alarms 0 0 0Switching Alarms 0 0 0Environment Alarms 0 0 0Card Alarms 3 2 0Node License Alarm 0 0 0Typically, you would start investigating alarms by displaying the node alarms. Once you have identified the area that is producing the alarms, you would enter additional commands to display detailed information on those alarms. The following sections describe how to display these detailed reports.
Displaying Clock Alarms
Cisco MGX switches monitor the quality of the clock sources. If the timing for a clock source strays beyond the tolerance thresholds, an alarm is reported. To view the clock alarms, enter the following command:
mgx8850a.2.PXM.a> dspclkalmsThe following is an example clock alarm report:
mgx8850a.2.PXM.a> dspclkalmsmgx8850a System Rev: 03.00 May. 06, 2002 22:47:36 GMTMGX8830 Node Alarm: MINORClock Manager Alarm Summary----------------------------NETWORK CLOCK ALARM : STANDBY LOST PRIMARY REFERENCE : MINORNETWORK CLOCK ALARM : STANDBY LOST SECONDARY REFERENCE : MINORCritical Major Minor000 000 002Displaying Switching Alarms
Switching alarms identify problems with the switching components within the switch. MGX 8850 (PXM45) and MGX 8950 support several commands that allow you to display switching alarms.
Note PXM1E do not support switching alarms. Therefore, the commands in this section do not apply to MGX 8850 (PXM1E) and MGX 8830 switches.
To display a report of all switching alarms, enter the following command:
M8850_LA.8.PXM.a > dspswalmsThe following example is a sample report showing no switching alarms.
M8850_LA.8.PXM.a > dspswalmsXBAR SWITCHING FABRIC ALARMS SUMMARYXbar Core Alarm Xbar Port Alarm Xbar Slot B/W alarmSlot No. Critical Major Minor Critical Major Minor Critical Major Minor------- -------- ----- ----- -------- ----- ----- -------- ----- -----01 0 0 0 0 0 0 0 0 002 0 0 0 0 0 0 0 0 003 0 0 0 0 0 0 0 0 004 0 0 0 0 0 0 0 0 005 0 0 0 0 0 0 0 0 006 0 0 0 0 0 0 0 0 007 -- -- -- -- -- -- -- -- --08 0 0 0 0 0 0 0 0 009 -- -- -- -- -- -- -- -- --10 0 0 0 0 0 0 0 0 011 0 0 0 0 0 0 0 0 012 0 0 0 0 0 0 0 0 013 -- -- -- -- -- -- -- -- --14 -- -- -- -- -- -- -- -- --To display additional information on switch alarms, enter the following commands:
•dspXbarPlaneAlms
•dspxbarslotbwalms
To display a report for xbar alarms, enter the following command:
M8850_NY.7.PXM.a > dspdevalms XBARCORE -pslot *The following display is an example xbar alarm report.
M8850_LA.8.PXM.a > dspdevalms XBARCORE -pslot *M8850_LA System Rev: 05.00 Apr. 13, 2004 18:24:37 GMTMGX8850 Node Alarm: MAJORXBAR CORE ALARM SEVERITY INFO SUMMARYFabric Slot / PlaneSlot 7/0 7/1 7/2 8/0 8/1 8/2---- ---- ---- ---- ---- ---- ----01 -- -- -- -- -- --02 -- -- -- -- -- --03 -- -- -- -- -- --04 -- -- -- -- -- --05 -- -- -- -- -- --06 -- -- -- -- -- --07 -- -- -- -- -- --08 -- -- -- -- -- --09 -- -- -- -- -- --10 -- -- -- -- -- --11 -- -- -- -- -- --12 -- -- -- -- -- --13 -- -- -- -- -- --14 -- -- -- -- -- --When the switch reports xbar alarms, you can use the troubleshooting commands in Table 11-1 to collect more information.
For more information on these commands, refer to the Cisco MGX 8800/8900 Series Command Reference, Release 5.1.
Displaying Environment Alarms
An environmental alarm report displays the alarm status and operating statistics for the switch power supplies and cooling fans. To display the environmental alarm report, enter the dspenvalms command as shown in the following example:
mgx8830a.2.PXM.a > dspenvalmsType <CR> to continue, Q<CR> to stop:mgx8830a System Rev: 03.00 May 06, 2002 23:40:57 GMTMGX8830 Node Alarm: MINORENVIRONMENTAL ALARM STATE INFO ^Notification DisabledAlarm Type Unit Threshold DataType Value State---------------- ---- -------------- -------- ---------- -------------Top Fan Tray 6 >= 2000 RPM 3654 NormalTop Fan Tray 7 >= 2000 RPM 3576 NormalTop Fan Tray 8 >= 2000 RPM 3468 NormalTop Fan Tray 9 >= 2000 RPM 3492 NormalBottom Fan Tray 1 >= 2000 RPM 0 MissingBottom Fan Tray 2 >= 2000 RPM 0 MissingBottom Fan Tray 3 >= 2000 RPM 0 MissingBottom Fan Tray 4 >= 2000 RPM 0 MissingBottom Fan Tray 5 >= 2000 RPM 0 MissingBottom Fan Tray 6 >= 2000 RPM 0 MissingBottom Fan Tray 7 >= 2000 RPM 0 MissingBottom Fan Tray 8 >= 2000 RPM 0 MissingBottom Fan Tray 9 >= 2000 RPM 0 Missing+5V Input 4.850^ to 5.150^ VoltsDC 5.036 Informational+3.3V Input 3.200^ to 3.400^ VoltsDC 3.298 InformationalType <CR> to continue, Q<CR> to stop:MGX8830 Node Alarm: MINORENVIRONMENTAL ALARM STATE INFO ^Notification DisabledAlarm Type Unit Threshold DataType Value State---------------- ---- -------------- -------- ---------- -------------Fan Tray 6 >= 2000 RPM 2766 NormalFan Tray 7 >= 2000 RPM 2676 NormalFan Tray 8 >= 2000 RPM 2610 Normal+5V Input 4.850^ to 5.150^ VoltsDC 4.997 Informational+3.3V Input 3.200^ to 3.400^ VoltsDC 3.259 InformationalCalibration VDC 0x7e^ to 0x82^ Other 0x80 InformationallDisplaying Card Alarms
A card alarm report can display the alarm status of all the cards within the node or the alarm status of a single card. To display card alarms, enter the following command at the PXM45 or PXM1E switch prompt:
mgx8830a.2.PXM.a> dspcdalms [slot]Replace [slot] with the number of the card for which you want to display alarms. If you omit the slot number, the switch displays the alarms for all cards in the node as shown in the following example:
M8830_CH.1.PXM.a > dspcdalmsCard Alarm SummarySlot Critical Major Minor || Slot Critical Major Minor---- -------- ------- ------- || ---- -------- ------- -------1 1 0 0 || 8 0 0 02 0 0 0 || 9 0 0 03 0 0 0 || 10 0 0 04 0 0 0 || 11 0 0 05 0 0 0 || 12 2 2 06 0 0 0 || 13 0 0 07 0 0 0 || 14 0 0 0Use dspcdalms <slot> to see more detail.The next example shows a card alarm report for an MPSM-T3E3-155 card in slot 12:
M8830_CH.1.PXM.a > dspcdalms 12Card Alarm SummaryAlarm Type Critical Major Minor---------- -------- ------- -------Hardware Alarm 0 0 0Card State Alarm 0 0 0Disk Alarm 0 0 0Diag Alarm 0 0 0License Alarm 0 0 0Resource Alarm 0 0 0SRM Alarm 0 0 0IMA Alarm 0 0 0MFR Alarm 1 0 0Line Alarm 0 0 0Path Alarm 2 0 0Port Alarm 0 0 0LMI Alarm 0 0 0Channel Alarm 0 2 0SAR Alarm 0 0 0Table 11-2 lists commands that you can enter to display additional information about alarms that appear in the dspcdalms report.
Displaying Line Alarms on Service Modules
The service modules generate line alarms when a loss of signal (LOS) alarm occurs.
Table 11-3 lists commands that you can enter to display information about line alarms on service modules.
For detailed information about line alarms on specific service modules, refer to that service module's configuration guide. The service module configuration guides are listed in Table 1-1.
Displaying IMA Alarms
Enter the dspimagrpalms command to display alarm state information for all IMA groups on the current PXM1E-16-T1E1 or AXSM-32-T1E1-E, as shown in the following example:
Unknown.7.PXM.a > dspimagrpalmsGroup Number : 2.1Alarm State : StartUp FeGroup Number : 2.2Alarm State : Other FailureEnter the dspimagrpalm <bay.group> command to display alarm state information for a specific IMA group. Replace bay with the number 1 to specify the lower bay, or 2 to specify the lower bay. Replace group with the IMA group whose alarm status you want to view.
In the following example, the user displays alarm information for the IMA group 2 in the lower bay.
Unknown.7.PXM.a > dspimagrpalm 2.2Group Number : 2.2Alarm State : Other FailureEnter the dspimalnkalms command to display alarm state information for all IMA links on the current PXM1E-16-T1E1 or AXSM-32-T1E1-E, as shown in the following example.
Unknown.7.PXM.a > dspimalnkalmsLink Number : 2.5Alarm State : Lif FailEnter the dspimalnkalm <bay.line> command to display alarm state information for a specific IMA link. Replace bay with the 2 to specify the lower bay. Replace line with number of the line whose alarm status you want to view.
Note On the PXM1E, the bay number is always 2.
In the following example, the user displays alarm information for the IMA group 5 in the lower bay.
Unknown.7.PXM.a > dspimalnkalm 2.5
Link Number : 2.5Alarm State : Lif Fail
Note The commands in this section apply to the AXSM-32-T1E1-E and the PXM1E-16-T1E1 only. For information on the commands used to display alarms on AUSM-8-T1E1/B cards, refer to the Cisco ATM Services (AUSM/MPSM) Configuration Guide and Command Reference for MGX Switches, Release 5.1.
Displaying License Alarms
Enter the dsplicalms command to display alarm state information for MPSM feature licenses. For example:
M8850_SF.8.PXM.a > dsplicalmsM8850_SF System Rev: 05.00 Oct. 14, 2004 20:15:08 GMTMGX8850 Node Alarm: CRITICALSlot Critical Major Minor || Slot Critical Major Minor---- -------- ------- ------- || ---- -------- ------- -------1 0 0 0 || 17 0 0 02 0 0 0 || 18 0 0 03 0 0 1 || 19 0 0 04 0 0 0 || 20 0 0 05 0 0 0 || 21 0 0 06 0 0 0 || 22 0 0 07 0 0 0 || 23 0 0 08 0 0 0 || 24 0 0 09 0 0 1 || 25 0 0 010 0 0 0 || 26 0 0 011 0 0 0 || 27 0 0 012 0 0 1 || 28 0 0 013 0 0 0 || 29 0 0 014 0 0 0 || 30 0 0 015 0 0 0 || 31 0 0 016 0 0 0 || 32 0 0 0M8850_SF.8.PXM.a >To display license information on all cards, enter the dspliccds command as shown in the following example:
M8830_CH.1.PXM.a > dspliccdsM8830_CH System Rev: 04.09 Mar. 08, 2004 09:33:59 GMTMGX8830 Node Alarm: CRITICALCard Lic Prov License AllocatedSlot Card Type Alarm Allowed Type Licenses---- ----------------- -------- ------- ----------- ---------3 -- -- -- -- 04 -- -- -- -- 05 -- -- -- -- 06 -- -- -- -- 07 -- -- -- -- 08 -- -- -- -- 09 -- -- -- -- 010 -- -- -- -- 011 -- -- -- -- 012 MPSM-T3E3-155 No Yes MultiSrvc 1Channelize 1RateControl 113 -- -- -- -- 014 -- -- -- -- 0To display license information on a specific card, enter the dspliccd command as shown in the following example:
M8830_CH.1.PXM.a > dspliccd 12M8830_CH System Rev: 04.09 Mar. 08, 2004 09:34:12 GMTMGX8830 Node Alarm: CRITICALCard License Alarm: NoneService Module Type: MPSM-T3E3-155Service Module Serial Number: SAD073504CTProvisioning Allowed: Yes=========================================================Allocated License Type Quantity-------------------- --------MultiSrvc 1Channelize 1RateControl 1=========================================================Programmed License Type Quantity-------------------- --------=========================================================Programmed License Registered : N/ALicense Registeration Node : --License Registeration Chassis Serial No: --Displaying Log File Information
Log files record switch events such as operator login and command entry. To view the contents of the current log, enter the following command at the PXM1E or PXM45 switch prompt:
mgx8830a.2.PXM.a> dsplog [-log <number>] [-mod moduleName] [-sev <number>] [-sl <slot>] [-task <taskName>] [-tge <MM/DD/YYYY-HH:MM:SS>] [-tle <MM/DD/YYYY-HH:MM:SS>]To display a list of archived log files, enter the following command:
mgx8830a.2.PXM.a> dsplogsThe log files are stored in the C:/LOG directory.