Cable and Port Specifications
This appendix provides the cable and port specifications, and includes the following sections:
Cables and Adapters Provided
The Cisco MDS 9700 Series accessory kit includes the following items:
- RJ-45 rollover cable
- RJ-45/DSUB F/F adapter—RJ-45 to DB-25 female DTE adapter (labeled “Terminal”)
- RJ-45/DSUB R/P adapter—RJ-45 to DB-25 male DCE adapter (labeled “Modem”)
Note
Additional cables and adapters can be ordered from your customer service representative.
Note
If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html
Console Port
The console port is an asynchronous RS-232 serial port with an RJ-45 connector. You can use the RJ-45 rollover cable and the RJ-45/DSUB F/F adapter or the RJ-45F PC terminal adapter to connect the console port to a computer running terminal emulation software.
Console Port Pinouts
Table 7-1 lists the pinouts for the console port on the Cisco MDS 9700 Series switch.
Table 7-1 Console Port Pinouts
|
|
1 |
RTS |
2 |
DTR |
3 |
TxD |
4 |
GND |
5 |
GND |
6 |
RxD |
7 |
DSR |
8 |
CTS |
Connecting the Console Port to a Computer Using the DB-25 Adapter
You can use the RJ-45 rollover cable and RJ-45/DSUB F/F adapter (labeled “Terminal”) to connect the console port to a computer running terminal emulation software. Table 7-2 lists the pinouts for the console port, the RJ-45 rollover cable, and the RJ-45/DSUB F/F adapter.
Table 7-2 Port Mode Signaling and Pinouts with the DB-25 Adapter
|
|
RJ4-5/DSUB F/F Terminal Adapter
|
|
|
|
|
|
|
RTS |
1 |
8 |
5 |
CTS |
DTR |
2 |
7 |
6 |
DSR |
TxD |
3 |
6 |
3 |
RxD |
GND |
4 |
5 |
7 |
GND |
GND |
5 |
4 |
7 |
GND |
RxD |
6 |
3 |
2 |
TxD |
DSR |
7 |
2 |
20 |
DTR |
CTS |
8 |
1 |
4 |
RTS |
MGMT 10/100/1000 Ethernet Port
The MGMT 10/100/1000 Ethernet port is an Ethernet port with an RJ-45 connector. You can use a modular, RJ-45, straight-through UTP cable to connect the management port to an external hub, switch, or router (see Figure 7-1).
Figure 7-1 RJ-45 Interface Cable Connector
Table 7-3 lists the connector pinouts and signal names for a 10/100/1000BASE-T management port (MDI) cable.
Note
The RJ-45 interface only uses pins 1, 2, 3, and 6.
Table 7-3 10/100/1000BASE-T Management Port Cable Pinout (MDI)
|
|
1 |
TD+ |
2 |
TD- |
3 |
RD+ |
6 |
RD– |
4 |
Not used |
5 |
Not used |
7 |
Not used |
8 |
Not used |
Figure 7-2 shows a schematic of the 10/100/1000BASE-T cable required to connect the management port to a switch or hub (not provided with the switch).
Figure 7-2 Twisted-Pair 10/100/1000BASE-T Cable Schematic
Supported Power Cords and Plugs
Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit having IEC 60320 C19 outlet receptacles.
Power Cords
The standard power cords have an IEC C19 connector on the end that plugs into the switch. The optional jumper power cords have an IEC C19 connector on the end that plugs into the switch, and an IEC C20 connector on the end that plugs into an IEC C19 outlet receptacle.
Note
Only the regular power cords or jumper power cords provided with the switch are supported.
Note
If you do not order the optional power cord with the system, you are responsible for selecting the appropriate power cord for the product. Using a non-compatible power cord with this product may result in electrical safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered with the system.
Table 7-4 lists the power cords for the Cisco MDS 9700 Series switch and provides their lengths in feet and meters.
Table 7-4 Power Cords for the MDS 9700 Series Switch
|
|
|
|
MDS 9710 - 3000W Power Supply |
Power Cord, 250VAC 20A NEMA, 6-20 Plug, USA |
13.12 |
4 |
Power Cord, 250VAC 20A NEMA L6-20 Twist Lock Plug, USA |
13.58 |
4.14 |
Power Cord, 250VAC 16A CEE 7/7 Plug, EU |
13.12 |
4 |
Power Cord, 250VAC 16A IEC 309 Plug, International |
13.58 |
4.14 |
Power Cord, 250VAC 16A SEV 1011 Plug, Switzerland |
8 |
2.44 |
Power Cord, 250VAC SABS 1661 Plug, South Africa |
14 |
4.27 |
Power Cord, 250VAC 16A SI16S3 Plug, Israel |
14 |
4.27 |
Power Cord 250VAC 16A, Src Plug EL224-C19, Brazil, |
14 |
4.27 |
Power Cord 250VAC 16A, Src Plug IR2073-C19, Argentina, |
14 |
4.27 |
Supported Plugs for 3000 W AC Power Supplies
Figure 7-3 shows the supported plugs for the 3000 W AC power supplies.
Figure 7-3 3000-W AC Power Supply Plugs
|
International ( 3000 W) IEC 309 (20 A) |
|
North America (locking) (3000 W) NEMA L6-20 plug (2 0A) |
|
Europe (3000 W) CEE 7/7 (16 A) |
|
Switzerland (3000 W) 23 G SEV 1011 (16 A) |
|
North America (non-locking) (3000) NEMA 6-20 plug (20 A) |
|
South Africa (3000 W) EL 208, SABS 164-1 (16 A) |
Figure 7-4 shows an additional plug that is supported for the 3000 W and 2500 W power supply, using 110 VAC.
Note
Using the plug in Figure 7-4 at 110 VAC results in 1450 W available to the system.
Figure 7-4 Additional Power Supply Plug Supported for 3000 W 110 VAC Only
|
NEMA 5-20P North American power cord product ID: CAB-7513AC 110 VAC (20 A) |
Power Supply AC Power Cords
Table 7-5 lists the specifications for the 3000 W AC power cords that are available for the AC-input power supply. Included in the table are references to illustrations of the power cords.
Table 7-5 Power Supply AC Power Cords
|
|
|
|
Power Cord
Reference
Illustration
|
North America/Japan |
CAB-9K2A-NA |
NEMA 5-20 |
20 A, 125 VAC |
Figure 7-5 |
US/Japan |
CAB-9K16A-US2 |
NMEA L6-20 |
16 A, 250 VAC |
Figure 7-6 |
Australia |
CAB-9K16A-AUS |
AU20S3 |
16 A, 250 VAC |
Figure 7-7 |
China |
CAB-9k16A-CH |
GB16C |
16 A, 250 VAC |
Figure 7-8 |
International |
CAB-9K16A-INT |
IEC 309 |
16A 250V AC |
Figure 7-9 |
Switzerland |
CAB-9K16A-SW |
SEV 5934 |
16 A 250 VAC |
Figure 7-10 |
Continental Europe |
CAB-9K16A-EU |
CEE7/7 |
16 A 250 VAC |
Figure 7-11 |
Cabinet Jumper Power Cord |
CAB-C19-CBN |
C 20-C19 |
16 A 250 VAC |
Figure 7-12 |
AC Power Cord Illustrations
This section contains the AC power cord illustrations. An AC power cord can be used with several power supplies. See the power supply specifications tables for the correct AC power cord illustrations for your power supply.
Figure 7-5 CAB-9K20A-NA
Figure 7-6 CAB-9K16A-US2
Figure 7-7 CAB-9K16A-AUS
Figure 7-8 CAB-9K16A-CH
Figure 7-9 CAB-9K16A-INT
Figure 7-10 CAB-9K16A-SW
Figure 7-11 CAB-9K16A-EU
Figure 7-12 CAB-C19-CBN