Technical Specifications
This appendix provides router, port, cabling specifications, and power adapters for the Cisco IR829 Integrated Services Router (ISRs).
NOTE : For compliance and safety information, see the Regulatory Compliance and Safety Information for Cisco IR800 Series Routers
Router Specifications
The following tables list the operational limits of the Cisco IR829. Operating the router outside of the limits specified is not supported.
Description |
Design Specification |
---|---|
Standard Safety Certifications |
UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1, 2nd edition, EN 60950-1, 2nd edition; CB to IEC 60950-1, 2nd edition with all group differences and national deviations |
Description |
Design Specification |
---|---|
Dimensions (H x W x D) |
(height x width x depth) are 7.70 x 11 x 1.73 in. (19.6 x 27.9 x 4.39 cm). |
Weight |
5 lb (2.26 kg) |
Maximum Power Consumption |
70 Watts with PoE |
Description |
Design Specification |
---|---|
Ingress Protection Rating |
IP 40 per IEC 60529 for Vertical Falling Water, Pollution Degree 3 |
Humidity |
Non-condensing Relative Humidity: 5% to 95% |
Military Standard |
MIL-STD-810G Method 514.6: Procedure 1 Category 4, Secured Cargo - Common MIL-STD-810G Method 514.6: Procedure 1 Category 20, Ground Vehicles MIL-STD-810G Method 516.6. Procedure 1, Functional Shock MIL-STD-810G Method 516.6. Procedure 5, Crash Hazard MIL-STD-810G Method 516.6. Procedure 6, Bench Handling |
Vibration and Shock (Railway Vehicles) |
EN61373 Functional Random Vibe - Category 1, Class B EN61373 Simulated Non-op Long-life Vibe - Category 1, Class B EN61373 Non-op Shock, Class B |
Heavy-Duty Vehicle Applications |
SAE J1455 Operating Random Vibe, Cab Mounted Truck SAE J1455 Operating Sinusoidal Vibe, Category 3 SAE J1455 Non-operating Sinusoidal Vibe, Category 3 SAE J1455 Handling Drop Test |
Description |
Design Specification |
---|---|
Operating Temperature and Altitude |
-40° to 140°F (-40° to 60°C) in a sealed NEMA cabinet with no airflow -40° to 158°F (-40° to 70°C) in a vented cabinet with 40 lfm of air -29° to 167°F (-34° to 75°C) in a forced air enclosure with 200 lfm of air (type tested at +85C for 16 hours) -500 to 5,000 feet. Derate max operating temperature 1.5°C per 1000 feet. 10,000 ft maximum |
Humidity |
10% — 95% non-condensing |