Configuring T1/E1 Interfaces
Configuration Tasks
Limitations
Required Configuration Tasks
Setting the Card Type
Configuring the Controller
Verifying Controller Configuration
Optional Configurations
Configuring Framing
Saving the Configuration
Troubleshooting E1 and T1 Controllers
Setting Loopbacks
Run Bit Error Rate Test
Monitor and Maintain the T1/E1 Interface Module
Configuring CEM
Configuring a CEM Group
Using CEM Classes
Configuring CEM Parameters
Configuring Payload Size (Optional)
Setting the Dejitter Buffer Size
Setting an Idle Pattern (Optional)
Enabling Dummy Mode
Setting a Dummy Pattern
Shutting Down a CEM Channel
Configuration Examples
Framing and Encapsulation Configuration Example
CRC Configuration Example
Facility Data Link Configuration Example
Invert Data on the T1/E1 Interface Example
CEM Configuration Example
Configuring T1/E1 Interfaces
This chapter provides information about configuring the T1/E1 interface module on the Cisco ME 3600X 24CX Series Switch. It includes the following sections:
•
Configuration Tasks
•
Configuration Examples
For information about managing your system images and configuration files, refer to the Cisco IOS Configuration Fundamentals Configuration Guide and Cisco IOS Configuration Fundamentals Command Reference publications.
For more information about the commands used in this chapter, refer to the Cisco IOS Command Reference publication for your Cisco IOS software release.
For more information, see the Related Publications.
Configuration Tasks
This section describes how to configure the T1/E1 interface module for the Cisco ME 3600X 24CX Series Switch and includes information about verifying the configuration.
It includes the following topics:
•
Required Configuration Tasks
•
Optional Configurations
•
Saving the Configuration
Limitations
This section describes the software limitations that apply when configuring the T1/E1 interface module on the Cisco ME 3600X 24CX Series Switch.
The following features are not currently supported on the T1/E1 interface module:
•
Serial interfaces—The Cisco ME 3600X 24CX Series Switch does not currently support serial interfaces or features applied to serial interfaces. We recommend that you use a configuration with CEM as a workaround.
•
Channel groups—The Cisco ME 3600X 24CX Series Switch does not currently support channel-groups or features applied to channel-groups. We recommend that you use a configuration with CEM as a workaround.
•
Supported BERT patterns—Currently only the 2^11, 2^15, 2^20-O153, and 2^20-QRSS patterns are supported.
Required Configuration Tasks
This section lists the required configuration steps to configure the T1/E1 interface module. Some of the required configuration commands implement default values that might be appropriate for your network. If the default value is correct for your network, then you do not need to configure the command.
•
Setting the Card Type
•
Configuring the Controller
•
Verifying Controller Configuration
•
Optional Configurations
Setting the Card Type
The interface module is not functional until the card type is set. Information about the interface module is not indicated in the output of any show commands until the card type has been set. There is no default card type.
Note
Mixing of interface types is not supported. All ports on the interface module must be of the same type.
To set the card type for the T1/E1 interface module, complete these steps:
| |
Command
|
Purpose
|
Step 1
|
Router# configure terminal
|
Enters global configuration mode.
|
Step 2
|
Router(config)# card type {e1 | t1} 0 1
|
Sets the serial mode for the interface module:
• t1—Specifies T1 connectivity of 1.536 Mbps. B8ZS is the default line code for T1.
• e1—Specifies a wide-area digital transmission scheme used predominantly in Europe that carries data at a rate of 1.984 Mbps in framed mode and 2.048 Mbps in unframed E1 mode.
• 0—Specifies the card.
• 1—Specifies the card bay number.
|
Step 3
|
Router(config)# exit
|
Exits configuration mode and returns to the EXEC command interpreter prompt.
|
Configuring the Controller
To create the interfaces for the T1/E1 interface module, complete these steps:
| |
Command
|
Purpose
|
Step 1
|
Router(config)# controller {t1 | e1} card/number
|
Selects the controller to configure and enters controller configuration mode.
• t1—Specifies the T1 controller.
• e1—Specifies the E1 controller.
• card/number—Specifies the location of the interface.
Note The card numbers supported are 0 or 1. The number range for T1 is 0 to 15. The number range for E1 is 0 to 31.
|
Step 2
|
Router(config-controller)# clock source {internal | line}
|
Sets the clock source.
Note The clock source is set to internal if the opposite end of the connection is set to line and the clock source is set to line if the opposite end of the connection is set to internal.
• internal—Specifies that the internal clock source is used.
• line—Specifies that the network clock source is used. This is the default for T1 and E1.
|
Step 3
|
Router(config-controller)# linecode {ami | b8zs | hdb3}
|
Selects the linecode type.
• ami—Specifies Alternate Mark Inversion (AMI) as the linecode type. Valid for T1 and E1 controllers.
• b8zs—Specifies binary 8-zero substitution (B8ZS) as the linecode type. Valid for T1 controller only. This is the default for T1 lines.
• hdb3—Specifies high-density binary 3 (HDB3) as the linecode type. Valid for E1 controller only. This is the default for E1 lines.
|
Step 4
|
For T1 Controllers:
Router(config-controller)# framing {sf | esf}
For E1 Controllers:
Router(config-controller)# framing {crc4 | no-crc4}
|
Selects the framing type.
• sf—Specifies Super Frame as the T1 frame type.
• esf—Specifies Extended Super Frame as the T1 frame type. This is the default for E1.
• crc4—Specifies CRC4 as the E1 frame type. This is the default for E1.
• no-crc4—Specifies no CRC4 as the E1 frame type.
|
Step 5
|
cablelength {long | short}
Example:
Router(config-controller)#
cablelength long
|
To fine-tune the pulse of a signal at the receiver for an E1 cable on a Cisco ME3600X-24CX-M, use the cablelength command in controller configuration mode.
|
Step 6
|
exit
Example:
Router(config)# exit
|
Exits configuration mode and returns to the EXEC command interpreter prompt.
|
Verifying Controller Configuration
Use the show controllers command to verify the controller configuration:
Router# show controllers e1 0/11
Applique type is Channelized E1 - balanced
Cablelength is long gain36 0db
Soaking time: 3, Clearance time: 10
AIS State:Clear LOS State:Clear LOF State:Clear
Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
Data in current interval (230 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
0 Near-end path failures, 0 Far-end path failures, 0 SEF/AIS Secs
Total Data (last 24 hours)
136 Line Code Violations, 63 Path Code Violations,
0 Slip Secs, 6 Fr Loss Secs, 4 Line Err Secs, 0 Degraded Mins,
7 Errored Secs, 1 Bursty Err Secs, 6 Severely Err Secs, 458 Unavail Secs
2 Near-end path failures, 0 Far-end path failures, 0 SEF/AIS Secs
Optional Configurations
There are several standard, but optional, configurations that might be necessary to complete the configuration of your Ethernet interface module.
•
Configuring Framing
•
Saving the Configuration
Configuring Framing
Framing is used to synchronize data transmission on the line. Framing allows the hardware to determine when each packet starts and ends. To configure framing, use the following commands.
Command
|
Purpose
|
Router# configure terminal
|
Enters global configuration mode.
|
Router(config)# controller {t1 | e1} card/number
|
Selects the controller to configure.
• t1—Specifies the T1 controller.
• e1—Specifies the E1 controller.
• card/number—Specifies the location of the controller.
Note The card is always 0.
|
For T1 controllers
Router(config-controller)# framing {sf | esf}
For E1 controllers
Router(config-controller)# framing {crc4 | no-crc4}
|
Set the framing on the interface.
• sf—Specifies Super Frame as the T1 frame type.
• esf—Specifies Extended Super Frame as the T1 frame type. This is the default. for T1.
• crc4—Specifies CRC4 frame as the E1 frame type. This is the default for E1.
• no-crc4—Specifies no CRC4 as the E1 frame type.
|
Verifying Framing Configuration
Use the show controllers command to verify the framing configuration:
Router# show controllers t1 0/11
Applique type is Channelized T1 - balanced
Cablelength is long gain36 0db
Soaking time: 3, Clearance time: 10
AIS State:Clear LOS State:Clear LOF State:Clear
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (740 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
0 Near-end path failures, 0 Far-end path failures, 0 SEF/AIS Secs
Total Data (last 24 hours)
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
0 Near-end path failures, 0 Far-end path failures, 0 SEF/AIS Secs
Saving the Configuration
To save your running configuration to nonvolatile random-access memory (NVRAM), use the following command in privileged EXEC configuration mode:
Command
|
Purpose
|
Router# copy running-config startup-config
|
Writes the new configuration to NVRAM.
|
For information about managing your system images and configuration files, refer to the Cisco IOS Configuration Fundamentals Configuration Guide and Cisco IOS Configuration Fundamentals Command Reference publications.
Troubleshooting E1 and T1 Controllers
You can use the following methods to troubleshoot the E1 and T1 controllers using Cisco IOS software:
•
Setting Loopbacks
•
Run Bit Error Rate Test
Setting Loopbacks
The following sections describe how to set loopbacks:
•
Setting a Loopback on the E1 Controller
•
Setting a Loopback on the T1 Controller
Setting a Loopback on the E1 Controller
To set a loopback on the E1 controller, perform the first task followed by any of the following tasks beginning in global configuration mode:
Task
|
Command
|
Select the E1 controller and enter controller configuration mode.
|
controller e1 card/number
Note The card is always 0.
|
Set a diagnostic loopback on the E1 line.
|
loopback diag
|
Set a network payload loopback on the E1 line.
|
loopback network {line | payload}
|
Exit configuration mode when you have finished configuring the controller.
|
end
|
Setting a Loopback on the T1 Controller
To set a loopback on the T1 controller, perform the first task followed by any of the following tasks beginning in global configuration mode:
Task
|
Command
|
Select the T1 controller and enter controller configuration mode.
|
controller t1 card/number
Note The card is always 0.
|
Set a diagnostic loopback on the T1 line.
|
loopback diag
|
Set a local loopback on the T1 line. You can select to loopback the line or the payload.
|
loopback local {line | payload}
|
Set a remote loopback on the T1 line. This loopback setting will loopback the far end at line or payload, using IBOC (in band bit-orientated code) or the ESF loopback codes to communicate the request to the far end.
|
loopback remote iboc
|
Exit configuration mode when you have finished configuring the controller.
|
end
|
Note
To remove a loopback, use the no loopback command.
Table 3-1 Loopback Descriptions
Loopback
|
Description
|
loopback diag
|
Loops the outgoing transmit signal back to the receive signal. This is done using the diagnostic loopback feature in the interface module's PMC framer. The interface module transmits AIS in this mode. Set the clock source command to internal for this loopback mode.
|
loopback local
|
Loops the incoming receive signal back out the transmitter. You can specify whether to use the line or payload.
|
local line
|
The incoming signal is looped back in the interface module using the framer's line loopback mode. The framer does not re-clock or re-frame the incoming data. All incoming data is receive by the interface module's driver.
|
local payload
|
The incoming signal is looped back in the interface module using the framer's payload loopback mode. The framer re-clocks and re-frames the incoming data before sending it back out to the network. When in payload loopback, an all 1s data pattern is received by the local HDLC receiver, and the clock source is automatically set to line (overriding the clock source command). When the payload loopback is ended, the clock source returns to the last setting selected by the clock source command.
|
loopback remote iboc
|
Attempts to set the far-end T1 interface into line loopback. This command sends an in-band bit-oriented code to the far-end to cause it to go into line loopback. This command is available when using ESF or SF framing mode.
|
network line
|
The incoming signal is looped back in the interface module using the framer's line loopback mode. The framer does not re-clock or re-frame the incoming data. All incoming data is received by the interface module's driver.
|
network payload
|
The incoming signal is looped back in the interface module using the framer's payload loopback mode. The framer re-clocks and re-frames the incoming data before sending it back out to the network. When in payload loopback, an all 1s data pattern is received by the local HDLC receiver, and the clock source is automatically set to line (overriding the clock source command). When the payload loopback is ended, the clock source returns to the last setting selected by the clock source command.
|
Run Bit Error Rate Test
Bit error rate testing (BERT) is supported on each of the E1 or T1 links. The BERT testing is done only over a framed E1 or T1 signal and can be run only on one port at a time.
The interface modules contain onboard BERT circuitry. With this, the interface module software can send and detect a programmable pattern that is compliant with CCITT/ITU O.151, O.152, and O.153 pseudo-random and repetitive test patterns. BERTs allow you to test cables and signal problems in the field.
When running a BER test, your system expects to receive the same pattern that it is transmitting. To help ensure this, two common options are available:
•
Use a loopback somewhere in the link or network
•
Configure remote testing equipment to transmit the same BER test pattern at the same time
To run a BERT on an E1 or T1 controller, perform the following optional tasks beginning in global configuration mode:
Task
|
Command
|
Select the E1 or T1 controller and enter controller configuration mode.
|
controller {e1 | t1} card/number
Note The card is always 0.
|
Specify the BERT pattern for the E1 or T1 line and the duration of the test in minutes (1 to 1440 minutes).
Note 2^23 and 2^20-O153 patterns are not supported.
|
bert pattern {0s | 1s | 2^11 | 2^15 | 2^20-O153 | 2^20-QRSS | 2^23 | alt-0-1} interval minutes
|
Exit configuration mode when you have finished configuring the controller.
|
end
|
View the BERT results.
|
show controllers {e1 | t1} card/number
|
The following keywords list different BERT keywords and their descriptions.
Caution 
Currently 2^23, and 2^20-O153 patterns are not supported.
Table 3-2 BERT Pattern Descriptions
Keyword
|
Description
|
0s
|
Repeating pattern of zeros (...000...).
|
1s
|
Repeating pattern of ones (...111...).
|
2^11
|
Pseudo-random test pattern that is 2,048 bits in length.
|
2^15
|
Pseudo-random O.151 test pattern that is 32,768 bits in length.
|
2^20-O153
|
Pseudo-random O.153 test pattern that is 1,048,575 bits in length.
|
2^20-QRSS
|
Pseudo-random QRSS O.151 test pattern that is 1,048,575 bits in length.
|
2^23
|
Pseudo-random 0.151 test pattern that is 8,388,607 bits in length.
|
alt-0-1
|
Repeating alternating pattern of zeros and ones (...01010...).
|
Both the total number of error bits received and the total number of bits received are available for analysis. You can select the testing period from 1 minute to 24 hours, and you can also retrieve the error statistics anytime during the BER test.
Note
To terminate a BER test during the specified test period, use the no bert command.
You can view the results of a BER test at the following times:
•
After you terminate the test using the no bert command
•
After the test runs completely
•
Anytime during the test (in real time)
Monitor and Maintain the T1/E1 Interface Module
After configuring the new interface, you can monitor the status and maintain the interface module by using show commands. To display the status of any interface, complete any of the following tasks in EXEC mode:
Task
|
Command
|
Display the status of the E1 or T1 controller.
|
show controllers {e1 | t1} [card/number] [brief]
|
Configuring CEM
This section provides information about how to configure CEM. CEM provides a bridge between a time-division multiplexing (TDM) network and a packet network, such as Multiprotocol Label Switching (MPLS). The router encapsulates the TDM data in the MPLS packets and sends the data over a CEM pseudowire to the remote provider edge (PE) router. Thus, function as a physical communication link across the packet network.
The following sections describe how to configure CEM:
•
Configuring a CEM Group
•
Using CEM Classes
•
Configuring CEM Parameters
Note
CEM is used as an element in configuring pseudowires including Structure-Agnostic TDM over Packet (SAToP) and Circuit Emulation Service over Packet-Switched Network (CESoPSN). For more information about configuring pseudowires, see Chapter 6 "Configuring Pseudowire."
Configuring a CEM Group
The following section describes how to configure a CEM group on the Cisco ME 3600X 24CX Series Switch.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
controller {t1 | e1} card/number
4.
cem-group group-number {unframed | timeslots timeslot}
5.
end
| |
Command
|
Purpose
|
Step 1
|
enable
|
Enables privileged EXEC mode.
• Enter your password if prompted.
|
Step 2
|
configure terminal
|
Enters global configuration mode.
|
Step 3
|
controller {t1 | e1} card/number
|
Enters controller configuration mode.
·Use the card, number arguments to specify the card number and bay number to be configured.
Note The card number is always 0.
|
Step 4
|
cem-group group-number {unframed |
timeslots timeslot}
|
Creates a circuit emulation channel from one or more time slots of a T1 or E1 line.
• The group-number keyword identifies the channel number to be used for this channel. For T1 ports, the range is 0 to 23. For E1 ports, the range is 0 to 30.
• Use the unframed keyword to specify that a single CEM channel is being created including all time slots and the framing structure of the line.
• Use the timeslots keyword and the timeslot argument to specify the time slots to be included in the CEM channel. The list of time slots may include commas and hyphens with no spaces between the numbers.
Note The speed keyword is not currently supported.
|
Step 5
|
end
|
Exits controller configuration mode and returns to privileged EXEC mode.
|
Using CEM Classes
A CEM class allows you to create a single configuration template for multiple CEM pseudowires. Follow these steps to configure a CEM class:
Note
The CEM parameters at the local and remote ends of a CEM circuit must match; otherwise, the pseudowire between the local and remote PE routers will not come up.
Note
You cannot apply a CEM class to other pseudowire types such as ATM over MPLS.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
class cem classname
4.
payload-size size
5.
dejitter-buffer size
6.
idle-pattern {pattern | length pattern1 [pattern2]}
7.
exit
8.
interface cem card/number
9.
no ip address
10.
cem card/number
11.
cem group-number
12.
xconnect peer-ip-address vc-id {encapsulation {l2tpv3 [manual] | mpls [manual]} | pw-class pw-class-name} [pw-class pw-class-name] [sequencing {transmit | receive | both}]
13.
exit
14.
exit
| |
Command
|
Purpose
|
Step 1
|
enable
|
Enables privileged EXEC mode.
• Enter your password if prompted.
|
Step 2
|
configure terminal
|
Enters global configuration mode.
|
Step 3
|
Router(config)# class cem
mycemclass
|
Creates a new CEM class
|
Step 4
|
payload-size size
dejitter-buffer size
idle-pattern {pattern | length
pattern1 [pattern2]}
|
Enter the configuration commands common to the CEM class. This example specifies a sample rate, payload size, dejitter buffer, and idle pattern.
|
Step 5
|
Router(config-cem-class)# exit
|
Returns to the config prompt.
|
Step 6
|
Router(config)# interface cem 0/1
Router(config-if)# no ip address
Router(config-if)# cem 0
Router(config-if-cem)# xconnect
10.10.10.10 200 encapsulation mpls
|
Configure the CEM interface that you want to use for the new CEM class.
Note The use of the xconnect command can vary depending on the type of pseudowire you are configuring.
|
Step 7
|
Router(config-if-cem)# exit
Router(config-if)#
|
Exits the CEM interface.
|
Step 8
|
exit
|
Exits configuration mode.
|
Configuring CEM Parameters
The following sections describe the parameters you can configure for CEM circuits.
•
Configuring Payload Size (Optional)
•
Setting the Dejitter Buffer Size
•
Setting an Idle Pattern (Optional)
•
Enabling Dummy Mode
•
Setting a Dummy Pattern
•
Shutting Down a CEM Channel
Note
The CEM parameters at the local and remote ends of a CEM circuit must match; otherwise, the pseudowire between the local and remote PE routers will not come up.
Configuring Payload Size (Optional)
To specify the number of bytes encapsulated into a single IP packet, use the pay-load size command. The size argument specifies the number of bytes in the payload of each packet. The range is from 32 to 1312 bytes.
Default payload sizes for an unstructured CEM channel are as follows:
•
E1 = 256 bytes
•
T1 = 192 bytes
•
DS0 = 32 bytes
Default payload sizes for a structured CEM channel depend on the number of time slots that constitute the channel. Payload size (L in bytes), number of time slots (N), and packetization delay (D in milliseconds) have the following relationship: L = 8*N*D. The default payload size is selected in such a way that the packetization delay is always 1 millisecond. For example, a structured CEM channel of 16xDS0 has a default payload size of 128 bytes.
The payload size must be an integer of the multiple of the number of time slots for structured CEM channels.
Setting the Dejitter Buffer Size
To specify the size of the dejitter buffer used to compensate for the network filter, use the dejitter-buffer size command. The configured dejitter buffer size is converted from milliseconds to packets and rounded up to the next integral number of packets. Use the size argument to specify the size of the buffer, in milliseconds. The range is from 1 to 500 ms; the default is 5 ms.
Setting an Idle Pattern (Optional)
To specify an idle pattern, use the [no] idle-pattern pattern1 command. The payload of each lost CESoPSN data packet must be replaced with the equivalent amount of the replacement data. The range for pattern is from 0x0 to 0xFF; the default idle pattern is 0xFF.
Enabling Dummy Mode
Dummy mode enables a bit pattern for filling in for lost or corrupted frames. To enable dummy mode, use the dummy-mode [last-frame | user-defined] command. The default is last-frame. The following is an example:
Router(config-cem)# dummy-mode last-frame
Setting a Dummy Pattern
If dummy mode is set to user-defined, you can use the dummy-pattern pattern command to configure the dummy pattern. The range for pattern is from 0x0 to 0xFF. The default dummy pattern is 0xFF. The following is an example:
Router(config-cem)# dummy-pattern 0x55
Shutting Down a CEM Channel
To shut down a CEM channel, use the shutdown command in CEM configuration mode. The shutdown command is supported only under CEM mode and not under the CEM class.
Configuration Examples
This section includes the following configuration examples:
•
Framing and Encapsulation Configuration Example
•
CRC Configuration Example
•
Facility Data Link Configuration Example
•
Invert Data on the T1/E1 Interface Example
Framing and Encapsulation Configuration Example
The following example sets the framing and encapsulation for the controller and interface:
! Specify the controller and enter controller configuration mode
Router(config)# controller t1 0/1
! Specify the framing method
Router(config-controller)# framing esf
! Exit controller configuration mode and return to global configuration mode
Router(config-controller)# exit
! Specify the interface and enter interface configuration mode
Router(config)# interface serial 0/1
! Specify the encapsulation protocol
Router(config-if)# encapsulation ppp
! Exit interface configuration mode
! Exit global configuration mode
CRC Configuration Example
The following example sets the CRC size for the interface:
! Specify the interface and enter interface configuration mode
Router(config)# interface serial 0/1
Router(config-if)# crc 32
! Exit interface configuration mode and return to global configuration mode
! Exit global configuration mode
Facility Data Link Configuration Example
The following example configures Facility Data Link:
! Specify the controller and enter controller configuration mode
Router(config)# controller t1 0/1
! Specify the FDL specification
Router(config-controller)# fdl ansi
! Exit controller configuration mode and return to global configuration mode
Router(config-controller)# exit
! Exit global configuration mode
Invert Data on the T1/E1 Interface Example
The following example inverts the data on the serial interface:
! Enter global configuration mode
Router# configure terminal
! Specify the serial interface and enter interface configuration mode
Router(config)# interface serial 0/1
Router(config-if)# invert data
! Exit interface configuration mode and return to global configuration mode
! Exit global configuration mode
CEM Configuration Example
The following example shows how to add a T1 interface to a CEM group as a part of a SAToP pseudowire configuration. For more information about how to configure pseudowires, see Chapter 6 "Configuring Pseudowire."
Note
This section displays a partial configuration intended to demonstrate a specific feature.
xconnect 18.1.1.1 1000 encapsulation mpls