Cisco Unified IP Conference Station 7936 Administration Guide
Technical Specifications for the Cisco Unified IP Conference Station 7936
Downloads: This chapterpdf (PDF - 148.0KB) The complete bookPDF (PDF - 1.95MB) | Feedback

Technical Specifications for the Cisco Unified IP Conference Station 7936

Table Of Contents

Technical Specifications for the Cisco Unified IP Conference Station 7936

Physical and Operating Environment Specifications

Cable Specifications


Technical Specifications for the Cisco Unified IP Conference Station 7936


This appendix describes the technical specifications for the Cisco Unified IP Conference Station.

Physical and Operating Environment Specifications

Specification
Value or Range

Operating temperature

0°C to 40°C (32° to 104°F)

Operating relative humidity

20% to 85% (non-condensing)

Storage temperature

-30°C to 55°C (-22° to 131°F)

Height

31.5 cm (12 1/2 in.)

Width

30.2 cm (12 in.)

Depth

5.7 cm (2 1/4 in.)

Weight

0.8 kg (1 3/4 lb.)

Power

AC/DC adapter (100-240 V~, 50-60 Hz, 500 mA)

Power Interface Module (PIM)

Country Cord (orderable)

Conference Room Coverage

20 ft. by 30 ft. (with external microphones)

Audio Range

300Hz to 3500Hz (narrow band support)

Loudness

86.5dB at 0.5 meters

Cables

One 6-ft. CAT 5 cable

One 25-ft. CAT 5 cable

Cable Distance Requirements

As supported by the Ethernet Specification, each Conference Station must be within 100 meters (330 feet) of a wiring closet.


Cable Specifications

Keyed RJ-45 plug for the 25-ft. CAT 5 cable connection on the bottom of the IP Conference Station unit

Keyed RJ-45 plug for the 25-ft. CAT 5 cable connection on the PIM

RJ-45 plug for the 6-ft. CAT 5 cable connection on the PIM

30-volt power connector for power connection on the PIM