Guest

Cisco WAN Switching Modules

Field Notice: ABR Traffic Continuity Problem after switchyred


August 9, 2001


Products Affected

Product

Comments

BPX-BXM

All Models with Firmware MFH or earlier.

BPX-BXM-E

All Models with Firmware MFH or earlier.

Problem Description

In redundant configurations, the standby Broadband Switch Module (BXM) may not be programmed with Available Bit Rate (ABR) connections which use Private Network-to-Network Interface (PNNI) partitions.

Background

This problem manifests only if all the following conditions are met:

  • This problem will only occur in the networks that already have PNNI-ABR conns.

  • BXM or Enhanced Broadband Switching Module (BXM-E) must have MFH firmware or earlier.

  • Redundancy is added after ABR connections are added or the redundant card is not installed when ABR connection is added.

Problem Symptoms

The most observable symptom occurs when a recently upgraded BXM redundant pair experience a switchyred and ABR connections using PNNI routing lose connectivity.

Workaround/Solution

Upgrade BXM or BXM-E to MFJ or later. Firmware MFJ may be obtained from CCO. Read BXM firmware release notes before upgrading from release firmware MEC (inclusive) and prior releases.

DDTS

To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.

DDTS

Description

CSCds53645

ABR con have traffic continuity problem in case of switchyred.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:

Receive Email Notification For New Field Notices

Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.