Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.4
Viewing Server Properties
Downloads: This chapterpdf (PDF - 503.0KB) The complete bookPDF (PDF - 2.93MB) | Feedback

Viewing Server Properties

Viewing Server Properties

This chapter includes the following sections:

Viewing Server Properties

Procedure
      Command or Action Purpose
    Step 1 Server# show chassis [detail]  

    Displays server properties.

     

    This example displays server properties:

    Server# show chassis detail
    Chassis:
        Power: on
        Serial Number: QCI140205ZG
        Product Name: UCS C210 M2
        PID : R210-2121605W
        UUID: FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF
        Locator LED: off
        Description: 
        Power Restore Policy: power-off
        Power Delay Type: fixed
        Power Delay Value(sec): 0
    
    Server#  
    

    Viewing CIMC Properties


    Note


    CIMC gets the current date and time from the server BIOS. To change this information, reboot the server and press F2 when prompted to access the BIOS configuration menu. Then change the date or time using the options on the main BIOS configuration tab.


    Procedure
        Command or Action Purpose
      Step 1 Server# show cimc [detail]  

      Displays CIMC properties.

       

      This example displays CIMC properties:

      Server# show cimc detail
      CIMC:
          Firmware Version: 1.4(2.18)
          Current Time: Wed Jan 11 07:01:50 2012
          Boot-loader Version: 1.4(2.18).16
      
      Server#  
      

      Viewing CPU Properties

      Before You Begin

      The server must be powered on, or the properties will not display.

      Procedure
          Command or Action Purpose
        Step 1 Server# scope chassis  

        Enters chassis command mode.

         
        Step 2 Server /chassis # show cpu [detail]  

        Displays CPU properties.

         

        This example displays CPU properties:

        Server# scope chassis
        Server /chassis # show cpu
        Name         Cores    Version                                            
        ------------ -------- -------------------------------------------------- 
        CPU1         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
        CPU2         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
        
        Server /chassis #  
        

        Viewing Memory Properties

        Before You Begin

        The server must be powered on, or the properties will not display.

        Procedure
            Command or Action Purpose
          Step 1 Server# scope chassis  

          Enters chassis command mode.

           
          Step 2 Server /chassis # show dimm [detail]  

          Displays memory properties.

           
          Step 3 Server /chassis # show dimm-summary  

          Displays DIMM summary information.

           

          This example displays memory properties:

          Server# scope chassis
          Server /chassis # show dimm
          Name                 Capacity        Channel Speed (MHz) Channel Type    
          -------------------- --------------- ------------------- --------------- 
          DIMM_A1              2048 MB         1067                Other           
          DIMM_A2              2048 MB         1067                Other           
          DIMM_B1              2048 MB         1067                Other           
          DIMM_B2              2048 MB         1067                Other           
          DIMM_C1              Not Installed   Unknown             Other           
          DIMM_C2              Not Installed   Unknown             Other           
          DIMM_D1              2048 MB         1067                Other           
          DIMM_D2              2048 MB         1067                Other           
          DIMM_E1              2048 MB         1067                Other           
          DIMM_E2              2048 MB         1067                Other           
          DIMM_F1              Not Installed   Unknown             Other           
          DIMM_F2              Not Installed   Unknown             Other           
          
          Server /chassis # 
          

          This example displays detailed information about memory properties:

          Server# scope chassis
          Server /chassis # show dimm detail
          Name DIMM_A1:
              Capacity: 2048 MB
              Channel Speed (MHz): 1067
              Channel Type: Other
              Memory Type Detail: Synchronous
              Bank Locator: NODE 0 CHANNEL 0 DIMM 0
              Visibility: Yes
              Operability: Operable
              Manufacturer: 0x802C
              Part Number: 18JSF25672PY-1G1D1
              Serial Number: 0xDA415F3F
              Asset Tag: Unknown
              Data Width: 64 bits
          Name DIMM_A2:
              Capacity: 2048 MB
          --More--   
          
          Server /chassis # 
          

          This example displays DIMM summary information:

          Server# scope chassis
          Server /chassis # show dimm-summary
          DIMM Summary:
              Memory Speed: 1067 MHz
              Total Memory: 16384 MB
              Effective Memory: 16384 MB
              Redundant Memory: 0 MB
              Failed Memory: 0 MB
              Ignored Memory: 0 MB
              Number of Ignored Dimms: 0
              Number of Failed Dimms: 0
              Memory RAS possible: Memory configuration can support mirroring
              Memory Configuration: Maximum Performance
          
          Server /chassis # 
          

          Viewing Power Supply Properties

          Before You Begin

          The server must be powered on, or the properties will not display.

          Procedure
              Command or Action Purpose
            Step 1 Server# scope chassis  

            Enters chassis command mode.

             
            Step 2 Server /chassis # show psu [detail]  

            Displays power supply properties.

             

            This example displays power supply properties:

            Server# scope chassis
            Server /chassis # show psu
            Name       In. Power (Watts)    Out. Power (Watts)   Firmware  Status     
            ---------- -------------------- -------------------- -------- ---------- 
            PSU1       74                   650                  R0E      Present    
            PSU2       83                   650                  R0E      Present    
            
            Server /chassis #  
            

            Viewing Storage Properties

            Viewing Storage Adapter Properties

            Before You Begin

            The server must be powered on, or the properties will not display.

            Procedure
                Command or Action Purpose
              Step 1 Server# scope chassis  

              Enters the chassis command mode.

               
              Step 2 Server /chassis # show storageadapter [slot] [detail]  

              Displays installed storage cards.

              Note   

              This command displays all MegaRAID controllers on the server that can be managed through CIMC. If an installed controller or storage device is not displayed, then it cannot be managed through CIMC.

               
              Step 3 Server /chassis # scope storageadapter slot  

              Enters command mode for an installed storage card.

               
              Step 4 Server /chassis/storageadapter # show bbu [detail]  

              Displays battery backup unit information for the storage card.

               
              Step 5 Server /chassis/storageadapter # show capabilites [detail]  

              Displays RAID levels supported by the storage card.

               
              Step 6 Server /chassis/storageadapter # show error-counters [detail]  

              Displays number of errors seen by the storage card.

               
              Step 7 Server /chassis/storageadapter # show firmware-versions [detail]  

              Displays firmware version information for the storage card.

               
              Step 8 Server /chassis/storageadapter # show hw-config [detail]  

              Displays hardware information for the storage card.

               
              Step 9 Server /chassis/storageadapter # show mfg-data [detail]  

              Displays manufacturer data for the storage card.

               
              Step 10 Server /chassis/storageadapter # show pci-info [detail]  

              Displays adapter PCI information for the storage card.

               
              Step 11 Server /chassis/storageadapter # show running-firmware-images [detail]  

              Displays running firmware information for the storage card.

               
              Step 12 Server /chassis/storageadapter # show settings [detail]  

              Displays adapter firmware settings for the storage card.

               
              Step 13 Server /chassis/storageadapter # show startup-firmware-images [detail]  

              Displays firmware images to be activated on startup for the storage card.

               

              This example displays storage properties:

              Server# scope chassis
              Server /chassis # show storageadapter
              PCI Slot Product Name                       Serial Number  Firmware Package Build    
              -------- ---------------------------------- -------------- ------------------------- 
              SAS      LSI MegaRAID SAS 9260-8i           SV93404392     12.12.0-0038                      
              
                        Product ID     Battery Status Cache Memory Size 
                   ---- -------------- -------------- -------------- 
                        LSI Logic      fully charged  0 MB           
              
              Server /chassis #             
              

              This example displays battery backup unit information for the storage card named SAS:

              Server# scope chassis
              Server /chassis # scope storageadapter SAS
              Server /chassis/storageadapter # show bbu
              Controller Battery Type Battery Present Voltage    Current    Charge Charging State 
              ---------- ------------ --------------- ---------- ---------- ------ -------------- 
              SAS        iBBU         true            4.051 V    0.000 A    100%   fully charged  
              
              Server /chassis/storageadapter #             
              

              Viewing the Flexible Flash Controller Properties

              Before You Begin
              • Cisco Flexible Flash must be supported by your platform.
              Procedure
                  Command or Action Purpose
                Step 1 Server# scope chassis  

                Enters the chassis command mode.

                 
                Step 2 Server /chassis # show flexflash detail  

                (Optional) Displays the available Cisco Flexible Flash controllers.

                 
                Step 3 Server /chassis # scope flexflash index  

                Enters the Cisco Flexible Flash controller command mode for the specified controller. At this time, the only permissible index value is FlexFlash-0.

                 
                Step 4 Server /chassis/flexflash # show operational-profile detail 

                Displays the operational profile properties.

                 

                This example displays the properties of the flash controller:

                Server# scope chassis
                Server /chassis # show flexflash
                Controller   Product Name     Has Error  Firmware Version  Vendor   Internal State
                ------------ ---------------- ---------- ----------------- -------- ---------------
                FlexFlash-0  Cisco FlexFlash  No         1.2 build 247     Cypress  Connected    
                
                Server /chassis # scope flexflash FlexFlash-0
                Server /chassis # show operational-profile
                Primary Member Slot  I/O Error Threshold  Host Accessible VDs  
                -------------------- -------------------- -------------------- 
                slot1                100                  SCU Drivers  
                
                Server /chassis/flexflash #
                

                Viewing Physical Drive Properties

                Procedure
                    Command or Action Purpose
                  Step 1 Server# scope chassis  

                  Enters the chassis command mode.

                   
                  Step 2 Server /chassis # scope storageadapter slot  

                  Enters command mode for an installed storage card.

                   
                  Step 3 Server /chassis/storageadapter # show physical-drive [drive-number] [detail]  

                  Displays physical drive information for the storage card.

                   
                  Step 4 Server /chassis/storageadapter # show physical-drive-count [detail]  

                  Displays the number of physical drives on the storage card.

                   
                  Step 5 Server /chassis/storageadapter # scope physical-drive drive-number  

                  Enters command mode for the specified physical drive.

                   
                  Step 6 Server /chassis/storageadapter/physical-drive # show general [detail]  

                  Displays general information about the specified physical drive.

                   
                  Step 7 Server /chassis/storageadapter/physical-drive # show inquiry-data [detail]  

                  Displays inquiry data about the specified physical drive.

                   
                  Step 8 Server /chassis/storageadapter/physical-drive # show status [detail]  

                  Displays status information about the specified physical drive.

                   

                  This example displays general information about physical drive number 1 on the storage card named SAS:

                  Server# scope chassis
                  Server /chassis # scope storageadapter SAS
                  Server /chassis/storageadapter # scope physical-drive 1
                  Server /chassis/storageadapter/physical-drive # show general
                  Slot Number 1:
                      Controller: SAS
                      Enclosure Device ID: 27
                      Device ID: 34
                      Sequence Number: 2
                      Media Error Count: 0
                      Other Error Count: 0
                      Predictive Failure Count: 0
                      Link Speed: 6.0 Gb/s
                      Interface Type: SAS
                      Media Type: HDD
                      Block Size: 512
                      Block Count: 585937500
                      Raw Size: 286102 MB
                      Non Coerced Size: 285590 MB
                      Coerced Size: 285568 MB
                      SAS Address 0: 500000e112693fa2
                      SAS Address 1: 
                      Connected Port 0: 
                      Connected Port 1: 
                      Connected Port 2: 
                      Connected Port 3: 
                      Connected Port 4: 
                      Connected Port 5: 
                      Connected Port 6: 
                      Connected Port 7: 
                      Power State: powersave
                  
                  Server /chassis/storageadapter/physical-drive #             
                  

                  This example displays inquiry data about physical drive number 1 on the storage card named SAS:

                  Server# scope chassis
                  Server /chassis # scope storageadapter SAS
                  Server /chassis/storageadapter # scope physical-drive 1
                  Server /chassis/storageadapter/physical-drive # show inquiry-data
                  Slot Number 1:
                      Controller: SAS
                      Product ID: MBD2300RC
                      Drive Firmware: 5701
                      Drive Serial Number: D010P9A0016D
                  
                  Server /chassis/storageadapter/physical-drive #             
                  

                  This example displays status information about physical drive number 1 on the storage card named SAS:

                  Server# scope chassis
                  Server /chassis # scope storageadapter SAS
                  Server /chassis/storageadapter # scope physical-drive 1
                  Server /chassis/storageadapter/physical-drive # show inquiry-data
                  Slot Number 1:
                      Controller: SAS
                      State: online
                      Online: true
                      Fault: false
                  
                  Server /chassis/storageadapter/physical-drive #             
                  

                  Viewing Virtual Drive Properties

                  Procedure
                      Command or Action Purpose
                    Step 1 Server# scope chassis  

                    Enters the chassis command mode.

                     
                    Step 2 Server /chassis # scope storageadapter slot  

                    Enters command mode for an installed storage card.

                     
                    Step 3 Server /chassis/storageadapter # show virtual-drive [drive-number] [detail]  

                    Displays virtual drive information for the storage card.

                     
                    Step 4 Server /chassis/storageadapter # show virtual-drive-count [detail]  

                    Displays the number of virtual drives configured on the storage card.

                     
                    Step 5 Server /chassis/storageadapter # scope virtual-drive drive-number  

                    Enters command mode for the specified virtual drive.

                     
                    Step 6 Server /chassis/storageadapter/virtual-drive # show physical-drive [detail]  

                    Displays physical drive information about the specified virtual drive.

                     

                    This example displays information about virtual drives on the storage card named SAS:

                    Server# scope chassis
                    Server /chassis # scope storageadapter SAS
                    Server /chassis/storageadapter # show virtual-drive
                    Virtual Drive  Status          Name                     Size       RAID Level 
                    -------------- --------------- ------------------------ ---------- ---------- 
                    0              Optimal         SLES1SP1beta5            30720 MB   RAID 0     
                    1              Optimal         RHEL5.5                  30720 MB   RAID 0     
                    2              Optimal         W2K8R2_DC                30720 MB   RAID 0     
                    3              Optimal         VD_3                     30720 MB   RAID 0     
                    4              Optimal         ESX4.0u2                 30720 MB   RAID 0     
                    5              Optimal         VMs                      285568 MB  RAID 0     
                    6              Optimal         RHEL6-35GB               35840 MB   RAID 0     
                    7              Optimal         OS_Ins_Test_DR           158720 MB  RAID 0     
                    8              Optimal                                  285568 MB  RAID 1        
                    
                    Server /chassis/storageadapter #             
                    

                    This example displays physical drive information about virtual drive number 1 on the storage card named SAS:

                    Server# scope chassis
                    Server /chassis # scope storageadapter SAS
                    Server /chassis/storageadapter # scope virtual-drive 1
                    Server /chassis/storageadapter/virtual-drive # show physical-drive
                    Span  Physical Drive Status     Starting Block Number Of Blocks 
                    ----- -------------- ---------- -------------- ---------------- 
                    0     12             online     62914560       62914560         
                    
                    Server /chassis/storageadapter/virtual-drive #             
                    

                    Viewing PCI Adapter Properties

                    Before You Begin

                    The server must be powered on, or the properties will not display.

                    Procedure
                        Command or Action Purpose
                      Step 1 Server# scope chassis  

                      Enters the chassis command mode.

                       
                      Step 2 Server /chassis # show pci-adapter [detail]  

                      Displays PCI adapter properties.

                       

                      This example displays PCI adapter properties:

                      Server# scope chassis
                      Server /chassis # show pci-adapter
                      Name             Slot  Vendor ID    Device ID    Product Name              
                      ---------------- ----- ------------ ------------ ------------------------- 
                      PCIe Adapter1    1     0x1137       0x0042       Cisco UCS P81E Virtual... 
                      PCIe Adapter2    5     0x1077       0x2432       Qlogic QLE2462 4Gb dua... 
                      
                      Server /chassis # 
                      

                      Viewing Network Related Properties

                      Viewing LOM Properties

                      You can view the MAC addresses of the LAN On Motherboard (LOM) Ethernet ports.

                      Procedure
                          Command or Action Purpose
                        Step 1 Server# scope cimc  

                        Enters the CIMC command mode.

                         
                        Step 2 Server /cimc # scope network  

                        Enters the network command mode.

                         
                        Step 3 Server /cimc/network # show lom-mac-list [detail]  

                        Displays the MAC addresses of the LOM ports.

                         

                        This example shows how to display the MAC addresses of the LOM ports:

                        Server# scope cimc
                        Server /cimc # scope network
                        Server /cimc/network # show lom-mac-list
                        Interface       MAC Address
                        --------------- --------------------
                        eth0            010000002000
                        eth1            010000002000
                        
                        Server /cimc/network #