Guest

Cisco ONS 15454 Series Multiservice Provisioning Platforms

FMECBlank

  • Viewing Options

  • PDF (364.4 KB)
  • Feedback
Installing the Cisco ONS 15454 SDH FMEC Blank Card

Table Of Contents

Installing the Cisco ONS 15454 SDH FMEC Blank Card

FMEC Blank Card Description

FMEC Blank Card Specifications

Install the FMEC Blank Card

Related Documentation

Obtaining Documentation and Submitting a Service Request


Installing the Cisco ONS 15454 SDH FMEC Blank Card


Product Name: 15454E-BLANK-FMEC

This document contains a description of FMEC Blank card features, installation procedures, and technical specifications. Use this document in conjunction with the Cisco ONS 15454 SDH Reference Manual and the Cisco ONS 15454 SDH Procedure Guide when working with FMEC Blank cards.

This document contains the following sections:

FMEC Blank Card Description

FMEC Blank Card Specifications

Install the FMEC Blank Card

Related Documentation

Obtaining Documentation and Submitting a Service Request


Note For information about circuits and card capacities, see the Cisco ONS 15454 SDH Reference Manual.


FMEC Blank Card Description

The FMEC-BLANK card provides EMC emission control for empty FMEC slots. It also provides a way to close off the EFCA area, thus allowing air flow and convection to be maintained through the EFCA. Figure 1 shows the FMEC-BLANK card faceplate.

You have to install the BLANK FMEC in every empty FMEC slot to maintain EMC requirements of the system and proper air flow.

Figure 1 FMEC-BLANK Faceplate

FMEC Blank Card Specifications

The FMEC-BLANK card has the following specifications:

Environmental

Operating temperature: Not applicable

Operating humidity: Not applicable

Power consumption: Not applicable

Dimensions

Height: 182 mm (7.165 in.)

Width: 32 mm (1.25 in.)

Weight not including clam shell: 0.2 kg (0.4 lb)

Install the FMEC Blank Card

Use this section if you are installing or removing the FMEC Blank card for the first time. After you become familiar with ONS 15454 SDH card installation, use this section as a reference.


Caution Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded.


Caution Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution when servicing.

Figure 2 shows general card installation.

Figure 2 Installing a FMEC card in an ONS 15454 SDH


Step 1 Carefully insert the card into the rails of the desired slot (Figure 2). Move the upper ejector down and the lower ejector up to enable the card being inserted properly into the slot.

Step 2 Tighten the front mounting screws with a Phillips or slot screwdriver.

Stop. You have completed this procedure.


Related Documentation

Cisco ONS 15454 SDH Procedure Guide

Cisco ONS 15454 SDH Reference Manual

Obtaining Documentation and Submitting a Service Request

For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

Subscribe to the What's New in Cisco Product Documentation as an RSS feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service. Cisco currently supports RSS Version 2.0.

This document is to be used in conjunction with the documents listed in the "Related Documentation" section.