Guest

Cisco Catalyst 2960 ½Ã¸®Áî ½ºÀ§Ä¡

Cisco Catalyst 2960 Switches with LAN Lite Software

::: Cisco :::
Cisco Catalyst 2960 ½ºÀ§Ä¡(LAN Lite ¼ÒÇÁÆ®¿þ¾î Æ÷ÇÔ)
Cisco® Catalyst® 2960 ½Ã¸®Áî ½ºÀ§Ä¡(LAN Lite ¼ÒÇÁÆ®¿þ¾î Æ÷ÇÔ)´Â ¿£Æ®¸® ¼öÁØÀÇ ¹è¼±ÇÔÀ¸·Î ¼Ò±Ô¸ðÀÇ Áö»ç ³×Æ®¿öÅ©¿¡ PC °í¼Ó ÀÌ´õ³ÝÀ» ¿¬°áÇÏ´Â °íÁ¤µÈ ±¸¼ºÀÇ µ¶¸³Çü ½ºÀ§Ä¡ÀÔ´Ï´Ù. Cisco Catalyst 2960 LAN Lite ½Ã¸®Áî ½ºÀ§Ä¡¸¦ »ç¿ëÇÏ¸é ºñÁö´ÉÇü Çãºê ¹× °ü¸®µÇÁö ¾Ê´Â ½ºÀ§Ä¡¿¡¼­ È®ÀåÇü °ü¸® ³×Æ®¿öÅ©·Î ½±°Ô ÀüȯÇÒ ¼ö ÀÖ½À´Ï´Ù. LAN Lite Cisco IOS¢ç ¼ÒÇÁÆ®¿þ¾î´Â ¿£Æ®¸® ¼öÁØÀÇ º¸¾È, QoS ¹× °¡¿ë¼º ±â´ÉÀ» Á¦°øÇϸç, ³×Æ®¿öÅ© ÃѼÒÀ¯ºñ¿ë(TCO)À» ÁÙ¿©ÁÝ´Ï´Ù.
Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â ´ÙÀ½°ú °°Àº ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
  •  ±â°¡ºñÆ® ÀÌ´õ³Ý ¾÷¸µÅ© À¯¿¬¼ºÀ» À§ÇÑ ÀÌÁß ¸ñÀû ¾÷¸µÅ©¸¦ Á¦°øÇϹǷΠÄÚÆÛ(copper) ¾÷¸µÅ© ¶Ç´Â ÆÄ¾î¹ö(fiber) ¾÷¸µÅ©¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. °¢ ÀÌÁß ¸ñÀû ¾÷¸µÅ© Æ÷Æ®¿¡´Â 10/100/1000 ÀÌ´õ³Ý Æ÷Æ®¿Í SFP(Small Form-Factor Pluggable) ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®°¡ °¢°¢ Çϳª¾¿ ÀÖÀ¸¸ç, ÇÑ ¹ø¿¡ ÇϳªÀÇ Æ÷Æ®¸¸ Ȱ¼ºÈ­µË´Ï´Ù.
  •  È®ÀåÇü º¸¾È ³×Æ®¿öÅ© °ü¸®
  •  »ç¿ëÀÚ, Æ÷Æ® ¹× MAC ÁÖ¼Ò¸¦ ±â¹ÝÀ¸·Î ÇÏ´Â ±âº» NAC(Network Admission Control)
  •  Cisco Network Assistant ¼ÒÇÁÆ®¿þ¾î¸¦ »ç¿ëÇÏ¿© °£ÆíÇÑ ³×Æ®¿öÅ© ±¸¼º°ú Cisco IOS Software ¾÷µ¥ÀÌÆ® ¹× ¹®Á¦ ÇØ°á °¡´É
  •  Smartport¸¦ »ç¿ëÇÏ¿© ÀÚµ¿ ±¸¼º
  •  ¸µÅ© ¿¬°á ¹®Á¦ ¹× ÄÉÀ̺í Áø´ÜÀ» ÅëÇÑ Çâ»óµÈ ¹®Á¦ ÇØ°á ±â´É
  •  ¸ÖƼij½ºÆ® ¼­ºñ½º Áö¿ø ¹× QoS ±â´É Á¦°ø
  •  Á¦ÇÑÀûÀÎ Çϵå¿þ¾î º¸Áõ Á¦°ø
  •  Ãß°¡ ºñ¿ë ¾øÀÌ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® °¡´É
±×¸² 1. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡
Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â ´ÙÀ½°ú °°Àº ½ºÀ§Ä¡·Î ±¸¼ºµË´Ï´Ù(±×¸² 1 ÂüÁ¶).
  •  Cisco Catalyst 2960-24-S: ÀÌ´õ³Ý 10/100 Æ÷Æ® 24°³
  •  Cisco Catalyst 2960-24TC-S: ÀÌ´õ³Ý 10/100 Æ÷Æ® 24°³, ÀÌÁß ¸ñÀû ¾÷¸µÅ© Æ÷Æ®(10/100/1000BASE-T ¶Ç´Â SFP) 2°³
  •  Cisco Catalyst 2960-48TC-S: ÀÌ´õ³Ý 10/100 Æ÷Æ® 48°³ ¹× ÀÌÁß ¸ñÀû ¾÷¸µÅ© Æ÷Æ® 2°³
SFP ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®´Â Cisco 1000BASE-SX, 1000BASE-LX ¹× 100BASE-FX SFP ¼Û¼ö½Å±â ¹üÀ§¸¦ ¼ö¿ëÇÕ´Ï´Ù.
Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â ±â¾÷¿¡¼­ Áß¿äÇÑ Á¤º¸ÀÇ ±â¹ÐÀ» À¯ÁöÇϰí, Çã°¡ ¹ÞÁö ¾ÊÀº »ç¿ëÀÚÀÇ ³×Æ®¿öÅ© ħÀÔÀ» Â÷´ÜÇϸç, °³ÀÎ Á¤º¸¸¦ º¸È£Çϰí, ½Ã½ºÅÛÀÇ Áß´Ü ¾øÀÌ ¾÷¹«¸¦ Áö¼ÓÇÒ ¼ö ÀÖµµ·Ï º¸¾È ±â´ÉÀ» Áö¿øÇÕ´Ï´Ù.
Cisco IBNS(Identity-Based Networking Services) ¼Ö·ç¼ÇÀº ³×Æ®¿öÅ© ¿¬°á ¹× ¸®¼Ò½º º¸¾ÈÀ» À§ÇØ ÀÎÁõ, ¾×¼¼½º Á¦¾î ¹× º¸¾È Á¤Ã¥ °ü¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. Cisco IBNS¸¦ Cisco Catalyst 2960 LAN Lite ½Ã¸®Áî¿¡ ¹èÄ¡Çϸé Çã°¡ ¹ÞÁö ¾ÊÀº ¾×¼¼½º¸¦ Â÷´ÜÇϰí, »ç¿ëÀÚ°¡ ÁöÁ¤µÈ ±ÇÇѸ¸ »ç¿ëÇϵµ·Ï ÇÒ ¼ö ÀÖ½À´Ï´Ù. Áï, ³×Æ®¿öÅ© ¾×¼¼½º ¼öÁØÀ» º¸´Ù ¼¼ºÎÀûÀÌ°í µ¿ÀûÀ¸·Î °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. 802.1x Ç¥Áذú Cisco ACS(Secure Access Control Server)¸¦ »ç¿ëÇÏ¿© ³×Æ®¿öÅ© ¿¬°á À§Ä¡¿¡ »ó°ü¾øÀÌ ÀÎÁõÀ» ÅëÇØ VLANÀ» »ç¿ëÀÚ¿¡°Ô ÁöÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco ACS¸¦ ¼³Ä¡Çϸé IT ºÎ¼­´Â »ç¿ëÀÚÀÇ À̵¿¼º¿¡ Á¦¾à ¾øÀÌ °ü¸®»óÀÇ ºñ¿ëÀ» ÃÖ¼ÒÈ­Çϸ鼭 °­·ÂÇÑ º¸¾È Á¤Ã¥À» ±¸ÇöÇÒ ¼ö ÀÖ½À´Ï´Ù.
Æ÷Æ® º¸¾ÈÀ» ÅëÇØ ¿¬°áµÈ ÀÌ´õ³Ý ÀåÄ¡ÀÇ MAC ÁÖ¼Ò¿¡ ±â¹ÝÇÏ¿© ÀÌ´õ³Ý Æ÷Æ®¿¡ ´ëÇÑ ¾×¼¼½º¸¦ Á¦ÇÑÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ Æ÷Æ® º¸¾ÈÀº ½ºÀ§Ä¡ Æ÷Æ®¿¡ ³»ÀåµÈ Àüü ÀåÄ¡ ¼ö¸¦ Á¦ÇÑÇÔÀ¸·Î½á, ºÒ¹ý ¹«¼± ¾×¼¼½º ÁöÁ¡ ¶Ç´Â Çãºê¿¡ ´ëÇÑ À§ÇèÀ» ÁÙÀÏ »Ó ¾Æ´Ï¶ó MAC Ç÷¯µù(Flooding) °ø°ÝÀ¸·ÎºÎÅÍ ½ºÀ§Ä¡¸¦ º¸È£ÇØ ÁÝ´Ï´Ù.
MAC ÁÖ¼Ò Å뺸 ±â´ÉÀ» »ç¿ëÇÏ¿© ³×Æ®¿öÅ©¸¦ ¸ð´ÏÅÍÇÏ°í »ç¿ëÀÚ¸¦ ÃßÀûÇÒ ¼ö ÀÖ½À´Ï´Ù. ÀÌ ±â´ÉÀº »ç¿ëÀÚ°¡ ³×Æ®¿öÅ©¿¡ ¾ðÁ¦ ¾î´À À§Ä¡¿¡¼­ µé¾î¿Ô´ÂÁö¸¦ ³×Æ®¿öÅ© °ü¸®ÀÚ°¡ ¾Ë ¼ö ÀÖµµ·Ï °ü¸® ½ºÅ×À̼ǿ¡ °æ°í¸¦ º¸³À´Ï´Ù. SSHv2(Secure Shell Protocol Version 2) ¹× SNMPv3(Simple Network Management Protocol Version 3)Àº ¿î¿µ ¹× ³×Æ®¿öÅ© °ü¸® Á¤º¸¸¦ ¾ÏȣȭÇÏ¿© º¯Á¶ ¶Ç´Â µµÃ»À¸·ÎºÎÅÍ ³×Æ®¿öÅ©¸¦ º¸È£ÇÕ´Ï´Ù. TACACS+ ¶Ç´Â RADIUS ÀÎÁõÀ» ÅëÇØ ½ºÀ§Ä¡ÀÇ Áß¾Ó ÁýÁᫎ ¾×¼¼½º Á¦¾î°¡ Áö¿øµÇ¸ç ¹«´Ü »ç¿ëÀÚ°¡ ±¸¼ºÀ» º¯°æÇÏ´Â °ÍÀ» Á¦ÇÑÇÒ ¼ö ÀÖ½À´Ï´Ù. ¶ÇÇÑ ½ºÀ§Ä¡ ÀÚü¿¡ ·ÎÄà »ç¿ëÀÚ À̸§°ú ¾ÏÈ£ µ¥ÀÌÅͺ£À̽º¸¦ ±¸¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù. ½ºÀ§Ä¡ Äֿܼ¡¼­´Â 15°³ ¼öÁØÀÇ ÀÎÁõ ¹æ½ÄÀ», À¥ ±â¹Ý °ü¸® ÀÎÅÍÆäÀ̽º¿¡¼­´Â 2°³ ¼öÁØÀÇ ÀÎÁõ ¹æ½ÄÀ» ÅëÇØ ¼­·Î ´Ù¸¥ °ü¸®ÀÚ¿¡ ´ëÇØ ¼­·Î ´Ù¸¥ ¼öÁØÀÇ ±¸¼º ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡¿¡´Â Layer 2 ³×Æ®¿öÅ©ÀÇ °¡¿ë¼º ±Ø´ëÈ­¸¦ À§ÇØ °í¾ÈµÈ STP(Spanning Tree Protocol) °­È­ ¹öÀüÀÇ Àüü Á¦Ç°±º°ú ¸ÖƼij½ºÆ® ÇÊÅ͸µÀ» ÅëÇØ ³×Æ®¿öÅ© È®À强°ú °í°¡¿ë¼ºÀ» Á¦°øÇÏ´Â ±â´ÉÀÌ Æ÷ÇԵǾî ÀÖ½À´Ï´Ù.
PVST+(Per-VLAN Spanning Tree Plus), UplinkFast ¹× PortFast¿Í °°Àº Ç¥ÁØ ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ¿¡ ´ëÇÑ Çâ»óµÈ ±â´ÉÀ» ÅëÇØ ³×Æ®¿öÅ© ´Ù¿îÇö»ó ¾øÀÌ °¡µ¿½Ã°£À» ±Ø´ëÈ­ÇÒ ¼ö ÀÖ½À´Ï´Ù. PVST+°¡ ¸®´ø´ø½ÃÇü ¸µÅ©»ó¿¡ Layer 2 ·Îµå °øÀ¯¸¦ Áö¿øÇϹǷΠ¸®´ø´ø½ÃÇü µðÀÚÀο¡ ³»ÀåµÈ Ãß°¡ ¿ë·®À» È¿À²ÀûÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. UplinkFast, PortFast ¹× BackboneFast ¸ðµÎ Ç¥ÁØ 30~60ÃÊÀÇ ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ º¯È¯ ½Ã°£À» Å©°Ô ÁÙ¿©ÁÝ´Ï´Ù. BPDU(·çÇÁ°¡µå ¹× ºê¸®Áö ÇÁ·ÎÅäÄÝ µ¥ÀÌÅÍ ÀåÄ¡)´Â Çâ»óµÈ ¹öÀüÀ» ÅëÇØ ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ ·çÇÁ ¹æÁö ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â ³×Æ®¿öÅ© Æ®·¡ÇÈÀ» ºÐ·ùÇϰí, ¿ì¼±¼øÀ§¸¦ ÁöÁ¤ÇÏ¿© ³×Æ®¿öÅ©°¡ Á¤Ã¼µÇ´Â °ÍÀ» °¡Àå È¿°úÀûÀ¸·Î ¹æÁöÇÒ ¼ö ÀÖ´Â QoS ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. QoS ±¸ÇöÀ» À§ÇØ Cisco Catalyst 2960 ½Ã¸®Áî ½ºÀ§Ä¡´Â Æ®·¡ÇÈ È帧 ¶Ç´Â ÆÐŶ ±×·ìÀ» ¸ÕÀú ½Äº°ÇÑ ´ÙÀ½, ÀÌµé ±×·ìÀ» 802.1p CoS(class of service) Çʵ带 »ç¿ëÇÏ¿© ºÐ·ù ¶Ç´Â ÀçºÐ·ùÇÕ´Ï´Ù. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â Æ÷Æ®´ç 4°³ÀÇ ¹æÃâ(egress) ´ë±â¿­À» Áö¿øÇÕ´Ï´Ù. ÀÌ´Â ·£»óÀÇ ´Ù¾çÇÑ ¾ÖÇø®ÄÉÀ̼ǿ¡ ´ëÇÑ ¼Ó¼ºÀ» ÁöÁ¤ÇÒ ¶§ ³×Æ®¿öÅ© °ü¸®ÀÚ°¡ ´õ ¸¹Àº Á¦¾î ±ÇÇÑÀ» °®µµ·Ï ÇÕ´Ï´Ù. ¹æÃâ(egress)¿¡¼­ ½ºÀ§Ä¡´Â Á¤Ã¼ Á¦¾î¿Í ´ë±â¿­¿¡¼­ 󸮵Ǵ ¼ø¼­¸¦ °áÁ¤ÇÏ´Â ¾Ë°í¸®Áò ¶Ç´Â ÇÁ·Î¼¼½º¿¡ ´ëÇÑ ½ºÄÉÁÙ¸µÀ» ¼öÇàÇÕ´Ï´Ù. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡´Â SRR(Shaped Round Robin)°ú ¾ö°ÝÇÑ ¿ì¼±¼øÀ§ ´ë±â¿­ 󸮸¦ Áö¿øÇÕ´Ï´Ù. SRR ¾Ë°í¸®ÁòÀº Â÷º°ÀûÀÎ ¿ì¼±¼øÀ§ ÁöÁ¤À» Á¦°øÇÕ´Ï´Ù.
»õ·Î¿î Express Setup ±â´ÉÀº ½ºÀ§Ä¡ÀÇ Ãʱ⠱¸¼ºÀ» °£¼ÒÈ­ÇÕ´Ï´Ù. ÀÌÁ¦ À¥ ºê¶ó¿ìÀú¸¦ ÅëÇØ ½ºÀ§Ä¡¸¦ ¼³Á¤ÇÒ ¼ö ÀÖÀ¸¹Ç·Î, Å͹̳Π¿¡¹Ä·¹ÀÌ¼Ç ÇÁ·Î±×·¥À̳ª CLI(Command-Line Interface)°¡ ÇÊ¿ä ¾ø°Ô µÇ¾ú½À´Ï´Ù. Express SetupÀº Ãʺ¸Àڵ鵵 ½±°í ºü¸£°Ô ½ºÀ§Ä¡¸¦ ¼³Á¤ÇÒ ¼ö ÀÖµµ·Ï Áö¿øÇÏ¿© ¹èÄ¡ ºñ¿ëÀ» Àý°¨ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Cisco Network Assistant´Â LAN¿¡ ÃÖÀûÈ­µÈ PC ±â¹ÝÀÇ ³×Æ®¿öÅ© °ü¸® ¾ÖÇø®ÄÉÀ̼ÇÀ¸·Î ÃÖ´ë 250¸íÀÇ »ç¿ëÀÚ¸¦ ¼ö¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Cisco Network Assistant´Â ½Ã½ºÄÚ ½ºÀ§Ä¡, ¶ó¿ìÅÍ ¹× ¹«¼± LAN ¾×¼¼½º Æ÷ÀÎÆ®¿¡ Áß¾Ó ÁýÁᫎ °ü¸®¸¦ Á¦°øÇÕ´Ï´Ù. ÀÌ ¾ÖÇø®ÄÉÀ̼ÇÀº Cisco Catalyst 2960ºÎÅÍ Cisco Catalyst 4506 ½ºÀ§Ä¡¿¡ À̸£´Â ±¤¹üÀ§ÇÑ Cisco Catalyst Áö´ÉÇü ½ºÀ§Ä¡¸¦ Áö¿øÇÕ´Ï´Ù. »ç¿ëÀÚ¿¡°Ô Ä£¼÷ÇÑ GUI¸¦ ÅëÇØ »ç¿ëÀÚµéÀº ´Ù¾çÇÑ À¯ÇüÀÇ ½ºÀ§Ä¡ ±â´ÉÀ» ±¸¼ºÇÏ°í °ü¸®ÇÒ ¼ö ÀÖÀ¸¸ç, ½Ã½ºÄÚ ¶ó¿ìÅÍ ¹× ½Ã½ºÄÚ ¹«¼± ¾×¼¼½º Æ÷ÀÎÆ®ÀÇ ÀåÄ¡ ¸Å´ÏÀú¸¦ ½ÃÀÛÇÒ ¼ö ÀÖ½À´Ï´Ù. »ó¼¼ÇÑ ¼³°è °¡À̵尡 ¾ø¾îµµ ¸î ¹øÀÇ ¸¶¿ì½º Ŭ¸¯¸¸À¸·Î ½Ã½ºÄÚ¿¡¼­ ±ÇÀåÇÏ´Â º¸¾È, °¡¿ë¼º ¹× QoS ±â´ÉÀ» ¼öÇàÇÒ ¼ö ÀÖ½À´Ï´Ù. Security(º¸¾È) ¸¶¹ý»ç´Â ±â¹ÐÀ» ¿äÇÏ´Â µ¥ÀÌÅͰ¡ ÀÖ´Â ¼­¹ö¿¡ ´ëÇØ¼­´Â ¹«´Ü ¾×¼¼½º¸¦ ÀÚµ¿À¸·Î Á¦ÇÑÇÕ´Ï´Ù. Smartport ¹× ¸¶¹ý»ç´Â ³×Æ®¿öÅ© °ü¸®ÀÚÀÇ ½Ã°£À» Àý¾àÇØÁÖ¸ç »ç¶÷¿¡ ÀÇÇÑ ½Ç¼ö¸¦ ÁÙ¿©ÁÖ°í, ½ºÀ§Ä¡ÀÇ ±¸¼ºÀÌ ÀÌµé ¾ÖÇø®ÄÉÀ̼ǿ¡ ÃÖÀûÈ­µÇµµ·Ï º¸ÀåÇÕ´Ï´Ù. Cisco Network Assistant´Â ½Ã½ºÄÚ À¥ »çÀÌÆ®¿¡¼­ ¹«·á·Î ´Ù¿î·ÎµåÇÒ ¼ö ÀÖ½À´Ï´Ù.
Cisco Network Assistant À̿ܿ¡µµ CiscoWorks LMS(LAN Management Solution)¿Í °°Àº SNMP ³×Æ®¿öÅ© °ü¸® Ç÷§ÆûÀ» »ç¿ëÇÏ´Â Æ÷°ýÀûÀÎ °ü¸®¸¦ À§ÇÏ¿© Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡°¡ Á¦°øµË´Ï´Ù. LMS´Â ½Ã½ºÄÚ ³×Æ®¿öÅ©ÀÇ ±¸¼º, °ü¸®, ¸ð´ÏÅ͸µ ¹× ¹®Á¦ ÇØ°áÀ» °£¼ÒÈ­ ÇØÁÖ´Â °­·ÂÇÑ °ü¸® µµ±¸ÀÔ´Ï´Ù. ¶ÇÇÑ CiscoWorks LMS´Â ÀÌ·¯ÇÑ ¼º´ÉÀ» ÅëÇÕÇÏ¿© ³×Æ®¿öÅ©ÀÇ Àü¹ÝÀûÀÎ °¡¿ë¼ºÀ» ³ôÀ̸鼭, ÀÛ¾÷ÀÚÀÇ Á¤È®¼º°ú È¿À²¼ºµµ ³ô¿©ÁÖ´Â ¼¼°èÀûÀÎ ¼öÁØÀÇ ¼Ö·ç¼ÇÀ» Á¦°øÇÕ´Ï´Ù. LMSÀº 400°³ ÀÌ»óÀÇ ¼­·Î ´Ù¸¥ ÀåÄ¡ À¯ÇüÀ» Áö¿øÇÕ´Ï´Ù.
  •  »õ·Î¿î ³×Æ®¿öÅ© ¹ß°ß, ÅäÆú·ÎÁö ºä, ÃÖÁ¾ ½ºÅ×ÀÌ¼Ç ÃßÀû ¹× VLAN °ü¸®
  •  ¹èÆ÷°¡ ½¬¿î ÀåÄ¡º° ÃÖÀû ¹æ¾È¿¡ ±â¹ÝÇÑ ÅÛÇø´À» ÅëÇØ ½Ç½Ã°£ ³×Æ®¿öÅ© °áÇÔ ºÐ¼®
  •  Çϵå¿þ¾î ¹× ¼ÒÇÁÆ®¿þ¾î Àκ¥Å丮 °ü¸®, Áß¾Ó ÁýÁßÈ­µÈ ±¸¼º µµ±¸ ¹× Syslog ¸ð´ÏÅ͸µ
  •  ³×Æ®¿öÅ© ÀÀ´ä ½Ã°£ ¹× °¡¿ë¼º ¸ð´ÏÅ͸µ ¹× ÃßÀû
  •  ½Ç½Ã°£ ÀåÄ¡, ¸µÅ© ¹× Æ÷Æ® Æ®·¡ÇÈ¿¡ ´ëÇÑ °ü¸®, ºÐ¼® ¹× º¸°í
Ç¥ 1Àº Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ ±â´É°ú ÀÌÁ¡À» ³ªÅ¸³À´Ï´Ù. Ç¥ 2´Â Çϵå¿þ¾î »ç¾çÀ» ³ªÅ¸³»¸ç, Ç¥ 3Àº Àü¿ø »ç¾çÀ» ³ªÅ¸³À´Ï´Ù. Ç¥ 4´Â °ü¸® ¹× Ç¥ÁØ Áö¿ø¿¡ ´ëÇØ ¼³¸íÇϸç, Ç¥ 5´Â ¾ÈÀü ¹× Áؼö Á¤º¸¸¦ Á¦°øÇÕ´Ï´Ù.
Ç¥ 1. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ ±â´É°ú ÀÌÁ¡
±â´É ÀÌÁ¡
»ç¿ë ¹× ¹èÄ¡ÀÇ °£ÆíÇÔ
  •  Express SetupÀº À¥ ºê¶ó¿ìÀú¸¦ ÅëÇØ Ãʱâ ȯ°æ¼³Á¤À» °£¼ÒÈ­ÇϹǷΠº¹ÀâÇÑ Å͹̳Π¿¡¹Ä·¹ÀÌ¼Ç ÇÁ·Î±×·¥À̳ª CLI Áö½ÄÀÌ ÇÊ¿ä ¾ø½À´Ï´Ù.
  •  ½ºÀ§Ä¡ ¹èÄ¡¸¦ ¿ëÀÌÇÏ°Ô ÇÏ´Â ºÎÆ® ¼­¹ö(boot server)¸¦ ÅëÇØ ´ÙÁß ½ºÀ§Ä¡¸¦ DHCP ÀÚµ¿ ±¸¼ºÇÕ´Ï´Ù.
  •  °¢ 10/100 Æ÷Æ®»ó¿¡¼­ÀÇ ÀÚµ¿ °¨Áö ±â´ÉÀº ¿¬°áµÈ ÀåÄ¡ÀÇ ¼Óµµ¸¦ °¨ÁöÇÏ¿© 10 ¶Ç´Â 100Mbps ÀÛ¾÷À» À§ÇÑ Æ÷Æ®¸¦ ÀÚµ¿À¸·Î ±¸¼ºÇϸç, ÀÌ·¯ÇÑ 10 ¶Ç´Â 100Mbps º¹ÇÕ È¯°æ¿¡¼­ ½ºÀ§Ä¡ ¹èÄ¡¸¦ ¿ëÀÌÇÏ°Ô ÇÕ´Ï´Ù.
  •  ¸ðµç Æ÷Æ®»ó¿¡¼­ÀÇ ÀÚµ¿ Çù»ó ±â´ÉÀº ÀÚµ¿À¸·Î ¹ÝÀÌÁß(half-duplex) ¶Ç´Â ÀüÀÌÁß(full-duplex) Àü¼Û ¸ðµå¸¦ ¼±ÅÃÇÏ¿© ´ë¿ªÆøÀ» ÃÖÀûÈ­ÇÕ´Ï´Ù.
  •  DTP(Dynamic Trunking Protocol)´Â ¸ðµç ½ºÀ§Ä¡ Æ÷Æ®¿¡ ´ëÇØ µ¿ÀûÀÎ Æ®··Å© ±¸¼ºÀ» Áö¿øÇÕ´Ï´Ù.
  •  PAgP(Port Aggregation Protocol)´Â Cisco Fast EtherChannel¢ç ±×·ì ¶Ç´Â Gigabit EtherChannel ±×·ì »ý¼ºÀ» ÀÚµ¿È­ÇÏ¿© ´Ù¸¥ ½ºÀ§Ä¡, ¶ó¿ìÅÍ ¶Ç´Â ¼­¹ö·Î ¿¬°áÇÕ´Ï´Ù.
  •  LACP(Link Aggregation Control Protocol)´Â IEEE 802.3ad¸¦ ÁؼöÇÏ´Â ÀåÄ¡¿ÍÀÇ ÀÌ´õ³Ý ä³Î¸µ »ý¼ºÀ» Áö¿øÇÕ´Ï´Ù. ÀÌ ±â´ÉÀº Cisco EtherChannel ±â¼ú ¹× PagP¿Í À¯»çÇÕ´Ï´Ù.
  •  DHCP ¼­¹ö´Â Àü¿ë DHCP ¼­¹ö°¡ ¾ø´Â ³×Æ®¿öÅ©¿¡¼­ IP ÁÖ¼Ò ÇÒ´çÀ» À§ÇØ Æí¸®ÇÑ ¹èÄ¡ ¿É¼ÇÀ» Áö¿øÇÕ´Ï´Ù.
  •  DHCP Relay´Â DHCP ¸±·¹ÀÌ ¿¡ÀÌÀüÆ®°¡ DHCP ¿äûÀ» ³×Æ®¿öÅ© DHCP ¼­¹ö¿¡ Àü´ÞÇÒ ¼ö ÀÖµµ·Ï Áö¿øÇÕ´Ï´Ù.
  •  ±³Ã¼ °¡´ÉÇÑ SFP ¸ðµâÀ» ÅëÇÑ 1000BASE-SX, 1000BASE-LX/LH ¹× 100BASE-FX ¹°¸®Àû ÀÎÅÍÆäÀ̽º Áö¿øÀº ½ºÀ§Ä¡ ¹èÄ¡¿¡ À־ À¯¿¬¼ºÀ» Á¦°øÇÕ´Ï´Ù.
  •  Ç÷¡½Ã ¸Þ¸ð¸®¿¡ ÀúÀåµÇ¾î ÀÖ´Â ±âº» ±¸¼ºÀº ½ºÀ§Ä¡°¡ ÇØ´ç ³×Æ®¿öÅ©¿¡ ½Å¼ÓÇÏ°Ô ¿¬°áµÇ°í »ç¿ëÀÚ °£¼·À» ÃÖ¼ÒÈ­ÇÏ¿© Æ®·¡ÇÈÀ» Àü´ÞÇÒ ¼ö ÀÖµµ·Ï º¸ÀåÇÕ´Ï´Ù.
  •  Auto-MDIX(Automatic medium-dependent interface crossover)´Â ÄÚÆÛ(copper) Æ÷Æ®¿¡ ¿Ã¹Ù¸£Áö ¾ÊÀº ÄÉÀ̺í À¯Çü(Å©·Î½º¿À¹ö ¶Ç´Â Ç¥ÁØÇü(straight-through))ÀÌ ¼³Ä¡µÇ¾î ÀÖÀ» °æ¿ì ÀÚµ¿À¸·Î Àü¼Û ¹× ¼ö½Å ½ÖÀ» Á¶ÀýÇÕ´Ï´Ù.
  •  TDR(Time-domain reflectometer)Àº ÄÚÆÛ Æ÷Æ®¿¡¼­ÀÇ ÄÉÀÌºí ¹®Á¦¸¦ Áø´ÜÇϰí ÇØ°áÇÕ´Ï´Ù.
  •  ·Ñ¹é ±¸¼ºÀº ÇöÀç ½ÇÇà ÁßÀÎ ±¸¼ºÀ» ÀúÀåµÈ Cisco IOS Software ±¸¼º ÆÄÀÏ·Î ¹Ù²Ù´Â ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ ±â´ÉÀº ±¸¼º ÆÄÀÏÀÌ ÀúÀåµÈ ÀÌÈÄ¿¡ º¯°æµÈ ±¸¼º ÆÄÀÏÀ» È¿°úÀûÀ¸·Î ·Ñ¹éÇϱâ À§ÇØ ÀÌÀü ±¸¼º »óÅ·ΠµÇµ¹¸®´Â µ¥ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. (ÇâÈÄ ¼­ºñ½º Á¦°ø ¿¹Á¤)
  •  DHCP ÀÚµ¿ ¼³Ä¡(ºÎ½ºÆ® È£½ºÆ® DHCP) ¹× ÀÚµ¿ À̹ÌÁö ¾÷µ¥ÀÌÆ®¸¦ »ç¿ëÇÏ¸é ½ºÀ§Ä¡°¡ ±¸¼º ÆÄÀϰú Cisco IOS Software¸¦ ÀÚµ¿À¸·Î ´Ù¿î·ÎµåÇÒ ¼ö ÀÖ½À´Ï´Ù. (ÇâÈÄ ¼­ºñ½º Á¦°ø ¿¹Á¤)
°ü¸® ±â´É
Ź¿ùÇÑ °ü¸® ±â´É
  •  Cisco IOS Software CLI Áö¿øÀº ¸ðµç ½Ã½ºÄÚ ¶ó¿ìÅÍ ¹× Cisco Catalyst µ¥½ºÅ©Åé ½ºÀ§Ä¡¿Í ÇÔ²² ÀϹÝÀûÀÎ »ç¿ëÀÚ ÀÎÅÍÆäÀ̽º ¹× ¸í·É ¼¼Æ®¸¦ Á¦°øÇÕ´Ï´Ù.
  •  Ç¥ÁØ ±â¹ÝÀÇ 802.1q űëÀ» »ç¿ëÇÏ¿© ¸ðµç Æ÷Æ®¿¡¼­ VLAN Æ®··Å©¸¦ »ý¼ºÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  ½ºÀ§Ä¡´ç ÃÖ´ë 64°³ÀÇ VLAN°ú ½ºÀ§Ä¡´ç ÃÖ´ë 64°³ÀÇ ½ºÆÐ´× Æ®¸® ÀνºÅϽº°¡ Áö¿øµË´Ï´Ù.
  •  4,000°³ÀÇ VLAN ID°¡ Áö¿øµË´Ï´Ù.
  •  À½¼º VLANÀº º¸´Ù ½¬¿î °ü¸®¿Í ¹®Á¦ ÇØ°áÀ» À§ÇØ À½¼º Æ®·¡ÇÈÀ» °³º° VLAN¿¡ º¸Á¸ÇÏ¿© ÅÚ·¹Æ÷´Ï ¼³Ä¡¸¦ °£¼ÒÈ­ÇÕ´Ï´Ù.
  •  ½Ã½ºÄÚ VTP´Â ¸ðµç ½ºÀ§Ä¡¿¡ ´ëÇÑ µ¿ÀûÀÎ VLAN ¹× µ¿ÀûÀÎ Æ®··Å© ±¸¼ºÀ» Áö¿øÇÕ´Ï´Ù.
  •  IGMPv3 ½º´©ÇÎÀº ½Å¼ÓÇÑ Å¬¶óÀÌ¾ðÆ® Á¢¼Ó°ú ¸ÖƼij½ºÆ® ½ºÆ®¸²À» Á¦°øÇϸç, ´ë¿ªÆø ÁýÁß ºñµð¿À Æ®·¡ÇÈÀ» ¿äûÀÚ¿¡°Ô·Î¸¸ Á¦ÇÑÇÕ´Ï´Ù.
  •  °í±Þ Æ®·¡ÇÈ °ü¸®, ¸ð´ÏÅ͸µ ¹× ºÐ¼®À» À§ÇØ, ³»ÀåµÈ RMON(¿ø°Ý ¸ð´ÏÅ͸µ) ¼ÒÇÁÆ®¿þ¾î ¿¡ÀÌÀüÆ®°¡ 4°³ÀÇ RMON ±×·ì(ÀÌ·Â, Åë°è, °æº¸ ¹× À̺¥Æ®)À» Áö¿øÇÕ´Ï´Ù.
  •  Layer 2 ÃßÀû ·çÆ®´Â ÆÐŶÀÌ ¼Ò½º·ÎºÎÅÍ ¸ñÀûÁö·Î °¡Á®¿À´Â ¹°¸®ÀûÀÎ °æ·Î¸¦ ½Äº°ÇÏ¿© ¹®Á¦ ÇØ°áÀ» ¿ëÀÌÇÏ°Ô ÇÕ´Ï´Ù.
  •  ¸ðµç RMON ±×·ìÀÌ SPAN Æ÷Æ®¸¦ ÅëÇØ Çã¿ëµÇ¸ç, À̷νá ÇϳªÀÇ ³×Æ®¿öÅ© ºÐ¼®±â ¶Ç´Â RMON Á¶»ç·ÎºÎÅÍ ´ÜÀÏ Æ÷Æ® ¶Ç´Â Æ÷Æ® ±×·ìÀÇ Æ®·¡ÇÈÀ» ¸ð´ÏÅÍÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  DNS(Domain Name System)´Â »ç¿ëÀÚ°¡ ÁöÁ¤ÇÑ ÀåÄ¡ À̸§À» »ç¿ëÇÑ IP ÁÖ¼Ò ÁöÁ¤À» Áö¿øÇÕ´Ï´Ù.
  •  TFTP(Trivial File Transfer Protocol)´Â Áß¾Ó¿¡¼­ ´Ù¿î·Îµå ÇÔÀ¸·Î½á ¼ÒÇÁÆ®¿þ¾îÀÇ ¾÷±×·¹ÀÌµå °ü¸® ºñ¿ëÀ» Àý°¨ÇØ ÁÝ´Ï´Ù.
  •  NTP(Network Timing Protocol)´Â ¸ðµç ÀÎÆ®¶ó³Ý ½ºÀ§Ä¡¿¡ ´ëÇØ Á¤È®Çϰí ÀϰüÀûÀΠŸÀÓ½ºÅÆÇÁ¸¦ Á¦°øÇÕ´Ï´Ù.
  •  Æ÷Æ® »óŸ¦ ³ªÅ¸³»´Â Æ÷Æ®º° ´ÙÁß ±â´É LED, ¹ÝÀÌÁß ¹× ÀüÀÌÁß ¸ðµå, ±×¸®°í 10BASE-T, 100BASE-TX ¹× 1000BASE-T Ç¥½Ã, ½Ã½ºÅÛÀ» À§ÇÑ ½ºÀ§Ä¡ ¼öÁØÀÇ »óÅ LED, ¸®´ø´ø½Ã Àü¿ø °ø±Þ ÀåÄ¡¸¦ ÅëÇØ Æ÷°ýÀûÀÌ°í Æí¸®ÇÑ °ü¸® ½Ã½ºÅÛÀ» Á¦°øÇÕ´Ï´Ù.
  •  Cisco Discovery Protocol Versions 1 ¹× 2´Â ³×Æ®¿öÅ© °ü¸® µµ±¸¸¦ À§ÇÑ ÀÚµ¿ ½ºÀ§Ä¡ °¨Áö¸¦ ÅëÇØ Cisco IP ÀüÈ­·Î À½¼º VLAN Á¤º¸¸¦ Åë½ÅÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  LLDP(Link Layer Discovery Protocol)´Â ¿©·¯ °ø±Þ¾÷üÀÇ ³×Æ®¿öÅ©¿¡¼­ ¸µÅ© ¹× ÀåÄ¡ Á¤º¸¸¦ ±³È¯ÇÕ´Ï´Ù.
Cisco Network Assistant
  •  Cisco Network Assistant´Â Windows ±â¹ÝÀÇ ¹«·á ¾ÖÇø®ÄÉÀ̼ÇÀ¸·Î ÃÖ´ë 250¸íÀÇ »ç¿ëÀÚ¿¡ ´ëÇÑ ³×Æ®¿öÅ© °ü¸®¸¦ °£¼ÒÈ­ÇÕ´Ï´Ù. ÀÌ Á¦Ç°Àº ±¤¹üÀ§ÇÑ Cisco Catalyst Áö´ÉÇü ½ºÀ§Ä¡¸¦ Áö¿øÇÕ´Ï´Ù. Cisco Network Assistant¸¦ ÅëÇØ »ç¿ëÀÚµéÀº Cisco Catalyst ½ºÀ§Ä¡¸¦ °ü¸®Çϰí, ½Ã½ºÄÚ ÅëÇÕ ¼­ºñ½º ¶ó¿ìÅÍ ¹× Cisco Aironet¢ç WLAN ¾×¼¼½º Æ÷ÀÎÆ®ÀÇ ÀåÄ¡ ¸Å´ÏÀú¸¦ ½ÇÇàÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  »ç¿ëÀÌ ½¬¿î ±×·¡ÇÈ ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ Ŭ·¯½ºÅÍ ¹× ½ºÅÃ(stack)¿¡ ´ëÇÑ ÅäÆú·ÎÁö ¸Ê°ú Àü¸é ºä(front-panel view)¸¦ Á¦°øÇÕ´Ï´Ù.
  •  ±¸¼º ¸¶¹ý»ç(Configuration Wizards)¸¦ ÅëÇØ ¾à°£ÀÇ »ç¿ëÀÚ ÀԷ¸¸À¸·Î À½¼º, ºñµð¿À, ¸ÖƼij½ºÅ© ¹× ¿ì¼±¼øÀ§°¡ ³ôÀº µ¥ÀÌÅÍ¿Í °°Àº ¼­·Î ´Ù¸¥ À¯ÇüÀÇ Æ®·¡ÇÈ Ã³¸®¸¦ ÃÖÀûÈ­Çϵµ·Ï ½ºÀ§Ä¡¸¦ ÀÚµ¿À¸·Î ±¸¼ºÇÕ´Ï´Ù.
  •  º¸¾È ¸¶¹ý»ç(Security Wizards)´Â ¾ÖÇø®ÄÉÀ̼Ç, ¼­¹ö ¹× ³×Æ®¿öÅ©¿¡ ´ëÇÑ ¹«´Ü ¾×¼¼½º¸¦ Á¦ÇÑÇϱâ À§ÇØ Á¦°øµË´Ï´Ù.
  •  ¸¶¿ì½º·Î °¡¸®Å°°í Ŭ¸¯¸¸ Çϸé Cisco Catalyst ½ºÀ§Ä¡¿¡ ´ëÇÑ Cisco IOS ¼ÒÇÁÆ®¿þ¾î¸¦ ¾÷±×·¹À̵åÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  ´ÙÁß Àåºñ ¹× ´ÙÁß Æ÷Æ® ±¸¼ºÀ» ÅëÇØ ¿©·¯ ½ºÀ§Ä¡ ¹× Æ÷Æ®¿¡ ´ëÇÑ ±â´ÉÀ» µ¿½Ã¿¡ ±¸¼ºÇÒ ¼ö ÀÖÀ¸¹Ç·Î °ü¸®ÀÚÀÇ ½Ã°£ÀÌ Àý¾àµË´Ï´Ù.
  •  »ç¿ëÀÚº°·Î ¸ÂÃãÈ­µÈ ÀÎÅÍÆäÀ̽º¸¦ ÅëÇØ Æú¸µ(polling) °£°Ý, Å×ÀÌºí ºä ¹× ±âŸ ¼³Á¤À» ¼Õ½±°Ô ¼öÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  ¾Ë¶÷ Å뺸 ±â´ÉÀº ³×Æ®¿öÅ© ¿À·ù³ª ¾Ë¶÷ ÀÓ°è°ª¿¡ ´ëÇÏ¿© ÀÚµ¿È­µÈ À̸ÞÀÏ Å뺸¸¦ Á¦°øÇÕ´Ï´Ù.
Cisco Express Setup
  •  Express SetupÀº À¥ ºê¶ó¿ìÀú¸¦ ÅëÇØ Ãʱ⠽ºÀ§Ä¡ ±¸¼ºÀ» °£¼ÒÈ­ÇÏ¿©, Å͹̳Π¿¡¹Ä·¹ÀÌ¼Ç ÇÁ·Î±×·¥ ¹× CLI Áö½ÄÀÌ ÇÊ¿ä ¾ø½À´Ï´Ù.
  •  Express SetupÀº Ãʺ¸Àڵ鵵 ½±°í ºü¸£°Ô ½ºÀ§Ä¡¸¦ ¼³Á¤ÇÒ ¼ö ÀÖµµ·Ï Áö¿øÇÏ¿© ¹èÄ¡ ºñ¿ëÀ» Àý°¨ÇÕ´Ï´Ù.
CiscoWorks Áö¿ø
  •  Æ÷Æ®º° ¹× ½ºÀ§Ä¡º°·Î CiscoWorks ³×Æ®¿öÅ© °ü¸® ¼ÒÇÁÆ®¿þ¾î¸¦ ÅëÇØ °ü¸® ±â´ÉÀ» Á¦°øÇϸç, ½Ã½ºÄÚ ¶ó¿ìÅÍ, ½ºÀ§Ä¡ ¹× Çãºê¸¦ À§ÇÑ °øÅë °ü¸® ÀÎÅÍÆäÀ̽º¸¦ Á¦°øÇÕ´Ï´Ù.
  •  SNMP v1, v2c ¹× v3 ±×¸®°í ÅÚ³Ý ÀÎÅÍÆäÀ̽º´Â Æ÷°ýÀûÀÎ ´ë¿ª ³»(in-band) °ü¸®¸¦ Á¦°øÇϸç, CLI ±â¹Ý °ü¸® ÄܼÖÀº »ó¼¼ÇÑ ´ë¿ª ¿Ü(out-of-band) °ü¸®¸¦ Á¦°øÇÕ´Ï´Ù.
  •  Cisco Discovery Protocol Versions 1 ¹× 2´Â ÀÚµ¿ ½ºÀ§Ä¡ °Ë»öÀ» À§ÇÑ CiscoWorks ³×Æ®¿öÅ© °ü¸® ½ºÅ×À̼ÇÀ» Áö¿øÇÕ´Ï´Ù.
  •  CiscoWorks LAN Management SolutionÀº Cisco Catalyst 2960 ½Ã¸®Á Áö¿øÇÕ´Ï´Ù.
°¡¿ë¼º ¹× È®À强
Àå¾Ö ¹é¾÷À» À§ÇÑ ÃÖ»óÀÇ ¸®´ø´ø½Ã
  •  Cisco UplinkFast ¹× BackboneFast ±â¼úÀº ½Å¼ÓÇÑ Àå¾Ö º¹±¸ ±â´ÉÀ» º¸ÀåÇÏ¿© ÀüüÀûÀÎ ³×Æ®¿öÅ© ¾ÈÁ¤¼º°ú ½Å·Ú¼ºÀ» °­È­ÇÕ´Ï´Ù.
  •  IEEE 802.1w Rapid ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ(STP)Àº ½ºÆÐ´× Æ®¸® ŸÀÌ¸Ó¿Í ºÐ»ê ÇÁ·Î¼¼½ÌÀÇ ÀÌÁ¡¿¡ »ó°ü¾øÀÌ ½Å¼ÓÇÑ ½ºÆÐ´× Æ®¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù.
  •  PVRST+(Per-VLAN Rapid Spanning Tree Plus)´Â ½ºÆÐ´× Æ®¸® ÀνºÅϽº¸¦ ±¸ÇöÇÒ ÇÊ¿ä ¾øÀÌ per-VLAN ½ºÆÐ´× Æ®¸® ±â¹ÝÀ¸·Î ½Å¼ÓÇÑ ½ºÆÐ´× Æ®¸® ¸®ÄÁ¹öÀü½º¸¦ Áö¿øÇÕ´Ï´Ù.
  •  Cisco Network Assistant ¼ÒÇÁÆ®¿þ¾î¿¡ Áö¿øµÇ´Â ¸í·É ½ºÀ§Ä¡ ¸®´ø´ø½Ã´Â ±âº» ¸í·É ½ºÀ§Ä¡¿¡ Àå¾Ö°¡ ¹ß»ýÇÒ °æ¿ì ÀÛ¾÷À» ´ë½ÅÇÒ ¹é¾÷ ¸í·É ½ºÀ§Ä¡¸¦ ÁöÁ¤ÇÕ´Ï´Ù.
  •  UDLD(Unidirectional Link Detection Protocol) ¹× Aggressive UDLD¸¦ »ç¿ëÇÏ¿© ´Ü¹æÇâ ¸µÅ©¸¦ °¨ÁöÇÑ ÈÄ ºñȰ¼ºÈ­ÇÏ¿© ½ºÆÐ´× Æ®¸® ·çÇÁ¿Í °°Àº ¹®Á¦¸¦ ¹æÁöÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  ½ºÀ§Ä¡ Æ÷Æ® ÀÚµ¿ º¹±¸(errdisable) ±â´ÉÀº ³×Æ®¿öÅ© ¿À·ù·Î ÀÎÇØ ºñȰ¼ºÈ­µÈ ¸µÅ©¸¦ ÀÚµ¿À¸·Î ÀçȰ¼ºÈ­µÇµµ·Ï ½ÃµµÇÕ´Ï´Ù.
  •  Cisco Gigabit EtherChannel ±â¼úÀ» ÅëÇØ 8Gbps±îÁö, Cisco Fast EtherChannel ±â¼úÀ» ÅëÇØ 800Mbps±îÁö ´ë¿ªÆøÀ» ÅëÇÕÇϸé Àå¾Ö ±Øº¹·üÀ» ³ôÀÌ°í ½ºÀ§Ä¡, ¶ó¿ìÅÍ ¹× °³º° ¼­¹ö °£ÀÇ ´ë¿ªÆøÀ» ºü¸£°Ô ÅëÇÕÇÒ ¼ö ÀÖ½À´Ï´Ù.
´ë¿ªÆø ÃÖÀûÈ­¸¦ À§ÇÑ ÅëÇÕ Cisco IOS® ¼ÒÇÁÆ®¿þ¾î ±â´É
  •  Æ÷Æ®´ç ºê·Îµåij½ºÆ®, ¸ÖƼij½ºÆ® ¹× À¯´Ïij½ºÆ® ½ºÅè Á¦¾î ±â´ÉÀ» ÅëÇØ Àå¾Ö°¡ ÀÖ´Â ¿£µå ½ºÅ×À̼ÇÀÌ ÀüüÀûÀÎ ½Ã½ºÅÛ ¼º´ÉÀ» ÀúÇϽÃŰ´Â °ÍÀ» ¹æÁöÇÕ´Ï´Ù.
  •  ¸®´ø´ø½ÃÇü ¹éº»(backcone) ¿¬°á ¹× ·çÇÁ ¾ø´Â ³×Æ®¿öÅ©¸¦ À§ÇÑ IEEE 802.1d ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ(STP)ÀÌ Áö¿øµÇ¾î ³×Æ®¿öÅ© ±¸¼ºÀ» °£¼ÒÈ­Çϰí Àå¾Ö ±Øº¹·üÀ» ³ôÀÔ´Ï´Ù.
  •  IEEE 802.1s Multiple ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ(STP)ÀÌ VLAN´ç ½ºÆÐ´× Æ®¸® ÀνºÅϽº¸¦ Áö¿øÇÏ¿©, ¸®´ø´ø½ÃÇü ¸µÅ©»ó¿¡¼­ Layer 2 ·Îµå °øÀ¯¸¦ °¡´ÉÇÏ°Ô ÇÕ´Ï´Ù.
  •  Local Proxy ARP(Address Resolution Protocol)°¡ Private VLAN Edge¿Í ÇÔ²² µ¿ÀÛÇÏ¿© ºê·Îµåij½ºÆ®´Â ÃÖ¼ÒÈ­ÇÏ°í »ç¿ë °¡´ÉÇÑ ´ë¿ªÆøÀº ÃÖ´ëÈ­ÇÕ´Ï´Ù.
  •  VLAN1 ÃÖ¼ÒÈ­ ±â´ÉÀ» ÅëÇØ °³º° VLAN Æ®··Å© ¸µÅ©¿¡¼­ VLAN1ÀÌ ºñȰ¼ºÈ­µÇµµ·Ï ÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  VTP(VLAN Trunking Protocol) pruningÀº ´ë»ó Àåºñ¿¡ µµ´ÞÇØ¾ß ÇÏ´Â Æ®··Å© ¸µÅ©»ó¿¡¼­¸¸ ºê·Îµåij½ºÆ® Æ®·¡ÇÈÀ» ³ÑÄ¡µµ·Ï ÇÏ¿© VTP Æ®··Å©»óÀÇ ´ë¿ªÆø ¼Òºñ¸¦ Á¦ÇÑÇÕ´Ï´Ù.
  •  IGMP(Internet Group Management Protocol) ¹öÀü 3 ½º´©ÇÎÀº ½Å¼ÓÇÑ Å¬¶óÀÌ¾ðÆ® Á¢¼Ó°ú ¸ÖƼij½ºÆ® ½ºÆ®¸²À» Á¦°øÇϸç, ´ë¿ªÆø ÁýÁß ºñµð¿À Æ®·¡ÇÈÀ» ¿äûÀÚ¿¡°Ô·Î¸¸ Á¦ÇÑÇÕ´Ï´Ù.
  •  IGMP ÇÊÅ͸µÀº ºñµî·ÏÀÚ¸¦ Â÷´ÜÇÏ¿© ¸ÖƼij½ºÆ® ÀÎÁõÀ» Á¦°øÇϸç, Æ÷Æ®´ç »ç¿ë °¡´ÉÇÑ µ¿½Ã ¸ÖƼij½ºÆ® ½ºÆ®¸²ÀÇ °³¼ö¸¦ Á¦ÇÑÇÕ´Ï´Ù.
QoS ¹× Á¦¾î
°í±Þ QoS
  •  Ç¥ÁØ 802.1p CoS ÇÊµå ºÐ·ù°¡ Á¦°øµË´Ï´Ù.
  •  Æ÷Æ®´ç 4°³ÀÇ ¹æÃâ(egress) ´ë±â¿­À» Áö¿øÇÏ¿© ÃÖ´ë 4°³ÀÇ Æ®·¡ÇÈ À¯Çü¿¡ ´ëÇÑ Â÷º°È­µÈ °ü¸®¸¦ °¡´ÉÇÏ°Ô ÇÕ´Ï´Ù.
  •  SRR ½ºÄÉÁÙ¸µÀÌ ¼ö½Å ¹× ¹æÃâ ´ë±â¿­À» Áö´ÉÀûÀ¸·Î ¼­ºñ½ºÇÔÀ¸·Î½á ÆÐŶ È帧ÀÇ Â÷º°È­µÈ ¿ì¼±¼øÀ§¸¦ ¼³Á¤ÇÕ´Ï´Ù.
  •  WTD(Weighted tail drop)°¡ ¹®Á¦°¡ ¹ß»ýÇϱâ Àü¿¡ ¼ö½Å ¹× ¹æÃâ ´ë±â¿­¿¡¼­ÀÇ Á¤Ã¼¸¦ ¹æÁöÇÕ´Ï´Ù.
  •  ¾ö°ÝÇÑ ¿ì¼±¼øÀ§ ´ë±â¿­ ó¸® Á¤Ã¥À» ÅëÇØ °¡Àå ³ôÀº ¿ì¼±¼øÀ§¸¦ °¡Áø ÆÐŶÀÌ ´Ù¸¥ Æ®·¡ÇȺ¸´Ù ¸ÕÀú ¼­ºñ½ºµÇµµ·Ï º¸ÀåÇÕ´Ï´Ù.
º¸¾È
³×Æ®¿öÅ© Àüü º¸¾È ±â´É
  •  IEEE 802.1x°¡ Æ÷Æ® ±â¹ÝÀÇ µ¿Àû º¸¾ÈÀ» Çã¿ëÇÏ¿© »ç¿ëÀÚ ÀÎÁõÀ» Á¦°øÇÕ´Ï´Ù.
  •  VLANÀÌ ÇÒ´çµÈ IEEE 802.1x¸¦ ÅëÇØ »ç¿ëÀÚÀÇ ¿¬°á À§Ä¡¿Í »ó°ü¾øÀÌ Æ¯Á¤ »ç¿ëÀÚ¸¦ À§ÇÑ µ¿Àû VLAN ÇÒ´çÀ» Áö¿øÇÕ´Ï´Ù.
  •  À½¼º VLANÀ» »ç¿ëÇÑ IEEE 802.1x´Â Æ÷Æ®¿¡ ´ëÇÑ Çã¿ë ¿©ºÎ¿Í »ó°ü¾øÀÌ IP ÀüÈ­·Î À½¼º VLAN ¾×¼¼½º°¡ °¡´ÉÇϵµ·Ï Çã¿ëÇÕ´Ï´Ù.
  •  Å¬¶óÀÌ¾ðÆ® ÁÖ¼Ò¸¦ ºñ·ÔÇÑ ¸ðµç MAC ÁÖ¼Ò¿¡ ´ëÇØ Æ÷Æ®¸¦ ÀÎÁõÇÏ°í ³×Æ®¿öÅ© ¾×¼¼½º¸¦ °ü¸®Çϱâ À§ÇØ IEEE 802.1x ¹× Æ÷Æ® º¸¾ÈÀÌ Á¦°øµË´Ï´Ù.
  •  Guest VLANÀÌ ÇÒ´çµÈ IEEE 802.1x°¡ 802.1x Ŭ¶óÀÌ¾ðÆ®°¡ ¾ø´Â °Ô½ºÆ®µéÀÌ °Ô½ºÆ® VLAN¿¡ ´ëÇØ Á¦ÇÑµÈ ³×Æ®¿öÅ© ¾×¼¼½º¸¦ °¡Áöµµ·Ï Áö¿øÇÕ´Ï´Ù.
  •  À½¼º¿ë MAB(MAC Auth Bypass)¸¦ »ç¿ëÇϸé 802.1x ½ÅûÀÚ ¾øÀ̵µ MAC ÁÖ¼Ò¸¦ ÅëÇØ Ÿ»ç IP ÆùÀ» ÀÎÁõÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  À¯´Ïij½ºÆ® MAC ÇÊÅ͸µÀ» »ç¿ëÇϸé MAC ÁÖ¼Ò°¡ ÀÏÄ¡ÇÏ´Â ÆÐŶ À¯ÇüÀÇ Àü´ÞÀ» Â÷´ÜÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  ¾Ë·ÁÁöÁö ¾ÊÀº À¯´Ïij½ºÆ® ¹× ¸ÖƼij½ºÆ® Æ÷Æ® Â÷´Ü ±â´ÉÀÌ ½ºÀ§Ä¡¿¡¼­ ¾ÆÁ÷ Æ÷¿öµù ¹æ¹ýÀ» ¾òÁö ¸øÇÑ ÆÐŶµéÀ» ÇÊÅ͸µÇÔÀ¸·Î½á ¾ö°ÝÇÑ Á¦¾î°¡ ÀÌ·ç¾îÁý´Ï´Ù.
  •  SSHv2 ¹× SNMPv3ÀÌ ÅÚ³Ý ¹× SNMP ¼¼¼Ç Áß¿¡ °ü¸®ÀÚ Æ®·¡ÇÈÀ» ¾ÏȣȭÇÔÀ¸·Î½á ³×Æ®¿öÅ© º¸¾ÈÀ» Á¦°øÇÕ´Ï´Ù. SSHv2 ¹× SNMPv3ÀÇ ¾ÏȣȭµÈ ¹öÀüÀº ¹Ì±¹ÀÇ ¼öÃâ Á¦ÇÑ ¶§¹®¿¡ Ư¼öÇÏ°Ô ¾ÏȣȭµÈ ¼ÒÇÁÆ®¿þ¾î À̹ÌÁö¸¦ ÇÊ¿ä·Î ÇÕ´Ï´Ù.
  •  SPAN(Switched Port Analyzer) Æ÷Æ®»óÀÇ ¾ç¹æÇâ µ¥ÀÌÅÍ Áö¿øÀ» ÅëÇØ ħÀÔÀÚ°¡ °¨ÁöµÇ¾úÀ» ¶§ Cisco Secure IDS(intrusion detection system)°¡ Á¶Ä¡¸¦ ÃëÇÕ´Ï´Ù.
  •  TACACS+ ¹× RADIUS ÀÎÁõÀ» ÅëÇØ ½ºÀ§Ä¡ÀÇ Áß¾Ó ÁýÁᫎ Á¦¾î°¡ Áö¿øµÇ¸ç, ¹«´Ü »ç¿ëÀÚ°¡ ±¸¼ºÀ» º¯°æÇÏ´Â °ÍÀ» Á¦ÇÑÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  MAC ÁÖ¼Ò Å뺸 ±â´ÉÀ» ÅëÇØ ³×Æ®¿öÅ©¿¡ Ãß°¡µÇ°Å³ª »èÁ¦µÈ »ç¿ëÀÚµéÀ» °ü¸®ÀÚ°¡ Å뺸 ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.
  •  Æ÷Æ® º¸¾ÈÀº MAC ÁÖ¼Ò¸¦ ±â¹ÝÀ¸·Î ¾×¼¼½º ¶Ç´Â Æ®··Å© Æ÷Æ®¿¡ ´ëÇÑ ¾×¼¼½º º¸¾ÈÀ» Á¦°øÇÕ´Ï´Ù.
  •  ÁöÁ¤µÈ ½Ã°£ÀÌ °æ°úµÇ¸é ¿¡ÀÌ¡ ±â´ÉÀ» ÅëÇØ ½ºÀ§Ä¡¿¡¼­ ÇØ´ç MAC ÁÖ¼Ò¸¦ »èÁ¦ÇÏ¿© ´Ù¸¥ ÀåÄ¡°¡ µ¿ÀÏÇÑ Æ÷Æ®¿¡ ¿¬°áµÉ ¼ö ÀÖµµ·Ï Çã¿ëÇÕ´Ï´Ù.
  •  ÄÜ¼Ö ¾×¼¼½º»óÀÇ ´ÙÁß ¼öÁØ º¸¾È ±â´ÉÀ» ÅëÇØ Çã°¡ ¹ÞÁö ¾ÊÀº »ç¿ëÀÚ°¡ ½ºÀ§Ä¡ ±¸¼ºÀ» º¯°æÇÏÁö ¸øÇϵµ·Ï Á¦ÇÑÇÕ´Ï´Ù.
  •  »ç¿ëÀÚ°¡ ¼±Åà °¡´ÉÇÑ ÁÖ¼Ò ÀÎ½Ä ¸ðµå´Â ±¸¼ºÀ» °£¼ÒÈ­ÇÏ°í º¸¾ÈÀ» °­È­Çß½À´Ï´Ù.
  •  BPDU Guard´Â ¿ì¹ßÀûÀÎ ÅäÆú·ÎÁö ·çÇÁ¸¦ ¿¹¹æÇϵµ·Ï BPDU¸¦ ¹Þ¾ÒÀ» ¶§ ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ PortFast Áö¿ø ÀÎÅÍÆäÀ̽º¸¦ Á¾·áÇÕ´Ï´Ù.
  •  STRG(Spanning-Tree Root Guard)´Â ³×Æ®¿öÅ© °ü¸®ÀÚÀÇ Á¦¾î ÇÏ¿¡ ÀÖÁö ¾ÊÀº ¿¡Áö ÀåÄ¡°¡ ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ(STP) ·çÆ® ³ëµå°¡ µÇÁö ¸øÇϵµ·Ï ¹æÁöÇÕ´Ï´Ù.
  •  À½¼º VLAN Áö°¢ Æ÷Æ® º¸¾È ¹× BPDU Guard¸¦ »ç¿ëÇÏ¸é º¸¾È À§¹Ý »ç·Ê°¡ ¹ß»ýÇßÀ» ¶§ À½¼º VLAN Æ®·¡ÇÈÀ» ÆÄ±«ÇÏÁö ¾Êµµ·Ï ¿¹¹æÇÕ´Ï´Ù.
  •  IGMP ÇÊÅ͸µÀº ºñµî·ÏÀÚ¸¦ Â÷´ÜÇÏ¿© ¸ÖƼij½ºÆ® ÀÎÁõÀ» Á¦°øÇϸç, Æ÷Æ®´ç »ç¿ë °¡´ÉÇÑ µ¿½Ã ¸ÖƼij½ºÆ® ½ºÆ®¸²ÀÇ °³¼ö¸¦ Á¦ÇÑÇÕ´Ï´Ù.
  •  µ¿Àû VLAN ÇÒ´çÀº VMPS(VLAN Membership Policy Server) Ŭ¶óÀÌ¾ðÆ® ±â´ÉÀÇ ±¸ÇöÀ» ÅëÇØ VLAN¿¡ Æ÷Æ®¸¦ ÇÒ´çÇÒ ¶§ À¯¿¬¼ºÀ» Á¦°øÇÕ´Ï´Ù. µ¿Àû VLANÀ» »ç¿ëÇϸé IP ÁÖ¼Ò¸¦ ºü¸£°Ô ÇÒ´çÇÒ ¼ö ÀÖ½À´Ï´Ù.
  •  Cisco Network Assistant ¼ÒÇÁÆ®¿þ¾î º¸¾È ¸¶¹ý»ç´Â ¼­¹ö³ª ÀϺΠ³×Æ®¿öÅ© ¶Ç´Â Àüü ³×Æ®¿öÅ©¿¡ ´ëÇÑ »ç¿ëÀÚ ¾×¼¼½º¸¦ Á¦ÇÑÇϱâ À§ÇØ º¸¾È ±â´ÉÀ» ½±°Ô ¹èÄ¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
Ç¥ 2. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ Çϵå¿þ¾î
¼³¸í »ç¾ç
¼º´É
  •  16Gbps ½ºÀ§Äª ÆÐºê¸¯(Catalyst 2960-24-S, Catalyst 2960-24TC-S, Catalyst 2960-48TC-S)
  •  64¹ÙÀÌÆ® ÆÐŶ ±âÁØ Æ÷¿öµù ¼Óµµ:
  •  Catalyst 2960-24-S: 3.6Mpps
  •  Catalyst 2960-24TC-S: 6.5Mpps
  •  Catalyst 2960-48TC-S: 10.1Mpps
  •  64MB DRAM
  •  32MB Ç÷¡½Ã ¸Þ¸ð¸®
  •  ÃÖ´ë 8000°³ MAC ÁÖ¼Ò ±¸¼º °¡´É
  •  ÃÖ´ë 255°³ IGMP ±×·ì ±¸¼º °¡´É
  •  ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ® ºê¸®Áö¿ëÀ¸·Î ÃÖ´ë 9018¹ÙÀÌÆ®(Á¡º¸ ÇÁ·¹ÀÓ)ÀÇ ÀÌ´õ³Ý ÇÁ·¹ÀÓ Å©±â¸¦ °¡Áø ÃÖ´ë 9000¹ÙÀÌÆ®ÀÇ MTU(Maximum Transmission Unit) ±¸¼º °¡´É. ¶ÇÇÑ 10/100 ¹× 10/100/1000 Æ÷Æ®»ó¿¡ Multiprotocol ·¹ÀÌºí ½ºÀ§Äª(MPLS) ÅÂ±× ÇÁ·¹ÀÓ ºê¸®Áö¿ëÀ¸·Î ÃÖ´ë 1998¹ÙÀÌÆ® ±¸¼º °¡´É.
Ä¿³ØÅÍ ¹× ÄÉÀ̺í
  •  10BASE-T Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 2½Ö Ä«Å×°í¸® 3, 4 ¶Ç´Â 5 UTP(Unshielded Twisted Pair) ÄÉÀ̺í
  •  100BASE-TX Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 2½Ö Ä«Å×°í¸® 5 UTP ÄÉÀ̺í
  •  1000BASE-T Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 4½Ö Ä«Å×°í¸® 5 UTP ÄÉÀ̺í
  •  1000BASE-T SFP ±â¹Ý Æ÷Æ®: RJ-45 Ä¿³ØÅÍ, 4½Ö Ä«Å×°í¸® 5 UTP ÄÉÀ̺í
  •  1000BASE-SX, -LX/LH SFP ±â¹Ý Æ÷Æ®: LC ÆÄÀ̹ö Ä¿³ØÅÍ(´ÜÀÏ/¸ÖƼ¸ðµå ÆÄÀ̹ö)
  •  100BASE-FX: LC ÆÄÀ̹ö Ä¿³ØÅÍ(´ÜÀÏ/¸ÖƼ¸ðµå ÆÄÀ̹ö)
Àü¿ø Ä¿³ØÅÍ
  •  °í°´ÀÌ ³»ºÎ Àü¿ø °ø±Þ ÀåÄ¡¸¦ »ç¿ëÇÏ¿© ½ºÀ§Ä¡¿¡ Àü¿øÀ» °ø±ÞÇÒ ¼ö ÀÖ½À´Ï´Ù. Ä¿³ØÅÍ´Â ½ºÀ§Ä¡ Èĸ鿡 ÀÖ½À´Ï´Ù. ÀÌ·¯ÇÑ ½ºÀ§Ä¡¿¡´Â RPS Æ÷Æ®°¡ ¾ø½À´Ï´Ù.
  •  ³»ºÎ Àü¿ø °ø±Þ ÀåÄ¡´Â ÀÚµ¿À¸·Î ¹üÀ§ ¼³Á¤µÇ´Â À¯´ÖÀÔ´Ï´Ù.
  •  ³»ºÎ Àü¿ø °ø±Þ ÀåÄ¡´Â 100~240 VACÀÇ ÀÔ·Â Àü¾ÐÀ» Áö¿øÇÕ´Ï´Ù.
  •  Á¦°øµÇ´Â AC Àü¿ø Äڵ带 »ç¿ëÇÏ¿© AC Àü¿ø Ä¿³ØÅ͸¦ AC Àü¿ø Äܼ¾Æ®¿¡ ¿¬°áÇÕ´Ï´Ù.
Ç¥½Ã ÀåÄ¡
  •  Æ÷Æ®º° »óÅÂ: ¸µÅ© ¹«°á¼º, »ç¿ë ¾È ÇÔ, ÀÛ¾÷, ¼Óµµ ¹× ÀüÀÌÁß
  •  ½Ã½ºÅÛ »óÅÂ: ½Ã½ºÅÛ, ¸µÅ© »óÅÂ, ¸µÅ© ÀÌÁß, ¸µÅ© ¼Óµµ
±Ô°Ý(H x W x D)
  •  Cisco Catalyst 2960-24-S: 1.73 x 17.5 x 9.3ÀÎÄ¡(4.4 x 44.5 x 23.6cm)
  •  Cisco Catalyst 2960-24TC-S: 1.73 x 17.5 x 9.3ÀÎÄ¡(4.4 x 44.5 x 23.6cm)
  •  Cisco Catalyst 2960-48TC-S: 1.73 x 17.5 x 9.3ÀÎÄ¡(4.4 x 44.5 x 23.6cm)
¹«°Ô
  •  Cisco Catalyst 2960-24-S: 3.6kg(8lb)
  •  Cisco Catalyst 2960-24TC-S: 3.6kg(8lb)
  •  Cisco Catalyst 2960-48TC-S: 3.6kg(8lb)
ȯ°æ ¹üÀ§
  •  ÀÛµ¿ ¿Âµµ: 32~113°F(0~45°C)
  •  º¸°ü ¿Âµµ: -13~158°F(-25~70°C)
  •  ÀÛµ¿ »ó´ë ½Àµµ: 10~85%(ºñÀÀÃà)
  •  ÀÛµ¿ °íµµ: ÃÖ´ë 10,000ft(3049m)
  •  º¸°ü °íµµ: ÃÖ´ë 15,000 ft(4573m)
À½ÆÄ ¼ÒÀ½
  •  ISO 7779: ÁÖº¯ ¿Âµµ 25¡ÆC·Î ÀÛµ¿ÇÏ´Â Bystander À§Ä¡
  •  Cisco Catalyst 2960-24-S: 40dBa
  •  Cisco Catalyst 2960-24TC-S: 40dBa
  •  Cisco Catalyst 2960-48TC-S: 40dBa
MTBF(Æò±Õ Àå¾Ö ¹ß»ý ½Ã°£)
  •  Cisco Catalyst 2960-24-S: 429,847½Ã°£
  •  Cisco Catalyst 2960-24TC-S: 403,745½Ã°£
  •  Cisco Catalyst 2960-48TC-S: 336,983½Ã°£
Ç¥ 3. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ Àü¿ø »ç¾ç
¼³¸í »ç¾ç
ÃÖ´ë Àü¿ø ¼Ò¸ð·®
  •  Cisco Catalyst 2960-24-S: 30W, ½Ã°£´ç 103BTU
  •  Cisco Catalyst 2960-24TC-S: 30W, ½Ã°£´ç 103BTU
  •  Cisco Catalyst 2960-48TC-S: 45W, ½Ã°£´ç 154BTU
AC ÀÔ·Â Àü¾Ð ¹× Àü·ù
  •  100-240VAC(ÀÚµ¿ ¹üÀ§), 1.3-0.8A, 50-60Hz
  •  À¯ÀÔ Àü·ù < 30A(115VAC) ¹× < 60A(230VAC)
Á¤°Ý Àü¾Ð
  •  Cisco Catalyst 2960-24-S: 0.05kVA
  •  Cisco Catalyst 2960-24TC-S: 0.05kVA
  •  Cisco Catalyst 2960-48TC-S: 0.075kVA
Ç¥ 4. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡¸¦ À§ÇÑ °ü¸® ¹× Ç¥ÁØ Áö¿ø
¼³¸í »ç¾ç
°ü¸®
  •  BRIDGE-MIB
  •  CISCO-CABLE-DIAG-MIB
  •  CISCO-CDP-MIB
  •  CISCO-CLUSTER-MIB
  •  CISCO-CONFIG-COPY-MIB
  •  CISCO-CONFIG-MAN-MIB
  •  CISCO-ENTITY-VENDORTYPE-OID-MIB
  •  CISCO-ENVMON-MIB
  •  CISCO-ERR-DISABLE-MIB
  •  CISCO-FLASH-MIB
  •  CISCO-FTP-CLIENT-MIB
  •  CISCO-IGMP-FILTER-MIB
  •  CISCO-IMAGE-MIB
  •  CISCO-IP-STAT-MIB
  •  CISCO-LAG-MIB
  •  CISCO-MAC-NOTIFICATION-MIB
  •  CISCO-MEMORY-POOL-MIB
  •  CISCO-PAGP-MIB
  •  CISCO-PING-MIB
  •  CISCO-PORT-QOS-MIB
  •  CISCO-PORT-SECURITY-MIB
  •  CISCO-PORT-STORM-CONTROL-MIB
  •  CISCO-PRODUCTS-MIB
  •  CISCO-PROCESS-MIB
  •  CISCO-RTTMON-MIB
  •  CISCO-SMI-MIB
  •  CISCO-STP-EXTENSIONS-MIB
  •  CISCO-SYSLOG-MIB
  •  CISCO-TC-MIB
  •  CICSO-TCP-MIB
  •  CISCO-UDLDP-MIB
  •  CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
  •  CISCO-VLAN-MEMBERSHIP-MIB
  •  CISCO-VTP-MIB
  •  ENTITY-MIB
  •  ETHERLIKE-MIB
  •  IEEE8021-PAE-MIB
  •  IEEE8023-LAG-MIB
  •  IF-MIB
  •  INET-ADDRESS-MIB
  •  OLD-CISCO-CHASSIS-MIB
  •  OLD-CISCO-FLASH-MIB
  •  OLD-CISCO-INTERFACES-MIB
  •  OLD-CISCO-IP-MIB
  •  OLD-CISCO-SYS-MIB
  •  OLD-CISCO-TCP-MIB
  •  OLD-CISCO-TS-MIB
  •  RFC1213-MIB
  •  RMON-MIB
  •  RMON2-MIB
  •  SNMP-FRAMEWORK-MIB
  •  SNMP-MPD-MIB
  •  SNMP-NOTIFICATION-MIB
  •  SNMP-TARGET-MIB
  •  SNMPv2-MIB
  •  TCP-MIB
  •  UDP-MIB
Ç¥ÁØ
  •  IEEE 802.1D ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ
  •  IEEE 802.1p CoS ¿ì¼±¼øÀ§ ÁöÁ¤
  •  IEEE 802.1Q VLAN
  •  IEEE 802.1s
  •  IEEE 802.1w
  •  IEEE 802.1x
  •  IEEE 802.1AB(LLDP)
  •  IEEE 802.3ad
  •  IEEE 802.3ah(100BASE-X ´ÜÀÏ/¸ÖƼ¸ðµå ÆÄÀ̹ö¸¸)
  •  0BASE-T, 100BASE-TX ¹× 1000BASE-T Æ÷Æ®»ó¿¡¼­ IEEE 802.3x ÀüÀÌÁß
  •  IEEE 802.3 10BASE-T »ç¾ç
  •  IEEE 802.3u 100BASE-TX »ç¾ç
  •  IEEE 802.3ab 1000BASE-T »ç¾ç
  •  IEEE 802.3z 1000BASE-X »ç¾ç
  •  100BASE-FX(SFP)
  •  1000BASE-SX(SFP)
  •  1000BASE-LX/LH(SFP)
  •  RMON I ¹× II Ç¥ÁØ
  •  SNMPv1, SNMPv2c ¹× SNMPv3
Ç¥ 5. ¾ÈÀü ¹× ÀûÇÕ¼º
¼³¸í »ç¾ç
¾ÈÀü ÀÎÁõ
  •  UL 60950-1, Á¦1ÆÇ
  •  CUL~CAN/CSA 22.2 No. 60950-1, Á¦1ÆÇ
  •  TUV/GS to EN 60950-1, Á¦1ÆÇ
  •  CB to IEC 60950-1(¸ðµç ±¹°¡ ÆíÂ÷ Àû¿ë)
  •  AS/NZS 60950-1, Á¦1ÆÇ
  •  CE Ç¥½Ã
  •  NOM(½Ã½ºÄÚ ÆÄÆ®³Ê ¹× ÃÑÆÇ»ç °æÀ¯)
ÀüÀÚ±â ȣȯ¼º ÀÎÁõ
  •  FCC Part 15 Class A
  •  EN 55022 Class A(CISPR22)
  •  EN 55024(CISPR24)
  •  AS/NZS CISPR22 Class A
  •  CE
  •  CNS13438 Class A
  •  MIC
  •  GOST
  •  China EMC ÀÎÁõ
ȯ°æ Á¶°Ç À§Çè ¹°Áú °¨¼Ò(ROHS) 5
Telco CLEI(Common Language Equipment Identifier) ÄÚµå
º¸Áõ Á¦ÇÑÀûÀÎ Çϵå¿þ¾î º¸Áõ Á¦°ø
½Ã½ºÄÚ ½Ã½ºÅÛÁî´Â ÃѼÒÀ¯ºñ¿ë(TCO)À» ÃÖ¼ÒÈ­Çϱâ À§ÇØ ÃÑ·ÂÀ» ´ÙÇϰí ÀÖ½À´Ï´Ù. ½Ã½ºÄÚ Á¦Ç°ÀÌ È¿À²ÀûÀ¸·Î ÀÛµ¿Çϰí, °í°¡¿ë¼ºÀ» À¯ÁöÇϸç, ÃֽŠ½Ã½ºÅÛ ¼ÒÇÁÆ®¿þ¾î¸¦ »ç¿ëÇÒ ¼ö ÀÖµµ·Ï ´Ù¾çÇÑ ±â¼ú Áö¿ø ¼­ºñ½º¸¦ Á¦°øÇÕ´Ï´Ù. Ç¥ 6¿¡ ¼³¸íµÈ ¼­ºñ½º¿Í Áö¿ø ÇÁ·Î±×·¥Àº Cisco Desktop Switching Service and Support(½Ã½ºÄÚ µ¥½ºÅ©Å¾ ½ºÀ§Äª ¼­ºñ½º ¹× Áö¿ø) ¼Ö·ç¼ÇÀÇ ÀÏȯÀ¸·Î Á¦°øµÇ¸ç, ½Ã½ºÄڷκÎÅÍ Á÷Á¢ Áö¿øÀ» ¹Þ°Å³ª ÆÄÆ®³Ê»ç¸¦ ÅëÇØ Áö¿ø ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù.
Ç¥ 6. ½Ã½ºÄÚ ¼­ºñ½º ¹× Áö¿ø ÇÁ·Î±×·¥
¼­ºñ½º ¹× Áö¿ø ±â´É ÀÌÁ¡
  •  Cisco TIS(Total Implementation Solutions), ½Ã½ºÄÚ Á÷Á¢ Á¦°ø
  •  Cisco Packaged TIS, ¸®¼¿·¯ Á¦°ø
  •  Cisco SMARTnet® ¹× SMARTnetÇöÀå Áö¿ø, ½Ã½ºÄÚ Á÷Á¢ Á¦°ø
  •  Cisco Packaged SMARTnet Áö¿ø ÇÁ·Î±×·¥, ¸®¼¿·¯ Á¦°ø
  •  Cisco SMB Support Assistant
  •  ÇÁ·ÎÁ§Æ® °ü¸®
  •  ÇöÀå Á¶»ç, ±¸¼º ¹× ¹èÄ¡
  •  ¼³Ä¡, ÅØ½ºÆ® ¹× Â÷´Ü(cutover)
  •  ±³À°
  •  ÁÖ¿ä Àüȯ, Ãß°¡ ¹× º¯°æ
  •  ¼³°è °ËÅä ¹× Á¦Ç° Áغñ
  •  24½Ã°£ ¾×¼¼½º °¡´ÉÇÑ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ®
  •  ±â¼ú ÀÚ·á¿¡ ´ëÇÑ À¥ ¾×¼¼½º
  •  ½Ã½ºÄÚ ±â¼ú Áö¿ø ¼¾ÅÍ(TAC)¸¦ ÅëÇÑ Áö¼ÓÀûÀÎ ±â¼ú Áö¿ø
  •  Çϵå¿þ¾î ºÎǰÀÇ °í±Þ ¹èÄ¡
  •  ±âÁ¸ Á÷¿ø º¸Ãæ
  •  ±â´ÉÀÌ ¿ä±¸»çÇ×À» ÃæÁ·Çϵµ·Ï º¸Àå
  •  À§Çè °æ°¨
  •  ´Éµ¿ÀûÀÌ°í ½Å¼ÓÇÑ ¹®Á¦ ÇØ°á Áö¿ø
  •  ½Ã½ºÄÚ Àü¹® ±â¼ú ¹× Áö½ÄÀ» Ȱ¿ëÇÏ¿© TCO Àý°¨ È¿°ú
  •  ³×Æ®¿öÅ© Áß´Ü ½Ã°£ ÃÖ¼ÒÈ­
Ç¥ 7¿¡¼­´Â Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ ÁÖ¹® Á¤º¸¸¦ ¼³¸íÇÕ´Ï´Ù.
Ç¥ 7. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ ÁÖ¹® Á¤º¸
ºÎǰ ¹øÈ£ ¼³¸í
WS-C2960-24-S
  •  ÀÌ´õ³Ý 10/100 Æ÷Æ® 24°³
  •  1 RU °íÁ¤ ±¸¼º
  •  LAN Lite À̹ÌÁö ¼³Ä¡
WS-C2960-24TC-S
  •  24°³ÀÇ ÀÌ´õ³Ý 10/100 Æ÷Æ® ¹× 2°³ÀÇ ÀÌÁß ¸ñÀû ¾÷¸µÅ©(°¢ ÀÌÁß ¸ñÀû ¾÷¸µÅ©¿¡´Â 10/100/1000 ÀÌ´õ³Ý Æ÷Æ®¿Í SFP ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®°¡ °¢°¢ 1°³¾¿ ÀÖÀ¸¸ç, 1°³ÀÇ Æ÷Æ®¸¸ Ȱ¼ºÈ­ °¡´ÉÇÔ)
  •  1 RU °íÁ¤ ±¸¼º
  •  LAN Lite À̹ÌÁö ¼³Ä¡
  •  48°³ÀÇ ÀÌ´õ³Ý 10/100 Æ÷Æ® ¹× 2°³ÀÇ ÀÌÁß ¸ñÀû ¾÷¸µÅ©(°¢ ÀÌÁß ¸ñÀû ¾÷¸µÅ©¿¡´Â 10/100/1000 ÀÌ´õ³Ý Æ÷Æ®¿Í SFP ±â¹Ý ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®°¡ °¢°¢ 1°³¾¿ ÀÖÀ¸¸ç, 1°³ÀÇ Æ÷Æ®¸¸ Ȱ¼ºÈ­ °¡´ÉÇÔ)
  •  1 RU °íÁ¤ ±¸¼º
  •  LAN Lite À̹ÌÁö ¼³Ä¡
RCKMNT-1RU= Cisco Catalyst 2960 ½Ã¸®Áî¿ë ¿©ºÐÀÇ ·¢¸¶¿îÆ® ÀåÂø
RCKMNT-REC-1RU= Cisco Catalyst 2960 ½Ã¸®Áî¿ë 1 RU ¿À¸ñÇü ·¢ ÀåÂø ŰƮ
GLC-LH-SM= MMF ¹× SMF¿ë 1000BASE-LX/LH SFP Æ®·£½Ã¹ö ¸ðµâ, 1300nm ÆÄÀå
GLC-SX-MM= MMF¿ë 1000BASE-SX SFP ¼Û¼ö½Å±â ¸ðµâ, 850nm ÆÄÀå
GLC-T= Category 5 ÄÚÆÛ ¿ÍÀ̾î¿ë 1000BASE-T SFP ¼Û¼ö½Å±â ¸ðµâ
GLC-GE-100FX= ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®¿ë 100BASE-FX SFP ¸ðµâ, 1310nm ÆÄÀå, 2km MMF
GLC-FE-100FX= 100MB Æ÷Æ®¿ë 100BASE-FX SFP ¸ðµâ, 1310nm ÆÄÀå, 2km MMF
CAB-SM-LCSC-1M 1M ÆÄÀ̹ö ´ÜÀϸðµå LC-T0-SC Ä¿³ØÅÍ
CAB-SM-LCSC-5M 5M ÆÄÀ̹ö ´ÜÀϸðµå LC-T0-SC Ä¿³ØÅÍ
½Ã½ºÄÚ Á¦Ç°¿¡ ´ëÇÑ ÀÚ¼¼ÇÑ ³»¿ëÀº ´ÙÀ½ ¿¬¶ôó·Î ¹®ÀÇÇϽʽÿÀ.
  •  ¹Ì±¹ ¹× ij³ª´Ù: 800 553- 6387(¼ö½ÅÀÚ ºÎ´ã)
  •  À¯·´: 32 2 778 4242
  •  È£ÁÖ: 612 9935 4107
  •  Çѱ¹: 080-808-8082
  •  URL: http://www.cisco.com/kr

Cisco¿¡ ¹®ÀÇÇϼ¼¿ä


  • ÀϹݹ®ÀÇ 080-377-0880
    Á¦Ç°/±¸¸Å 080-808-8082