The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
From the WAE Design GUI, you can extract.pln plan files from a remote WAE Core server1, make whatever modifications are necessary, and re-insert them to the remote server. It is important to note that these plan files are not stored with the plan files generated by WAE Collector.
The Network Modeler Module (on the WAE Core server) contains the working plan file, which represents the current state of the network. It can also contain one or more staging areas, where each staging area enables you to work on plan files before deploying them.
Saving the plan file to the working area of the Network Modeler Module overwrites the existing plan file. This means that any newly discovered or recently modified plan files are overwritten. For this reason, if you are not deploying the plan file, it is a best practice to access a staging area.
Note It is strongly recommended that you verify a plan file before deploying it to the network.
/opt/cariden/software/wae-core/etc/com.cisco.wano.nsps.nbrs.cfg
file must either have the authenticationEnabled property set to false, or you must know the values entered as the username and password properties.Step 1 Use the File menu to start the process.
Step 2 After opening the dialog box, enter the hostname or IP address of the server.
Step 3 Identify how to connect to the server by selecting the appropriate protocol and entering the port number (for example, HTTP 7777).
Step 4 If the authentication is enabled, enter the same username and password.
Step 5 Optional: Save the data you entered for future use.
Step 6 If using a staging area for this access, enter the stage ID number.
Step 7 If saving a plan file, select the operation, as follows.