::: Cisco :::
 |
|
 |
|
| Cisco Catalyst 2960 ½ºÀ§Ä¡(LAN Lite ¼ÒÇÁÆ®¿þ¾î Æ÷ÇÔ) |
| Cisco® XR 12000 ½Ã¸®Áî ¹× Cisco 12000 ½Ã¸®Áî ¶ó¿ìÅÍ´Â ½½·Ô´ç 2.5Gbps¿¡¼ (N x 10)Gbps·Î È®Àå °¡´ÉÇÑ ÀÚü Á¤º¸Ã³¸® ´É·ÂÀ» °¡Áø ¶ó¿ìÆÃ ¼Ö·ç¼ÇÀ¸·Î ±¸¼ºµÈ Æ÷Æ®Æú¸®¿À·Î, Åë½Å»ç¾÷ÀÚ±Þ(carrier-class) IP/MPLS(Multiprotocol Label Switching) ³×Æ®¿öÅ©¸¦ Áö¿øÇϰí IP Â÷¼¼´ë ³×Æ®¿öÅ©·ÎÀÇ ÀüȯÀ» °¡¼ÓÈÇÕ´Ï´Ù. ÅõÀÚ º¸È£(investment protection)¸¦ ±âº» ¹ÙÅÁÀ¸·Î ±¸ÃàµÈ ÀÌ Æ÷Æ®Æú¸®¿À´Â ÃÊ´ç ÃÖ´ë 1.28TBÀÇ ½ºÀ§Äª ¼º´É°ú ÇÔ²² À¯¼± ¼Óµµ(wire-speed)ÀÇ ¼º´É, È®À强 ¹× ¾ÈÁ¤ÀûÀÎ Çϵå¿þ¾î/¼ÒÇÁÆ®¿þ¾î ¾÷±×·¹ÀÌµå °æ·Î¸¦ Á¦°øÇÕ´Ï´Ù. |
|
|
 |
|
 |
|
| ÀÌ Æ÷Æ®Æú¸®¿ÀÀÇ ¶ó¿ìÅÍ´Â ¿Ïº®ÇÑ ºÐ»ê Æ÷¿öµù ¾ÆÅ°ÅØÃ³¿Í °íÈ¿À² Å©·Î½º¹Ù ½ºÀ§Ä¡ ÆÐºê¸¯À» ÅëÇØ ±â´É°ú ¼ºñ½º¸¦ Á¦°øÇÕ´Ï´Ù(±×¸² 1). ½ºÀ§Ä¡ ÆÐºê¸¯ ´ë¿ªÆø »ç¿ëÀ» ÃÖ´ëÈÇϰí, Áö¿¬À²À» ÃÖ¼ÒÈÇϸç, Àå¾Ö ¾ø´Â ¼º´ÉÀ» Á¦°øÇϱâ À§ÇØ Áß¾Ó ÁýÁßÈµÈ ½ºÄÉÁÙ·¯ ¹× °íÀ¯ÇÑ VOQ(Virtual Output queuing) ±â¼úÀ» °áÇÕÇß½À´Ï´Ù. ½Ã½ºÄÚ ½Ã½ºÅÛÁî´Â ƯÁ¤ ¿ëµµÀÇ Á÷Á¢ ȸ·ÎÀÎ °í¼º´É ASIC(Application-Specific Integrated Circuit) Ãֽбâ¼úÀ» ÅëÇØ ½Ç½Ã°£ ¼ºñ½º¸¦ Á¦°øÇϴµ¥ ¹Ýµå½Ã ÇÊ¿äÇÑ ÁöÅÍ(jitter)¿Í Áö¿¬À²ÀÇ Á¦¾î¸¦ ¾ö°ÝÇÏ°Ô Àû¿ëÇϸé¼, ´Ù¾çÇÑ ±â´É ¼¼Æ®¿Í ÇÔ²² ¶óÀÎ ¼Óµµ Æ÷¿öµùÀ» Á¦°øÇÕ´Ï´Ù. Cisco XR 12000 ½Ã¸®Áî ¹× 12000 ½Ã¸®Áî ¶ó¿ìÅÍ´ÂQoS(quality-of-service), IP/MPLS ¹× °í°¡¿ë¼º ±â´ÉÀ» °®Ãá Á¾ÇÕÀûÀÎ ¼¼Æ® ±¸¼ºÀ¸·Î ¾ö°ÝÇÑ °í°´ ¼ºñ½º ¼öÁØ °è¾à(SLA)À» ÃæÁ·½ÃŰ¸é¼µµ ´ë¿ªÆø »ç¿ë°ú Æ®·¡ÇÈ ºÐ»êÀ» ÃÖ´ëÈÇÕ´Ï´Ù. |
| Cisco XR 12000 ½Ã¸®Áî ¹× 12000 ½Ã¸®Áî ¶ó¿ìÅÍ´Â Cisco IOS¢ç XR Software¿Í Cisco IOS Software¸¦ °¢°¢ »ç¿ëÇÏ¿© ³×Æ®¿öÅ© »ç¾÷ÀÚ¿¡°Ô ´Ù¾çÇÑ ¼ºñ½º¸¦ Áö¿øÇÒ ¼ö ÀÖ´Â °¡´É¼ºÀ» Á¦°øÇÕ´Ï´Ù. ½Ã½ºÄÚ´Â ÇÏÀÌ¿£µå ¶ó¿ìÆÃ Á¦Ç°±º¿¡ Cisco XR 12000 ½Ã¸®Á Ãß°¡ÇÔÀ¸·Î½á, ÅëÇÕ IP Â÷¼¼´ë ³×Æ®¿öÅ© ÀÎÇÁ¶ó·ÎÀÇ ÀüȯÀ» ÅëÇØ Cisco 12000 ½Ã¸®Áî ¶ó¿ìÅÍÀÇ ¼³Ä¡ ±â¹Ý¿¡ ´ëÇÑ ¾ÈÁ¤ÀûÀÎ ¾÷±×·¹ÀÌµå °æ·Î¸¦ Á¦°øÇÕ´Ï´Ù. ÀÌ·¯ÇÑ ¶ó¿ìÅÍ¿¡¼ »ç¿ëµÇ´Â Cisco IOS XR ¹× Cisco IOS Software¿¡ ´ëÇÑ ±â´É Áö¿ø, ¼ÒÇÁÆ®¿þ¾î ±â´É, ȣȯ¼º ¹× ¸±¸®½º ³ëÆ® ¸ñ·ÏÀ» º¸·Á¸é http://www.cisco.com/go/12000 »çÀÌÆ®¸¦ ÂüÁ¶ÇϽʽÿÀ. |
| ±×¸² 1. Cisco XR 12000 ¹× 12000 ½Ã¸®Áî ¶ó¿ìÆÃ Æ÷Æ®Æú¸®¿À |
 |
Ç¥ 1. Cisco Catalyst 2960 LAN Lite ½ºÀ§Ä¡ÀÇ ±â´É°ú ÀÌÁ¡
|
| Á¦Ç° »ç¾ç |
Cisco XR 12000 ¹× 12000 ½Ã¸®Áî 16½½·Ô ¼¨½Ã |
Cisco XR 12000 ¹× 12000 ½Ã¸®Áî 10½½·Ô ¼¨½Ã |
Cisco XR 12000 ¹× 12000 ½Ã¸®Áî 6½½·Ô ¼¨½Ã |
Cisco XR 12000 ¹× 12000 ½Ã¸®Áî 4½½·Ô ¼¨½Ã |
| ½½·Ô ¿ë·® |
16½½·Ô |
10½½·Ô |
6½½·Ô |
4½½·Ô |
| ÃÑ ½ºÀ§Äª ¿ë·® |
Cisco 12016: 80Gbps Cisco 12416: 320Gbps Cisco 12816: 1280Gbps |
Cisco 12010: 50Gbps Cisco 12410: 200Gbps Cisco12810: 800Gbps |
Cisco 12006: 30Gbps Cisco 12406: 120Gbps |
Cisco 12404: 80Gbps |
| ½½·Ô´ç ÀüÀÌÁß Ã³¸®·® |
Cisco 12016: ½½·Ô´ç 2.5Gbps Cisco 12416: ½½·Ô´ç 10Gbps Cisco 12816: ½½·Ô´ç 40Gbps |
Cisco 12010: ½½·Ô´ç 2.5Gbps Cisco 12410: ½½·Ô´ç 10Gbps Cisco 12810: ½½·Ô´ç 40Gbps |
Cisco 12006: ½½·Ô´ç 2.5Gbps Cisco 12406: ½½·Ô´ç 10Gbps
|
Cisco 12404: ½½·Ô´ç 10Gbps |
| ¹°¸®Àû »ç¾ç |
¼¨½Ã ³ôÀÌ 71.5ÀÎÄ¡(181.6cm) 72.5ÀÎÄ¡(184.2cm)¹
¼¨½Ã Æø 17.25ÀÎÄ¡(43.8cm) 18.75ÀÎÄ¡(47.63cm)²
¼¨½Ã ±íÀÌ 22ÀÎÄ¡(55.9cm) 24ÀÎÄ¡(61cm)³
¹«°Ô 64kg(140 lb)4 177kg(390 lb)5
|
¼¨½Ã ³ôÀÌ 37.5ÀÎÄ¡(95.25cm)
¼¨½Ã Æø 19ÀÎÄ¡(48.26cm)
¼¨½Ã ±íÀÌ 22ÀÎÄ¡(55.9cm) 24ÀÎÄ¡(61cm)
¹«°Ô 57kg(125 lb) 125kg(275 lb)
|
¼¨½Ã ³ôÀÌ 18.5ÀÎÄ¡(47.0cm)
¼¨½Ã Æø 17.3ÀÎÄ¡(43.9cm) 18.9ÀÎÄ¡(48cm)
¼¨½Ã ±íÀÌ 28ÀÎÄ¡(71.1cm)
¹«°Ô 64kg(140 lb) 94kg(205 lb)
|
¼¨½Ã ³ôÀÌ 8.75ÀÎÄ¡(22.23cm)
¼¨½Ã Æø 17.38ÀÎÄ¡(44.15cm) 18.9ÀÎÄ¡(48.01cm)
¼¨½Ã ±íÀÌ 27.5ÀÎÄ¡(69.85cm)
¹«°Ô 33.18kg(73 lb) 46.82kg(103 lb)
|
| ·¢´ç ¼¨½Ã ¼ö |
1°³ |
2°³ |
4°³ |
8°³ |
| AC ÀÔ·Â Àü¿ø Àü±â »ç¾ç |
| ÃÑ AC ÀÔ·Â |
¼¨½Ã´ç |
¼¨½Ã´ç |
Àú¾Ð ¶óÀÎ |
¼¨½Ã´ç |
| Àü¿ø |
4651VA(ÃÖ´ë) |
2790VA(ÃÖ´ë) |
1708VA(ÃÖ´ë) ¼¨½Ã´ç °í¾Ð ¶óÀÎ 1950VA(ÃÖ´ë) |
1341VA(ÃÖ´ë) |
| Á¤°Ý ÀÔ·Â Àü¾Ð |
200-240VAC, °øÄª(¹üÀ§: 180-264VAC) |
200-240VAC, °øÄª(¹üÀ§: 180-264VAC) |
100-120VAC(Àú¾Ð ¶óÀÎ), 200-240VAC(°í¾Ð ¶óÀÎ), °øÄª(¹üÀ§: 85-264VAC) |
100-120VAC(Àú¾Ð ¶óÀÎ), 200-240VAC(°í¾Ð ¶óÀÎ), °øÄª(¹üÀ§: 85-264VAC) |
| Á¤°Ý ÀÔ·Â ¶óÀÎ Á֯ļö |
50-60Hz, °øÄª(¹üÀ§: 47-63Hz) |
50-60Hz, °øÄª(¹üÀ§: 47-63Hz) |
50-60Hz, °øÄª(¹üÀ§: 47-63Hz) |
50-60Hz, °øÄª(¹üÀ§: 47-63Hz) |
| ÀÔ·Â Àü·ù (¸ðµç ¶óÀÎ Äڵ忡 ´ëÇØ) |
ÃÖ´ë 10.3A @ 240VAC |
ÃÖ´ë 11.6A @ 240VAC |
ÃÖ´ë 17.2A @ 100VAC ÃÖ´ë 10A @ 200VAC |
ÃÖ´ë 6A @ 240VAC |
| ¼Ò½º AC ¼ºñ½º ¿ä±¸»çÇ× |
20A ºÏ¹Ì, 16A ±¹Á¦ |
20A ºÏ¹Ì, 16A ±¹Á¦ |
20A ºÏ¹Ì, 16A ±¹Á¦ |
20A ºÏ¹Ì, 16A ±¹Á¦ |
| DC ÀÔ·Â Àü¿ø Àü±â »ç¾ç |
| ÃÑ DC ÀÔ·Â Àü·Â |
4212W(ÃÖ´ë) |
2430W(ÃÖ´ë) |
1630W(ÃÖ´ë) |
1280W(ÃÖ´ë) |
| Á¤°Ý ÀÔ·Â Àü¾Ð |
-48VDC, °øÄª(ºÏ¹Ì) |
-48VDC, °øÄª(ºÏ¹Ì) |
-48VDC, °øÄª(ºÏ¹Ì) |
-48VDC, °øÄª(ºÏ¹Ì) |
| -60VDC, °øÄª, À¯·´ ¿¬ÇÕ(¹üÀ§: -40.5 ~ -75VDC) |
-60VDC, °øÄª, À¯·´ ¿¬ÇÕ(¹üÀ§: -40.5 ~ -75VDC) |
-60VDC, °øÄª, À¯·´ ¿¬ÇÕ(¹üÀ§: -40.5 ~ -75VDC) |
-60VDC, °øÄª, À¯·´ ¿¬ÇÕ(¹üÀ§: -40.5 ~ -75VDC) |
| ÀÔ·Â Àü·ù (¸ðµç DC ÀÔ·Â ½Ö¿¡ ´ëÇØ) |
ÃÖ´ë 52A @ 40.5VDC |
ÃÖ´ë 60A @ 40.5VDC |
ÃÖ´ë 45A @ 40.5VDC |
ÃÖ´ë 35A @ 40.5VDC |
| ¼Ò½º DC ¼ºñ½º ¿ä±¸»çÇ× |
60A |
60A |
60A |
60A |
| ȯ°æ Á¶°Ç |
| ¿Âµµ |
ÀÛµ¿: 32 ~ 104°F(0 ~ 40°C) ºñÀÛµ¿: -4 ~ 149°F(-20 ~ 65°C) |
ÀÛµ¿: 32 ~ 104°F(0 ~ 40°C) ºñÀÛµ¿: -4 ~ 149°F(-20 ~ 65°C) |
ÀÛµ¿: 32 ~ 104°F(0 ~ 40°C) ºñÀÛµ¿: -4 ~ 149°F(-20 ~ 65°C) |
ÀÛµ¿: 32 ~ 104°F(0 ~ 40°C) ºñÀÛµ¿: -40 ~ 158°F(-40 ~ 70°C) |
| ½Àµµ |
ÀÛµ¿: 10-90% ºñÀÀÃà ºñÀÛµ¿: 5-95% ºñÀÀÃà |
ÀÛµ¿: 10-90% ºñÀÀÃà ºñÀÛµ¿: 5-95% ºñÀÀÃà |
ÀÛµ¿: 10-90% ºñÀÀÃà ºñÀÛµ¿: 5-95% ºñÀÀÃà |
ÀÛµ¿: 5-90% ºñÀÀÃà ºñÀÛµ¿: 5-95% ºñÀÀÃà |
| °íµµ |
ÀÛµ¿: 0-3000m(0-10,000ÇÇÆ®) ºñÀÛµ¿: 0-4,570m(0-15,000ÇÇÆ®) |
ÀÛµ¿: 0-3000m(0-10,000ÇÇÆ®) ºñÀÛµ¿: 0-4,570m(0-15,000ÇÇÆ®) |
ÀÛµ¿: 0-3000m(0-10,000ÇÇÆ®) ºñÀÛµ¿: 0-4,570m(0-15,000ÇÇÆ®) |
ÀÛµ¿: 0-4267m(0-14,000ÇÇÆ®) ºñÀÛµ¿: 0-4877m(0-16,000ÇÇÆ®) |
| ¿ ¹æÃâ |
DC(ÃÖ´ë):4212VA @ 14372Btu/hr AC(ÃÖ´ë): 4651VA @ 15870Btu/hr |
DC(ÃÖ´ë): 2430VA @ 8291Btu/hr AC(ÃÖ´ë): 2790VA @ 15870Btu/hr |
DC(ÃÖ´ë): 1630VA @ 5562Btu/hr Àú¾Ð ¶óÀÎ AC(ÃÖ´ë): 1708VA @ 5828Btu/hr °í¾Ð ¶óÀÎ AC(ÃÖ´ë): 1950VA @ 6654Btu/hr |
DC(ÃÖ´ë): 4212VA @ 14372Btu/hr AC(ÃÖ´ë): 1341VA @ 4575Btu/hr |
| ¼ÒÀ½ |
ÃÖ´ë 70dBa |
ÃÖ´ë 70dBa |
ÃÖ´ë 70dBa |
ÃÖ´ë 70dBa |
| Ãæ°Ý |
ÀÛµ¿(¹Ý Á¤ÇöÆÄ): 21in/s(0.53m/s) ºñÀÛµ¿(»ç´Ù¸®²Ã ÆÞ½º): 20g, 52in/sec(1.32m/sec) |
ÀÛµ¿(¹Ý Á¤ÇöÆÄ): 21in/s(0.53m/s) ºñÀÛµ¿(»ç´Ù¸®²Ã ÆÞ½º): 20g, 52in/sec(1.32m/sec) |
ÀÛµ¿(¹Ý Á¤ÇöÆÄ): 21in/s(0.53m/s) ºñÀÛµ¿(»ç´Ù¸®²Ã ÆÞ½º): 20g, 52in/sec(1.32m/sec) |
ÀÛµ¿(¹Ý Á¤ÇöÆÄ): 5g(11m/sec) ºñÀÛµ¿(»ç´Ù¸®²Ã ÆÞ½º): 15g(11m/sec) |
| Áøµ¿ |
ÀÛµ¿: 3 ~ 500Hz, 0.35grms ºñÀÛµ¿: 3 ~ 500Hz, 1.0grms |
ÀÛµ¿: 3 ~ 500Hz, 0.35grms ºñÀÛµ¿: 3 ~ 500Hz, 1.0grms |
ÀÛµ¿: 3 ~ 500Hz, 0.35grms ºñÀÛµ¿: 3 ~ 500Hz, 1.0grms |
ÀÛµ¿(Á¤ÇöÆÄ): 3 ~ 500Hz @ 0.15gpk(·£´ý): 2.5 ~ 200Hz @ 0.33grms º¸°ü(Á¤ÇöÆÄ): 10 ~ 500Hz @ 0.8gpk(·£´ý): 2.5 ~ 200Hz @ 1.05grms |
| Çϵå¿þ¾î ±¸¼º¿ä¼Ò(±âº» ½Ã½ºÅÛ¿¡ ´ëÇØ) |
DC Àü¿ø °ø±Þ ÀåÄ¡ 4°³ ¶Ç´Â AC Àü¿ø °ø±Þ ÀåÄ¡ 3°³ ȤÀº AC Àü¿ø °ø±Þ ÀåÄ¡ 4°³
¼º´É ¶ó¿ìÅÍ ÇÁ·Î¼¼¼ 1°³
¶óÀÎ Ä«µå 15°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 1°³ ¶Ç´Â ¶óÀÎ Ä«µå 14°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 2°³(1:1 ¸®´ø´ø½Ã)¸¦ Æ÷ÇÔÇÑ ¶óÀÎ Ä«µå ½½·Ô 16°³
½ºÀ§Ä¡ ÆÐºê¸¯ Ä«µå(SFC) 3°³
Ŭ·° ½ºÄÉÁÙ·¯ Ä«µå(CSC) 2°³
¾Ë¶÷ Ä«µå 2°³
¿¡¾î ÇÊÅÍ
ºí·Î¿ö ¾î¼Àºí¸® 2°³
ÄÉÀÌºí °ü¸® Æ®·¹ÀÌ 2°³
±¹°¡º° Àü¿ø ÄÚµå
|
DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³ ¶Ç´Â AC Àü¿ø 2°³
¼º´É ¶ó¿ìÅÍ ÇÁ·Î¼¼¼ 1°³
¶óÀÎ Ä«µå 9°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 1°³ ¶Ç´Â ¶óÀÎ Ä«µå 8°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 2°³(1:1 ¸®´ø´ø½Ã)¸¦ Æ÷ÇÔÇÑ ¶óÀÎ Ä«µå ½½·Ô 10°³
SFC 5°³
CSC 2°³
¾Ë¶÷ Ä«µå 1°³
¿¡¾î ÇÊÅÍ
ºí·Î¿ö ¾î¼Àºí¸® 1°³
ÄÉÀÌºí °ü¸® Æ®·¹ÀÌ 1°³
±¹°¡º° Àü¿ø ÄÚµå
|
DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³ ¶Ç´Â AC Àü¿ø 2°³
¼º´É ¶ó¿ìÅÍ ÇÁ·Î¼¼¼ 1°³
¶óÀÎ Ä«µå 5°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 1°³ ¶Ç´Â ¶óÀÎ Ä«µå 4°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 2°³(1:1 ¸®´ø´ø½Ã)¸¦ Æ÷ÇÔÇÑ ¶óÀÎ Ä«µå ½½·Ô 6°³
SFC 3°³
CSC 2°³
¾Ë¶÷ Ä«µå 1°³
¿¡¾î ÇÊÅÍ
ºí·Î¿ö ¾î¼Àºí¸® 1°³
ÄÉÀÌºí °ü¸® Æ®·¹ÀÌ 1°³
±¹°¡º° Àü¿ø ÄÚµå
|
DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³ ¶Ç´Â AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³
¼º´É ¶ó¿ìÅÍ ÇÁ·Î¼¼¼ 1°³
¶óÀÎ Ä«µå 3°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 1°³ ¶Ç´Â ¶óÀÎ Ä«µå 2°³ ¹× °æ·Î ÇÁ·Î¼¼¼ 2°³(1:1 ¸®´ø´ø½Ã)¸¦ Æ÷ÇÔÇÑ ¶óÀÎ Ä«µå ½½·Ô 4°³
ÅëÇÕ ½ºÀ§Ä¡ ÆÐºê¸¯, Ŭ·° ½ºÄÉÁÙ·¯ ¹× ¾Ë¶÷ Ä«µå 1°³
¿¡¾î ÇÊÅÍ
ºí·Î¿ö ¾î¼Àºí¸® 1°³
ÄÉÀÌºí °ü¸® Æ®·¹ÀÌ 1°³
±¹°¡º° Àü¿ø ÄÚµå
|
| ¼ÒÇÁÆ®¿þ¾î ±¸¼º¿ä¼Ò(±âº» ½Ã½ºÅÛ¿¡ ´ëÇØ) |
Cisco IOS XR ¶Ç´Â Cisco IOS Software ¿î¿µ üÁ¦
ºÐ»ê ÆÐŶ Àü´ÞÀ» À§ÇÑ Cisco Express Forwarding
|
Cisco IOS XR ¶Ç´Â Cisco IOS Software ¿î¿µ üÁ¦
ºÐ»ê ÆÐŶ Àü´ÞÀ» À§ÇÑ Cisco Express Forwarding
|
Cisco IOS XR ¶Ç´Â Cisco IOS Software ¿î¿µ üÁ¦
ºÐ»ê ÆÐŶ Àü´ÞÀ» À§ÇÑ Cisco Express Forwarding
|
Cisco IOS XR ¶Ç´Â Cisco IOS Software ¿î¿µ üÁ¦
ºÐ»ê ÆÐŶ Àü´ÞÀ» À§ÇÑ Cisco Express Forwarding
|
| ȣȯ¼º |
Cisco 12800: 2.5Gbps, 10Gbps, 20Gbps ±â´ÉÀ» Áö¿øÇÏ´Â ¶óÀÎ Ä«µå
Cisco 12400: 2.5Gbps, 10Gbps ±â´ÉÀ» Áö¿øÇÏ´Â ¶óÀÎ Ä«µå
Cisco 12000: 2.5Gbps ±â´ÉÀ» Áö¿øÇÏ´Â ¶óÀÎ Ä«µå
|
| ÇÁ·ÎÅäÄÝ |
IPv4, MPLS, BGPv4(Border Gateway Protocol Version 4), IS-IS(Intermediate System-to-Intermediate System), OSPFv2.0(Open Shortest Path First Version 2.0), RIPv2(Routing Information Protocol Version 2), IGMP(Internet Group Management Protocol), DVMRP(Distance Vector Multicast Routing Protocol) ¹× PIM DX/SX(Protocol Independent Multicast Dense mode/Sparse mode) |
| ¿¬°á |
POS(Packet over SONET/SDH), Ethernet, ATM, copper(DS-3/E3), Channelized(CT3, ChOC-3/CHSTM1, ChOC-12/CHSTM4, ChOC-48/CHSTM16). Cisco XR 12000 ½Ã¸®ÁîÀÇ Æ¯Á¤ ¿¬°á Áö¿ø¿¡ ´ëÇØ ¾Ë¾Æº¸·Á¸é Cisco IOS XR Software ¸±¸®½º ³ëÆ®¸¦ ÂüÁ¶ÇϽʽÿÀ. |
| ¾ÈÀü¼º |
- ½Ã½ºÅÛ ¸®´ø´ø½Ã:
ÆÐºê¸¯ Ä«µå ¸®´ø´ø½Ã 4:1
CSC ¸®´ø´ø½Ã 1:1
Àü¿ø °ø±Þ ÀåÄ¡ ¸®´ø´ø½Ã(DCÀÇ °æ¿ì 1:1, AC´Â ·Îµå ¹ë·±½Ì)
ºí·¯¿ö ¸®´ø´ø½Ã 1:1
°æ·Î ÇÁ·Î¼¼¼ 1:1
¾Ë¶÷ Ä«µå ¸®´ø´ø½Ã 1:1
¶óÀÎ Ä«µå¸¦ ÅëÇÑ µà¾ó Ȩ ÁöÁ¤
APS(Automatic Protection Switching) ASIC Áö¿ø
- MTBF(Æò±Õ Àå¾Ö º¹±¸ ½Ã°£):
CSC = 240,078½Ã°£
SFC = 276,062T½Ã°£
|
| °ü¸® ÀÎÅÍÆäÀ̽º |
Cisco XR 12000 ¹× Cisco 12000 ½Ã¸®Áî ¼º´É °æ·Î ÇÁ·Î¼¼¼¿¡¼´Â 2°³ÀÇ Á÷·Ä Æ÷Æ®(ÄÜ¼Ö ¹× º¸Á¶ Æ÷Æ®)¿Í 1°³ÀÇ 10/100 ÀÌ´õ³Ý Æ÷Æ®¸¦ Áö¿øÇÕ´Ï´Ù. |
| Ç¥½Ã ÀåÄ¡ ¹× ÀÎÅÍÆäÀ̽º |
½Ã½ºÅÛ ¾Ë¶÷ º¸µå¿¡ ¿À·ù Á¶°ÇÀÌ ¹ß»ýÇÑ °æ¿ì ¶Ç´Â CSC, SFC ¹× OnÀÇ »óŰ¡ Critical, Major, MinorÀÎ °æ¿ì, ½Ã°¢Àû ¾Ë¶÷ Ä«µå¸¦ Ç¥½ÃÇÕ´Ï´Ù. |
| ±ÔÁ¤ Áؼö |
- ¾ÈÀü¼º:
UL 1950
CSA-22.2 No. 950
EN60950
IEC 60950 CB Scheme
ACA TS001
AS/NZS 3260
EN60825\IEC60825 ·¹ÀÌÀú ¾ÈÀü
¹Ì±¹ ¿¬¹æ FDA ÄÚµå ·¹ÀÌÀú ¾ÈÀü
- ÀüÀڱ⠱ÔÁ¤ Áؼö(¹æÃâ):
FCC Class A
ICES-003 Class A
EN55022 Class B(ÃÖ´ë 1GHz)
VCCI Class B(ÃÖ´ë 1GHz)
AS/NZS 3548 Class B
MSZEN55022 Class A
CISPR 22 Class B(ÃÖ´ë 1GHz)
BSMI Class A
- ÀüÀÚÆÄ ³»¼º:
IEC-1000-4-2 ESD(8kV ÄÁÅÃ, 15kV ¿¡¾î)
IEC-1000-4-3 Radiated Immunity(10V/m)
IEC-1000-4-4 EFT(2kV Àü¿ø Æ÷Æ®, 1kV ½ÅÈ£ Æ÷Æ®)
IEC-1000-4-5 Surge AC Æ÷Æ®(4kV CM, 2kV DM)
IEC-1000-4-5 Surge ½ÅÈ£ Æ÷Æ®(2kV CM, 1kV DM)
IEC-1000-4-5 Surge DC Æ÷Æ®(0.5kV CM, 0.5kV DM)
IEC-1000-4-6 ÀúÁ֯ļö Àüµµ ³»¼º(10V)
IEC-1000-4-11 ¼ø½Ã Àü¾Ð ÀúÇÏ(Voltage Dip/Sag)
IEC-1000-3-2 Power line Harmonics
|
| ½ÂÀÎ ±â°ü |
- NEBS(Network Equipment Building Standards)
NEBS ±Ô°Ý Áؼö ¼³°è
- ETSI
EN300386
ETS 300132-2
|
|
ÃÖ¾Ç Á¶°Ç(ÃÖ¾ÇÀÇ ÀÔ·Â Àü¾Ð µî)¿¡¼ ¾òÀº ÃÖ´ë ½Ã½ºÅÛ Àü·Â ¼öÄ¡°¡ °í°´ÀÇ ÀϹÝÀûÀÎ ÇØ´ç ±¸¼º Á¶°ÇÇÏ¿¡¼ ¾ò°Ô µÉ °á°ú¸¦ ¹Ýµå½Ã ¹Ý¿µÇÏ´Â °ÍÀº ¾Æ´Õ´Ï´Ù.
°¢ Àü¿ø °ø±Þ ÀåÄ¡ ¸ðµâ¿ë
¿Ïº®ÇÑ ¸®´ø´ø½Ã Àü¿ø ±¸¼º¿¡¼, Àü¿ø ¿£Æ®¸® ¸ðµâ A1 ¹× B1Àº ½Ã½ºÅÛ ·Îµå ±¸¿ª 1(»óºÎ ºí·Î¿ö ¸ðµâ ¹× »óºÎ Ä«µå ÄÉÀÌÁö)À» À§ÇÑ ¸®´ø´ø½ÃÇü Àü¿øÀ» Á¦°øÇÕ´Ï´Ù. ¸ðµâ A2¿Í B2´Â ½Ã½ºÅÛ ·Îµå ±¸¿ª 2(½ºÀ§Ä¡ ÆÐºê¸¯ Ä«µå ÄÉÀÌÁö, ÇϺΠīµå ÄÉÀÌÁö ¹× ÇϺΠºí·Î¿ö ¸ðµâ)¸¦ À§ÇÑ ¸®´ø´ø½ÃÇü Àü¿øÀ» Á¦°øÇÕ´Ï´Ù.
grms´Â °¡¼ÓµµÀÇ Á¦°ö±Ù °ªÀ̰í, gpk´Â ÃÖ°í °¡¼ÓµµÀÔ´Ï´Ù.
|
|
Ç¥ 2. ÁÖ¹® Á¤º¸
|
| Á¦Ç° »ç¾ç |
ºÎǰ ¹øÈ£ |
| Cisco 12000 16½½·Ô ½Ã½ºÅÛ |
| Cisco XR 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 3°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12416/320-AC |
| Cisco XR 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12416/320-AC4 |
| Cisco XR 12000 16½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12416/320-DC |
| Âü°í: ÇÑÁ¤ ÁÖ¹®¿¡ ÇÑÇØ IOS XR Release 3.2¿¡¼ Cisco XR 12000 16½½·Ô ¼¨½Ã¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Áö¿øÀÌ ÇÊ¿äÇÑ °æ¿ì ½Ã½ºÄÚ ¿µ¾÷ ´ã´çÀÚ¿¡°Ô ¹®ÀÇÇϽʽÿÀ. |
| Cisco 12000 16½½·Ô ½Ã½ºÅÛ |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 3°³, 80Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/80-AC-8R |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 3°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/320-AC |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 3°³, 1280Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12816/1280-AC3 |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 80Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/80-AC4-8R |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/320-AC4 |
| Cisco 12000 16½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 1280Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12816/1280-AC4 |
| Cisco 12000 16½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 80Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/80-DC-8R |
| Cisco 12000 16½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 320Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR16/320-DC |
| Cisco 12000 16½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 4°³, 1280Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 2°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12816/1280-DC |
| Cisco 12000 10½½·Ô ½Ã½ºÅÛ |
| Cisco XR 12000 10½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 200Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12410/200-AC |
| Cisco XR 12000 10½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 200Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12410/200-DC |
| Âü°í: ÇÑÁ¤ ÁÖ¹®¿¡ ÇÑÇØ IOS XR Release 3.2¿¡¼ Cisco XR 12000 10½½·Ô ¼¨½Ã¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Áö¿øÀÌ ÇÊ¿äÇÑ °æ¿ì ½Ã½ºÄÚ ¿µ¾÷ ´ã´çÀÚ¿¡°Ô ¹®ÀÇÇϽʽÿÀ. |
| Cisco 12000 10½½·Ô ½Ã½ºÅÛ |
| Cisco 12000 10½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 50Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12010-AC |
| Cisco 12000 10½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 50Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12010-DC |
| Cisco 12000 10½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 200Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR10/200-AC |
| Cisco 12000 10½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 200Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR10/200-DC |
| Cisco 12000 10½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 800Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12810/800-AC |
| Cisco 12000 10½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 800Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 5°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12810/800-DC |
| Cisco 12000 6½½·Ô ½Ã½ºÅÛ |
| Cisco XR 12000 6½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(CSC 1°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12406/120-AC |
| Cisco XR 12000 6½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(CSC 1°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12406/120-DC |
| Âü°í: ÇÑÁ¤ ÁÖ¹®¿¡ ÇÑÇØ IOS XR Release 3.2¿¡¼ Cisco XR 12000 6½½·Ô ¼¨½Ã¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Áö¿øÀÌ ÇÊ¿äÇÑ °æ¿ì ½Ã½ºÄÚ ¿µ¾÷ ´ã´çÀÚ¿¡°Ô ¹®ÀÇÇϽʽÿÀ. |
| Cisco 12000 6½½·Ô ½Ã½ºÅÛ |
| Cisco 12000 6½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 30Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12006-AC |
| Cisco 12000 6½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 2°³, 30Gbps ÆÐºê¸¯(CSC 2°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
12006-DC |
| Cisco 12000 6½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(CSC 1°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR6/120-AC |
| Cisco 12000 6½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(CSC 1°³¿Í SFC Ä«µå 3°³), ºí·Î¿ö 1°³, ¾Ë¶÷ 2°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR6/120-DC |
| Cisco 12000 4½½·Ô ½Ã½ºÅÛ |
| Cisco XR 12000 4½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(ÅëÇÕ ½ºÀ§Ä¡ ÆÐºê¸¯, Ŭ·° ½ºÄÉÁÙ·¯ ¹× ¾Ë¶÷ Ä«µå), ºí·Î¿ö 1°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12404/80-AC |
| Cisco XR 12000 4½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(ÅëÇÕ ½ºÀ§Ä¡ ÆÐºê¸¯, Ŭ·° ½ºÄÉÁÙ·¯ ¹× ¾Ë¶÷ Ä«µå), ºí·Î¿ö 1°³ ¹× PRP-2 1°³ Æ÷ÇÔ) |
XR-12404/80-DC |
| Âü°í: ÇÑÁ¤ ÁÖ¹®¿¡ ÇÑÇØ IOS XR Release 3.2¿¡¼ Cisco XR 12000 4½½·Ô ¼¨½Ã¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. Áö¿øÀÌ ÇÊ¿äÇÑ °æ¿ì ½Ã½ºÄÚ ¿µ¾÷ ´ã´çÀÚ¿¡°Ô ¹®ÀÇÇϽʽÿÀ. |
| Cisco 12000 4½½·Ô ½Ã½ºÅÛ |
| Cisco 12000 4½½·Ô ¼¨½Ã(AC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(ÅëÇÕ ½ºÀ§Ä¡ ÆÐºê¸¯, Ŭ·° ½ºÄÉÁÙ·¯ ¹× ¾Ë¶÷ Ä«µå), ºí·Î¿ö 1°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR4/80-AC |
| Cisco 12000 4½½·Ô ¼¨½Ã(DC Àü¿ø °ø±Þ ÀåÄ¡ 1°³, 120Gbps ÆÐºê¸¯(ÅëÇÕ ½ºÀ§Ä¡ ÆÐºê¸¯, Ŭ·° ½ºÄÉÁÙ·¯ ¹× ¾Ë¶÷ Ä«µå), ºí·Î¿ö 1°³ ¹× PRP-1 1°³ Æ÷ÇÔ) |
GSR4/80-DC |
|
|
| ½Ã½ºÄÚ ½Ã½ºÅÛÁî´Â ¼ºñ½º °ø±Þ¾÷ü¸¦ À§ÇÑ ´Ù¾çÇÑ Áö¿ø ¹× Á¦°ø¿¡ ÀÖ¾î ³ôÀº °í°´ ¸¸Á·µµ µî±ÞÀ» ¹Þ¾Ò½À´Ï´Ù. ½Ã½ºÄÚ´Â ½ÃÀå Ãâ½Ã ½Ã±â ´ÜÃà, ³×Æ®¿öÅ© °¡¿ë¼º ±Ø´ëÈ, °í°´ ¸¸Á· ¹× º¸À¯À² °³¼± µî ¼ºñ½º Á¦°ø¾÷üÀÇ ¸ðµç ¼ºñ½º ¸ñÇ¥¸¦ ÃÖ¼±À» ´ÙÇØ ÃæÁ·½ÃÄÑ µå¸³´Ï´Ù. |
|
|
Cisco¿¡ ¹®ÀÇÇϼ¼¿ä
- ÀϹݹ®ÀÇ 080-377-0880
Á¦Ç°/±¸¸Å 080-808-8082
|