Cisco MDS 9000 NX-OS and SAN-OS Software

Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(3a)

 Feedback

Table Of Contents

Cisco MDS 9000 Family Release Notes
for Cisco MDS SAN-OS Release 3.2(3a)

Contents

Introduction

Components Supported

Software Download Process

Determining the Software Version

Downloading Software

Selecting the Correct Software Image for an MDS 9100 Series Switch

Selecting the Correct Software Image for an MDS 9200 Series Switch

Selecting the Correct Software Image for an MDS 9500 Series Switch

Migrating from Supervisor-1 Modules to Supervisor-2 Modules

Configuring Generation 2 Switching Modules

Upgrading Your Cisco MDS SAN-OS Software Image

Performing a Nondisruptive Software Upgrade on Generation 1 Modules

Upgrading Your Version of Cisco Fabric Manager

General Upgrading Guidelines

FICON Supported Releases and Upgrade Paths

Upgrading with IVR Enabled

Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.2(3a)

Upgrading the SSI Image on Your SSM

Upgrading a Switch with Insufficient Space for Two Images on the Bootflash

Upgrading a Cisco MDS 9124 Switch

Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch

Downgrading Your Cisco MDS SAN-OS Software Image

General Downgrading Guidelines

FICON Downgrade Paths

Downgrading the SSI Image on Your SSM

New Features in Cisco MDS SAN-OS Release 3.2(3a)

Limitations and Restrictions

Upgrading to Recover Loss of Performance Manager Data

Maximum Number of Zones Supported in Interop Mode 4

CompactFlash Check Utility

Cisco SME Configuration Limits

Java Web Start

Compatibility of Fabric Manager and Data Mobility Manager

PPRC Not Supported with FCIP Write Acceleration

Using IVR In a Fabric With Mixed Code Versions

Caveats

Resolved Caveats

Open Caveats

Related Documentation

Release Notes

Compatibility Information

Regulatory Compliance and Safety Information

Hardware Installation

Cisco Fabric Manager

Command-Line Interface

Intelligent Storage Networking Services Configuration Guides

Troubleshooting and Reference

Installation and Configuration Note

Obtaining Documentation, Obtaining Support, and Security Guidelines


Cisco MDS 9000 Family Release Notes
for Cisco MDS SAN-OS Release 3.2(3a)


Release Date: February 27, 2008

Part Number: OL-14116-05 S0

This document describes the caveats and limitations for switches in the Cisco MDS 9000 Family. Use Cthis document in conjunction with documents listed in the "Related Documentation" section.


Note Release notes are sometimes updated with new information on restrictions and caveats. Refer to the following website for the most recent version of the Cisco MDS 9000 Family Release Notes: http://www.cisco.com/en/US/products/hw/ps4159/ps4358/prod_release_notes_list.html


Table 1 shows the on-line change history for this document.

Table 1 Online History Change

Revision
Date
Description

A0

02/27/2008

Created release notes.

B0

03/03/2008

Added CompactFlash Check Utility limitation.

C0

03/06/2008

Added DDTS CSCsm75402 and CSCso04862.

D0

04/02/2008

Changed DDTS CSCsk49761 to resolved.

E0

04/04/2008

Added DDTS CSCsm08837 and CSCsm56190.

F0

04/30/2008

Added DDTS CSCso63465.

G0

06/03/2008

Revised General Upgrading Guidelines.

H0

06/19/2008

Updated Installing Fabric Manager on Windows.

I0

07/09/2008

Added Upgrading to Recover Loss of Performance Manager Data to Limitations and Restrictions section.

J0

09/17/2008

Added DDTS CSCsl12611.

K0

11/13/2008

Added the "Performing a Nondisruptive Software Upgrade on Generation 1 Modules" section.

L0

11/18/2008

Added DDTS CSCso72230.

Removed DDTS CSCsk90998.

M0

04/14/2009

Updated DDTS CSCsk49634.

N0

04/29/2009

Added the "FICON Supported Releases and Upgrade Paths" section.

Revised the "FICON Downgrade Paths" section.

Added the "Compatibility of Fabric Manager and Data Mobility Manager" limitation.

O0

08/31/2009

Added a Note to the "Installing Fabric Manager on Windows" section about the effect of a Group Policy Object (GPO) in Windows on Fabric Manager Server when used with the PostgreSQL database.

P0

07/27/2010

Added DDTS CSCsq74312.

Q0

07/29/2010

Added the "PPRC Not Supported with FCIP Write Acceleration" limitation.

Added the "Using IVR In a Fabric With Mixed Code Versions" limitation.

R0

11/03/2010

Added the Supervisor-2A module to Table 2.

S0

02/04/2011

Removed DDTS CSCsk00953, which was resolved is SAN-OS Release 3.2(2c).


Contents

This document includes the following sections:

Introduction

Components Supported

Software Download Process

Upgrading Your Cisco MDS SAN-OS Software Image

Downgrading Your Cisco MDS SAN-OS Software Image

New Features in Cisco MDS SAN-OS Release 3.2(3a)

Limitations and Restrictions

Caveats

Related Documentation

Obtaining Documentation, Obtaining Support, and Security Guidelines

Introduction

The Cisco MDS 9000 Family of Multilayer Directors and Fabric Switches provides industry-leading availability, scalability, security, and management, allowing you to deploy high performance storage-area networks with lowest total cost of ownership. Layering a rich set of intelligent features onto a high performance, protocol agnostic switch fabric, the Cisco MDS 9000 Family addresses the stringent requirements of large data center storage environments: uncompromising high availability, security, scalability, ease of management, and seamless integration of new technologies.

The Cisco MDS 9000 Family SAN-OS is the underlying system software that powers the Cisco MDS 9500 Series, 9200 Series, and 9100 Series multilayer switches. The Cisco SAN-OS provides intelligent networking features, such as multiprotocol and multitransport integration, virtual SANs (VSANs), advanced security, sophisticated debug analysis tools, and unified SAN management.

Components Supported

Table 2 lists the SAN-OS software part number and hardware components supported by the Cisco MDS 9000 Family.


Note To use the Cisco Storage Services Enabler package, Cisco MDS SAN-OS Release 1.3(5) or later must be installed on the MDS switch.


Table 2 Cisco MDS 9000 Family Supported Software and Hardware Components  

Component
Part Number
Description
Applicable Product

Software

M95S2K9-3.2.3a

MDS 9500 Supervisor/Fabric-2, SAN-OS software.

MDS 9500 Series only

M95S1K9-3.2.3a

MDS 9500 Supervisor/Fabric-I, SAN-OS software.

MDS 9500 Series only

M92S2K9-3.2.3a

MDS 9222 Supervisor/Fabric-2, SAN-OS software.

MDS 9200 Series only

M92S1K9-3.2.3a

MDS 9216 Supervisor/Fabric-I, SAN-OS software.

MDS 9200 Series only

M91S2K9-3.2.3a

MDS 9100 Supervisor/Fabric-2, SAN-OS software.

MDS 9100 Series only

M91S1K9-3.2.3a

MDS 9100 Supervisor/Fabric-I, SAN-OS software.

MDS 9100 Series only

License

M9500ENT1K9

Enterprise package.

MDS 9500 Series

M9200ENT1K9

Enterprise package.

MDS 9200 Series

M9100ENT1K9

Enterprise package.

MDS 9100 Series

M9500FIC1K9

Mainframe package.

MDS 9500 Series

M9200FIC1K9

Mainframe package.

MDS 9200 Series

M9100FIC1K9

Mainframe package.

MDS 9100 Series

M9100FIC1EK9

FICON license.

MDS 9100 Series

License

M9500FMS1K9

Fabric Manager Server package.

MDS 9500 Series

M9200FMS1K9

Fabric Manager Server package.

MDS 9200 Series

M9100FMS1K9

Fabric Manager Server package.

MDS 9100 Series

M9500EXT1K9

SAN Extension over IP package for IPS-8 module.

MDS 9500 Series

M9200EXT1K9

SAN Extension over IP package for IPS-8 module.

MDS 9200 Series

M9500EXT14K9

SAN Extension over IP package for IPS-4 module.

MDS 9500 Series

M9200EXT14K9

SAN Extension over IP package for IPS-4 module.

MDS 9200 Series

M9500EXT12K9

SAN Extension over IP package for MPS-14/2 module.

MDS 9500 Series

M9200EXT12K9

SAN Extension over IP package for MPS-14/2 module.

MDS 9200 Series

M9500EXT1AK9

SAN Extension over IP package for MSM-18/4 module or MSFM-18/4 FIPS module.

MDS 9500 Series

M9200EXT1AK9

SAN Extension over IP package for MSM-18/4 module or MSFM-18/4 FIPS module.

MDS 9200 Series

M9500SSE1K9

Storage Services Enabler package.

MDS 9500 Series with SSM

M9200SSE1K9

Storage Services Enabler package.

MDS 9200 Series with SSM

M9500SME1MK9

Cisco Storage Media Encryption package for MSM-18/4 module

MDS 9500 Series with MSM

M9200SME1MK9

Cisco Storage Media Encryption package for MSM-18/4 module

MDS 9200 Series with MSM

M9200SME1FK9

Cisco Storage Media Encryption package for fixed slot

MDS 9222i Switch only

M95DMMS1K9

Data Mobility Manager (DMM)

MDS 9500 Series with SSM

M92DMMS1K9

Data Mobility Manager (DMM)

MDS 9200 Series with SSM

M95DMMTS1K9

Data Mobility Manager (DMM) for 180 days

MDS 9500 Series with SSM

M92DMMTS1K9

Data Mobility Manager (DMM) for 180 days

MDS 9200 Series with SSM

M9124PL8-4G

On-Demand Ports Activation License

MDS 9124 Switch

M9134PL8-4G

On-Demand Ports Activation License

MDS 9134 Switch

M9134PL2-10G

On-Demand Ports Activation License

MDS 9134 Switch

HP-PL12-4G

On-Demand Ports Activation License

Cisco Fabric Switch for HP c-Class BladeSystem only

IBM-PL10-4G

On-Demand Ports Activation License

Cisco Fabric Switch for IBM BladeCenter only

Chassis

DS-C9513

MDS 9513 director (13-slot modular chassis with 11 slots for switching modules, and 2 slots reserved for Supervisor 2 modules only—SFPs1 sold separately).

MDS 9513 Switch only

DS-C9509

MDS 9509 director, base configuration (9-slot modular chassis includes 7 slots for switching modules and 2 slots for supervisor modules—SFPs sold separately).

MDS 9509 Switch only

DS-C9506

MDS 9506 director (6-slot modular chassis includes 4 slots for switching modules and 2 slots for supervisor modules—SFPs sold separately).

MDS 9506 Switch only

DS-C9222i-K9

MDS 9222i Multiservice Modular Switch (includes 18 4-Gbps Fibre Channel ports and 4 Gigabit Ethernet IP storage services ports, and a modular expansion slot for Cisco MDS 9000 Family Switching and Service modules.)

MDS 9222i Switch only

DS-C9216-K9

MDS 9216 16-port semi-modular fabric switch (includes 16 1-Gbps/2-Gbps Fibre Channel ports, power supply, and expansion slot—SFPs sold separately).

MDS 9216 Switch only

DS-C9216A-K9

MDS 9216A 16-port semi-modular fabric switch (includes 16 1-Gbps/2-Gbps Fibre Channel ports, power supply, and expansion slot—SFPs sold separately).

MDS 9216A Switch only

DS-C9216i-K9

MDS 9216i 16-port semi-modular fabric switch (includes 14 1-Gbps/2-Gbps Fibre Channel ports, 2 Gigabit Ethernet ports, power supply, and expansion slot—SFPs sold separately).

MDS 9216i Switch only

DS-C9140-K9

MDS 9140 fixed configuration (non-modular) fabric switch (includes 8 full rate ports and 32 host-optimized ports).

MDS 9140 Switch only

DS-C9124-K9

MDS 9124 fixed configuration (non-modular) multilayer fabric switch (includes 8 enabled ports; an on-demand ports activation license can enable 8 additional ports, up to 24 ports).

MDS 9124 Switch only

DS-C9134-K9

MDS 9134 fixed configuration (non-modular) multilayer fabric switch (includes 24 enabled 4-Gbps ports; an on-demand ports activation license can enable 8 additional ports, up to 32 4-Gbps ports. An additional port activation license can enable 2 10-Gbps ports.).

MDS 9134 Switch only

DS-C9120-K9

MDS 9120 fixed configuration, non-modular, fabric switch (includes4 full rate ports and 16 host-optimized ports).

MDS 9120 Switch only

DS-HP-FC-K9

Cisco Fabric Switch for HP c-Class BladeSystem (includes sixteen internal and eight external active ports and four 4-Gb SFPs installed, or eight internal and four external active ports and two 4-Gb SFPs installed).

Cisco Fabric Switch for HP c-Class BladeSystem only

DS-IBM-FC-K9

Cisco Fabric Switch for IBM BladeCenter (includes fourteen internal and six external ports)

Cisco Fabric Switch for IBM BladeCenter only

External crossbar module

DS-13SLT-FAB1

MDS 9513 crossbar fabric module.

MDS 9513 Switch only

Supervisor modules

DS-X9530-SF2-K9

MDS 9500 Supervisor-2 module.

MDS 9500 Series only

DS-X9530-SF2A-K9

MDS 9500 Supervisor-2A module.

DS-X9530-SF1-K9

MDS 9500 Supervisor/Fabric-I module.

Switching modules

DS-X9016

MDS 9000 16-port 1-Gbps/2-Gbps Fibre Channel module (SFPs sold separately).

MDS 9500 Series and 9200 Series

DS-X9032

MDS 9000 32-port 1-Gbps/2-Gbps Fibre Channel module (SFPs sold separately).

DS-X9112

MDS 9000 12-port 4-Gbps Fibre Channel module (SFPs sold separately).

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

DS-X9124

MDS 9000 24-port 4-Gbps Fibre Channel module (SFPs sold separately).

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

DS-X9148

MDS 9000 48-port 4-Gbps Fibre Channel module (SFPs sold separately).

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

DS-X9704

MDS 9000 4-port 10-Gbps Fibre Channel module (SFPs sold separately)

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

Services modules

DS-X9308-SMIP

8-port Gigabit Ethernet IP Storage services module.

MDS 9500 Series and 9200 Series

DS-X9304-SMIP

4-port Gigabit Ethernet IP Storage services module.

DS-X9032-SSM

MDS 9000 32-port 1-Gbps/2-Gbps Fibre Channel Storage Services Module (SSM).

DS-X9302-14K9

14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module.

DS-X9304-18K9

18-port Fibre Channel/4-port Gigabit Ethernet Multiservice (MSM-18/4) module.

DS-X9304-18FK9

18-port Fibre Channel/4-port Gigabit Ethernet Multiservice FIPS (MSFM-18/4) module.

Optics

DS-X2-FC10G-SR

X2/SC optics, 10-Gbps Fibre Channel for Short Reach.

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

DS-X2-FC10G-LR

X2/SC optics, 10-Gbps Fibre Channel for Long Reach.

DS-X2-FC10G-ER

X2/SC optics, 10-Gbps Fibre Channel for Extended Reach (40 km).

DS-X2-E10G-SR

X2/SC optics, 10-Gbps Ethernet for Short Reach

DS-X2-FC10G_CX4

X2/CX-4 optics, 10-Gbps Fibre Channel, copper

LC-type fiber-optic SFP

DS-SFP-FC-2G-SW

2-Gbps/1-Gbps Fibre Channel—short wavelength SFP.

MDS 9000 Family

DS-SFP-FC-2G-LW

2-Gbps/1-Gbps Fibre Channel—long wavelength SFP.

DS-SFP-FCGE-SW

1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel—short wavelength SFP.

DS-SFP-FCGE-LW

1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel—long wavelength SFP.

DS-SFP-GE-T

1-Gbps Ethernet SFP.

DS-SFP-FC4G-SW

4-Gbps/2-Gbps/1-Gbps Fibre Channel—short wavelength SFP for DS-X91xx switching modules.

MDS 9500 Series and 9200 Series, except for the MDS 9216 Switch

DS-SFP-FC4G-MR

4-Gbps/2-Gbps/1-Gbps Fibre Channel—long wavelength SFP for DS-X91xx switching modules only. Supports distances up to 4 km.

DS-SFP-FC4G-LW

4-Gbps/2-Gbps/1-Gbps Fibre Channel—long wavelength SFP for DS-X91xx switching modules only. Supports distances up to 10 km.

CWDM2

DS-CWDM-xxxx

Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps Fibre Channel SFP LC interface xxxx nm, where xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm.

MDS 9000 Family

DS-CWDM-MUX-4

Add/drop multiplexer for four CWDM wavelengths.

DS-CWDM-MUX-8

Add/drop multiplexer for eight CWDM wavelengths.

DS-CWDMCHASSIS

Two slot chassis for CWDM add/drop multiplexers.

Power supplies

DS-CAC-6000W

6000-W AC power supply.

MDS 9513 only

DS-CAC-2500W

2500-W AC power supply.

MDS 9509 only

DS-CDC-2500W

2500-W DC power supply.

DS-CAC-3000W

3000-W AC power supply.

DS-CAC-4000W-US

4000-W AC power supply for US (cable attached).

DS-CAC-4000W-INT

4000-W AC power supply international (cable attached).

DS-CAC-1900W

1900-W AC power supply.

MDS 9506 only

DS-CDC-1900W

1900-W DC power supply.

DS-CAC-845W

845-W AC power supply.

MDS 9200 Series only

DS-CAC-300W

300-W3 AC power supply.

MDS 9100 Series only

CompactFlash

MEM-MDS-FLD51M

MDS 9500 supervisor CompactFlash disk, 512 MB.

MDS 9500 Series only

Port analyzer adapter

DS-PAA-2, DS-PAA

A standalone Fibre Channel-to-Ethernet adapter that allows for simple, transparent analysis of Fibre Channel traffic in a switched fabric.

MDS 9000 Family

CD-ROM

M90FMK9-CD322=

MDS 9000 Management Software and Documentation CD-ROM, spare.

MDS 9000 Family

1 SFP = small form-factor pluggable

2 CWDM = coarse wavelength division multiplexing

3 W = Watt


Software Download Process

Use the software download procedure to upgrade to a later version, or downgrade to an earlier version, of an operating system. This section describes the software download process for the Cisco MDS SAN-OS and includes the following topics:

Determining the Software Version

Downloading Software

Selecting the Correct Software Image for an MDS 9200 Series Switch

Migrating from Supervisor-1 Modules to Supervisor-2 Modules

Configuring Generation 2 Switching Modules

Determining the Software Version

To determine the version of Cisco MDS SAN-OS software currently running on a Cisco MDS 9000 Family switch using the CLI, log in to the switch and enter the show version EXEC command.

To determine the version of Cisco MDS SAN-OS software currently running on a Cisco MDS 9000 Family switch using the Fabric Manager, view the Switches tab in the Information pane, locate the switch using the IP address, logical name, or WWN, and check its version in the Release column.


Note We strongly recommend that you use the latest available software release supported by your vendor for all Cisco MDS 9000 Family products.


Downloading Software

The Cisco MDS SAN-OS software is designed for mission-critical high availability environments. To realize the benefits of nondisruptive upgrades on the Cisco MDS 9500 Directors, we highly recommend that you install dual supervisor modules.

To download the latest Cisco MDS SAN-OS software, access the Software Center at this URL:

http://www.cisco.com/public/sw-center

See the following sections in this release note for details on how you can nondisruptively upgrade your Cisco MDS 9000 switch. Issuing the install all command from the CLI, or using Fabric Manager to perform the downgrade, enables the compatibility check. The check indicates if the upgrade can happen nondisruptively or disruptively depending on the current configuration of your switch and the reason.

Compatibility check is done:
Module  bootable          Impact  Install-type  Reason
------  --------  --------------  ------------  ------
     1       yes  non-disruptive       rolling
     2       yes      disruptive       rolling  Hitless upgrade is not supported
     3       yes      disruptive       rolling  Hitless upgrade is not supported
     4       yes  non-disruptive       rolling
     5       yes  non-disruptive         reset
     6       yes  non-disruptive         reset

At a minimum, you need to disable the default device alias distribution feature using the no device-alias distribute command in global configuration mode. The show incompatibility system bootflash:1.3(x)_filename command determines which additional features need to be disabled.


Note Refer to the "Determining Software Compatibility" section of the Cisco MDS 9000 Family CLI Configuration Guide for more details.



Note If you would like to request a copy of the source code under the terms of either GPL or LGPL, please send an e-mail to mds-software-disclosure@cisco.com.


Selecting the Correct Software Image for an MDS 9100 Series Switch

The system and kickstart image that you use for an MDS 9100 series switch depends on which switch you use, as shown in Table 3.

Table 3 Software Images for MDS 9100 Series Switch

Switch
Image

MDS 9120 or MDS 9140

Filename begins with m9100-s1ek9

MDS 9134, MDS 9124, Cisco Fabric Switch for HP BladeSystem, or Cisco Fabric Switch for IBM BladeCenter

Filename begins with m9100-s2ek9


Selecting the Correct Software Image for an MDS 9200 Series Switch

The system and kickstart image that you use for an MDS 9200 series switch depends on which switch you use, as shown in Table 4.

Table 4 Software Images for MDS 9200 Series Switches

Switch
Image

MDS 9222i

Filename begins with m9200-s2ek9

MDS 9216A or MDS 9216i

Filename begins with m9200-ek9


Selecting the Correct Software Image for an MDS 9500 Series Switch

The system and kickstart image that you use for an MDS 9500 Series switch depends on whether the switch is based on a Supervisor-1 module or a Supervisor-2 module, as shown in Table 5.

Table 5 Software Images for Supervisor Type

Supervisor Type
Switch
Image

Supervisor-1 module

MDS 9506 and 9509

Filename begins with m9500-sf1ek9

Supervisor-2 module

MDS 9506, 9509, and 9513

Filename begins with m9500-sf2ek9


Use the show module command to display the type of supervisor module in the switch. For a Supervisor-1 module, the output might look like this:

switch# show module
Mod  Ports  Module-Type                      Model              Status
---  -----  -------------------------------- ------------------ ------------
...
...
5    0      Supervisor/Fabric-1              DS-X9530-SF1-K9    active*
6    0      Supervisor/Fabric-1              DS-X9530-SF1-K9    ha-standby

For a Supervisor-2 module, the output might look like this:

switch# show module
Mod  Ports  Module-Type                      Model              Status
---  -----  -------------------------------- ------------------ ------------
...
...
7    0      Supervisor/Fabric-2              DS-X9530-SF2-K9    active *
8    0      Supervisor/Fabric-2              DS-X9530-SF2-K9    ha-standby

Migrating from Supervisor-1 Modules to Supervisor-2 Modules

As of Cisco MDS SAN-OS Release 3.0(1), the Cisco MDS 9509 and 9506 Directors support both Supervisor-1 and Supervisor-2 modules. Supervisor-1 and Supervisor-2 modules cannot be installed in the same switch, except during migration. Both the active and standby supervisor modules must be of the same type, either Supervisor-1 or Supervisor-2 modules. For Cisco MDS 9513 Directors, both supervisor modules must be Supervisor-2 modules.


Caution Migrating your supervisor modules is a disruptive operation.


Note Migrating from Supervisor-2 modules to Supervisor-1 modules is not supported.


To migrate from a Supervisor-1 module to a Supervisor-2 module, refer to the step-by-step instructions in the Cisco MDS 9000 Family CLI Configuration Guide.

Configuring Generation 2 Switching Modules

The Cisco MDS 9500 Multilayer Directors are designed to operate with any combination of Cisco MDS 9000 Generation 1 and Generation 2 modules. However, there are limitations to consider when combining the various modules and supervisors in the Cisco MDS 9500 Series platform chassis. The references listed in this section provide specific information about configurations that combine different modules and supervisors.

For information on configuring Generation 2 switching modules, refer to:

http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080664c6b.html

For information on port index availability, refer to:

http://www.cisco.com/en/US/products/ps5990/products_installation_guide_chapter09186a0080419599.html

For information on Cisco MDS 9000 hardware and software compatibility, refer to:

http://www.cisco.com/en/US/products/ps5989/products_device_support_table09186a00805037ee.html

Upgrading Your Cisco MDS SAN-OS Software Image

This section lists the guidelines recommended for upgrading your Cisco MDS SAN-OS software image and contains the following sections:

Performing a Nondisruptive Software Upgrade on Generation 1 Modules

Upgrading Your Version of Cisco Fabric Manager

General Upgrading Guidelines

Upgrading with IVR Enabled

Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.2(3a)

Upgrading the SSI Image on Your SSM

Upgrading a Switch with Insufficient Space for Two Images on the Bootflash

Upgrading a Cisco MDS 9124 Switch

Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch

Performing a Nondisruptive Software Upgrade on Generation 1 Modules

Generation 1 modules may reload during a nondisruptive SAN-OS software upgrade because of the CompactFlash being unable to partition for the new code. If that happens, the installer aborts and reloads the module.

This issue affects the following modules:

DS-X9016, 16-port 1-Gbps/2-Gbps Fibre Channel module

DS-X9032, 32-port 1-Gbps/2-Gbps Fibre Channel module

DS-X9032-SSM, 32-port 1-Gbps/2-Gbps Fibre Channel Storage Services Module (SSM)

DS-X9302-14K9, 14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module

This issue might be seen during an upgrade from Cisco SAN-OS Release 3.0(x), 3.1(x) or 3.2(x). It has been addressed for upgrades from SAN-OS Release 3.3(1) or higher. Therefore, you will not be impacted by this issue if you are running SAN-OS Release 3.3(1) when you upgrade to a higher SAN-OS release.

When this problem occurs, the module will automatically reload and may cause the Install All to stop, which will cause the upgrade to be unsuccessful. Error messages similar to the following may be displayed:

Install has failed. Return code 0x40930020 (Non-disruptive upgrade of a module failed).
Please identify the cause of the failure, and try 'install all' again.
Module 2: Non-disruptive upgrading.
-- FAIL. Return code 0x40690009 (Error in downloading image for image upgrade).

To avoid this kind of unplanned disruption, follow the methods for identifying and correcting this issue described in Cisco Field Notice 63099, before proceeding with the SAN-OS upgrade. This Field notice can be found under the Support, Products page for Cisco MDS9500 Series Multilayer Directors selection.

The caveat associated with this issue is CSCsm62295.

Upgrading Your Version of Cisco Fabric Manager

As of Cisco SAN-OS Release 3.2(1), Cisco Fabric Manager is no longer packaged with a Cisco MDS 9000

Family switch. It is included on the CD-ROM that ships with the switch. You can install Fabric Manager from the CD-ROM or from files that you download.

Installing Cisco Fabric Manager is a multi-step process that involves installing a database, as well as Fabric Manager. The complete installation instructions are provided in the "Installation of Cisco MDS SAN-OS and Fabric Manager" section in the Cisco MDS 9000 Family Fabric Manager Configuration Guide, and are available on-screen once you launch the Fabric Manager installer from the CD-ROM.

The following section presents the flow of the installation process at a high level. Review these guidelines before you begin the installation process.

1. Verify supported software. Cisco Fabric Manager has been tested with the following software:

Windows 2000 SP4, 2003 SP2, XP SP2

Redhat Linux (2.6 Kernel)

Solaris (SPARC) 8 and 10

VMWare Server 1.0:

Base Operating System: Windows 2000 SP4 / Virtual Operating System: Windows XP SP2

Base Operating System: Windows 2000 SP4 / Virtual Operating System: Windows 2000 SP4

Java Sun JRE and JDK 1.5(x) are supported

Java Web Start 1.2, 1.0.1, and 1.5

Firefox 1.5 and 2.0

Internet Explorer 6.x, and 7.0


Note Internet Explorer 7.0 is not supported on Windows 2000 SP4.


Oracle Database 10g Express

PostgreSQL 8.2 (Windows and Linux)


Note Fabric Manager Server can not be installed on an Active Directory Server when using PostgreSQL, Fabric Manager servers are domain controllers and can not create local PostgreSQL user accounts.


PostgreSQL 8.1 (Solaris)

Cisco ACS 3.1 and 4.0

PIX Firewall

IP Tables

SSH v2

Global Enforce SNMP Privacy Encryption

HTTPS

2. Ensure data migration when upgrading Cisco Fabric Manager from Cisco SAN-OS Releases 3.1(2b) and later.

If you are upgrading Cisco Fabric Manager in Cisco SAN-OS Releases 3.1(2b) and later, be aware that data is migrated from the Hypersonic HSQL database to either the PostgreSQL database or Oracle Database 10g Express during the installation. Data is also migrated from Oracle Database 10g Express to Oracle Database 10g Express. If you migrate the database from Oracle to Oracle, the schema is updated.

3. Ensure data migration when upgrading Cisco Fabric Manager from releases prior to Cisco SAN-OS Releases 3.1(2b).

If you are upgrading Fabric Manager in a Cisco SAN-OS Release prior to 3.1(2b), be aware that data is migrated from the Hypersonic HSQL database to either the PostgreSQL database or the Oracle Database 10g Express during the installation. The Fabric Manager Installer installs the PostgreSQL database on Windows. If you want to install the PostgreSQL database on Solaris or Linux, or if you want to install the Oracle Database 10g Express database, follow the instructions in the "Installation of Cisco MDS SAN-OS and Fabric Manager" section in the Cisco MDS 9000 Family Fabric Manager Configuration Guide.


Note If you are upgrading a previous installation of Fabric Manager, make sure the previous installation is installed and running. Do not uninstall the previous version. If the previous version is uninstalled, the database will not be migrated and your server settings will not be preserved.


4. Select the database.

If you want to use the Oracle Database 10g Express, you must install the database and create a user name and password before continuing with the Fabric Manager installation. We recommend the Oracle Database 10g Express option for all users who are running Performance Manager on large fabrics (1000 or more end devices).

If you want to install the PostgreSQL database, you must disable any security software you are running as PostgreSQL may not install certain folders or users. You must also log in as a Superuser before you start the installation.

5. Install Fabric Manager from the CD-ROM or from files that you download from Cisco.com at the following website:

http://cisco.com/cgi-bin/tablebuild.pl/mds-fm

Installing Fabric Manager on Solaris

This section describes how to install Fabric Manager on Solaris.

To install Fabric Manager on Solaris, follow these steps:


Step 1 Set Java 1.5 to the path that is to be used for installing Fabric Manager.

Step 2 Install the database that is to be used with Fabric Manager.

Step 3 Copy the Fabric Manager jar file m9000-fm-3.2.3a.jar from the CD-ROM to a folder on the Solaris workstation.

Step 4 Launch the installer using the following command:

java -Xms512m -Xmx512m -jar m9000-fm-3.2.3a.jar

Step 5 Follow the onscreen instructions provided in the Fabric Manager management software setup wizard.


Installing Fabric Manager on Windows

This section describes how to install Fabric Manager on Windows.


Note Fabric Manager Server can not be installed on an Active Directory Server when using PostgreSQL, Fabric Manager servers are domain controllers and can not create local PostgreSQL user accounts.



Note If you are running Fabric Manager Server on Windows and using the PostgreSQL database, you should examine your Windows Active Directory environment for organizational units (OUs) and make the change recommended below to ensure that Fabric Manager Server does not periodically stop working.

On a Windows system, the Microsoft Active Directory applies a Group Policy Object (GPO) to the Fabric Manager Server. The GPO does not recognize the local user PostgreSQL because it is not in the GPO allow list. As a result, the GPO removes it, and the PostgreSQL database stops working.

To avoid this situation, you should move the Fabric Manager Server to its own OU and apply the same feature settings as the original OU, but remove the local user account to log in as a service.


If your server is running Terminal Services in Application mode, or if you are running Citrix Metaframe or any variation thereof, you need to issue the following command on the DOS prompt before installing Fabric Manager Server.

1. Open a command-line prompt: Start > Run, then type cmd and press Return.

2. At the command prompt type: Change user /install.


Note Do not close the command line window. This must remain open for the entire duration of the install.


The following is an example of the output of this command:

C:\Documents and Settings\user.domain>CHANGE USER /INSTALL
User session is ready to install applications.

3. Follow all steps needed to install Fabric Manager, Fabric Manager Server, and Device Manager. See the instructions later in this section.

4. When the installation is complete, at the command prompt, type change user /execute and press Return. Then type exit and press Return.

The following is an example of the output of this command:

C:\Documents and Settings\user.domain>CHANGE USER /execute
User session is ready to execute applications.

To install Fabric Manager on Windows, follow these steps:


Step 1 Click the Install Management Software link.

Step 2 Choose Management Software > Cisco Fabric Manager.

Step 3 Click the Installing Fabric Manager link.

Step 4 Select the drive for your CD-ROM.

Step 5 Click the FM Installer link.

Step 6 Follow the onscreen instructions provided in the Fabric Manager Installer 3.2(3a).


To install Device Manager on your workstation, follow these steps:


Step 1 Enter the IP address of the switch in the Address field of your browser.

Step 2 Click the Cisco Device Manager link in the Device Manager installation window.

Step 3 Click Next to begin the installation.

Step 4 Follow the onscreen instructions to complete the installation of Device Manager.



Note If you use a Java JDK instead of a JRE on Solaris, you might encounter a problem trying to install the Device Manager from a web browser. This can happen because the installer heap limit of 256 MB is not sufficient. If you have this problem, save the jnlp link as file, increase the heap limit to 512 MB, and run javaws element-manager.jnlp at the shell prompt.


General Upgrading Guidelines

Use the following guidelines when upgrading to Cisco MDS SAN-OS Release 3.2(3a):

Install and configure dual supervisor modules.

Issue the show install all impact upgrade-image CLI command to determine if your upgrade will be nondisruptive.


Note When upgrading from Release 2.0(1) or later to Release 3.2(3a), modules may reload and disrupt traffic after an upgrade using the install all command if an enhanced zoning lock exists. To avoid this issue, commit or clear the zone locks and then rerun the install all command. Issue the show zone status command to check if an enhanced zoning lock exists. Do not make enhanced zoning changes while an upgrade is in progress.


Follow the recommended guidelines for upgrading a Cisco MDS 9124 Switch as described in "Upgrading a Cisco MDS 9124 Switch" section.

Follow the guidelines for upgrading a single supervisor switch as described in "Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch" section.

Be aware that some features impact whether an upgrade is disruptive or nondisruptive:

Fibre Channel Ports: Traffic on Fibre Channel ports can be nondisruptively upgraded. See Table 6 for the nondisruptive upgrade path for all SAN-OS releases.

SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write acceleration, is disrupted during an upgrade. SSM Fibre Channel traffic is not.

Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during an upgrade or downgrade. This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the upgrade is in progress.

Inter-VSAN Routing (IVR): With IVR enabled, you must follow additional steps if you are upgrading from Cisco SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the "Upgrading with IVR Enabled" section for these instructions.

FICON: If you have FICON enabled, the upgrade path is different. See Table 7.

Use Table 6 to determine your nondisruptive upgrade path to Cisco SAN-OS Release 3.2(3a). Find the image release number you are currently using in the Current column of the table and use the path recommended.


Note The software upgrade information in Table 6 applies only to Fibre Channel switching traffic. Upgrading system software disrupts IP traffic and SSM intelligent services traffic.


Table 6 Nondisruptive Upgrade Path to SAN-OS Release 3.2(3a) 

Current
Nondisruptive Upgrade Path

SAN-OS 3.2(3)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.2(2c)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.2(1a)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(4)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(3a)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(2b)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(2a)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(2)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.1(1)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.0(3a)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.0(3)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.0(2a)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.0(2)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 3.0(1)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 2.1(3)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 2.1(2e)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 2.1(2d)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 2.1(2b)

You can nondisruptively upgrade directly to SAN-OS Release 3.2(3a).

SAN-OS 2.1(2)

Upgrade to SAN-OS Release 2.1(2b) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2d) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2e) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(3) and then upgrade to Release 3.2(3a).

SAN-OS 2.1(1b)

Upgrade to SAN-OS Release 2.1(2b) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2d) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2e) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(3) and then upgrade to Release 3.2(3a).

SAN-OS 2.1(1a)

Upgrade to SAN-OS Release 2.1(2b) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2d) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2e) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(3) and then upgrade to Release 3.2(3a).

SAN-OS 2.0(x)

Upgrade to SAN-OS Release 2.1(2b) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2d) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(2e) and then upgrade to Release 3.2(3a).
or
Upgrade to SAN-OS Release 2.1(3) and then upgrade to Release 3.2(3a).

SAN-OS 1.x

Upgrade to SAN-OS Release 1.3(4a), then to Release 2.1(2b), and then upgrade to Release 3.2(3a).


FICON Supported Releases and Upgrade Paths

Cisco MDS SAN-OS Release 3.2(3a) does not support FICON.

Table 7 lists the SAN-OS and NX-OS releases that support FICON. Refer to the specific release notes for FICON upgrade path information.

Table 7 FICON Supported Releases 

FICON Supported Releases

NX-OS

Release 4.1(1c)

SAN-OS

Release 3.3(1c)

Release 3.2(2c)

Release 3.0(3b)

Release 3.0(3)

Release 3.0(2)

Release 2.0(2b)


Upgrading with IVR Enabled

An Inter-Switch Link (ISL) flap resulting in fabric segmentation or a merge during or after an upgrade from Cisco MDS SAN-OS Release 2.0(x) to a later image where IVR is enabled might be disruptive. Some possible scenarios include the following:

FCIP connection flapping during the upgrade process resulting in fabric segmentation or merge.

ISL flap results in fabric segmentation or merge because of hardware issues or a software bug.

ISL port becomes part of PCP results in fabric segmentation or merge because of a port flap.

If this problem occurs, syslogs indicate a failure and the flapped ISL could remain in a down state because of a domain overlap.

This issue was resolved in Cisco SAN-OS Release 2.1(2b); you must upgrade to Release 2.1(2b) before upgrading to Release 3.2(3a). An upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) when IVR is enabled requires that you follow the procedure below, and then follow the upgrade guidelines listed in the "Upgrading Your Version of Cisco Fabric Manager" section. If you have VSANs in interop mode 2 or 3, you must issue an IVR refresh for those VSANs.

To upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) for all other VSANs with IVR enabled, follow these steps:


Step 1 Configure static domains for all switches in all VSANs where IVR is enabled. Configure the static domain the same as the running domain so that there is no change in domain IDs. Make sure that all domains are unique across all of the IVR VSANs. We recommend this step as a best practice for IVR-non-NAT mode. Issue the fcdomain domain id static vsan vsan id command to configure the static domains.


Note Complete Step 1 for all switches before moving to Step 2.


Step 2 Issue the no ivr virtual-fcdomain-add vsan-ranges vsan-range command to disable RDI mode on all IVR enabled switches. The range of values for a VSAN ID is 1 to 4093. This can cause traffic disruption.


Note Complete Step 2 for all IVR enabled switches before moving to Step 3.


Step 3 Check the syslogs for any ISL that was isolated.

2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: 
%$VSAN 2005%$ Isolation of interface 
port-channel 52 (reason: unknown failure)
2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: %$VSAN 2005%$ 
Isolation of interface port-channel 51 
(reason: domain ID assignment failure)

Step 4 Issue the following commands for the isolated switches in Step 3:

switch(config)# vsan database
switch(config-vsan-db)# vsan vsan-id suspend
switch(config-vsan-db)# no vsan vsan-id suspend

Step 5 Issue the ivr refresh command to perform an IVR refresh on all the IVR enabled switches.

Step 6 Issue the copy running-config startup-config command to save the RDI mode in the startup configuration on all of the switches.

Step 7 Follow the normal upgrade guidelines for Release 2.1(2b). If you are adding new switches running Cisco MDS SAN-OS Release 2.1(2b) or later, upgrade all of your existing switches to Cisco SAN-OS Release 2.1(2b) as described in this workaround. Then follow the normal upgrade guidelines for Release 3.2(3a).


Note RDI mode should not be disabled for VSANs running in interop mode 2 or interop mode 3.



Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.2(3a)

Starting with Cisco MDS SAN-OS Release 3.0(1), the SSM front panel ports can no longer be configured in auto mode, which is the default for releases prior to Release 3.0(1).


Note To avoid any traffic disruption, modify the configuration of the SSM ports as described below, before upgrading a SAN-OS software image prior to Release 3.2(3a).


For more information on upgrading SAN-OS software, see the "Upgrading Your Cisco MDS SAN-OS Software Image" section.

If the configuration is not updated before the upgrade, the installation process for the new image will automatically convert all ports configured in auto mode to Fx mode. This change in mode might cause a disruption if the port is currently operating in E mode.

To upgrade the image on your SSM without any traffic disruption, follow these steps:


Step 1 Verify the operational mode for each port on the SSM using the show interface command:

switch# show interface fc 2/1 - 32
fc2/1 is up
    Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
    Port WWN is 20:4b:00:0d:ec:09:3c:00
    Admin port mode is auto             <-------- shows port is configured in auto mode
    snmp traps are enabled
    Port mode is F, FCID is 0xef0300   <-------- shows current port operational mode is F
    Port vsan is 1
    Speed is 2 Gbps
    Transmit B2B Credit is 3

Step 2 Change the configuration for the first port of the quad when the admin port mode is auto. (A quad is a group of four ports, supported by a data path processor (DPP). The groups are 1 to 4, 5 to 8, 9 to 12, and so on.) Do not leave the port mode set to auto.

a. Set the port admin mode to E or Fx if the current operational port mode is E, TE, F or FL.

switch# config t
switch(config)# interface fc 2/1
switch(config-if)# switchport mode fx

b. Set the port admin mode to E if the current operational port mode is E:

switch# config t
switch(config)# interface fc 2/5
switch(config-if)# switchport mode e

Step 3 Change the configuration for ports 2, 3, and 4 of the quad:

a. Set the admin port mode to Fx if the admin port mode of these ports is E, TE, or auto.

switch# config t
switch(config)# interface fc 2/2
switch(config-if)# switchport mode fx

b. If the first port in the port group has admin mode E or if the port is operational in E port mode, change the admin state of ports 2, 3, and 4 to shutdown.

switch# config t
switch(config)# interface fc 2/2
switch(config-if)# shutdown

Step 4 Save the running configuration to the startup configuration before the upgrade procedure to ensure that the changes are preserved during and after the upgrade. To save the configuration, enter the following command:

switch# copy running-config startup-config

Upgrading the SSI Image on Your SSM

Use the following guidelines to nondisruptively upgrade the SSI image on your SSM:

Install and configure dual supervisor modules.

SSM intelligent services traffic on SSM ports is disrupted during upgrades. Fibre Channel switching traffic is not disrupted under the following conditions:

Upgrade the SSI boot images on the SSMs on the switch to a release version supported by your Cisco SAN-OS release. Refer to the Cisco MDS SAN-OS Release Compatibility Matrix for Storage Service Interface Images.

All SSM applications are disabled. Use the show ssm provisioning CLI command to determine what applications are configured. Use the no ssm enable feature CLI command to disable these applications.

No SSM ports are in auto mode. See the "Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.2(3a)" section.

The EPLD version on the SSM is at 0x07 or higher. Use the show version module slot epld CLI command to determine your EPLD version. Refer to the Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images to upgrade your EPLD image.

Refer to the Cisco MDS Storage Services Module Interoperability Support Matrix and the "Managing Modules" chapter in the Cisco MDS 9000 Family CLI Configuration Guide, Release 3.x, for information on upgrading your SSM.


Caution Upgrading from Cisco MDS SAN-OS Release 2.1(1b) or earlier to Release 2.1.2 or later can disrupt traffic on any SSM installed on your MDS switch

Upgrading a Switch with Insufficient Space for Two Images on the Bootflash

To upgrade the SAN-OS image on a Cisco MDS 9000 Family switch requires enough space on the internal CompactFlash (also referred to as bootflash) to accommodate both the old software image and the new software image.

As of Cisco MDS SAN-OS Release 3.1(1), on MDS switches with a 256-MB CompactFlash, it is possible in some scenarios that a user might be unable to fit two images on the bootflash. This lack of space on the bootflash might cause the upgrade process to fail because new images are always copied onto the bootflash during an upgrade.

The following MDS switches are affected by this issue:

MDS 9216 and MDS 9216i

MDS 9120 and MDS 9140

MDS 9500 Series switches with a Supervisor 1 module

To work around an image upgrade failure caused by a lack of space on the bootflash, follow these steps:


Step 1 Prior to installing the new image, copy the old (existing) system image file to an external server. You may need to reinstall this file later.

Step 2 Delete the old system image file from the bootflash by using either the Fabric Manager install utility or the CLI delete bootflash: command. The system image file does not contain the word "kickstart" in the filename.
switch# delete bootflash:m9200-ek9-mz.3.0.3.bin


Note On MDS 9500 Series switches, you also need to delete the image file from the standby supervisor after deleting it from the active supervisor.
switch# delete bootflash://sup-standby/m9500-sf1ek9-mz.3.0.3.bin


Step 3 Start the image upgrade or installation process using the Fabric Manager install utility or the CLI install all command.

Step 4 If the new installation or upgrade fails while copying the image and you want to keep the old (existing) image, then copy the old image (that you saved to an external server in Step 1) to the bootflash using either Fabric Manager or the copy command.

Step 5 If the switch fails to boot, then follow the recovery procedure described in the "Troubleshooting Installs, Upgrades, and Reboots" section of the Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x.

Upgrading a Cisco MDS 9124 Switch

If you are upgrading from Cisco MDS SAN-OS Release 3.1(1) to Cisco SAN-OS Release 3.2(3a) on a Cisco MDS 9124 Switch, follow these guidelines:

During the upgrade, configuration is not allowed and the fabric is expected to be stable.

The Fabric Shortest Path First (FSPF) timers must be configured to the default value of 20 seconds; otherwise, the nondisruptive upgrade is blocked to ensure that the maximum down time for the control plane can be 80 seconds.

If there are any CFS commits in the fabric, the nondisruptive upgrade will fail.

If there is a zone server merge in progress in the fabric, the nondisruptive upgrade will fail.

If a service terminates the nondisruptive upgrade, the show install all failure-reason command can display the reason that the nondisruptive upgrade cannot proceed.

If there is not enough memory in the system to load the new images, the upgrade will be made disruptive due to insufficient resources and the user will be notified in the compatibility table.

Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch

Cisco MDS SAN-OS software upgrades are disruptive on the following single supervisor Cisco MDS Family switches:

MDS 9120 switch

MDS 9140 switch

MDS 9216i switch

If you are performing an upgrade on one of those switches, you should follow the nondisruptive upgrade path shown in Table 6, even though the upgrade is disruptive. Following the nondisruptive upgrade path ensures that the binary startup configuration remains intact.

If you do not follow the upgrade path, (for example, you upgrade directly from SAN-OS Release 2.1(2) or earlier version to SAN-OS Release 3.2(3a)), the binary startup configuration is deleted because it is not compatible with the new image, and the ASCII startup configuration file is applied when the switch comes up with the new upgraded image. When the ASCII startup configuration file is applied, there may be errors. Because of this, we recommend that you follow the nondisruptive upgrade path.

Downgrading Your Cisco MDS SAN-OS Software Image

This section lists the guidelines recommended for downgrading your Cisco MDS SAN-OS software image and contains the following sections:

General Downgrading Guidelines

Downgrading the SSI Image on Your SSM

General Downgrading Guidelines

Use the following guidelines to nondisruptively downgrade your Cisco MDS SAN-OS Release 3.2(3a):

Install and configure dual supervisor modules.

Issue the system no acl-adjacency-sharing execute command to disable acl adjacency usage on Generation 2 and Generation 1 modules. If this command fails, reduce the number of zones, IVR zones, TE ports, or a combination of these in the system and issue the command again.

Disable all features not supported by the downgrade release. Use the show incompatibility system downgrade-image CLI command to determine what you need to disable.

Layer 2 switching traffic is not disrupted when downgrading to Cisco SAN-OS Release 2.1(2) or later.

Use the show install all impact downgrade-image CLI command to determine if your downgrade will be nondisruptive.

Be aware that some features impact whether a downgrade is disruptive or nondisruptive:

Fibre Channel Ports: Traffic on Fibre Channel ports can be nondisruptively downgraded. See Table 8 for the nondisruptive downgrade path for all SAN-OS releases.

SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write acceleration, is disrupted during a downgrade. SSM Fibre Channel traffic is not.

Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during a downgrade. This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the downgrade is in progress.

iSCSI: If you are downgrading from SAN-OS version 3.0(x) to a lower version of SAN-OS, enable iSCSI if an IPS module, MPS-14/2 module, MSM-18/4 module, or the MDS 9222i switch is online. Otherwise, the downgrade will disrupt traffic.

IVR: With IVR enabled, you must follow additional steps if you are downgrading from Cisco SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the "Upgrading with IVR Enabled" section for these instructions.

Use Table 8 to determine the nondisruptive downgrade path from Cisco SAN-OS Release 3.2(3a). Find the SAN-OS image you want to downgrade to in the To SAN-OS Release column of the table and use the path recommended.


Note The software downgrade information in Table 8 applies only to Fibre Channel switching traffic. Downgrading system software disrupts IP and SSM intelligent services traffic.


Table 8 Nondisruptive Downgrade Path from SAN-OS Release 3.2(3a)

To SAN-OS Release
Nondisruptive Downgrade Path

SAN-OS 3.2(3)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.2(2c)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.2(1a)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1(4)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1(3a)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1(2b)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1(2)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.1(1)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.0(3a)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.0(3)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.0(2a)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.0(2)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 3.0(1)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 2.1(3)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 2.1(2e)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 2.1(2d)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 2.1(2b)

You can nondisruptively downgrade directly from SAN-OS Release 3.2(3a).

SAN-OS 2.1(2)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.1(2).

SAN-OS 2.1(1b)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.1(1b).

SAN-OS 2.1(1a)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.1(1a).

SAN-OS 2.0(4a)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.0(4a).

SAN-OS 2.0(4)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.0(4).

SAN-OS 2.0(3)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.0(3).

SAN-OS 2.0(2b)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.0(2b).

SAN-OS 2.0(1b)

Downgrade to SAN-OS Release 2.1(2b) and then downgrade to Release 2.0(1b).

SAN-OS 1.x

Downgrade to SAN-OS to Release 2.1(2b), then to Release 1.3(4a), and then downgrade to your SAN-OS 1.x release.


FICON Downgrade Paths

Cisco MDS SAN-OS Release 3.2(3a) does not support FICON.

Refer to Table 7 for a list SAN-OS and NX-OS releases that support FICON. Refer to the specific release notes for FICON downgrade path information.

Downgrading the SSI Image on Your SSM

Use the following guidelines when downgrading your SSI image on your SSM.

On a system with at least one SSM installed, the install all command might fail on an SSM when you downgrade from Cisco SAN-OS Release 3.2(3a) to any SAN-OS 2.x release earlier than SAN-OS Release 2.1(2e). Power down the SSM and perform the downgrade. Bring up the SSM with the new bootvar set to the 2.x SSI image.

Downgrade the SSI boot images on the SSMs on the switch to a release version supported by your Cisco SAN-OS release. Refer to the Cisco MDS SAN-OS Release Compatibility Matrix for Storage Service Interface Images.

SSM intelligent services traffic switching on SSM ports is disrupted on upgrades or downgrades.

Fibre Channel switching traffic on SSM ports is not disrupted under the following conditions:

All SSM applications are disabled. Use the show ssm provisioning CLI command to determine if any applications are provisioned on the SSM. Use the no ssm enable feature configuration mode CLI command to disable these features.

The EPLD version on the SSM is at 0x07 or higher. Use the show version module slot epld CLI command to determine your EPLD version. Refer to the Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images to upgrade your EPLD image.

Refer to the Cisco MDS Storage Services Module Interoperability Support Matrix and to the "Managing Modules" chapter in the Cisco MDS 9000 Family CLI Configuration Guide, Release 3.x for information on downgrading your SSM.

New Features in Cisco MDS SAN-OS Release 3.2(3a)

This section briefly describes the new features introduced in this release. For detailed information about the features listed, refer to the Cisco MDS 9000 Family CLI Configuration Guide, the Cisco MDS 9000 Family Fabric Manager Configuration Guide, and the Cisco MDS 9000 Family Storage Media Encryption Configuration Guide. For information about new CLI commands associated with these features, refer to the Cisco MDS 9000 Family Command Reference. The "New and Changed Information" section in each of these books provides a detailed list of all new features and includes links to the feature description or new command.


Note These release notes are specific to this release. For the complete Release 3.x documentation set, see the "Related Documentation" section.


There are no new features available for this release.

Limitations and Restrictions

This section lists the limitations and restrictions for this release. This section includes the following topics:

Upgrading to Recover Loss of Performance Manager Data

Maximum Number of Zones Supported in Interop Mode 4

CompactFlash Check Utility

Cisco SME Configuration Limits

Java Web Start

Compatibility of Fabric Manager and Data Mobility Manager

PPRC Not Supported with FCIP Write Acceleration

Using IVR In a Fabric With Mixed Code Versions

Upgrading to Recover Loss of Performance Manager Data


Caution You must upgrade to Fabric Manager Release 3.1(x) and then upgrade to a later release of Fabric Manager to avoid losing Performance Manager data. If data has been lost, follow the steps below to recover the data.


Step 1 Disable Performance Manager interpolation using Fabric Manager Web Client. Uncheck Interpolate missing statistics, then click Apply.

Step 2 Stop the Fabric Manager Server.

Step 3 Save the data file in the $INSTALL_DIR directory.

Step 4 Move the old RRD file into the $INSTALL_DIR/pm/db directory.

Step 5 Run $INSTALL_DIR/bin/pm.bat m.

Step 6 Restart Fabric Manager Server.


Maximum Number of Zones Supported in Interop Mode 4

In interop mode 4, the maximum number of zones that is supported in an active zone set is 2047, due to limitations in the connected vendor switch.

When IVR is used in interop mode 4, the maximum number of zones supported, including IVR zones, in the active zone set is 2047.

CompactFlash Check Utility

The Cisco Fabric Manager CompactFlash Check Utility can only check compact flash on switches running SAN-OS Release 3.1(2b) or earlier. This utility should not be run on switches running Release 3.1(3) or later.

Starting with SAN-OS Release 3.1(3), the ability to detect a faulty CompactFlash is built into the SAN-OS software. A new CompactFlash cyclic redundancy check (CRC) checksum test can check the state of the CompactFlash firmware on select modules. If the CompactFlash firmware is not corrupted, then the SAN-OS software can automatically update the CompactFlash firmware.

By default, the new CompactFlash CRC checksum test is enabled to automatically run in the background every seven days. New command-line interface (CLI) commands allow you to run the test on demand, change the automatic test interval, and disable the automatic testing. Issue the system health cf-crc-check module x command and the system health cf-re-flash module x command to run the test on demand. For more information, refer to the Cisco MDS 9000 Family Command Reference, Release 3.x.

Cisco SME Configuration Limits

Table 9 lists the Cisco SME configuration limits for this release.

Table 9 Cisco SME Limits

Configuration
Limit

Number of clusters per switch

1

Switches in a cluster

4

Fabrics in a cluster

1

Modules in a switch

11

Cisco MSM-18/4 modules in a cluster

32

Initiator-Target-LUNs (ITLs)

128

LUNs behind a target

32

Host and target ports in a cluster

128

Number of hosts per target

8

Tape backup groups per cluster

2

Volume groups in a tape backup group

4

Cisco Key Management Center (# of keys)

32K

Targets per switch that can be FC-redirected

32


Java Web Start

When using Java Web Start, it is recommended that you do not use an HTML cache or proxy server. You can use the Java Web Start Preferences panel to view or edit the proxy configuration. To do this, launch the Application Manager, either by clicking the desktop icon (Microsoft Windows), or type ./javaws in the Java Web Start installation directory (Solaris Operating Environment and Linux), and then select Edit>Preferences.

If you fail to change these settings, you may encounter installation issues regarding a version mismatch. If this occurs, you should clear your Java cache and retry.

Compatibility of Fabric Manager and Data Mobility Manager

Cisco Fabric Manager in any MDS NX-OS 4.1(x) release does not support Data Mobility Manager (DMM) in any SAN-OS 3.3(x) release or in any 3.2(x) release. To use the Cisco Fabric Manager GUI for DMM, both Fabric Manager and DMM must be running NX-OS or SAN-OS software from the same release series.

PPRC Not Supported with FCIP Write Acceleration

IBM Peer to Peer Remote Copy (PPRC) is not supported with FCIP Write Acceleration.

Using IVR In a Fabric With Mixed Code Versions

If you are using IVR and you are running SAN-OS 3.x software on your MDS switches, make sure that all IVR switches run the same code version. Otherwise, if you have a fabric with mixed code versions, the switches running the higher version may not be able to see all IVR devices. The mixed fabric can cause an inconsistent database among IVR switches, which might affect IVR behavior. For this reason, it is important that all IVR switches run the same SAN-OS version, preferably SAN-OS Release 3.3(4a), which has device update (DU) support, or later.

Caveats

This section lists the open and resolved caveats for this release. Use Table 10 to determine the status of a particular caveat. In the table, "O" indicates an open caveat and "R" indicates a resolved caveat.

Table 10 Open Caveats and Resolved Caveats Reference 

DDTS Number
Software Release (Open or Resolved)
 
3.2(3)
3.2(3a)

Severity 2

CSCsg49151

O

O

CSCsi72048

O

O

CSCsi87843

O

R

CSCsk43922

O

O

CSCsk49029

O

O

CSCsk49634

O

O

CSCsk49761

O

R

CSCsk51193

O

O

CSCsl39215

O

O

CSCsl46583

O

R

CSCsl71227

O

O

CSCsl73987

O

R

CSCsl86532

O

R

CSCsm15855

O

R

CSCsm38140

O

R

CSCsm75402

O

CSCso72230

O

O

Severity 3

CSCin95789

O

O

CSCse31881

O

O

CSCse47687

O

O

CSCsg19148

O

O

CSCsg19303

O

O

CSCsi66310

O

O

CSCsj24904

O

O

CSCsj72666

O

O

CSCsk06186

O

O

CSCsk35725

O

O

CSCsk35951

O

O

CSCsk49309

O

O

CSCsk63929

O

O

CSCsk87502

O

O

CSCsk87614

O

O

CSCsk93834

O

O

CSCsk95241

O

O

CSCsl12130

O

O

CSCsl12611

O

O

CSCsl15511

O

O

CSCsl17944

O

O

CSCsl31087

O

O

CSCsl33763

O

O

CSCsl34922

O

O

CSCsl60060

O

R

CSCsl65951

O

O

CSCsm08837

O

O

CSCsm20225

O

R

CSCsm34898

O

R

CSCsm56190

O

CSCso63465

O

O

Severity 4

CSCsi56167

O

O

CSCsk91974

O

O

Severity 5

CSCsk73654

O

O

Severity 6

CSCsk43927

O

O

CSCsm13002

O

O

CSCsm15874

O

O

CSCsm17768

O

O

CSCsm18303

O

O

CSCsm32677

O

R

CSCso04862

O

CSCsq74312

O


Resolved Caveats

CSCsi87843

Symptom: Cisco MDS 9000 Family switches that are running SAN-OS Release 3.1(x) or Release 3.2(x) may display corrupt memory when the show cfs internal message-context <app-name> command is issued. This is seen only on MDS 9000 Family switches that are running SAN-OS Release 3.1(x) or Release 3.2(x) when a CFS-enabled application is processing more than one distribution at a time in a fabric with more than one switch.

Workaround: This issue is resolved.

CSCsk49761

Symptom: When IVR exports a new virtual domain and multiple border switches export that virtual domain, some of the entries in the Fibre Channel name server (FCNS) database that correspond to this virtual domain may have partial entries where the port type contains a dash (-). This can then lead to a lack of IVR communication between these devices and other IVR devices.

Workaround: This issue is resolved.

CSCsl46583

Symptom: When portchannels are up, Fabric Manager Client shows some portchannels as down. When highlighted, the portchannel tooltip shows "vsanInactive".

Workaround: This issue is resolved.

CSCsl73987

Symptom: In rare instances, when a SCSI I/O is in progress in Cisco SME and it is aborted by the host, the Cisco SME interface may fail and a reset may occur.

Workaround: This issue is resolved.

CSCsl86532

Symptom: When the Fabric Manager server is upgraded from SAN-OS Release 3.2.1a or Release 3.2.1b to Release 3.2.2c or Release 3.2.3, the upgrade.sql script is not executed. In this case, the database table will not be shown.

Workaround: This issue is resolved.

CSCsm15855

Symptom: Manually purging the keys in SME integrated with the RSA Key Manager Vault, causes the key lookup to fail and timeout. This prevents the tapes from being recycled.

Workaround: This issue is resolved.

CSCsm38140

Symptom: After an upgrade from SAN-OS Release 3.1.3a to Release 3.2.3 or Release 3.2.3a, some IVR devices are missing from the Fibre Channel name server (FCNS) database in a local VSAN or in IVR transit VSANs. This may occur after a Supervisor switchover when the FCNS attempts to query IVR and receives an MTS response failure from IVR.

Workaround: This issue is resolved.

CSCsl60060

Symptom: Fabric Manager sometimes fails discovering the device alias.

Workaround: This issue is resolved.

CSCsm20225

Symptom: After upgrading multiple MDS 9000 Family switches from SANOS Release 3.1.3a to Release 3.2.3, and while running IVR NAT, Fibre Channel name server (FCNS) entries may not appear in the transit VSANs. This may stop the FCNS service. If this occurs, the following messages will be displayed:

%SYSMGR-3-HEARTBEAT_FAILURE: Service "fcns" sent SIGABRT for not setting heartbeat for last 5 periods

%SYSMGR-3-SERVICE_CRASHED: Service "fcns" (PID 1649) hasn't caught signal 6 (core saved).

Workaround: This issue is resolved.

CSCsm34898

Symptom: Fabric Manager discovers fabrics correctly; however, the display pane shows inconsistencies and missing elements (for example, missing devices, links between devices, and so on). This occurs only when there are EMC FICON adapters present in the fabric.

Workaround: This issue is resolved.

CSCsm32677

Symptom: When a SCSI status frame to the host is lost, with FCP sequence error recovery procedures enabled, causes the encryption engine in the MSM-18/4 module to reset.

Workaround: This issue is resolved.

Open Caveats

CSCsg49151

Symptom: If you bring up more than one link at a time between two VSANs that have overlapping domains and at least one of the switches is SDV enabled, one link will become isolated. The other links will come up, even though the domains are overlapping. In addition, the SDV virtual domains will change, causing traffic disruption on all devices associated with their old value.

Workaround: Bring up multiple links between two switches one at a time. Verify that the first link came up correctly before attempting to bring up the next link. If the first link fails to come up because of a domain ID overlap, resolve the domain conflict and then try again to bring up the links.

CSCsi72048

Symptom: FCIP links may fail on an MDS 9216i switch that has compression set to auto when the other end of the FCIP link is terminated by an IPS-8 module. You may see the following message in the logs:

%IPS_SB_MGR-SLOT1-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error 0x1)
%ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface GigabitEthernet1/1 is down (Port software failure)
%PORT-5-IF_DOWN_SOFTWARE_FAILURE: %$VSAN 1%$ Interface fcip99 is down (Port software failure)

Workaround: If both ends of an FCIP link are not on an MPS-14/2 module, do not use mode 1 and auto.

CSCsk43922

Symptom: A data path processor (DPP) might fail on an MDS switch running SSI Release 3.2(1) on the SSM. The failure occurs after several days of running traffic when a misbehaving target sends unexpected frames well after the response has already been received from the same target.

Workaround: None.

CSCsk49029

Symptom: If there is a request to export a domain while the same domain is being cleaned up, domain entries might not be programmed. As a result, communication between IVR devices might not occur.

Workaround: Because the programming request was lost, the only way to retrigger the programming is to withdraw the domain and refresh IVR. Follow these steps:

1. Identify domains with problem using the show ivr internal dep command.

switch# show ivr internal dep
Internal information for DEP FSM
--------------------------------
vsan domain nh status sync_status req i/f
101 0x61(97) 1001 ALL_DONE OXID|FCID_RW 0 [ fc3/2 ] 
102 0x62(98) 1002 ALL_DONE OXID|FCID_RW 0 [ fc3/5 ] 
1001 0x9e(158) 101 NONE OXID|FCID_RW 0 [ fc2/16 ] 
1002 0x98(152) 102 ALL_DONE OXID|FCID_RW 0 [ fc9/10]
Number of DEP entries : 4

After waiting for a few minutes for IVR to stabilize, if the status column for the {vsan, domain} combination is NONE, then this problem has occurred the switch.

2. Withdraw the troubled domains using the ivr withdraw domain domain vsan vsan-id command.

3. Readvertise the withdrawn domains using the ivr refresh command.

CSCsk49634

Symptom: In rare cases, an FCIP link might flap on a network with high latency and a consistently high loss rate (above 100ms RTT and 0.5% loss).

Workaround: None.

CSCsk51193

Symptom: Following an upgrade to Cisco MDS SAN-OS Release 3.2(1) on a Cisco MDS 9124 switch, an interface is shown as up, but there is no FLOGI information for the port in the FLOGI database.

Workaround: Set the port mode to F.

CSCsl39215

Symptom: The CIM server stops. This occurs after creating a subscription using the same filter and handler.

Workaround: Reload the switch.

CSCsl71227

Symptom: Using Fabric Manager Release 3.2(2), if you have an enclosure with multiple ports and you then use the Data Migration Wizard to create a job with that enclosure as the existing storage but don't select all the storage ports in the enclosure, an error is displayed in the creation wizard.

Workaround: Put the ports you plan to use as the existing storage in the migration into a separate enclosure, and use that enclosure in the wizard selection.

CSCsm75402

Symptom: The running configuration can not be saved using Device Manager on the MDS 9020 switch.

Workaround: Use Telnet or SSH to access the MDS 9020 switch and issue the copy running-config startup-config CLI command.

CSCso72230

Symptom: In rare instances, the following Generation 2 modules might reload:

12-port 4-Gbps Fibre Channel module

24-port 4-Gbps Fibre Channel module

48-port 4-Gbps Fibre Channel module

4-port 10-Gbps Fibre Channel module

The output of the show logging log command will have events like those shown below. In the following output, module 7 is the supervisor and module 12 is the module that reloaded.

2008 Jul 15 19:39:30 fcd95c41 %MODULE-4-MOD_WARNING: Module 7 (serial: JAE1134UR88) 
reported warnings on ports 7/1-7/3 (Unknown) due to BE2 Arbiter experienced an error 
in device 65 (device error 0xc410d613)
2008 Jul 15 19:39:30 fcd95c41 %MODULE-4-MOD_WARNING: Module 8 (serial: JAE1134UOTD) 
reported warnings on ports 8/1-8/3 (Unknown) due to BE2 Arbiter experienced an error 
in device 65 (device error 0xc410d613)
2008 Jul 15 19:39:35 fcd95c41 %XBAR-5-XBAR_STATUS_REPORT: Module 12 reported status 
for component 88 code 0x40240015.
2008 Jul 15 19:39:35 fcd95c41 %MODULE-2-MOD_DIAG_FAIL: Module 12 (serial: JAE1136VU6L) 
reported failure on ports 12/1-12/24 (Fibre Channel) due to Fatal runtime Arb error. 
(DevErr is bitmap of failed modules) in device 88 (device error 0x800)
"show logging onboard" will show log similar to the one below for the reloaded module:
Logging time: Tue Jul 15 19:39:28 2008
machine check: process swapper (0), jiffies 0x744af3a4
Free pages in zone[0]:0x4a70,zone[1]:0x0,zone[2]:0x0
Stack: c000dd58 c001eefc c000b2c4 c000ae98 d2060e10 c003d7a4 c00f869c c0045cdc
d196c584 d196d100 c000c31c c000c3e4 c000ae90 c000c910 c000c924 c0008948 c01ca610 
c0000394
...................
..................

Workaround: None. The chance of a module reload occurring again on the same module is very rare. Therefore, continued use of the module is acceptable.

A software workaround for this issue exists in SAN-OS Release 3.3.(2) and NX-OS Release 4.(1b). Upgrading to one of those releases will help decrease instances of modules reloads.

CSCin95789

Symptom: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces on a Windows platform, the configuration web page might not show that the interface has been selected for traffic capture even though traffic capture on that interface is enabled.

Workaround: Check the logs to clarify that the correct interface has been selected.

CSCse31881

Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.

Workaround: Before downgrading, remove the IPFC interface on the module and then recreate the IPFC interface after the downgrade is complete.

CSCse47687

Symptom: If IP ACLs are applied to any IP Storage Gigabit Ethernet port, implicit deny does not take effect.

Workaround: Configure explicit deny on the port.

CSCsg19148

Symptom: Time zone changes that are executed on an MDS switch do not take effect on the 12-port, 24-port, and 48 port 1-Gbps/2-Gbps/4-Gbps Fibre Channel modules, and on the 4-port 10-Gbps module. This issue occurs in SAN-OS Releases 3.0(1), 3.0(2), 3.0(2a), and 3.0(3).

Time zone changes that are executed on an MDS switch do not take effect on the 16-port or 32-port 1-Gbps/2-Gbps module, on the 4-port or 8-port Gigabit Ethernet IP services module, the MPS-14/2 module, and on the SSM. This issue occurs in SAN-OS Release 3.0(3).

This issue has no effect on functionality. However, debug messages and syslogs from the MDS switching modules have incorrect timestamps if the time zone is configured on an MDS switch.

Workaround: None.

CSCsg19303

Symptom: Graceful shutdowns of ISLs are not supported for IVR traffic.

Workaround: Increase the FSPF cost on the link before it is shut down, so that traffic will flow through an alternate path.

CSCsi66310

Symptom: The management port on MDS switches supports one user-configured IPv6 address, but does not support autoconfiguration of an IPv6 address in Cisco SAN-OS Release 3.2(1).

Workaround: None.

CSCsj24904

Symptom: On a Gigabit Ethernet interface on an MDS MSM-18/4 module, shut the interface before removing its IP address so that configuration changes on the interface can take effect. This applies only to the Gigabit Ethernet ports in slot 1 of the MDS 9222i switch and the MDS 9216i switch.

Workaround: Always shut the interface using the shutdown command before removing the IP address and making configuration changes.

CSCsj72666

Symptom: In certain conditions, an MDS switch may not be able to determine the FC4-type of certain targets. This causes the targets to be listed in the hosts section during a Cisco SME tape group or tape device configuration.

Workaround: Issue the discover scsi-target vsan vsan-id fcid fcid command to re-discover the FC4-type of the targets. A Cisco SME tape group or tape device configuration will now list the targets correctly.

CSCsk06186

Symptom: In rare situations, on an MDS 9513 director switch, an upgrade fails when a standby supervisor does not come up to a state that the installer recognizes. As a result, the standby supervisor is reloaded to recover and the system runs the older configuration version.

Workaround: Perform the upgrade again.

CSCsk35725

Symptom: Fabric Manager takes 2 to 3 minutes to bring up the DMM job creation wizard in a setup with 25 switches, 400 enclosures, and 2400 entries in the name server.

Workaround: None.

CSCsk35951

Symptom: In a configuration with a PortChannel with FCIP members and write acceleration in use, if IVR NAT is enabled on one end of the PortChannel and not enabled on the other end, then traffic over the FCIP tunnel might fail.

Workaround: Enable IVR NAT on both ends of the PortChannel or disable it on both ends.

CSCsk49309

Symptom: IPv6 duplicate address detection (DAD) may not always works for the management port.

Workaround: None.

CSCsk63929

Symptom: If DMM is provisioned on the SSM and you downgrade to a Cisco MDS SAN-OS release that does not support DMM, the configuration persists and the GUI and CLI show DMM as a provisioned application.

Workaround: Manually remove the DMM configuration from the switch before downgrading to a Cisco MDS SAN-OS release that does not support DMM, such as downgrading from SAN-OS Release 3.2(1) to SAN-OS Release 3.1(3). If you forget to remove the configuration before the downgrade, power off the module and purge the configuration on the SSM module by entering the following commands:

switch(config)# poweroff module slot
switch#
purge module slot running-config

CSCsk87502

Symptom: If an NASB configuration in a VSAN is destroyed while a target discovery is pending, the NASB process fails. Issue the show nasb vsan x command on the SSM to view the target discovery in the Pending state.

Workaround: Reload the SSM.

CSCsk87614

Symptom: When NASB is enabled in a VSAN, all targets that are visible in that VSAN are discovered by NASB. If a new target is added to the VSAN, NASB does not automatically discover the new target.

Workaround: To discover the new target, reload the SSM or disable and re-enable NASB in the VSAN.

CSCsk93834

Symptom: In rare situations during a storage-based online data migration job, the user might not be able to destroy the job if the following sequence of events occurs:

1. A storage-based data migration job is executing.

2. A port flap occurs on the server and the server HBA port goes down.

3. The storage-based data migration job continues executing until it completes.

4. The user issues the dmm module module-id job job-id destroy command to delete the storage-based data migration job, but the delete fails.

Workaround: Reload the SSM.

CSCsk95241

Symptom: If you use JDK instead of JRE on Solaris, you might encounter a problem trying to install Device Manager from a web browser. This can happen because the installer heap limit of 256 MB is not sufficient.

Workaround: If you have this problem, save the jnlp link as file, increase the heap limit to 512 MB, and run javaws element-manager.jnlp at the shell prompt.

CSCsl12130

Symptom: After a disruptive downgrade or upgrade between SAN-OS Release 3.2(2c) and Release 3.2(1a), issuing a no shutdown command on a Cisco SME interface fails. When issuing the install all command to perform the downgrade process, a warning is issued that indicates that the downgrade will be disruptive if Cisco SME is enabled.

Workaround: Disable Cisco SME before proceeding with the downgrade process. If you perform a disruptive downgrade, then issue the purge module slot running-config command for the MSM-18/4 modules where Cisco SME is configured after the downgrade is complete.

CSCsl12611

Symptom: Devices attached on a remote McData switch do not show a correct physical connection on the correct port in Fabric Manager. This occurs because the registered devices in the McData nameserver are shifted by 4 from its actual physical port and Fabric Manager looks at this port address from the nameserver to locate the physical port.

Workaround: None.

CSCsl15511

Symptom: On the MDS 12-port, 24-port, and 48-port 4-Gbps Fibre Channel switching modules, and on the 4-port 10-Gbps Fibre Channel switching module for downgrades from 3.2(2c) to lower versions, if fcdomain persistency is disabled, F ports may not come up after a shutdown or no shutdown or a link flap.

Workaround: Shut the F port, enable and disable fcdomain persistency for that VSAN, and then bring up the F port.

CSCsl17944

Symptom: During an MDS 9222i switch reload, the connection from the management port (mgmt0) to the Gigabit Ethernet interface goes down. When the connection comes back up, the Gigabit Ethernet interface doesn't go into forwarding mode until 30 seconds later. The Fabric Manager server is not able to communicate to the MDS 9222i switch through SNMP during this 30 second window.

Workaround: If the switch is in the Cisco Ethernet switch family, configure port-fast to resolve the issue. On Ethernet switches from other vendors, apply a similar configuration mode.

CSCsl31087

Symptom: In DMM, if a server I/O to a LUN fails during data migration, that session is marked as failed. The DMM migration job is then moved to a Failed state when the remaining sessions are complete. Such a failed migration job can be scheduled for a restart. If such a failed migration job is scheduled to start in less than 5 minutes from the time of scheduling, and another server I/O to a session LUN fails in that 5 minute window, the migration job will move from a Scheduled state to a Failed state. An administrator has the option to start the job immediately or schedule it again. This problem does not happen if an administrator schedules the migration job to start more than 5 minutes from the time of scheduling.

Workaround: Schedule the data migration job to start more than 5 minutes from the time of scheduling.

CSCsl33763

Symptom: In Cisco SME, tape device names can not include special characters (such as hyphens or underscores). This will cause future tape device creations for a tape group to fail.

Workaround: Use only alpha-numeric values for tape device names.

CSCsl34922

Symptom: Dual-fabric DMM migration jobs can not have one fabric running Release 3.2(1a) and a peer fabric running Release 3.2(2c) due to a signal message change. This may cause unexpected results during a DMM migration job validation, creation, start, and so on.

Workaround: Run both fabrics with the same software image.

CSCsl65951

Symptom: Using Fabric Manager Release 3.2(2), an error is displayed in the creation wizard. This occurs when an enclosure spans multiple fabrics and not all fabrics are managed and when the Data Migration Wizard is used to create a job with that enclosure as the existing storage (selecting all ports listed in that enclosure).

Workaround: Put the ports you plan to use as the existing storage in the migration into a separate enclosure, and use that enclosure in the wizard selection.

CSCsm08837

Symptom: When an IVR-enabled MDS switch with an empty device alias database, attempts to join a fabric which has approximately 7000 device aliases, the device alias merge fails. In this situation, the following occurs:

During the merge process between local and remote switches, the remote device alias database is received on the local switch. The local switch validates those device aliases with SAP 110 (which is IVR).

Since all 7000 aliases could not be sent in a single MTS message, the aliases are fragmented into 5 messages.

While IVR requires approximately 20 seconds to process each fragment, effectively it takes around 100 seconds to process all 5 messages.

Because DDAS has a timeout of around 60 seconds, the merge is rejected.

The merge process is retried after few minutes and the process repeats. Then finally failed.

Workaround: Enable device alias CFS distribution before enabling IVR.

CSCsm56190

Symptom: When copying SAN-OS Release 3.2(3a) from an ftp server to slot0 or to bootflash, which has enough free space, the following message is displayed:

2008 Feb 4 15:47:13 dcbu-m9509-196-D2 %USER-2-SYSTEM_MSG:

<<%PLATFORM-2-PFM_LOW_MEMORY_CONDITION>> Module 6 is running low on memory. 98 percent used

When SAN-OS 3.2(3a) is copied, system memory is used to keep temporary files. The page-cache memory is used and is not reclaimed until the memory becomes very low. This occurs when a large number of files are copied to the bootflash.

Workaround: A system switchover is required to prevent the affects of low system memory.

CSCso63465

Symptom: FCP-CMD (for example, Inquiry) frames targeted to LUN 0x45F0 or LUN 0x50F0 are dropped by an MDS switch when traffic flows (egresses) thru Generation 2 modules. LUN 0x45F0 corresponds to HPUX's Volume Set Address <VBUS ID: 0xB, Target ID: 0xE, LUN: 0x0>.

Workaround: Do not use LUN 0x45F0 and LUN 0x50F0 when Generation 2 modules are present in the fabric.

CSCsi56167

Symptom: The response time shown in the output of a ping ip-address command may not be accurate if there is an MDS MSM-8/4 in the path.

Workaround: Use the ips measure-rtt command to measure the round trip time.

CSCsk91974

Symptom: When you issue the show tech-support sme or the show klm internal isapi_scsi command after attaching to a module, you may see this error message: cat: write error: Bad address. This issue does not affect the actual tech-support log.

Workaround: None.

CSCsk73654

Symptom: In certain tape libraries, the tape drives are exported as LUNs. If these target ports are already a part of a Cisco SME configuration and new tape drives are added as LUNs, the new tape drives will not be discovered during a Cisco SME tape group or tape device configuration.

Workaround: Perform a rescan at the host level or a flap of the target port to allow Cisco SME to rediscover these newly added tape drives.

CSCsk43927

Symptom: The following Fabric Manager client components that use SSH and Telnet do not work well with NAT:

DMM storage job creation

Cisco SAN-OS software upgrade

Zone activation

Workaround: None.

CSCsm13002

Symptom: In rare cases, if a READ command issued by Cisco SME for media identification is dropped or lost, the tape is marked as a clear-text tape. Subsequently, a CHECK_CONDITION with ILI is returned when a READ is issued by the host. This can cause a backup application to mark the tape as read-only.

Workaround: Unmount and remount the tape from the backup application to resolve this issue.

CSCsm15874

Symptom: In rare cases, when Cisco SME attempts to perform a tape device discovery of the backend tapes, a SCSI command can stall. This may cause Cisco SME to remain in the device discovery phase.

Workaround: Reload the module.

CSCsm17768

Symptom: There is a observable performance drop for backup and restore when Cisco SME is introduced between a host and tape due to the increased latency.

Workaround: None.

CSCsm18303

Symptom: In certain cases with the Tape Recycle policy enabled in Cisco SME, a new key is generated when a tape is recycled and the old key is not purged.

Workaround: Manually purge the older version of the key.

CSCso04862

Symptom: In Fabric Manager, you may not be able to log in to an unlicensed fabric because more than one user is logged in or a user clicks the login button multiple times during startup. This occurs when the Fabric Manager Server has been restarted and multiple login attempts stop the start up process.

Workaround: When the Fabric Control panel is open, click the Clients tab and clear all users except the last logged in user.

CSCsq74312

Symptom: After a 24-port 4-Gbps Fibre Channel module was replaced by a 12-port 4-Gbps Fibre Channel module on a switch with a Supervisor 2 module, the running configuration and the startup configuration were different.

Workaround: Purge the entries by inserting a new module with an equal number or more ports than are present on the module being replaced.

Related Documentation

The documentation set for the Cisco MDS 9000 Family includes the following documents. To find a document online, use the Cisco MDS SAN-OS Documentation Locator at: http://www.cisco.com/en/US/products/ps5989/products_documentation_roadmap09186a00804500c1.html.
For information on IBM TotalStorage SAN Volume Controller Storage Software for the Cisco MDS 9000 Family, refer to the IBM TotalStorage Support website: http://www.ibm.com/storage/support/2062-2300/

Release Notes

Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Releases

Cisco MDS 9000 Family Release Notes for Storage Services Interface Images

Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images

Compatibility Information

Cisco MDS 9000 SAN-OS Hardware and Software Compatibility Information

Cisco MDS 9000 Family Interoperability Support Matrix

Cisco MDS SAN-OS Release Compatibility Matrix for IBM SAN Volume Controller Software for Cisco MDS 9000

Cisco MDS SAN-OS Release Compatibility Matrix for Storage Service Interface Images

Regulatory Compliance and Safety Information

Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family

Hardware Installation

Cisco MDS 9500 Series Hardware Installation Guide

Cisco MDS 9200 Series Hardware Installation Guide

Cisco MDS 9216 Switch Hardware Installation Guide

Cisco MDS 9100 Series Hardware Installation Guide

Cisco MDS 9124 Multilayer Fabric Switch Quick Start Guide

Cisco MDS 9020 Fabric Switch Hardware Installation Guide

Cisco Fabric Manager

Cisco MDS 9000 Family Fabric Manager Quick Configuration Guide

Cisco MDS 9000 Family Fabric Manager Configuration Guide

Cisco MDS 9000 Fabric Manager Online Help

Cisco MDS 9000 Fabric Manager Web Services Online Help

Command-Line Interface

Cisco MDS 9000 Family Software Upgrade and Downgrade Guide

Cisco MDS 9000 Family CLI Quick Configuration Guide

Cisco MDS 9000 Family CLI Configuration Guide

Cisco MDS 9000 Family Command Reference

Cisco MDS 9000 Family Quick Command Reference

Cisco MDS 9020 Fabric Switch Configuration Guide and Command Reference

Cisco MDS 9000 Family SAN Volume Controller Configuration Guide

Intelligent Storage Networking Services Configuration Guides

Cisco MDS 9000 Family Data Mobility Manager Configuration Guide

Cisco MDS 9000 Family Storage Media Encryption Configuration Guide

Cisco MDS 9000 Family Secure Erase Configuration Guide - For Cisco MDS 9500 and 9200 Series

Troubleshooting and Reference

Cisco MDS 9000 Family Troubleshooting Guide

Cisco MDS 9000 Family MIB Quick Reference

Cisco MDS 9020 Fabric Switch MIB Quick Reference

Cisco MDS 9000 Family SMI-S Programming Reference

Cisco MDS 9000 Family System Messages Reference

Cisco MDS 9020 Fabric Switch System Messages Reference

Installation and Configuration Note

Cisco MDS 9000 Family SSM Configuration Note

Cisco MDS 9000 Family Port Analyzer Adapter Installation and Configuration Note

Obtaining Documentation, Obtaining Support, and Security Guidelines

For information on obtaining documentation, obtaining support, providing documentation feedback, security guidelines, and also recommended aliases and general Cisco documents, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: