Guest

Cisco ONS 15454 Series Multiservice Provisioning Platforms

ONS15454 G1000-4 Card Ports Provisioned with an STS-24c Circuit May Cause CRC Errors


April 17, 2003



Products Affected

Product

Top Assembly

Printed Circuit Assembly

Part Number

Rev.

Part Number

Rev.

15454-G1000-4

15454-G1000-4=

800-08578-02

B0

73-5561-07

C0

Problem Description

CRC errors on G1000-4 cards when egress SONET payloads are greater than Gigabit Ethernet line rates (1.0 Gbps).

Background

With the introduction of the ML1000-2 card it is now possible to create SONET circuits with full utilization above Gigabit Ethernet line rate (the STS-24c has a 1.24 Gbps payload capacity). When such a payload is cross connected to the G1000-4 card for sustained periods, the G1000-4 card frame buffers fill up and can ultimately lead to CRC errors because of the limitation in the G1000-4 hardware.

Problem Symptoms

CRC errors experienced on Gigabit Ethernet client interfaces.

Workaround/Solution

Avoid using SONET traffic greater that 1 Gbps line rate or STS24c when using more than one circuit. There is no problem with the STS-24c circuits. The issue is caused by the limitation of this card. This has been fixed with an upgrade to the FPGA in the G1K-4 card.

DDTS

To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.

DDTS

Description

CSCdy02928 (registered customers only)

G1000 problem with sonet traffic greater than GIGE line rate.

This DDTS also applies to a field notice for the ONS 15327. That field notice can be found here.

For More Information