Release Notes for Cisco UCS C-Series Software, Release 1.4(1)

  • Viewing Options

  • PDF (273.0 KB)
  • Feedback

Table Of Contents

Release Notes for Cisco UCS C-Series Software, Release 1.4(1)

Contents

Introduction

Hardware and Software Interoperability

Firmware Files

Host Upgrade Utility

System Requirements

Updating the Firmware

Features in this Release

Hardware Features

SNMP

Supported Storage Controllers

BIOS/Hardware

Upgrading BIOS and CIMC firmware

Resolved Caveats

Known Behaviors

Open Caveats

Caveats from Previous Releases

Release 1.3(2d)

Release 1.3(1c)

Release 1.2(2d)

Release 1.1.(2)

Release 1.1(1)

Release 1.0(2)

Release 1.0(1d)

Release 1.0(1)

Documentation Updates

Active Directory

Related Documentation

Obtaining Documentation and Submitting a Service Request


Release Notes for Cisco UCS C-Series Software, Release 1.4(1)


First Published Date: Sep 15, 2011
Part Number: OL-25724-01

This document describes the new features, system requirements, open caveats and known behaviors for C- series software release 1.4(1) including Cisco Integrated Management Controller software and any related BIOS, firmware, or drivers. Use this document in conjunction with the documents listed in the "Related Documentation" section.


Note We sometimes update the documentation after original publication. Therefore, you should also review the documentation on Cisco.com for any updates.


Table 1 shows the online change history for this document.

Table 1 Online History Change 

Part Number
Revision
Date
Description

OL-25724-01

A0

September 15, 2011

Created release notes for Release 1.4(1c).

B0

October 24, 2011

Updated release notes for Release 1.4(1e)


Contents

This document includes the following sections:

Introduction

Features in this Release

Resolved Caveats

Known Behaviors

Open Caveats

Caveats from Previous Releases

Release 1.3(1c)

Release 1.2(2d)

Release 1.1.(2)

Release 1.1(1)

Release 1.0(2)

Release 1.0(1d)

Release 1.0(1)

Documentation Updates

Related Documentation

Obtaining Documentation and Submitting a Service Request

Introduction

Cisco® UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total cost of ownership (TCO) and increase business agility. Designed to operate both in standalone environments and as part of the Cisco Unified Computing System™1, the series employs Cisco technology to help customers handle the most challenging workloads. The series incorporates a standards-based unified network fabric, Cisco VN-Link virtualization support, and Cisco Extended Memory Technology. It supports an incremental deployment model and protects customer investments with a future migration path to unified computing.

The Cisco UCS C250 Extended-Memory Rack-Mount Server is a two-socket, two-rack-unit (2RU) rack-mount server featuring patented Cisco Extended Memory Technology. It is designed to increase performance and capacity for demanding virtualization and large-data-set workloads. It also can reduce the cost of smaller memory footprints. This server is built for virtualized workloads in enterprise data centers, service provider environments, and virtual desktop hosting. The system also helps increase performance for large-data-set workloads, including database management systems and modeling and simulation applications. Applications that are memory bound today will benefit by the 384 GB of addressable memory that the Cisco UCS C250 server offers.

The Cisco UCS C210 General-Purpose Rack-Mount Server is a general-purpose, two-socket, two-rack-unit (2RU) rack-mount server housing up to 16 internal small form-factor (SFF) SAS or SATA disk drives for a total of up to 32 terabytes (TB) of storage. The Cisco UCS C210 server is designed to balance performance, density, and efficiency for workloads requiring economical, high-capacity, reliable, internal storage. Based on quad-core Intel® Xeon® 5500 or 5600 series processors, the server is built for applications including virtualization, network file servers and appliances, storage servers, database servers, and content-delivery servers.

The Cisco UCS C200 High-Density Rack-Mount Server is a high-density server with balanced compute performance and I/O flexibility. This price-to-performance optimized two-socket, one-rack-unit (1RU) rack-mount server is designed to balance simplicity, performance, and density for web infrastructure and mainstream data center, small-office, and remote-office applications. Its single-rack-unit size makes it useful for service providers offering dedicated or multi-tenant hosting, and its economical price makes it well suited to the appliance market.

C-series servers are capable of standalone management using Cisco Integrated Management Controller (CIMC), which is an integration of the service processor hardware and the CIMC firmware. CIMC has a Web GUI and a CLI mode.

The Cisco UCS C200 M2 Small Form Factor (SFF) server is a factory-configurable option that is an alternate to the existing Cisco UCS C200 M2 Large Form Factor (LFF) server.

The LFF version of the server can contain up to four 3.5-inch LFF hard drives or solid state drives. If a customer orders the new SFF version of the server, the chassis is configured with a drive backplane and front drive bays that can contain up to eight 2.5-inch SFF drives. The drive bays and backplane are factory-configurable, but are not supported as field-configurable.

The SFF server also allows configurable selection of front-panel control modules. Customers can choose the standard control panel module or an optional DVD-drive module. These two modules are field-replaceable and interchangeable with the supplied cables.

In addition, 2.5-inch drives have been qualified as configurable options for the SFF server. The RAID controller options have also been qualified for the SFF server (LSI MegaRAID 9280-4i4e and LSI 1068-based mezzanine card).

Hardware and Software Interoperability

For detailed information about storage switch, operating system, adapter, adapter utility, and storage array interoperability, see the Hardware and Software Interoperability Matrix for your release located at:

http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

Firmware Files

The C-Series software release 1.4(1) includes the following software files:

Table 2 Files in this release

CCO Software Type
File name(s)
Comment

Unified Computing System (UCS) Server Firmware

ucs-c200-huu-1.4.1c.iso

ucs-c250-huu-1.4.1e.iso

Host Upgrade Utility

Unified Computing System (UCS) Drivers

ucs-cxxx-drivers.1.4.1.iso

Drivers

Unified Computing System (UCS) Utilities

ucs-c2xx-utils-linux.1.4.1.iso

ucs-c2xx-utils-vmware.1.4.1.iso

ucs-c2xx-utils-windows.1.4.1.iso

Utilities

Unified Computing System (UCS) Adapter Firmware

ucs-cxxx-fw.1.4.1.iso

Third-Party Firmware



Note Always upgrade both the BIOS and the CIMC from the HUU ISO. Do not upgrade individual components (only BIOS or only CIMC), since this could lead to unexpected behavior.


Host Upgrade Utility

The Cisco Host Upgrade Utility (HUU) is a tool that upgrades the following firmware:

Cisco Integrated Management Controller (CIMC)

System BIOS

LAN on motherboard (LOM)

RAID Controllers (LSI storage controllers)

Cisco UCS P81E Virtual Interface Card (VIC)

Broadcom PCIe adapters

5709 Dual and Quad port adapters

57711 Dual port adapter

57712 Dual port adapter

Intel® PRO/1000 PF Quad Port Server Adapter

In addition, this utility now supports the following options:

Download ISO images for a selected platform on a Windows operating system.

Recover a corrupt BIOS in the EFI shell.

The image file for the firmware is embedded in the ISO. The utility displays a menu that allows you to choose which firmware components to upgrade. For more information on this utility see:

http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html

Starting with this 1.4 release, separate ISO images of Host Upgrade Utility are available for different server platforms.

The ISO image is now named as ucs-<server_platform>-huu-<version_number>.iso.

The Cisco Host Upgrade Utility contains the following files:

Table 3 Files in ucs-c200-huu-1.4.1c.iso

Server(s)
Component
Version

C200M1

C210M1

C200M2

C210M2

C210M2 SFF

CIMC

1.4(1a)

BIOS

1.4.1

UCS P81E

1.6(1c)

RAID Controllers

 

1064

1.32.04.00

1068

1.32.04.00

8708

1.40.272-1225

9260-4i

2.120.133-1322

9260-8i

2.120.133-1322

9280-4i4e

2.120.13-1133

LOM

 

Intel-82576

1.4

PCIe Adapters

 

Broadcom 5709-Dual-Port

5.2.3

Broadcom 5709-Quad-Port

5.2.3

Broadcom 57711-Dual-Port

5.2.51 - aa0.406

Broadcom 57712-Dual-Port

A1213GT6441.1

Intel® PRO/1000 PF Quad Port Server Adapter

1.3.32


Table 4 Files in ucs-c250-huu-1.4.1e.iso

Server(s)
Component
Version

C250M1

C250M2

CIMC

1.4(1d)

BIOS

1.4.1c.0

UCS P81E

1.6(1c)

RAID Controllers

 

3081

1.32.04.00

9261

2.120.133-1322

LOM

 

Broadcom 5709

C250T6045-2.0

PCIe Adapters

 

Broadcom 5709-Dual-Port

5.2.3

Broadcom 5709-Quad-Port

5.2.3

Broadcom 57711-Dual-Port

5.2.51 - aa0.406

Broadcom 57712-Dual-Port

A1213GT6441.1

Intel® PRO/1000 PF Quad Port Server Adapter

1.3.32


System Requirements

The management client must meet or exceed the following minimum system requirements:

Sun JRE 1.6.0_14 or later

Microsoft Internet Explorer 6.0 or higher, Mozilla Firefox 3.0 or higher

Microsoft Windows 7, Microsoft Windows XP, Microsoft Windows Vista, Apple Mac OS X v10.6, Red Hat Enterprise Linux 5.0 or higher operating systems

Updating the Firmware

Use the Host Upgrade Utility to upgrade the C-Series firmware. Host Upgrade Utility can upgrade the following software components:

BIOS

CIMC

LAN on Motherboard Settings

RAID Controller Firmware

Select PCIe adapter Firmware

All firmware should be upgraded together to ensure proper operation of your server.

Features in this Release

This section briefly describes the new features introduced in this release:

Support for Cisco UCS CIMC XML API.

The CIMC XML API is a programmatic interface to the Cisco Integrated Management Controller (CIMC) in a standalone C-Series server.

The CIMC XML API is implemented to behave similar to the UCSM XML API. Customers familiar with using the UCSM XML API can reuse the same client development techniques and tools to integrate with a C-Series server.

The CIMC XML API only implements a subset of the methods and functionality of the UCSM XML API.

The CIMC inventory, state and configuration information is modeled in a hierarchical tree structure known as the Management Information Tree (MIT).

OS support for KVM and Virtual Media:

64-bit Linux Distributions

RHEL 5

SLES 11

64-bit Windows

Windows 7

Windows 2008 R2

MAC OS-X 10.6 (32/64-bit)

Enhanced Active Directory support:

Group Authorization and searching nested groups

Allow for multiple Domain Controllers

Allow for multiple Global Catalogs

Enhanced SNMP Support:

Inventory and fault information delivery for fan, power supply, CPU, memory, storage physical drive, storage virtual drive, battery back-up unit for the storage controller, and supported storage controllers.

SNMP V1, V2c and V3 authentication.

MD5/SHA authentication along with AES/DES encryption available for SNMP V3 security.

General CIMC Management enhancements:

Access to LAN on Motherboard MACs.

Support for configuration of FCoE over NIV for UCS P81E Virtual Interface Card.

Support for VM FEXs on P81E Virtual Interface Card.

Control of Hard drive locator LED (MegaRAID enabled adapters only).

Host Upgrade Utility:

Per platform Host Upgrade Utility ISO.

Support for firmware upgrades on plug-in PCIe adapter cards

Broadcom 5709-Dual-Port

Broadcom 5709-Quad-Port

Broadcom 57711-Dual-Port

Broadcom 57712-Dual-Port

Intel® PRO/1000 PF Quad Port Server Adapter

Hardware Features

The following platforms are supported in release 1.4:

UCS-C200

UCS-C210

UCS-C250

SNMP

The supported MIB definition for release 1.4(1) can be found at the following link: ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-C-supportlist.html


Note The above link is incompatible with IE 9.0.


Supported Storage Controllers

SNMP supports the following storage controllers:

9260-4i

9260-8i

9261-8i

9240-8i

9280-4i4e

BIOS/Hardware

Symptom    Cisco is introducing a new generation of SATA 2.5-inch hard drives which are for the first time compatible with the new SATA Revision 3.0 standard capable of 6 Gbit/s. In particular these hard drives are SATA 500 GB (A03-D500GC3) and 1 TB (A03-D1TBSATA). Due to legacy design constraints in certain Generation M2 C-Series servers, the faster 6 Gbit/s link speeds may not always be possible in all servers. However, in those cases, the link speeds will properly negotiate the link back to the Revision 2.0 standard capability of 3 Gbit/s. This operation is seamless to the user.

Workaround   This is a known behavior, as follows:

The UCS C200 M2 SFF server supports these drives at full 6Gbit/s speeds.

The UCS C210 M2 server guarantees support of these drives at a minimum of 3Gbit/s speeds.

The UCS C250 M2 server guarantees support of these drives at a minimum of 3Gbit/s speeds.

The UCS C460 M2 server supports these drives at full 6Gbit/s speeds.


Note In some cases, you may find that some or all links have negotiated to the higher 6Gbit/s speeds. Those links that do, will operate properly at that speed.


Upgrading BIOS and CIMC firmware


Caution When you upgrade the BIOS firmware, you must also upgrade the CIMC firmware from the same HUU ISO, or the server may not boot. Do not power off the server until the BIOS and CIMC firmware are updated.

Cisco provides the Cisco Host Upgrade Utility to assist you in upgrading the BIOS, CIMC, LOM, LSI storage controller, and Cisco UCS P81E Virtual Interface Card firmware to compatible levels.

The correct and compatible firmware levels for your server model are embedded in the utility ISO.

To use this utility, start with the Cisco Host Upgrade Utility User Guide, which includes the instructions for downloading and using the utility ISO. Select the correct guide for your desired firmware version from this URL:

http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html

Cisco Host Upgrade Utility User Guide for Release 1.2(x)

Cisco Host Upgrade Utility User Guide for Release 1.3(x)

Cisco Host Upgrade Utility User Guide for Release 1.4(x)

Resolved Caveats

This section lists the resolved caveats for the 1.4(1x) release, where `x' indicates the revision character.

The following caveat was resolved in the 1.4(1e) release for C250 platform:

BIOS

Symptom    Attempt to reset the C250 server from the BMC causes spurious ECC uncorrectable errors.

Workaround   Do not reset the server from the BMC, instead power down and power up the server. (CSCtt35212)

The following caveats were resolved in the 1.4(1) release:

BIOS

Symptom    If you enter into the LSI Option ROM Configuration utility WebBIOS, by pressing <CNTRL-H> during boot, the BIOS boot order changes. So after exiting the WebBIOS and rebooting, the system might not boot in the same order as expected previously.

Workaround   After exiting the WebBIOS (which reboots the system anyway), update the Boot order by entering BIOS Setup. Follow these steps:


Step 1 Press F2 to enter the BIOS Setup.

Step 2 Goto Boot Option Tab, select "Hard Disk Order" and update the boot order as required.

Step 3 Update the Boot Option #1, #2, and so on.

Step 4 Save and exit (F10). (CSCta56788)


Symptom    When VT-UTF8 is selected as a terminal type in the BIOS Setup, junk characters are seen on the terminal.

Workaround   Do not select the VT-UTF8 terminal type, instead use the VT100 default mode. (CSCtb25124)

CIMC

Symptom    Immediately after switching off the main CPU in C460 M1 rack server, the CIMC becomes unresponsive.

Workaround   Restart the CIMC. (CSCtl56864)

Symptom    On some UCS C210 servers, FAN4 and FAN5 TACH sensors are showing status as CRITICAL and the speed is 0.

Workaround   None. (CSCtr11881)

Symptom    BIOS configuration is not saved in CIMC exported configuration.

Workaround   None. (CSCtl72671)

Symptom    Gradual memory leak over a period of time is seen in CIMC, which may lead to Out of Memory (OOM) scenario. This is observed when the SNMP feature is enabled.

Workaround   None. This has been resolved in 1.3(3) and 1.4(1). (CSCto53530)

Symptom    Disabling SNMP feature from Cisco CLI fails.

Workaround   Use WebGUI to disable SNMP feature. This is available in the page Admin->Communications services. (CSCtq28791)

Symptom    If you enter special characters for a VNIC name like "("or")" then a core is generated.

Workaround   Special characters should be assigned in quotes. For example, If assigning cd()() as the name of the VNIC, it should be enclosed in quotes in the GUI as "cd()()". (CSCto54995)

Symptom    Image files created by the Virtual Media subsystem are created in the user's desktop directory.

Workaround   There is no workaround. Currently image files are always created in the user's desktop directory. Once the image file is created a user can move it anywhere, but the creation process is currently in a fixed location. (CSCtk59127)

LOM

Symptom    C460 10GE LOM ports are not supported in RHEL 5.6. Broadcom netxtreme2-6.0.XX Linux drivers cannot be compiled in RHEL 5.6.

Workaround   Broadcom does not support RHEL5.6 in this release. (CSCtn17919)

KVM

Symptom    User sees out of date (without KVM and VM tabs) KVM/vMedia client windows.

Workaround   When running 1.3(1) software, if a KVM session is initiated, and the client does not have separate KVM and VM tabs, then it almost certainly indicates an older client is being run. The solution is to clear the java cache on the system. This is different than the browser cache. On Windows XP, follow these steps:


Step 1 Navigate to the Control Panel -> Java Control Panel.

Step 2 Click on the Settings button in the Temporary Internet Files panel.

Step 3 Click on the Delete Files button in the Temporary Files Settings popup box.

Step 4 Be sure to check the Applications and Applets checkbox and then click OK. (CSCtn41499)


Symptom    User is not allowed to choose file name when creating vMedia image files.

Workaround   The .img file created when using the vMedia "Create Image" feature is the same as the directory from which the contents are created with the ".img" extension added. Before creating the file, you can change the directory name to match what you would like the final file name to be. (CSCtk59152)

Known Behaviors

The following are the known behaviors found in the 1.4(1) release:

BIOS

Symptom    BIOS POST will generate "PCI out of resource" errors when more than three PCI cards are added to a server, and all the PCI cards may not function correctly once the server boots to an Operating System.

Workaround   Disable unused PCI card option in ROMs using BIOS setup or CIMC BIOS configuration page.

Symptom    Two CPU erroneously detected with different frequency after OS reboot. During boot the server may hang with the following message during BIOS post. Unrecoverable fatal error found. System will not boot until the error is resolved.

Workaround   Reset the server.

Symptom    On the C series servers with UCS P81E Virtual Interface Card, the system may hang during system boot (BIOS post).

Workaround   This happens only when more than two vNICs are set to bootable in UCS P81E Virtual Interface Card. Do not set more than two vNICs to be bootable in UCS P81E Virtual Interface Card.

Symptom    BIOS boot order may get corrupted when you try to set the boot order from CIMC.

Workaround   You can recover the boot order by configuring the boot order from CIMC with "EFI Shell" as the boot device. "EFI Shell" is provided as a boot option mainly for diagnostic and debugging purposes. This is the last option by default. In case, if it is needed to set "EFI Shell" as first boot device, then BIOS setup should be used to set the boot order.

Symptom    When BIOS recovery process is initiated to recover a corrupt BIOS, this process will alter the boot order.

Workaround   The boot order has to be reconfigured using BIOS setup after doing the BIOS recovery.

CIMC

Symptom    After Factory default, if the network cable is connected to management port 2. IP restored does not ping.

Workaround   We need to connect to management port 1, if we are trying to use factory defaults. CIMC will retain a DHCP IP on management port 1. So we will not loose connectivity to the machine.

Symptom    Occasionally when configuring a C-series rack server for in-band management (connecting to the management controller via the host LAN on Motherboard ports, or via a Cisco adapter port), rebooting the host will cause an existing vKVM session to drop.

Workaround   Use the dedicated CIMC ports for management connectivity. If that is not possible in your C-series server deployment, configure the switch ports to which the host is attached for fast spanning-tree recalculations. That can avoid the usual 30-second delay many switches impose when a port bounces before they re-run the spanning-tree calculation.

Symptom    After resetting a C250 M1 to factory defaults, if the network cable is connected to management port 2, the restored IP does not ping other addresses. Factory default mode is not supposed to be used for normal operation. If ethernet management port 2 is used it gets a static IP used by Cisco even if DHCP is enabled.

Workaround   Connect to management port 1 instead.

Symptom    SSH and HTTP both can be disabled. If both SSH and HTTP are disabled at the same time then you will loose the complete connectivity to CIMC.

Workaround   Do not disable SSH and HTTP at the same time. If disabled, to recover reset the factory default jumper on the board.

Symptom    CIMC becomes un-responsive when repeated WSMAN requests are sent.

Workaround   Multiple WSMAN requests timeout as current CIM object manager servers only support one request at a time. Send WSMAN requests in a staggered manner so that they do not time out.

Symptom    When downgrading from CIMC version 1.2 release to 1.1, CIMC is inaccessible.

Workaround   Check its current network settings through the CIMC Configuration Utility or set the CIMC network settings to default using the CIMC Configuration Utility and use default network settings for version 1.1.

vKVM/vMedia

Symptom    RHEL 4.8 does not detect the USB when mounted through virtual media.

Workaround   The kernel needs to be rebuilt with max_luns option set to 255 in modprobe.conf.

Symptom    Launching the KVM console with Microsoft Internet Explorer browser fails with the message "Internet Explorer was not able to open this Internet site. The requested site is either unavailable or cannot be found".

Workaround   From the Internet Explorer toolbar, select Tools -> Internet Options. The Internet Options dialog box will pop-up. Click the Advanced tab and uncheck the "Do not save encrypted pages to disk" option.

Symptom    Unable to launch KVM. While launching the KVM, the error message "Login Failed" is thrown and KVM Closed Automatically. This can occur in the following scenarios:

When you try to launch all the Maximum KVM sessions quickly (4 KVM session) and you can see that out of 4, 2 or 3 are failed with an error Message "Login Failed".

When launching single session of KVM, you might get an error message "Login Failed" and KVM is automatically closed.

Workaround   When the KVM launch is failed with an error message "Login Failed" then wait for 2-3 mins and then again relauch the KVM.

Symptom    Sometimes blank screen is seen on KVM after FW update.

Workaround   Clear Java cache from the control panel for Windows machine.

Symptom    The virtual mouse in the KVM console is difficult to use when installing SLES 11.

Workaround   Use a physical mouse instead of a virtual mouse when installing SLES 11.

Symptom    On C460, firmware update might fail with an error message "System update Package not found for the platform" or "Error string not found".

Workaround   Check if the SCU boot CD / ISO is mounted / mapped in vmedia.

Retry the update after making the SCU CD/ISO available.

Symptom    KVM and vMedia does not work with mismatched IE and JRE executables.

Workaround   Ensure that the matching JRE (and only the matching JRE) are installed. If a mismatched JRE is installed, it needs to be removed.

LSI

Symptom    ESX3.5 does not support LSI 9261-8i RAID Controller.

Workaround   Use the 8707 RAID adapter instead.

Symptom    System reboots when one or more Intel SSD 64GB drives are plugged in when the C-460 Server is up and running.

Workaround   If Intel 64GB SSD drives need to be used in the C-460 server, power down the system completely and gracefully and then plug in the drives. The drives are recognised by the Storage controller after power-on.

CLI

Symptom    In Power restore policy, a delay value is shown even if the delay type is random. In CLI, if the power policy is set to random, ideally delay value should not be shown.

Workaround   Due to CLI limitation delay value is shown. This must be ignored.

Misc

Symptom    Windows 2008 R2 installation fails with the following message: "The Computer restarted unexpectedly or encountered an unexpected error. Windows installation cannot proceed. To install Windows, click OK to restart the computer, and then restart the installation".

Workaround   Remove the Intel® PRO/1000 PF Quad Port Server Adapter for a successful windows install.

Symptom    The CLP command takes a long time to complete and/or other applications appear slow.

Workaround   The -l all option instructs CLP to traverse the entire sub tree. Due to the number of objects that must be queried, this command requires a long time to execute. To reduce the time and resources required, cd to the target(s) of interest and execute a show on the individual objects.

Symptom    Rx Errors or Rx FCS Errors reported by Ethernet vNICs.

Processor C3 or C6 Enabled in the BIOS and high rx traffic load. In this case the PCIE root complex occasionally stalls up to 100 microseconds which may cause the ingress packet buffers to fill, resulting in a partial (truncated) frame which is reported as an FCS error.

High traffic replication load to multiple vNICs assigned to the same uplink (For example, multiple vNICs in promiscuous mode). If receive traffic is replicated to multiple vNICs this may exceed the transfer ability of the adapter, resulting in the receive buffer filling. This may cause a truncated frame which will be reported as an FCS error.

Workaround   Enable per-priority pause on active COSes on the switch.

LOM

Symptom    Wake on LAN (WoL) Magic packet will not wake the system if they are sent to 10 GigE LOM SFP+ interfaces.

Workaround   Use 1 GigE LOM ports for WoL.

Symptom    C460 10GBaseT LOM port can not hold the link when the host is down (on standby power) and it is connected to a switch which does not support 1G or lower speed.

Workaround   C460 10GBaseT LOM does not support 10G speed on standby. If the BMC network mode is "Shared 10G" and the LOM port has to stay up on standby power, the port must be connected to a switch which supports 1G or lower speed and auto negotiation must be enabled.

Web UI

Symptom    While changing network mode to cisco card mode in IE, sometimes you might get an error as not able to parse the xml response.

Workaround   Update IE browser version 8.0.6001.18702 and above or use other browser clients like Firefox, or Chrome.

Symptom    The SEL Viewer agent in Windows 2003 might crash/stop when accessing SEL.

Workaround   This issue is caused only when a COM based service try to access the WMI namespace. Assign the service with the current account (administrator) privilege. To set the privileges, follow these steps:


Step 1 Open services console by typing "services.msc" in Run.

Step 2 Select the service with the name "Cisco UCS SEL Viewer Agent".

Step 3 Click on Log On tab.

Step 4 Change "Log on as" from "Local System Account" to "This account".

Step 5 Restart the service.


It is recommended to run SEL Viewer agent from an administrator account.

Utilities

Symptom    CIMC downgrade does not work. Firmware downgrade using the fwup utility older than ver 1.1.5 is causing the failure.

Workaround   Use the fwup utility above ver 1.1.5. This version of utility is available only in the software releases above 1.4.x.

Symptom    When you try to run other applications which uses the same IPMI driver used by SEL Viewer, SEL Viewer stops.

Workaround   None.

Symptom    All OEM events, severity, and other fields in SEL Viewer will be displayed as Unknown. For example, Microsoft Windows 2003 R2 or Windows 2006 with Microsoft IPMI driver installed logs OEM events not known by SEL Viewer utility.

Workaround   None.

Symptom    Unable to access SEL Viewer GUI. SEL Viewer may report CIMC unavailable.

Workaround   Verify whether firewall is enabled and the port on which SEL Viewer is running (default: 9099) is allowed through firewall.

Symptom    The SEL Viewer agent service stops in Windows when reloading SEL, while SEL is empty. This happens in the second attempt.

Workaround   Start the service named "Cisco UCS SEL Viewer Agent" manually through service control panel.

The following are the known behaviors found in the 1.3(2d) release:

CLI

Symptom    There's a message discrepancy between user interface and CLI when an invalid special character is entered.

Workaround   Special characters should be entered with double quotes to be considered a valid string.

The following are the known behaviors found in the 1.3(1c) release:

CIMC

Symptom    KVM console is blank after updating CIMC firmware from AP to BP.

Workaround   

Option 1: From control panel clear the cache of java and try performing the reproduction step.

Option 2: Move CIMC to 1.4(x) release.

vKVM/vMedia

Symptom    When you try to use virtual media to map both a .img file and a physical USB stick (pen/thumb drive), the following message (or a similar one) pops up: "Either Virtual media is detached or virtual media redirection for the selected virtual disk drive is already is in use by another user".

Workaround   The workaround is to only map one or the other drive at a time.

Symptom    When creating a vMedia image file, a popup with the following message is displayed, "Create Image Failed. An error occurred in the Image library".

Workaround   The image creation feature only supports image sizes up to 4 GB (32-bits) in size. Trying to create images from filesystems larger than that will result in an error. There is no direct workaround. Break data into smaller chunks, and represent each chunk as a separate image.

Symptom    When shutting down a vKVM session, you will notice a popup with the following message, "Closing this session will also close the locked virtual media session. Do you want to continue?"

Workaround   None. Click the "Yes" button.

The following are the known behaviors found in the 1.2(2d) release:

CIMC

Symptom    With maximum hardware acceleration in some Windows OS installs, the vKVM cursor disappears.

Workaround   If the slider is moved even one notch to the left of the maximum acceleration, then the remote cursor appears.

The following are the known behaviors found in the 1.2(1a) release:

BIOS

Symptom    After upgrading to BIOS version 1.2.1a.0, one of the two onboard LOMs may get disabled.

Workaround   After upgrading to BIOS version 1.2.1a.0, reboot the server, go to the BIOS setup screen, navigate to the Advanced -> PCI Configuration screen, and set the "Onboard Gbit NIC2" to enabled. Then save and exit the BIOS setup.

CIMC

Symptom    The CIMC Web GUI doesn't come up after certificate import. The browser displays the following Error message: Error Invalid Server Certificate. A request failed because the server's certificate was invalid.

Workaround   Provide different values for the corresponding fields for "Subject Information" and "Issuer Information" during the certificate import process.

Symptom    After using the WSMAN command the session displays the following error message: Error: Unable to create Resource Locator object.

Workaround   There is no workaround. This request is not valid. You will need to provide a valid target so that CIMC can return appropriate information.

Symptom    Occasionally IPMI LAN interfaces will become unresponsive (to the point of lost functionality) under stress.

Workaround   The workaround is not to use IPMI queries during times of high SOL traffic.

Symptom    The uboot version shows extra character after normal CIMC version.

Workaround   The extra character is displayed after updating to 1.2.x revisions of the firmware. This is a new feature added to the release and it specifies a specific uboot version.

Symptom    Two active media sessions observed in the webUI/CLI.

Workaround   Reset to default through the webUI or CLI so that the new changes take effect.

LSI

Symptom    When the installation of the LSI SNMP agent on a Windows OS is complete, an error message that reads as "Fatal Error" may be displayed, indicating an unsupported version of firmware is installed on the storage controller.

Workaround   The firmware version installed on the storage controller must be a supported version. To view the list of supported firmware versions for the controller, see: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

Symptom    When there are 8708 and 1064E LSI controllers on the same system, the product name of the 1064E controller is displayed as "UNUSED" on the MIB walk.

Workaround   Remove the 8708 LSI controller and place only the 1064E to view the product name in the MIB walk.

Open Caveats

This section lists the open caveats for the 1.4(1) release:

BIOS

Symptom    BIOS setup parameters configuration interface from CIMC does not validate runtime parameters of the system and also it is not aware of the interdependency between them. For example,

If the memory configuration does not support memory mirroring, then BIOS setup does not show mirroring as a setup option. However, CIMC would still show the option to set mirroring.

When the system is equipped with a 4 core CPU, BIOS setup option to disable the cores would only show upto 4 cores. However CIMC would still show the option upto 6 cores.

When SATA controller is disabled, BIOS setup will hide the options to set other SATA controller parameters. However CIMC would still show the other SATA controller parameters.

Workaround   Even though the options are shown and can be configured from CIMC, it does not create any side-effects, nor do any harm to the system. BIOS will handle them gracefully. (CSCtl21208)

Symptom    BIOS downgrade using the iFlash32 utility, from 1.4.x to the older version 1.2.x fails.

Workaround   Use the startup.nsh script available in the 1.2.x container for the downgrade. This script will execute the BIOS downgrade successfully. (CSCtr93601)

Symptom    When the BIOS parameters are configured from CIMC CLI or WebUI interfaces, the configuration might not take effect.

Workaround   Re-configure the BIOS parameters. (CSCtn46192)

CIMC

Symptom    When you reboot/upgrade the CIMC firmware through the WebGUI, the WebGUI will redirect to login page. When you try to login, you will get a message "session is already active, please logout to clear the existing session". You will get the same message, even after you logout, and login again.

Workaround   You must clear the cookies/cache to login successfully. (CSCts39518)

Symptom    The AES encryption field does not show the encryption level (128/256/ etc) on the Web UI and CLI.

Workaround   The SNMP V3 encryption key length must be clearly indicated. The SNMP agent supports AES - 128 bit encryption by default. (CSCtr31577)

Symptom    SNMP V1 test traps are sent even when V2 or V3 traps are enabled.

Workaround   There is no provision for V2 and V3 test traps in the present implementation of the SNMP agent. (CSCtr37876)

Symptom    SNMPV3 traps are not receiving in Net-SNMP receiver. When V3 settings are chosen for trap delivery, the SNMP trapd CLI utility fails to receive V3 traps.

Workaround   There is a possibility that the SNMP trap utility might not work for V3 authentication/privilege settings. (CSCtr83298)

Symptom    When "ipmitool sdr" command is entered at the command prompt, an unspecified error is observed.

[root@localhost ~]# ipmitool sdr

Get SDR xxxx command failed: Unspecified error

Workaround   None. (CSCtr99251)

Misc

Symptom    Ports on the N2XX-ABPCI02 do not come up after a reboot or power cycle when running Linux.

Workaround   Power cycle the server. (CSCtk66778)

LSI

Symptom    SNMP trap is not received when check consistency has failed. This issue is seen with certain firmware releases of the LSI Storage controller.

Workaround   Update the LSI storage controller firmware. (CSCtr90017)

LOM

Symptom    Broadcom adapters and LOMs based on BCM5709, BCM57711 and BCM57712 configured for iSCSI and FCoE boot, iSCSI and FCoE boot configuration is lost after firmware upgrade. This is observed in the following cases:

Using a Broadcom adapter based on BCM5709, BCM57711 or BCM57712.

Having either iSCSI boot or FCoE boot configuration in the option ROM.

Upgrading the firmware with HUU.

Workaround   Record the configuration before the firmware upgrade and reapply it after the upgrade. (CSCtr85387)

Caveats from Previous Releases

Release 1.3(2d)

This section lists the open caveats for the 1.3(2d) release:

CIMC

Symptom    When you power on the chassis with some PS power cables disconnected, the system health LED on the front panel stays green, though some power supplies have no input voltage.

Workaround   Connect all cables from APC power to the power supply securely. (CSCtg92856)

Symptom    CIMC Web GUI and CLI correctly reports the number of failed DIMMs, but does not display which of the DIMMs have failed.

Workaround   BIOS Setup (F2) or CIMC System Event Log can display the exact failed DIMMs. (CSCto09153)

Symptom    On C460 servers, the CIMC Web GUI does not display Cisco P81E card details when the main CPU is powered off.

Workaround   Use the CIMC CLI or power on the main CPU. (CSCtn75815)


Note Release 1.3(1) does not support UCS integration. Customers who want to integrate their C-Series server with a UCS instance must use release 1.2(x). If your server is currently running 1.3(1), you need to downgrade it using the 1.2.2 Host Upgrade Utility. For more information, see the Hardware Installation Guide for the type of server you are integrating.


Release 1.3(1c)

This section lists the open caveats for the 1.3(1c) release:

CIMC

Symptom    CIMC storage view of LSI 9260 card occasionally reports 0 Cache Memory size.

Workaround   There is no workaround for CIMC storage management views. You can use host-based MSM tools to corroborate data. (CSCtn08982)

Symptom    When NIC mode is in shared_lom and the boot order is such that EFI is not the first one in the order and there is no other media to boot from, the following message is displayed - "Select proper media else press a key". If you enter a key, the KVM session terminates.

Workaround   Ensure that you have the proper media in place before trying to boot from the device. If not, when prompted with above message, you will have to place the required media and then reboot the host. Else have the system in dedicated mode. (CSCtl82492)

Symptom    PI2CPerformOP ioctl driver failures occur in CIMC log.

Workaround   This failure message is seen when CIMC couldn't communicate to certain devices, due to the devices being missing or if there is a momentary communication failure. If the messages are constant, this may indicate a problem with the server. There is no workaround for this issue. (CSCtn55177)

Symptom    The CIMC firmware upgrade utility can cause an error on the CIMC that will cause System Event Log (SEL) messages to be repeated as if the CIMC had just been restarted.

Workaround   None. Firmware upgrade will complete successfully, but dozens of extra redundant SEL messages can occur. (CSCtl12301)

MISC

Symptom    SMASH memory enumeration can fail on UCS-C460-M1.

Workaround   None for SMASH interfaces. Memory related data can be retrieved through CiIC CLI or WebUI. (CSCtn29771)

vKVM/vMedia

Symptom    KVM fails to launch with a pop-up "Unable to launch Application".

Workaround   Follow these steps:


Step 1 Update the JRE to http://www.java.com/en/download/inc/windows_upgrade_ie.jsp

Step 2 Close all browsers.

Step 3 Clear the cache (Internet Options -> Tools).


Open a new browser window and start a CIMC session. KVM should now be able to launch. (CSCtl70994)

Symptom    Garbled WebUI output when LSI 9280-4i4e card is installed and external JBOD connected.

Workaround   There is no actual data integrity problem, but the displays can be significantly garbled. One workaround is to only use external or only internal on any given controller card. Another is to use host based tools to display information on controllers where both internal and external storage is connected. (CSCtn03816)

Release 1.2(2d)

This section lists the open caveats for the 1.2(2d) release:

CIMC

Symptom    C460 CIMC network mode shared_lom_10g with active-standby redundancy can stop working when the host OS is also using 10GE LOM port and then is rebooted.

Workaround   Do not use the CIMC network mode shared_lom_10g. Use one of the other modes instead. (CSCtj57061)

Symptom    C460 CIMC network mode shared_lom_10g with active-active redundancy will lose connectivity temporarily when the host OS is also using a 10GE LOM port.

Workaround   Do not use CIMC network mode shared_lom_10g. Use one of the other modes instead. (CSCtj58245)

Symptom    LED sensor color is displayed as Red or Amber or Blue (or any supported color) even though LED state if OFF.

Workaround   Ignore LED color when LED state is OFF. (CSCth84883)

Symptom    Network mode cannot be set to cisco_card mode even though the option is available.

Workaround   Install Cisco UCS P81E card to move into cisco_card network mode. (CSCth87044)

Symptom    If you try to move to cisco_card mode from the CIMC Configuration Utility, you see the error "Net mode invalid".

Workaround   Install either just one or two R2X0-PSU2-650-SB power supply units in the server. Restart the CIMC and move to cisco_card mode. (CSCti70359)

LSI

Symptom    The host based LSI tool MegaCli when executed will display a "Permission Denied" message on ESXi4.1 and ESX4.1 operating system.

Workaround   After installing MegaCli on ESXi4.1 or ESX4.1, use the following command to change permission: chmod 755 MegaCli. Once the permission is changed, MegaCli command and options work successfully. (CSCtk11863)

Symptom    LSI Storage controllers on C-460 M1, C200 M2, C250-M2 servers running ESX4.1 and ESXi4.1 cannot be managed using the host application MegaRAID Storage Manager running on remote clients.

Workaround   The LSI controller can be managed using WebBIOS which can be accessed using Cntrl+H keys during BIOS bootup when LSI controller is scanned. (CSCtk06208)

This section lists the open caveats in the 1.2(1a) release:

CIMC

Symptom    When updating CIMC firmware through TFTP, if the image file is corrupted, the update status indicator is the same as if the file does not exist.

Workaround   Be aware that this error message can actually indicate either of the above conditions and should make sure that the file both the exists, and is a valid firmware image for the CIMC being upgraded. (CSCti17492)

BIOS

Symptom    If the current CIMC networking mode is shipping mode, then the BIOS F8 CIMC configuration utility does not allow a new networking mode and IP address to be set at the same time.

Workaround   Set the new networking mode, save, then set the new IP address and save again. (CSCth71350)

Release 1.1.(2)

This section lists the open caveats for the 1.1(2a) release and applies to the M1 version of the C460 server.

MISC

Symptom    If the number of Virtual Drives created in the LSI MegaRAID controller is greater than or equal to 50, the system will not boot from any of these Virtual Drives.

Workaround   None. The system boots from MegaRAID Virtual Drives only if the number of Virtual Drives are lesser than or equal to 49. (CSCtg25373)

This section lists the known behaviors for the 1.1(2a) release and applies to the M1 version of the C460 server.

BIOS

Symptom    Serial port B cannot be enabled for console redirection in the Server Management —> Console Redirection page of the BIOS setup.

Workaround   Serial port B is primarily used for SOL functionality. The BIOS will start redirecting console messages to serial port B if SOL is enabled. You should enable SOL through BMC to get console redirection messages through serial port B. (CSCtf54851)

Symptom    System reboots during EFI Windows 2008 R2 installation.

Workaround   EFI OS installation is not supported by the BIOS. You should disable the EFI- Optimized mode in the BIOS setup and install Windows 2008 R2 in legacy mode. (CSCtf87728)

CIMC

Symptom    The CIMC time/date is set to 1970.

Workaround   Do not reboot the CIMC after the BIOS sets the time/date for the CIMC. (CSCtc21237)

Release 1.1(1)

The following caveats were opened in UCS software release 1.1(1d) and are still unresolved.

This section lists the open caveats for the 1.1(1d) release. Unless otherwise noted, the caveats are for all rack server platforms.

BIOS

Symptom    Installation of any UEFI Aware Operating System may result in a complete system failure.

Workaround   No workaround exists. We do not support UEFI aware Operating Systems. (CSCtd71780)

Release 1.0(2)

The following caveats were opened in UCS software release 1.0(2) and are still unresolved.

This section lists the open caveats for this release. Unless otherwise noted, the caveats are for all rack server platforms.

BIOS

Symptom    Installation of any UEFI Aware Operating System may result in a complete system failure.

Workaround   No workaround exists. We do not support UEFI aware Operating Systems. (CSCtd71780)

Release 1.0(1d)

The following caveats were opened in UCS software release 1.0(1d) and are still unresolved.

Misc

Symptom    The following message appears after installation or upgrade to ESX 4.0 vSphere:
Error:TSC: 1137350434cpu0 :0)NUMA : 827 Signficant imbalance between NUMA nodes detected. Performance may be impacted.:

Workaround   There are two possible workarounds.

Option 1: Ensure that memory configuration is equal across both processors. Ensure that there are equal amounts of DIMMs of the same size and speed inserted in the DIMM sockets.

Option 2: Reboot system and enter BIOS setup by pressing F2. Go to
Advanced-->Memory Configuration-->Memory RAS --> Performance Configuration--> and change NUMA Optimized to Disabled. Press F10 to save and reboot. (CSCtc33846)

BIOS

Symptom    Installation of any UEFI Aware Operating System may result in a complete system failure.

Workaround   No workaround exists. We do not support UEFI Aware Operating Systems. (CSCtd71780)

Release 1.0(1)

The following caveats were opened in UCS software release 1.0(1) and are still unresolved.

KVM

Symptom    Launching the KVM console with Microsoft Internet Explorer browsers fails and causes the message "Internet Explorer was not able to open this Internet site. The requested site is either unavailable or cannot be found". This error occurs with Microsoft Internet Explorer browsers with the advanced "Do not save encrypted pages to disk" option set.

Workaround   From the Internet Explorer toolbar, select Tools -> Internet Options. The Internet Options dialog will pop up. Click the Advanced tab and uncheck the "Do not save encrypted pages to disk" option. (CSCtd19439)

Web UI

Symptom    Printing from Web UI will work from Internet Exploder, but not Firefox.

Workaround   None. (CSCtc22985)

Documentation Updates

Active Directory

In the section titled "Active Directory" in the Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.2(1), and the Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.2(1), the following statement is incorrect:

"When Active Directory is enabled in the CIMC, all user authentication and role authorization is performed by Active Directory, and the CIMC ignores the local database. If the CIMC cannot connect to Active Directory, it reverts to the local database."

The correct behavior is as follows:

"When Active Directory is enabled, user authentication and role authorization are performed by Active Directory for user accounts not found in the local user database."

Related Documentation

For configuration information for this release, please refer to the following:

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.1(1)

Cisco UCS C-Series Servers Integrated Management Controller Configuration Guide, Release 1.1(1)

Cisco UCS C-Series Servers Integrated Management Controller CLI Command Reference, Release 1.1(1)

The following related documentation is available for the Cisco Unified Computing System:

Cisco UCS C-Series Servers Documentation Roadmap

Cisco UCS Site Preparation Guide

Regulatory Compliance and Safety Information for Cisco UCS

Obtaining Documentation and Submitting a Service Request

For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a service request, and gathering additional information, see What's New in Cisco Product Documentation at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html.

Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The RSS feeds are a free service.