Show Commands
This chapter describes the Cisco NX-OS show commands used to manage a Cisco Nexus 2000 Series Fabric Extender from a Cisco Nexus 5000 Series switch.
show diagnostic result fex
To display the results from the diagnostic tests for a Fabric Extender chassis, use the show diagnostic result fex command.
show diagnostic result fex chassis_ID
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display the results from the diagnostic tests for a Fabric Extender:
switch#
show diagnostic result fex 100
FEX-100: 48x1GE/Supervisor SerialNo : JAF1237ABSE
Overall Diagnostic Result for FEX-100 : OK
Test results: (. = Pass, F = Fail, U = Untested)
0) SPROM: --------------->.
1) MV88E6095: --------------->.
2) Fan: --------------->.
3) Power Supply: --------------->.
4) Temperature Sensor: --------------->.
Eth 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Port ------------------------------------------------------------------------
Eth 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Port ------------------------------------------------------------------------
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show environment fex
To display the environmental sensor status, use the show environment fex command.
show environment fex { all | chassis_ID } [ temperature | power | fan ]
Syntax Description
all |
Displays information for all Fabric Extender chassis. |
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
temperature |
(Optional) Displays temperature sensor information. |
power |
(Optional) Displays power capacity and power distribution information. |
fan |
(Optional) Displays fan information. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display the environmental sensor status for a Fabric Extender:
switch#
show environment fex 100
-----------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-----------------------------------------------------------------
------------------------------------------------------
------------------------------------------------------
Chassis N2K-C2148-FAN -- ok
---------------------------------------------------------------------------
-----------------------------------------------------
PS Model Power Power Status
-----------------------------------------------------
1 N5K-PAC-200W 0.00 0.00 ok
Mod Model Power Power Power Power Status
Requested Requested Allocated Allocated
(Watts) (Amp) (Watts) (Amp)
--- ------------------- ------- ---------- --------- ---------- ----------
1 N5K-C5110T-BF-1GE 24.00 2.00 24.00 2.00 powered-up
Power Supply redundancy mode: redundant
Total Power Capacity 0.00 W
Power reserved for Supervisor(s) 24.00 W
Power currently used by Modules 0.00 W
Total Power Available -24.00 W
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show fex
To display information about a specific Fabric Extender or all attached chassis, use the show fex command.
show fex [ chassis_ID [ detail ]]
Syntax Description
chassis_ID |
(Optional) Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
detail |
(Optional) Displays a detailed listing. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display information about all attached Fabric Extender chassis:
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Online N5K-C5110T-BF-1GE JAF1237ABSE
101 FEX0101 Online N2K-C2248TP-1GE JAF11223333
102 FEX0102 Online N5K-C5110T-BF-1GE JAF1241BLHQ
105 FEX0105 Online N2K-C2232P-10GE JAF1331AKBM
This example shows how to display information about a specific Fabric Extender chassis:
FEX: 101 Description: FEX0101 state: Online
FEX version: 4.2(1)N1(1) [Switch version: 4.2(1)N1(1)]
Extender Model: N2K-C2248TP-1GE, Extender Serial: JAF11223333
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth3/5
Po5 - Interface Up. State: Active
Eth3/5 - Interface Up. State: Active
Eth3/6 - Interface Up. State: Active
This example shows how to display the detailed information about all attached Fabric Extender chassis:
FEX: 100 Description: FEX0100 state: Online
FEX version: 4.2(1)N1(1) [Switch version: 4.2(1)N1(1)]
FEX Interim version: 4.2(1)N1(0.309)
Switch Interim version: 4.2(1)N1(0.309)
Extender Model: N5K-C5110T-BF-1GE, Extender Serial: JAF1237ABSE
Card Id: 70, Mac Addr: 00:0d:ec:b1:13:02, Num Macs: 64
Module Sw Gen: 12594 [Switch Sw Gen: 21]
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth3/3
Po12 - Interface Up. State: Active
Eth3/3 - Interface Up. State: Active
Eth3/4 - Interface Up. State: Active
Fex Port State Fabric Port Primary Fabric
Related Commands
|
|
fex |
Creates a Fabric Extender and enters fabric extender configuration mode. |
show fex detail
To display detailed information about a specific Fabric Extender or all attached chassis, use the show fex detail command.
show fex detail
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display detailed information about all attached Fabric Extender chassis:
FEX: 100 Description: FEX0100 state: Online
FEX version: 4.2(1)N1(1) [Switch version: 4.2(1)N1(1)]
FEX Interim version: 4.2(1)N1(0.326)
Switch Interim version: 4.2(1)N1(0.326)
Extender Model: N5K-C5110T-BF-1GE, Extender Serial: JAF1237ABSE
Card Id: 70, Mac Addr: 00:0d:ec:b1:13:02, Num Macs: 64
Module Sw Gen: 12594 [Switch Sw Gen: 21]
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth3/4
Po12 - Interface Up. State: Active
Eth3/3 - Interface Up. State: Active
Eth3/4 - Interface Up. State: Active
Fex Port State Fabric Port Primary Fabric
Eth100/1/33 Down Po12 Po12
Eth100/1/34 Down Po12 Po12
Eth100/1/35 Down Po12 Po12
Eth100/1/36 Down Po12 Po12
Eth100/1/37 Down Po12 Po12
Eth100/1/38 Down Po12 Po12
Eth100/1/39 Down Po12 Po12
04/16/2010 05:05:23.441707: Module register received
04/16/2010 05:05:23.442886: Registration response sent
04/16/2010 05:05:23.551846: Module Online Sequence
04/16/2010 05:05:56.520856: Module Online
04/16/2010 05:29:38.526605: Deleting route to FEX
04/16/2010 05:29:38.536055: Module disconnected
04/16/2010 05:29:38.537686: Offlining Module
04/16/2010 05:29:38.538260: Module Offline Sequence
04/16/2010 05:29:53.646254: Module Offline
04/16/2010 05:29:54.178401: Deleting route to FEX
04/16/2010 05:29:54.184092: Module disconnected
04/16/2010 05:29:54.186230: Offlining Module
04/16/2010 05:31:13.784346: Module register received
04/16/2010 05:31:13.785410: Registration response sent
04/16/2010 05:31:15.676906: Module Online Sequence
04/16/2010 05:31:50.492714: Module Online
04/16/2010 05:32:18.388033: Deleting route to FEX
04/16/2010 05:32:18.393579: Module disconnected
04/16/2010 05:32:18.394845: Offlining Module
04/16/2010 05:32:18.395412: Module Offline Sequence
04/16/2010 05:32:30.336790: Module Offline
04/16/2010 05:32:30.683558: Deleting route to FEX
04/16/2010 05:32:30.690042: Module disconnected
04/16/2010 05:32:30.692101: Offlining Module
04/16/2010 05:33:42.781911: Module register received
04/16/2010 05:33:42.783432: Registration response sent
04/16/2010 05:33:52.542824: Module Online Sequence
04/16/2010 05:34:33.483417: Module Online
Related Commands
|
|
fex |
Creates a Fabric Extender and enters fabric extender configuration mode. |
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show fex transceiver
To display information about the transceiver connecting a Fabric Extender to the Cisco Nexus 5000 Series switch, use the show fex transceiver command.
show fex chassis_ID transceiver [ calibration | detail ]
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
calibration |
(Optional) Displays detailed calibration information about the transceiver. |
detail |
(Optional) Displays detailed diagnostic information about the transceiver. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display information about the transceiver that connects a Fabric Extender to the Cisco Nexus 5000 Series switch:
switch#
show fex 101 transceiver
part number is SFBR-7700SDZ
serial number is AGD113921ZR
nominal bitrate is 10300 MBits/sec
Link length supported for 50/125mm fiber is 82 m(s)
Link length supported for 62.5/125mm fiber is 26 m(s)
cisco extended id number is 4
part number is SFBR-7700SDZ
serial number is AGD113422LS
nominal bitrate is 10300 MBits/sec
Link length supported for 50/125mm fiber is 82 m(s)
Link length supported for 62.5/125mm fiber is 26 m(s)
cisco extended id number is 4
part number is SFBR-7700SDZ
serial number is AGD11392258
nominal bitrate is 10300 MBits/sec
Link length supported for 50/125mm fiber is 82 m(s)
Link length supported for 62.5/125mm fiber is 26 m(s)
Related Commands
|
|
fex |
Creates a Fabric Extender and enters fabric extender configuration mode. |
show fex version
To display the version information about a Fabric Extender, use the show fex version command.
show fex chassis_ID version
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display the version information about a Fabric Extender:
switch#
show fex 101 version
System boot mode: primary
System image version: 4.2(1)N1(1) [build 4.2(1)N1(0.309)]
Module: Fabric Extender 48x1GE + 4x10G Module
Serial number: JAF11223333
Kernel uptime is 0 day(s), 3 hour(s), 53 minutes(s), 43 second(s)
Last reset at Wed Mar 31 06:28:41 2010
Service: Reload new image
Related Commands
|
|
fex |
Creates a Fabric Extender and enters fabric extender configuration mode. |
show interface fex-fabric
To display all Fabric Extender fabric interfaces, use the show interface fex-fabric command.
show interface fex-fabric
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display all Fabric Extender fabric interfaces:
switch#
show interface fex-fabric
Fex Port Port State Uplink Model Serial
---------------------------------------------------------------
105 Eth1/5 Active 5 N2K-C2232P-10GE JAF1331AKBM
105 Eth1/6 Active 6 N2K-C2232P-10GE JAF1331AKBM
105 Eth1/7 Active 8 N2K-C2232P-10GE JAF1331AKBM
105 Eth1/8 Active 7 N2K-C2232P-10GE JAF1331AKBM
102 Eth1/17 Active 1 N5K-C5110T-BF-1GE JAF1241BLHQ
102 Eth1/19 Active 3 N5K-C5110T-BF-1GE JAF1241BLHQ
102 Eth1/20 Active 4 N5K-C5110T-BF-1GE JAF1241BLHQ
100 Eth3/3 Active 1 N5K-C5110T-BF-1GE JAF1237ABSE
100 Eth3/4 Active 2 N5K-C5110T-BF-1GE JAF1237ABSE
101 Eth3/5 Active 1 N2K-C2248TP-1GE JAF11223333
101 Eth3/6 Active 2 N2K-C2248TP-1GE JAF11223333
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show interface fex-intf
To display the host interfaces pinned to a fabric interface, use the show interface fex-intf command.
show interface interface fex-intf
Syntax Description
interface |
Ethernet or EtherChannel interface. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display the host interfaces pinned to an Ethernet fabric interface on the parent switch:
switch#
show interface ethernet 1/1 fex-intf
This example shows how to display the host interfaces pinned to an EtherChannel fabric interface on the parent switch:
switch#
show interface port-channel 1 fex-intf
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show interface transceiver fex-fabric
To display information about all transceivers connected to fabric interfaces, use the show interface transceiver fex-fabric command.
show interface transceiver fex-fabric [ calibration | detail ]
Syntax Description
calibration |
(Optional) Displays detailed calibration information about the transceiver. |
detail |
(Optional) Displays detailed diagnostic information about the transceiver. |
Command Modes
EXEC mode
Command History
|
|
4.0(1a)N2(1) |
This command was introduced. |
Examples
This example shows how to display information about all transceivers that connect to fabric interfaces:
switch#
show interface transceiver fex-fabric
part number is 74752-9025
serial number is MOC12302468
nominal bitrate is 12000 MBits/sec
Link length supported for 50/125mm fiber is 0 m(s)
Link length supported for 62.5/125mm fiber is 0 m(s)
cisco extended id number is 4
part number is 74752-9025
serial number is MOC12260214
nominal bitrate is 12000 MBits/sec
Link length supported for 50/125mm fiber is 0 m(s)
Link length supported for 62.5/125mm fiber is 0 m(s)
cisco extended id number is 4
part number is 74752-9025
serial number is MOC12301888
nominal bitrate is 12000 MBits/sec
Link length supported for 50/125mm fiber is 0 m(s)
Link length supported for 62.5/125mm fiber is 0 m(s)
cisco extended id number is 4
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show inventory fex
To display the physical inventory of a Fabric Extender, such as the name, description, and volume ID, use the show inventory fex command.
show inventory fex chassis_ID
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display the physical inventory of a specific Fabric Extender chassis:
switch# show inventory fex 100
NAME: "FEX 100 CHASSIS", DESCR: "N5K-C5110T-BF-1GE CHASSIS"
PID: N5K-C5110T-BF-1GE, VID: V01, SN: JAF1237ABSE
NAME: "FEX 100 Module 1", DESCR: "Fabric Extender Module: 48x1GE, 4X10GE Supervi
PID: N5K-C5110T-BF-1GE, VID: V00, SN: JAF1237ABSE
NAME: "FEX 100 Fan 1", DESCR: "Fabric Extender Fan module"
PID: N2K-C2148-FAN, VID: N/A, SN: N/A
NAME: "FEX 100 Power Supply 1", DESCR: "Fabric Extender AC power supply"
PID: N5K-PAC-200W, VID: 00V0, SN: PAC12473L17
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show locator-led
To display the status of the locator LED in a Fabric Extender, use the show locator-led command.
show locator-led status
Syntax Description
status |
Displays the status of the locator LED in a Fabric Extender module. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Usage Guidelines
Use the locator-led command to toggle the locator LED of a Fabric Extender.
Examples
This example shows how to display the modules that have the locator LED set to off or on:
switch# show locator-led status
Component Locator LED Status
-----------------------------------
Related Commands
|
|
locator-led |
Turns on the locator LED of a Fabric Extender chassis. |
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show module fex
To display the module information for a Fabric Extender, use the show module fex command.
show module fex [ all | chassis_ID ]
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
all |
Displays information about all Fabric Extender modules. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display the module information of Fabric Extenders:
switch# show module fex all
FEX Mod Ports Card Type Model Status.
--- --- ----- ---------------------------------- ------------------ -----------
100 1 48 Fabric Extender 48x1GE Module N5K-C5110T-BF-1GE present
101 1 48 Fabric Extender 48x1GE + 4x10G Mod N2K-C2248TP-1GE present
102 1 48 Fabric Extender 48x1GE Module N5K-C5110T-BF-1GE present
105 1 32 Fabric Extender 32x10GE + 8x10G Mo N2K-C2232P-10GE present
FEX Mod Sw Hw World-Wide-Name(s) (WWN)
--- --- -------------- ------ -----------------------------------------------
101 1 4.2(1)N1(1) 0.103 --
FEX Mod MAC-Address(es) Serial-Num
--- --- -------------------------------------- ----------
100 1 000d.ecb1.1300 to 000d.ecb1.132f JAF1237ABSE
101 1 0022.bdd1.3cc0 to 0022.bdd1.3cef JAF11223333
102 1 000d.ecb1.25c0 to 000d.ecb1.25ef JAF1241BLHQ
105 1 000d.ecca.6f40 to 000d.ecca.6f5f JAF1331AKBM
This commands shows how to display the module information for a specific Fabric Extender:
switch# show module fex 100
FEX Mod Ports Card Type Model Status.
--- --- ----- ---------------------------------- ------------------ -----------
100 1 48 Fabric Extender 48x1GE Module N5K-C5110T-BF-1GE present
FEX Mod Sw Hw World-Wide-Name(s) (WWN)
--- --- -------------- ------ -----------------------------------------------
FEX Mod MAC-Address(es) Serial-Num
--- --- -------------------------------------- ----------
100 1 000d.ecb1.1300 to 000d.ecb1.132f JAF1237ABSE
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show provision
To display information about provision, use the show provision command.
show provision failed-config slot-number
Syntax Description
failed-config |
Displays the configuration that failed to be applied to the slot. |
slot-number |
Slot number in the chassis. The range is from 2 to 199. |
Command Modes
EXEC mode
Configuration synchronization mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the preprovisioning configuration that failed to be applied to slot 2:
switch# show provision failed-config 2
Config has not been applied yet for this slot.
Related Commands
|
|
provision |
Preprovisions a module in a slot. |
show running-config exclude-provision |
Displays the running configuration excluding the preprovisioned features. |
slot |
Enables a slot for preprovisioning a module. |
show queuing interface
To display the queuing information of interfaces, use the show queuing interface command.
show queuing interface [ ethernet slot-chassis-no / port-slot-no / port-no ]
Syntax Description
ethernet |
(Optional) Specifies that queuing information be displayed for an Ethernet interface or a Fabric Extender. |
slot-chassis-no |
Slot number of the Ethernet interface or chassis ID of the Fabric Extender. The range is from 1 to 255. |
port-slot-no |
Port number of the Ethernet interface or the remote slot ID of the Fabric Extender. The range is from 1 to 128. |
port-no |
Port number of the Fabric Extender. The range is from 1 to 48. |
Command Default
Displays the queuing information for all interfaces.
Command Modes
EXEC mode
Command History
|
|
4.1(3)N1(1) |
This command was introduced. |
Examples
This example shows how to display the queuing information, including the buffer threshold and queue limit values, of a specified interface on a switch that runs Cisco NX-OS 4.2(1)N2(1):
switch# show queuing interface eth101/1/1
Ethernet101/1/1 queuing information:
Qos-group: 0 3 4 (shared)
---------+---------+-----------
---------+---------+-----------
queue qos-group cos priority bandwidth mtu
--------+------------+--------------+---------+---------+----
3 0 3 4 0 2 3 4 6 WRR 99 9280
Buffer threshold: 163840 bytes
Queue limit: 327680 bytes
Priority-flow-control enabled: no
cos qos-group rx pause tx pause masked rx pause
-------+-----------+---------+---------+---------------
This example shows how to display the queuing information, including the buffer threshold and queue limit values, of a specified interface on a switch that runs Cisco NX-OS 5.0(2)N2(1):
switch# show queuing interface ethernet 1/4
Interface Ethernet1/4 TX Queuing
qos-group sched-type oper-bandwidth
Interface Ethernet1/4 RX Queuing
q-size: 102400, MTU: 1538
drop-type: drop, xon: 0, xoff: 640
Pkts received over the port : 1
Ucast pkts sent to the cross-bar : 0
Mcast pkts sent to the cross-bar : 1
Ucast pkts received from the cross-bar : 1577841
Pkts sent to the port : 1577841
Pkts discarded on ingress : 0
Per-priority-pause status : Rx (Inactive), Tx (Inactive)
drop-type: no-drop, xon: 128, xoff: 240
Pkts received over the port : 0
Ucast pkts sent to the cross-bar : 0
Mcast pkts sent to the cross-bar : 0
Ucast pkts received from the cross-bar : 0
Pkts sent to the port : 0
Pkts discarded on ingress : 0
Per-priority-pause status : Rx (Inactive), Tx (Inactive)
q-size: 122880, MTU: 1538
drop-type: drop, xon: 0, xoff: 768
Pkts received over the port : 0
Ucast pkts sent to the cross-bar : 0
Mcast pkts sent to the cross-bar : 0
Ucast pkts received from the cross-bar : 0
Pkts sent to the port : 1
Pkts discarded on ingress : 0
Per-priority-pause status : Rx (Inactive), Tx (Inactive)
Table 1 describes the significant fields shown in the display.
Table 1 show queuing interface Field Descriptions
|
|
Ethernet... |
Ethernet interface information. |
qoS-group |
Information about QoS groups configured on the switch. |
sched-type |
Type of schedule. |
WRR |
Weighted round robin(WRR). Queue eight for scheduling. |
Priority |
Priority of the queue. |
q-size |
Queue size. |
drop-type |
Queue drop type can be either drop or no-drop. |
MTU |
Maximum transmit unit (MTU) for the queue. |
Xon |
Transmission on at this threshold. |
Xoff |
Transmission off at this threshold. |
Buffer threshold |
Buffer threshold value for the interface. |
Queue limit |
Queue limit value for the interface. |
Related Commands
|
|
hardware buffer-threshold |
Configures the hardware buffer threshold. |
hardware queue-limit |
Configures the hardware queue limit. |
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show running-config exclude-provision
To display the running configuration without the configuration for offline preprovisioned interfaces, use the show running-config exclude-provision command.
show running-config exclude-provision
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the running configuration without the offline preprovisioned interfaces:
switch# show running-config exclude-provision
!Command: show running-config exclude-provision
!Time: Mon Sep 6 08:10:16 2010
username admin password 5 $1$wmFN7Wly$/pjqx1DfAkCCAg/KyxbUz/ role network-admin
username install password 5 ! role network-admin
username praveena password 5 ! role network-operator
no password strength-check
tacacs-server host 192.168.131.54 key 7 "wawy1234"
tacacs-server host 192.168.131.37
tacacs-server host 192.168.131.37 test username user1
aaa group server tacacs+ t1
aaa group server tacacs+ tacacs
radius-server host 192.168.128.5 key 7 "KkwyCet" authentication accounting
aaa group server radius r1
logging event link-status default
logging event trunk-status default
no service recover-errdisable
errdisable recovery interval 600
no errdisable detect cause link-flap
errdisable recovery cause link-flap
errdisable recovery cause udld
Related Commands
|
|
copy running-config startup-config |
Copies the running configuration to the startup configuration. |
provision |
Preprovisions a module in a slot. |
show provision |
Displays the preprovisioned module information. |
show startup-config exclude-provision |
Displays the startup configuration without the preprovisioning information for offline interfaces. |
slot |
Configures a chassis slot for a predefined module. |
show running-config fex
To display the running configuration for Fabric Extenders (FEXs), use the show running-config fex command.
show running-config fex [ all ]
Syntax Description
all |
(Optional) Displays FEX information including default settings. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N2(1) |
This command was introduced. |
Examples
This example shows how to display information on the running FEX configuration, including the buffer threshold value and queue limit:
switch# show running-config fex
!Command: show running-config fex
!Time: Mon Jul 19 07:56:21 2010
description "RedwoodFex100"
description "PortolaFex150"
description "PortolaFex151"
hardware N2232P queue-limit 50000
description "WoodsideFex198"
hardware N2232P queue-limit 20000
no hardware N2248T queue-limit
hardware N2148T buffer-threshold 163840
description "WoodsideFex199"
interface port-channel100
interface port-channel150
Related Commands
|
|
hardware buffer-threshold |
Configures the hardware buffer threshold. |
hardware queue-limit |
Configures the hardware queue limit. |
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show sprom fex
To display information about the SPROM, use the show sprom fex command.
show sprom fex { all | chassis_ID { all | backplane | powersupply module_no }}
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
all |
Displays all SPROM content for a specific Fabric Extender. |
backplane |
Displays the backplane SPROM content for a specific Fabric Extender. |
powersupply |
Displays the power supply SPROM content for a specific Fabric Extender. |
module_no |
Power supply module number for a specific Fabric Extender. The range is from 1 to 2. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display all SPROM content for a specific Fabric Extender:
switch# show sprom fex 100 all
DISPLAY FEX 100 SUP sprom contents
OEM String : Cisco Systems, Inc.
Product Number : N5K-C5110T-BF-1GE
Serial Number : JAF1237ABSE
Part Number : 73-12009-02
snmpOID : 9.12.3.1.9.72.5.0
Supervisor Module specific block:
MAC Addresses : 00-00-00-00-00-00
Max Connector Power: 1000
DISPLAY FEX 100 backplane sprom contents:
OEM String : Cisco Systems, Inc.
Product Number : N5K-C5110T-BF-1GE
Serial Number : JAF1237ABSE
Part Number : 73-12009-02
snmpOID : 9.12.3.1.3.719.0.0
MAC Addresses : 00-0d-ec-b1-13-00
WWN software-module specific block:
License software-module specific block:
DISPLAY FEX 100 power-supply 1 sprom contents:
OEM String : Cisco Systems, Inc.
Product Number : N5K-PAC-200W
Serial Number : PAC12473L17
Part Number : 341-0335-01
snmpOID : 0.0.0.0.0.0.0.0
This command shows how to display the power supply SPROM contents for a specific Fabric Extender:
switch# show sprom fex 100 powersupply 1
DISPLAY FEX 100 power-supply 1 sprom contents:
OEM String : Cisco Systems, Inc.
Product Number : N5K-PAC-200W
Serial Number : PAC12473L17
Part Number : 341-0335-01
snmpOID : 0.0.0.0.0.0.0.0
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show startup-config exclude-provision
To display the startup configuration that excludes the configuration for offline preprovisioned interfaces, use the show startup-config exclude-provision command.
show startup-config exclude-provision
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the startup configuration without the offline preprovisioned interfaces:
switch# show startup-config exclude-provision
Related Commands
|
|
provision |
Preprovisions a module in a slot. |
show provision |
Displays the preprovisioned module information. |
show running-config exclude-provision |
Displays the running configuration excluding the preprovisioned features. |
slot |
Configures a chassis slot for a predefined module. |
show system reset-reason fex
To display the reason for the last reset of the Fabric Extender, use the show system reset-reason fex command.
show system reset-reason fex chassis_ID
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display the last reset reason for a specific Fabric Extender:
switch# show system reset-reason fex 100
----- reset reason for FEX 100 ---
1) At 430815 usecs after Fri Apr 16 04:27:04 2010
Reset Reason: Reset Requested by CLI command reload (9)
Service (Additional Info): Reload requested by supervisor
Image Version: 4.2(1)N1(1)
2) At 505550 usecs after Fri Apr 16 03:39:50 2010
Reset Reason: Reset due to upgrade (88)
Service (Additional Info): Reset due to upgrade
Image Version: 4.2(1u)N1(1u)
3) At 607267 usecs after Fri Apr 16 02:50:10 2010
Reset Reason: Reset due to upgrade (88)
Service (Additional Info): Reset due to upgrade
Image Version: 4.2(1)N1(1)
4) At 857790 usecs after Fri Apr 16 02:00:22 2010
Reset Reason: Reset due to upgrade (88)
Service (Additional Info): Reset due to upgrade
Image Version: 4.2(1u)N1(1u)
Related Commands
|
|
show fex |
Displays all configured Fabric Extender chassis connected to the switch. |
show version fex
To display the software version information about a Fabric Extender, use the show version fex command.
show version fex chassis_ID
Syntax Description
chassis_ID |
Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
Command Modes
EXEC mode
Command History
|
|
4.2(1)N1(1) |
This command was introduced. |
Examples
This example shows how to display the software version of a Fabric Extender:
switch# show version fex 100
System boot mode: primary
System image version: 4.2(1)N2(1) [build 4.2(1)N2(1)]
Module: Fabric Extender 48x1GE Module
Serial number: JAF1302ABDP
Kernel uptime is 0 day(s), 9 hour(s), 9 minutes(s), 16 second(s)
Last reset at Fri Jul 02 04:27:04 2010
Reason: Reset Requested by CLI command reload
Service: Reload requested by supervisor
Related Commands
|
|
show fex |