Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.3
Viewing Server Properties
Downloads: This chapterpdf (PDF - 483.0KB) The complete bookPDF (PDF - 2.03MB) | Feedback

Viewing Server Properties

Viewing Server Properties

This chapter includes the following sections:

Viewing CPU Properties

Before You Begin

The server must be powered on, or the properties will not display.

Procedure
      Command or Action Purpose
    Step 1 Server# scope chassis  

    Enters chassis command mode.

     
    Step 2 Server /chassis # show cpu [detail]  

    Displays CPU properties.

     

    This example displays CPU properties:

    Server# scope chassis
    Server /chassis # show cpu
    Name         Cores    Version                                            
    ------------ -------- -------------------------------------------------- 
    CPU1         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
    CPU2         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
    
    Server /chassis #  
    

    Viewing Memory Properties

    Before You Begin

    The server must be powered on, or the properties will not display.

    Procedure
        Command or Action Purpose
      Step 1 Server# scope chassis  

      Enters chassis command mode.

       
      Step 2 Server /chassis # show dimm [detail]  

      Displays memory properties.

       
      Step 3 Server /chassis # show dimm-summary  

      Displays DIMM summary information.

       

      This example displays memory properties:

      Server# scope chassis
      Server /chassis # show dimm
      Name                 Capacity        Channel Speed (MHz) Channel Type    
      -------------------- --------------- ------------------- --------------- 
      DIMM_A1              2048 MB         1067                Other           
      DIMM_A2              2048 MB         1067                Other           
      DIMM_B1              2048 MB         1067                Other           
      DIMM_B2              2048 MB         1067                Other           
      DIMM_C1              Not Installed   Unknown             Other           
      DIMM_C2              Not Installed   Unknown             Other           
      DIMM_D1              2048 MB         1067                Other           
      DIMM_D2              2048 MB         1067                Other           
      DIMM_E1              2048 MB         1067                Other           
      DIMM_E2              2048 MB         1067                Other           
      DIMM_F1              Not Installed   Unknown             Other           
      DIMM_F2              Not Installed   Unknown             Other           
      
      Server /chassis # 
      

      This example displays detailed information about memory properties:

      Server# scope chassis
      Server /chassis # show dimm detail
      Name DIMM_A1:
          Capacity: 2048 MB
          Channel Speed (MHz): 1067
          Channel Type: Other
          Memory Type Detail: Synchronous
          Bank Locator: NODE 0 CHANNEL 0 DIMM 0
          Visibility: Yes
          Operability: Operable
          Manufacturer: 0x802C
          Part Number: 18JSF25672PY-1G1D1
          Serial Number: 0xDA415F3F
          Asset Tag: Unknown
          Data Width: 64 bits
      Name DIMM_A2:
          Capacity: 2048 MB
      --More--   
      
      Server /chassis # 
      

      This example displays DIMM summary information:

      Server# scope chassis
      Server /chassis # show dimm-summary
      DIMM Summary:
          Memory Speed: 1067 MHz
          Total Memory: 16384 MB
          Effective Memory: 16384 MB
          Redundant Memory: 0 MB
          Failed Memory: 0 MB
          Ignored Memory: 0 MB
          Number of Ignored Dimms: 0
          Number of Failed Dimms: 0
          Memory RAS possible: Memory configuration can support mirroring
          Memory Configuration: Maximum Performance
      
      Server /chassis # 
      

      Viewing Power Supply Properties

      Before You Begin

      The server must be powered on, or the properties will not display.

      Procedure
          Command or Action Purpose
        Step 1 Server# scope chassis  

        Enters chassis command mode.

         
        Step 2 Server /chassis # show psu [detail]  

        Displays power supply properties.

         

        This example displays power supply properties:

        Server# scope chassis
        Server /chassis # show psu
        Name       In. Power (Watts)    Out. Power (Watts)   Firmware  Status     
        ---------- -------------------- -------------------- -------- ---------- 
        PSU1       74                   650                  R0E      Present    
        PSU2       83                   650                  R0E      Present    
        
        Server /chassis #  
        

        Viewing Storage Properties

        Viewing Storage Adapter Properties

        Before You Begin

        The server must be powered on, or the properties will not display.

        Procedure
            Command or Action Purpose
          Step 1 Server# scope chassis  

          Enters the chassis command mode.

           
          Step 2 Server /chassis # show storageadapter [slot] [detail]  

          Displays installed storage cards.

          Note   

          This command displays all MegaRAID controllers on the server that can be managed through CIMC. If an installed controller or storage device is not displayed, then it cannot be managed through CIMC.

           
          Step 3 Server /chassis # scope storageadapter slot  

          Enters command mode for an installed storage card.

           
          Step 4 Server /chassis/storageadapter # show bbu [detail]  

          Displays battery backup unit information for the storage card.

           
          Step 5 Server /chassis/storageadapter # show capabilites [detail]  

          Displays RAID levels supported by the storage card.

           
          Step 6 Server /chassis/storageadapter # show error-counters [detail]  

          Displays number of errors seen by the storage card.

           
          Step 7 Server /chassis/storageadapter # show firmware-versions [detail]  

          Displays firmware version information for the storage card.

           
          Step 8 Server /chassis/storageadapter # show hw-config [detail]  

          Displays hardware information for the storage card.

           
          Step 9 Server /chassis/storageadapter # show mfg-data [detail]  

          Displays manufacturer data for the storage card.

           
          Step 10 Server /chassis/storageadapter # show pci-info [detail]  

          Displays adapter PCI information for the storage card.

           
          Step 11 Server /chassis/storageadapter # show running-firmware-images [detail]  

          Displays running firmware information for the storage card.

           
          Step 12 Server /chassis/storageadapter # show settings [detail]  

          Displays adapter firmware settings for the storage card.

           
          Step 13 Server /chassis/storageadapter # show startup-firmware-images [detail]  

          Displays firmware images to be activated on startup for the storage card.

           

          This example displays storage properties:

          Server# scope chassis
          Server /chassis # show storageadapter
          PCI Slot Product Name                       Serial Number  Firmware Package Build    
          -------- ---------------------------------- -------------- ------------------------- 
          SAS      LSI MegaRAID SAS 9260-8i           SV93404392     12.12.0-0038                      
          
                    Product ID     Battery Status Cache Memory Size 
               ---- -------------- -------------- -------------- 
                    LSI Logic      fully charged  0 MB           
          
          Server /chassis #             
          

          This example displays battery backup unit information for the storage card named SAS:

          Server# scope chassis
          Server /chassis # scope storageadapter SAS
          Server /chassis/storageadapter # show bbu
          Controller Battery Type Battery Present Voltage    Current    Charge Charging State 
          ---------- ------------ --------------- ---------- ---------- ------ -------------- 
          SAS        iBBU         true            4.051 V    0.000 A    100%   fully charged  
          
          Server /chassis/storageadapter #             
          

          Viewing the Flexible Flash Controller Properties

          Before You Begin
          • Cisco Flexible Flash must be supported by your platform.
          Procedure
              Command or Action Purpose
            Step 1 Server# scope chassis  

            Enters the chassis command mode.

             
            Step 2 Server /chassis # show flexflash detail  

            (Optional) Displays the available Cisco Flexible Flash controllers.

             
            Step 3 Server /chassis # scope flexflash index  

            Enters the Cisco Flexible Flash controller command mode for the specified controller. At this time, the only permissible index value is FlexFlash-0.

             
            Step 4 Server /chassis/flexflash # show operational-profile detail 

            Displays the operational profile properties.

             

            This example displays the properties of the flash controller:

            Server# scope chassis
            Server /chassis # show flexflash
            Controller   Product Name     Firmware Version  Internal State  Vendor   
            ------------ ---------------- ----------------- --------------- -------- 
            FlexFlash-0  Cisco FlexFlash  1.2 build 247     Connected       Cypress  
            
            Server /chassis # scope flexflash FlexFlash-0
            Server /chassis # show operational-profile
            Primary Member Slot  I/O Error Threshold  Host Accessible VDs  
            -------------------- -------------------- -------------------- 
            slot1                100                  SCU Drivers  
            
            Server /chassis/flexflash #
            

            Viewing Physical Drive Properties

            Procedure
                Command or Action Purpose
              Step 1 Server# scope chassis  

              Enters the chassis command mode.

               
              Step 2 Server /chassis # scope storageadapter slot  

              Enters command mode for an installed storage card.

               
              Step 3 Server /chassis/storageadapter # show physical-drive [drive-number] [detail]  

              Displays physical drive information for the storage card.

               
              Step 4 Server /chassis/storageadapter # show physical-drive-count [detail]  

              Displays the number of physical drives on the storage card.

               
              Step 5 Server /chassis/storageadapter # scope physical-drive drive-number  

              Enters command mode for the specified physical drive.

               
              Step 6 Server /chassis/storageadapter/physical-drive # show general [detail]  

              Displays general information about the specified physical drive.

               
              Step 7 Server /chassis/storageadapter/physical-drive # show inquiry-data [detail]  

              Displays inquiry data about the specified physical drive.

               
              Step 8 Server /chassis/storageadapter/physical-drive # show status [detail]  

              Displays status information about the specified physical drive.

               

              This example displays general information about physical drive number 1 on the storage card named SAS:

              Server# scope chassis
              Server /chassis # scope storageadapter SAS
              Server /chassis/storageadapter # scope physical-drive 1
              Server /chassis/storageadapter/physical-drive # show general
              Slot Number 1:
                  Controller: SAS
                  Enclosure Device ID: 27
                  Device ID: 34
                  Sequence Number: 2
                  Media Error Count: 0
                  Other Error Count: 0
                  Predictive Failure Count: 0
                  Link Speed: 6.0 Gb/s
                  Interface Type: SAS
                  Media Type: HDD
                  Block Size: 512
                  Block Count: 585937500
                  Raw Size: 286102 MB
                  Non Coerced Size: 285590 MB
                  Coerced Size: 285568 MB
                  SAS Address 0: 500000e112693fa2
                  SAS Address 1: 
                  Connected Port 0: 
                  Connected Port 1: 
                  Connected Port 2: 
                  Connected Port 3: 
                  Connected Port 4: 
                  Connected Port 5: 
                  Connected Port 6: 
                  Connected Port 7: 
                  Power State: powersave
              
              Server /chassis/storageadapter/physical-drive #             
              

              This example displays inquiry data about physical drive number 1 on the storage card named SAS:

              Server# scope chassis
              Server /chassis # scope storageadapter SAS
              Server /chassis/storageadapter # scope physical-drive 1
              Server /chassis/storageadapter/physical-drive # show inquiry-data
              Slot Number 1:
                  Controller: SAS
                  Product ID: MBD2300RC
                  Drive Firmware: 5701
                  Drive Serial Number: D010P9A0016D
              
              Server /chassis/storageadapter/physical-drive #             
              

              This example displays status information about physical drive number 1 on the storage card named SAS:

              Server# scope chassis
              Server /chassis # scope storageadapter SAS
              Server /chassis/storageadapter # scope physical-drive 1
              Server /chassis/storageadapter/physical-drive # show inquiry-data
              Slot Number 1:
                  Controller: SAS
                  State: online
                  Online: true
                  Fault: false
              
              Server /chassis/storageadapter/physical-drive #             
              

              Viewing Virtual Drive Properties

              Procedure
                  Command or Action Purpose
                Step 1 Server# scope chassis  

                Enters the chassis command mode.

                 
                Step 2 Server /chassis # scope storageadapter slot  

                Enters command mode for an installed storage card.

                 
                Step 3 Server /chassis/storageadapter # show virtual-drive [drive-number] [detail]  

                Displays virtual drive information for the storage card.

                 
                Step 4 Server /chassis/storageadapter # show virtual-drive-count [detail]  

                Displays the number of virtual drives configured on the storage card.

                 
                Step 5 Server /chassis/storageadapter # scope virtual-drive drive-number  

                Enters command mode for the specified virtual drive.

                 
                Step 6 Server /chassis/storageadapter/virtual-drive # show physical-drive [detail]  

                Displays physical drive information about the specified virtual drive.

                 

                This example displays information about virtual drives on the storage card named SAS:

                Server# scope chassis
                Server /chassis # scope storageadapter SAS
                Server /chassis/storageadapter # show virtual-drive
                Virtual Drive  Status          Name                     Size       RAID Level 
                -------------- --------------- ------------------------ ---------- ---------- 
                0              Optimal         SLES1SP1beta5            30720 MB   RAID 0     
                1              Optimal         RHEL5.5                  30720 MB   RAID 0     
                2              Optimal         W2K8R2_DC                30720 MB   RAID 0     
                3              Optimal         VD_3                     30720 MB   RAID 0     
                4              Optimal         ESX4.0u2                 30720 MB   RAID 0     
                5              Optimal         VMs                      285568 MB  RAID 0     
                6              Optimal         RHEL6-35GB               35840 MB   RAID 0     
                7              Optimal         OS_Ins_Test_DR           158720 MB  RAID 0     
                8              Optimal                                  285568 MB  RAID 1        
                
                Server /chassis/storageadapter #             
                

                This example displays physical drive information about virtual drive number 1 on the storage card named SAS:

                Server# scope chassis
                Server /chassis # scope storageadapter SAS
                Server /chassis/storageadapter # scope virtual-drive 1
                Server /chassis/storageadapter/virtual-drive # show physical-drive
                Span  Physical Drive Status     Starting Block Number Of Blocks 
                ----- -------------- ---------- -------------- ---------------- 
                0     12             online     62914560       62914560         
                
                Server /chassis/storageadapter/virtual-drive #             
                

                Viewing PCI Adapter Properties

                Before You Begin

                The server must be powered on, or the properties will not display.

                Procedure
                    Command or Action Purpose
                  Step 1 Server# scope chassis  

                  Enters the chassis command mode.

                   
                  Step 2 Server /chassis # show pci-adapter [detail]  

                  Displays PCI adapter properties.

                   

                  This example displays PCI adapter properties:

                  Server# scope chassis
                  Server /chassis # show pci-adapter
                  Name             Slot  Vendor ID    Device ID    Product Name              
                  ---------------- ----- ------------ ------------ ------------------------- 
                  PCIe Adapter1    1     0x1137       0x0042       Cisco UCS P81E Virtual... 
                  PCIe Adapter2    5     0x1077       0x2432       Qlogic QLE2462 4Gb dua... 
                  
                  Server /chassis #