Switch Specifications
Environmental Ranges |
|||||
---|---|---|---|---|---|
Operating temperature
|
-40°C to +74°C
|
||||
Storage temperature |
–40 to 185°F (–40 to 85°C) |
||||
Relative humidity |
5 to 95% (noncondensing) |
||||
Operating altitude |
Up to 13,800 ft (3049 m) |
||||
Storage altitude |
Up to 15,000 ft (4570 m) |
||||
Thermal spacing |
1.75 in. (4.4 cm) |
||||
Operational shock |
50G at 11ms, half sine and 200G ar 2.11ms, half sine. |
||||
Non-Operational Shock |
65-80G at 9ms, Trapezoidal |
||||
Physical Specifications |
|||||
Weight |
Without power supply: IE-4010-4S24P; 12.1 lbs (5.46 kg, IE-4010-16S12P: 12.7 lbs (5.78 kg)
|
||||
Dimensions (H x W x D) |
1.75 x 17.5 x 15.0 in. (4.45 x 44.5 x 38.1 cm) |
Nominal input voltage |
PWR-RGD-AC-DC-H: 100 to 240 VAC, 50 to 60 Hz 100 to 250 VDC PWR-RGD-LOW-DC-H: 24 to 60 VDC |
Absolute maximum (short term) input voltage |
PWR-RGD-AC-DC-H: 85 to 265 VAC, 47 to 63 Hz 88 to 300 VDC PWR-RGD-LOW-DC-H: 18 to 75 VDC |
Maximum PoE power available to Powered Devices (PD), with one power supply module installed |
80W |
Maximum PoE power available to Powered Devices (PD), with two power supply modules installed |
200W |
Max Power at 60C |
|||||
---|---|---|---|---|---|
FRU Configuration |
FRU Mode |
IE-4010-4S24P |
IE-4010-16S12P |
||
Watts |
BTU/hr |
Watts |
BTU/hr |
||
With 2 power supplies (150W or 250W), PoE not enabled. |
Redundant |
65 |
222 |
70 |
239 |
With 1 power supply (150W or 250W), PoE not enabled. |
-NA- |
61 |
208 |
65 |
222 |
With 2 150W power supplies, PoE enabled |
Load Shared |
112 |
382 |
117 |
399 |
With 2 250W power supplies, PoE enabled |
Load Shared |
157 |
535 |
156 |
532 |
With 2 power supplies(150W and 250W), PoE enabled |
Load Shared |
133 |
454 |
138 |
471 |