This document provides sample configurations on Inter-Switch Link (ISL) between a Catalyst 5500 and a Catalyst 5000 switch, both running Catalyst OS (CatOS). Any Catalyst 5000 or 6000 family member running CatOS could be used in this scenario to obtain the same results.

Briefly, trunking is a way to carry traffic from several VLANs over a point-to-point link between the two devices. There are two ways in which Ethernet trunking can be implemented:

  • ISL (Cisco proprietary Inter-Switch Link protocol)

  • 802.1Q (IEEE standard)

This document will only show the configuration files from the switches and the output from the related sample show commands. For details on how to configure an ISL trunk between the Catalyst switches, refer to Configuring ISL Trunking on Catalyst 5500/5000 and 6500/6000 Family Switches.

Prerequisites

Requirements

There are no specific requirements for this document.

Components Used

The information in this document is based on these software and hardware versions:

  • Catalyst 5500 switch running Catalyst OS 6.1(1) software

  • Catalyst 5000 switch running Catalyst OS 6.1(1) software

The information in this document was created from the devices in a specific lab environment. If your network is live, make sure that you understand the potential impact of any command. The configurations on all devices were cleared with the clear config all and write erase commands to ensure that they had a default configuration.

Conventions

For more information on document conventions, refer to the Cisco Technical Tips Conventions .

Important Notes

The Catalyst 4000 family (including Catalyst 2948G and Catalyst 2980G) running CatOS only supports 802.1Q trunking, not ISL trunking.

Any Ethernet port on a Catalyst 6000 family member supports 802.1Q and ISL encapsulation.

Depending on the module, Catalyst 5000 trunk-capable ports may support only ISL encapsulation or both ISL and 802.1Q. The best way to verify this is to issue the show port capabilities command. The trunking capacity is explicitly stated. For example:

cat5000> show port capabilities 3

Model                    WS-X5225R
Port                     3/1
Type                     10/100BaseTX
Speed                    auto,10,100
Duplex                   half,full
Trunk encap type         802.1Q,ISL
Trunk mode               on,off,desirable,auto,nonegotiate
Channel                  3/1-2,3/1-4
Broadcast suppression    percentage(0-100)
Flow control             receive-(off,on),send-(off,on)
Security                 yes
Membership               static,dynamic
Fast start               yes
QOS scheduling           rx-(none),tx-(none)
CoS rewrite              yes
ToS rewrite              IP-Precedence
Rewrite                  no
UDLD                     yes
AuxiliaryVlan            1..1000,1025..4094,untagged,dot1p,none
SPAN                     source,destination

Ensure that the trunking modes match across the trunk link. If one side of the link is configured as an ISL trunk, the other side of the link should also be configured as ISL; similarly, if one side of the link is configured as 802.1Q, the other side of the link should also be configured as 802.1Q.

Configure

In this section, you are presented with the information to configure the features described in this document.

Note: To find additional information on the commands used in this document, use the Command Lookup Tool (registered customers only) .

Network Diagram

This document uses this network setup:

69.gif

Configurations

This document uses these configurations:

Catalyst 5500
#version 6.1(1)
!
set option fddi-user-pri enabled
set password $2$q.J7$O5n.pwx7aEC6NHWJfXadx1
set enablepass $2$o.h/$bAxfjJ4XUA/RMUHqBr1YQ0
!
#errordetection
set errordetection portcounter enable
!
#system
set system name  cat5500
!
#frame distribution method
set port channel all distribution mac both
!
#vtp

!--- In this example, the VLAN Trunking Protocol (VTP) mode is set to be transparent.
!--- Depending on your network, set the VTP mode accordingly.

set vtp mode transparent

!--- For details on VTP, refer to Configuring VTP.

set vlan 1 name default type ethernet mtu 1500 said 100001 state active
set vlan 1002 name fddi-default type fddi mtu 1500 said 101002 state active
set vlan 1004 name fddinet-default type fddinet mtu 1500 said 101004 state active stp ieee
set vlan 1005 name trnet-default type trbrf mtu 1500 said 101005 state active stp ibm
set vlan 2
set vlan 1003 name token-ring-default type trcrf mtu 1500 said 101003 state acti
ve mode srb aremaxhop 7 stemaxhop 7 backupcrf off
!
#ip

!--- IP address used for management.

set interface sc0 1 10.10.10.2/255.255.255.0 10.10.10.255
!
#set boot command
set boot config-register 0x2102
set boot system flash slot0:cat5000-sup3.6-1-1.bin
!
# default port status is enable
!
!
#module 1 empty
!
#module 2 : 2-port 1000BaseSX Supervisor
!
#module 3 empty
!
#module 4 : 24-port 10/100BaseTX Ethernet

!--- Ports 4/13-24 are assigned to VLAN 2.

set vlan 2 4/13-24

!--- The ISL trunking mode is set to on.
!--- Depending on your network and requirements, set the trunking mode accordingly.

set trunk 4/1 on isl 1-1005

!--- For details on different trunking modes, refer to
!--- Configuring VLAN Trunks on Fast Ethernet and Gigabit Ethernet Ports
!--- Portfast has been enabled on the ports connected to the workstations.

set spantree portfast 4/2-24 enable

!--- For details on why to enable portfast, refer to
!--- Using Portfast and Other Commands to Fix Workstation Startup Connectivity Delays


!
#module 5 empty
!
#module 6 empty
!
#module 7 empty
!
#module 8 empty
!
#module 9 empty
!
#module 10 empty
!
#module 11 empty
!
#module 12 empty
!
#module 13 empty
end

Catalyst 5000
#Version 6.1(1)
!
set option fddi-user-pri enabled
set password $2$J75L$Ug4163kfeHTDcLJZ/L9es1
set enablepass $2$h/BN$i3S54iNvIXknFelh6gOve0
!
#errordetection
set errordetection portcounter enable
!
#system
set system name  cat5000
!
#frame distribution method
set port channel all distribution Mac both
!
#vtp

!--- In this example, the VTP mode is set to be transparent.
!--- Depending on your network and requirements, set the VTP mode accordingly.

set vtp mode transparent

!--- For details on VTP, refer to Configuring VTP.

set vlan 1 name default type ethernet mtu 1500 said 100001 state active
set vlan 1002 name fddi-default type fddi mtu 1500 said 101002 state active
set vlan 1004 name fddinet-default type fddinet mtu 1500 said 101004 state active stp IEEE
set vlan 1005 name trnet-default type trbrf mtu 1500 said 101005 state active stp IBM
set vlan 2
set vlan 1003 name token-ring-default type trcrf mtu 1500 said 101003 state acti
ve mode srb aremaxhop 7 stemaxhop 7 backupcrf off
!
#ip

!--- IP address used for management.

set interface sc0 1 10.10.10.3/255.255.255.0 10.10.10.255
!
#set boot command
set boot config-register 0x2102
set boot system flash slot0:cat5000-sup3.6-1-1.bin
!
# default port status is enable
!
!
#module 1 : 0-port Supervisor III
!
#module 2 : 12-port 10/100BaseTX Ethernet
!
#module 3 : 24-port 10/100BaseTX Ethernet

!--- Ports 3/13-24 have been assigned to VLAN 2.

set vlan 2 3/13-24

!--- The ISL trunking mode is set to on.
!--- Depending on your network and requirements, set the trunking mode accordingly.

set trunk 3/1 on isl 1-1005

!--- For details on different trunking modes, refer to
!--- Configuring VLAN Trunks on Fast Ethernet and Gigabit Ethernet Ports
!--- Portfast has been enabled on the ports connected to the workstations.

set spantree portfast 3/2-24 enable

!--- For details on why to enable portfast, refer to
!--- Using Portfast and Other Commands to Fix Workstation Startup Connectivity Delays


!
!
#module 4 : 24-port 10/100BaseTX Ethernet
!
#module 5 : 12-port 10BaseFL Ethernet
end

Verify

This section provides information you can use to confirm your configuration is working properly.

Certain show commands—in particular, show tech-support—are supported by the Output Interpreter Tool (registered customers only) , which allows you to view an analysis of show command output.

Catalyst 5500 Switch

show port capabilities module/port —Issue this command to verify whether the port is capable of trunking.

cat5500> (enable)  show port capabilities 4/1

Model                    WS-X5234
Port                     4/1
Type                     10/100BaseTX
Speed                    auto,10,100
Duplex                   half,full
Trunk encap type         802.1Q,ISL
Trunk mode               on,off,desirable,auto,nonegotiate
Channel                  4/1-2,4/1-4
Broadcast suppression    percentage(0-100)
Flow control             receive-(off,on),send-(off,on)
Security                 yes
Membership               static,dynamic
Fast start               yes
QOS scheduling           rx-(none),TX(1q4t)
COs rewrite              yes
ToS rewrite              IP-Precedence
Rewrite                  no
UDLD                     yes
AuxiliaryVlan            1..1000,1025..4094,untagged,dot1p,none
SPAN                     source,destination

show port module/port —Issue this command to determine the status of a particular port and whether or not it is trunking.

cat5500> (enable) show port 4/1

Port  Name               Status     Vlan       Level  Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
 4/1                     connected  trunk      normal a-full a-100 10/100BaseTX

Port  AuxiliaryVlan AuxVlan-Status
----- ------------- --------------
 4/1  none          none

Port  Security Violation Shutdown-Time Age-Time Max-Addr Trap     IfIndex
----- -------- --------- ------------- -------- -------- -------- -------
 4/1  disabled  shutdown             0        0        1 disabled      11

Port  Num-Addr Secure-Src-Addr   Age-Left Last-Src-Addr     Shutdown/Time-Left
----- -------- ----------------- -------- ----------------- ------------------
 4/1         0                 -        -                 -        -         -

!--- Output suppressed.

show trunk—Issue this command to verify the trunking status and configuration.

cat5500> (enable) show trunk

* - indicates vtp domain mismatch
Port      Mode         Encapsulation  Status        Native vlan
--------  -----------  -------------  ------------  -----------
4/1      on           isl            trunking      1

Port      Vlans allowed on trunk
--------  ---------------------------------------------------------------------
 4/1      1-1005

Port      Vlans allowed and active in management domain
--------  ---------------------------------------------------------------------
 4/1      1-2

Port      Vlans in spanning tree forwarding state and not pruned
--------  ---------------------------------------------------------------------
 4/1      1-2

show vtp domain—Issue this command to check the VTP information.

cat5500> (enable) show vtp domain

Domain Name                      Domain Index VTP Version Local Mode  Password
-------------------------------- ------------ ----------- ----------- ----------
                                 1            2           Transparent -

Vlan-count Max-vlan-storage Config Revision Notifications
---------- ---------------- --------------- -------------
6          1023             0               disabled

Last Updater    V2 Mode  Pruning  PruneEligible on Vlans
--------------- -------- -------- -------------------------
10.10.10.2      disabled disabled 2-1000

Catalyst 5000 Switch

show port capabilities module/port —Issue this command to verify whether the port is capable of trunking.

cat5000> (enable) show port capabilities 3/1

Model                    WS-X5225R
Port                     3/1
Type                     10/100BaseTX
Speed                    auto,10,100
Duplex                   half,full
Trunk encap type         802.1Q,ISL
Trunk mode               on,off,desirable,auto,nonegotiate
Channel                  3/1-2,3/1-4
Broadcast suppression    percentage(0-100)
Flow control             receive-(off,on),send-(off,on)
Security                 yes
Membership               static,dynamic
Fast start               yes
QOS scheduling           rx-(none),TX(none)
COs rewrite              yes
ToS rewrite              IP-Precedence
Rewrite                  no
UDLD                     yes
AuxiliaryVlan            1..1000,1025..4094,untagged,dot1p,none
SPAN                     source,destination

show port module/port —Issue this command to determine the status of a particular port and whether or not it is trunking.

cat5000> (enable) show port 3/1

Port  Name               Status     Vlan       Level  Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
 3/1                     connected  trunk      normal a-full a-100 10/100BaseTX

Port  AuxiliaryVlan AuxVlan-Status
----- ------------- --------------
 3/1  none          none

Port  Security Violation Shutdown-Time Age-Time Max-Addr Trap     IfIndex
----- -------- --------- ------------- -------- -------- -------- -------
 3/1  disabled  shutdown             0        0        1 disabled      57

!--- Output suppressed.

show trunk—Issue this command to verify the trunking status and configuration.

cat5000> (enable) show trunk

* - indicates vtp domain mismatch
Port      Mode         Encapsulation  Status        Native vlan
--------  -----------  -------------  ------------  -----------
 3/1      on           isl            trunking      1

Port      Vlans allowed on trunk
--------  ---------------------------------------------------------------------
 3/1      1-1005

Port      Vlans allowed and active in management domain
--------  ---------------------------------------------------------------------
 3/1      1-2

Port      Vlans in spanning tree forwarding state and not pruned
--------  ---------------------------------------------------------------------
 3/1      1-2

show vtp domain—Issue this command to check the VTP information.

cat5000> (enable) show vtp domain

Domain Name                      Domain Index VTP Version Local Mode  Password
-------------------------------- ------------ ----------- ----------- ----------
                                 1            2           Transparent -

Vlan-count Max-vlan-storage Config Revision Notifications
---------- ---------------- --------------- -------------
6          1023             0               disabled

Last Updater    V2 Mode  Pruning  PruneEligible on Vlans
--------------- -------- -------- -------------------------
10.10.10.3      disabled disabled 2-1000

Troubleshoot

There is currently no specific troubleshooting information available for this configuration.

Related Information

Updated: Aug 30, 2005
Document ID: 8753