Cisco Transceiver Modules

10GBASE-E and 10GBASE-L White Paper

  • Viewing Options

  • PDF (88.9 KB)
  • Feedback
dWhite Paper

GLOSSARY

APC

Angled Polished Connectors

Er

Extinction Ratio

OMA

Optical Modulation Amplitude

ORL

Optical Return Loss

OTDR

Optical Time Domain Reflectometer

CD

Chromatic Dispersion

PC

Polished Connectors

UPC

Ultra Polished Connectors

ABSTRACT

The 10 Gigabit Ethernet optical interfaces defined by IEEE 802.3 have a relatively complex set of requirements and parameters that ensure interoperability and allow for cost-effective implementations. Some of the optical parameters and procedures defined by the IEEE 802.3ae-2002 document depart from the traditional Gigabit Ethernet and SONET/SDH. Implementers need to understand which are the necessary criteria for compliance to correctly use legacy handheld equipment to qualify and configure a 10 Gigabit Ethernet optical link.
This paper clarifies the IEEE 802.3ae-2002 optical requirements and presents engineering rules to guide the successful deployment of IEEE 802.3ae-2002 compatible 10GBASE-L and 10GBASE-E optical interfaces across Cisco ® switches and routers.
There are two aspects to deploying these links: the fiber plant and the optical transceivers. Accordingly, the first section of this paper deals with the underlying fiber plant. It presents the set of criteria for qualifying the fiber infrastructure. When satisfied, these criteria allow for plug-and-play of the 10 Gigabit Ethernet interfaces.
The second section looks at the optical transceivers, starting with the theoretical background for the 10 Gigabit Ethernet optical parameters defined in IEEE 802.3ae-2002. We then look at the two interfaces of concern, namely 10GBASE-E and 10GBASE-L, and present their specific optical parameters highlighting the mandatory and informative requirements. This section also presents and explains pass/fail criteria to accept and troubleshoot 10 Gigabit Ethernet optical transceivers.
The Appendix presents the theory in more detail by showing some numerical examples and figures.

GUIDELINES TO VALIDATING A 10 GIGABIT ETHERNET FIBER PLANT

The intent of this section is to minimize the amount of optical design required to set up an IEEE 802.3ae-2002 10 Gigabit Ethernet link. In general, as long as the fiber plant has certain well-known characteristics, from an operational perspective we can treat 10GBASE-E and 10GBASE-L as "plug and play" devices with minimal link engineering design required.
The following table reports all you need to know to successfully install and maintain a 10 Gigabit Ethernet single-mode fiber plant.

Table 1. Fiber Plant Testing Criteria for 10GBASE-E and 10GBASE-L

Criterion

10GBASE-E

10GBASE-L

Validation Method

Fiber

ITU-T G.652

ITU-T G.652

Check with fiber vendor

Patch Cords and Fiber Cable Connectors Connecting to the Transceiver

PC/UPC

PC/UPC

Visual inspection:

Green: APC-NOT OK*
Blue: UPC-OK
Black: PC-OK
Channel Insertion Loss** (min-max)

5-11 dB

0-6 dB

Modern optical time domain reflectometers (OTDRs) are capable of performing all these measurements in an automated fashion.

Distance

40 km

10 km

Total Optical Return Loss*** (ORL max)

≥ 21 dB

≥ 21 dB

Maximum Reflectance (for each connector/splice)

≤ -26 dB

≤ -26 dB

* Using APC connectors can severely degrade the performance.
** Channel insertion loss computed as total sum of connectors + fiber + splice(s) attenuation.
*** ORL includes both connectors and fiber.
In most cases, the above information should be sufficient to qualify your fiber plant to run a 10GBASE-E or 10GBASE-L link. A modern OTDR can be used to validate the fiber plant parameters.
The chromatic dispersion requirements of 10GBASE-ER allow for up to 40 km of any G.652 compliant fiber.

IEEE 10 GIGABIT ETHERNET OPTICAL PARAMETERS: CRITERIA FOR ACCEPTANCE TESTING

For a basic pass/fail testing of optical transceivers, end users have traditionally validated the transmit power and receiver sensitivity against the minimum transmit power and maximum receiver sensitivity reported in the data sheet. For example, an end user of a XENPAK-10GB-ER would look up a minimum transmit power of -4.7 dBm and receiver sensitivity of -15.8 dBm. Moreover, it is common practice to take the difference of these two numbers to compute the power budget available and compare it against either the budget reported by the standard or the budget available to a particular fiber plant.
This rule-of-thumb methodology has worked well for Ethernet interfaces that operate at lower signaling speed. For 10 Gigabit Ethernet interfaces, such an approach will not work. The underlying reason, to be detailed in this section, is that the IEEE 802.3ae-2002 standard affords implementers an extra degree of flexibility in building the optical transmitters. This allows optical manufacturers to build more cost-effective implementations that are capable of robust 10 Gigabit data communications. Nevertheless, this violates some of the underlying basic assumptions that have allowed us to simply just look at the transmit power and receiver sensitivity.
This section first reviews the underlying theory at play and compares what the legacy and new parameters are measuring. Then it covers the specific numerical values that 10GBASE-E or 10GBASE-L take on. The Appendix presents more numerical examples and details.

OMA, TRANSMIT POWER, AND EXTINCTION RATIO

The transmitter side of the optical specification for Gigabit Ethernet, typically found under the transmit table of the PMD to MDI specification in 802.3 documents, reports two mandatory parameters in the 1000BASE-LX transmit table:

• Average launch power (min)

• Extinction ratio (min)

The extinction ratio (Er) is defined as the ratio of the power to transmit a "1" symbol to the power to transmit a "0" signal. Together, these values are used to describe the content strength of the signal that the transmitter puts on the wire. It is necessary but not sufficient to look at the average launch power-how strong the light is. We need to also consider the difference between the two digital levels (zero and one) that the transmitter puts out to properly assess the signal-to-noise ratio at the other end of the link.
The argument above presents an interesting question. Can we trade off launch power for extinction ratio, and vice versa, while maintaining the quality of the link? The answer is yes.
This answer makes intuitive sense as one can see how at higher extinction ratios less power would be needed to overcome the impediments in the channel while maintaining the same quality of the link. To that effect IEEE 802.3ae-2002 introduces a new mandatory measurement called OMA (optical modulation amplitude), which is the difference between the optical power in the ones and the optical power in the zeros. It is related to the average power Pout and the extinction ratio Er and summarizes them into one measurement:
OMA = 2P out(Er - 1)/(Er + 1)
where P out is the optical power in milliwatts and Er is the extinction ratio reported as a pure ratio.
Note the following two points about the three quantities:

• By definition, fixing two of the quantities automatically generates the third quantity as they are related through a linear mathematical equation, thus one only needs to measure two quantities at any one point.

• To satisfy a minimum OMA, a range of power and extinction ratio numbers can be found.

The IEEE 802.3ae-2002 standard requires a minimum OMA and minimum Er but does not mandate a minimum average transmit power, because that number depends on the actual value of the Er that the manufacturer produces. Put differently, the standard clearly states that the average transmit power value is an informative quantity, and a value within spec does not necessarily guarantee that the optic is standard-compliant. Instead, the standard defines the lower possible bound of the range that could satisfy the OMA, given the proper Er. For example, in the case of 10GBASE-E a value of transmit power below -4.7 dBm (min Tx power) cannot be compliant; however, a value above -4.7 dBm does not ensure compliance either.
So why do this? Again, the answer is to give flexibility to the designers of the modules. So why even mention minimum power in the data sheet? It happens that this is the only characteristic of the optical signals that is measurable with standard legacy field equipment. End users should not rely solely on the power number as a pass/fail acceptance criteria. For that a digital oscilloscope to measure Er and calculate OMA is mandatory.
Similarly, the average received power is considered an informative quantity, and receiver sensitivity is specified as an OMA number in the Standard.
So what actually guarantees compliance with the standard? It is time to take a deeper look at the IEEE strategy to define optical parameters.

10GBASE-L AND 10GBASE-E PARAMETERS

Table 2 summarizes the requirements for 10GBASE-L and 10GBASE-E. In the language of the standard, "normative" is equivalent to mandatory and "informative" is for informational consumption only.

Table 2. IEEE OMA and Er Specifications for 10GBASE-L and 10GBASE-E

Parameter

10GBASE-L

10GBASE-E

Parameter Class

Tx OMA Min

-5.2 dBm

-1.7 dBm

Mandatory IEEE requirements

Rx Sensitivity in OMA

-12.6 dBm

-14.1 dBm

Er

≥ 3.5 dB

≥ 3 dB

Min Launch Power

-8.2 dBm

-4.7 dBm

Informative IEEE limits

Min Rx Power

-14.4 dBm

-15.7 dBm

The available power budget in a link can be allocated to channel insertion loss, which in single mode point-to-point links such as these, is determined by the fiber attenuation, and penalties. Note that unlike SONET, penalties of the transmitter are accounted for as well as power penalty. The allocation for penalties is typically calculated by subtracting the channel insertion loss from the available budget. Keep in mind that the link power budget tables presented in the Standard (Table 3) are informative and serve only as a guideline to what should be expected. Moreover, keep in mind that these quantities are recorded for a specific example of a link. In practice, the actual attenuation of the fiber plant and the penalties vary, so these numbers should not be taken as a hard and fast rule.

Table 3. IEEE Power Budgets for 10GBASE-L and 10-GBASE-E

Budget Breakdown

10GBASE-L

10GBASE-E

Power Budget

9.2 dB

15 dB

Channel Loss at the Maximum Distance (fiber, connectors, splices)

6 dB

11 dB

Allocation for Penalties

3.2 dB

4 dB

The way that these power budgets and penalties are calculated is outside the scope of this paper; however, the official 10 Gigabit Ethernet link model calculator can be accessed at http://www.ieee802.org/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls.
For further information on the link model refer also to: "Review of the 10Gigabit Ethernet Link Model" by David Cunningham & Piers Dawe, http://literature.agilent.com/litweb/pdf/5988-5908EN.pdf
Note that the channel insertion loss numbers match what we presented in the first section on the fiber plant. Also, the power budget numbers are computed at the minimum transmitted OMA.
To summarize, the power budget numbers presented in the IEEE document are informative and only reflect a particular scenario. The IEEE specifies a minimum ER and minimum OMA but does not mandate the power requirement. The actual power budget for a particular link will depend on the actual performance of the transceiver and the losses and dispersion of the fiber plant.

APPENDIX

An Introduction to Extinction Ratio (Er)

Er is defined as the ratio of the power to transmit a "1" symbol to the power to transmit a "0" symbol:
Er = P 1/P 0
The greater the distance is between P 1 and P 0 the easier it is for the receiver to distinguish a one from a zero. Unfortunately, building transmitters with a high Er is more challenging and costly. In practice, transmitters are always on, even when transmitting zeros, and the higher is P 0 (and the lower is P 1) the easier and less expensive is the design of the transmitter.
By specifying the OMA, IEEE gives manufacturers of modules two degrees of freedom: optical power and extinction ratio. One can satisfy the OMA by trading off P out against Er.
Although OMA may not be a convenient parameter to measure in the field, it is a more accurate representation of the quality of the signal than the P out alone. The whole idea boils down to: "You need to scream louder (higher P out) if you have noise in the room (Er smaller)."
To measure Er a digital oscilloscope is required. Er is part of a variety of eye diagram measurements performed by the oscilloscope (Figure 1).

Figure 1. Typical Oscilloscope Eye Diagram Measurement and P1, P0

For a more detailed treatment of Er and OMA, see: http://pdfserv.maxim-ic.com/en/an/3hfan222.pdf

About the Authors

Wael William Diab
Technical Leader, Cisco Systems
Secretary, IEEE 802.3 CSMA/CD Working Group (Ethernet) Chief Editor, IEEE 802.3ah (Ethernet in the First Mile)
Piers Dawe
Agilent Technologies
Vice-Chair, Optics Sub Task Force, IEEE 802.3ah (Ethernet in the First Mile)
Alessandro Barbieri
Product Manager, Ethernet Systems Group, Cisco Systems
Text Box:  Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAwww.cisco.comTel:	408 526-4000	800 553-NETS (6387)Fax:	408 526-4100	European HeadquartersCisco Systems International BVHaarlerbergparkHaarlerbergweg 13-191101 CH AmsterdamThe Netherlandswww-europe.cisco.comTel:	31 0 20 357 1000Fax:	31 0 20 357 1100	Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAwww.cisco.comTel:	408 526-7660Fax:	408 527-0883	Asia Pacific HeadquartersCisco Systems, Inc.168 Robinson Road#28-01 Capital TowerSingapore 068912www.cisco.comTel: +65 6317 7777Fax: +65 6317 7799Cisco Systems has more than 200 offices in the following countries and regions. Addresses, phone numbers, and fax numbers are listed onthe Cisco Website at www.cisco.com/go/offices.Argentina · Australia · Austria · Belgium · Brazil · Bulgaria · Canada · Chile · China PRC · Colombia · Costa Rica · Croatia · Cyprus Czech Republic · Denmark · Dubai, UAE · Finland · France · Germany · Greece · Hong Kong SAR · Hungary · India · Indonesia · Ireland · Israel Italy · Japan · Korea · Luxembourg · Malaysia · Mexico · The Netherlands · New Zealand · Norway · Peru · Philippines · Poland · Portugal Puerto Rico · Romania · Russia · Saudi Arabia · Scotland · Singapore · Slovakia · Slovenia · South Africa · Spain · Sweden · Switzerland · Taiwan Thailand · Turkey · Ukraine · United Kingdom · United States · Venezuela · Vietnam · ZimbabweCopyright  2005 Cisco Systems, Inc. All rights reserved. CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StrataView Plus, TeleRouter, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0502R)	205482.CE_ETMG_CC_11.05Printed in the USA Text Box:  Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAwww.cisco.comTel:	408 526-4000	800 553-NETS (6387)Fax:	408 526-4100	European HeadquartersCisco Systems International BVHaarlerbergparkHaarlerbergweg 13-191101 CH AmsterdamThe Netherlandswww-europe.cisco.comTel:	31 0 20 357 1000Fax:	31 0 20 357 1100	Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAwww.cisco.comTel:	408 526-7660Fax:	408 527-0883	Asia Pacific HeadquartersCisco Systems, Inc.168 Robinson Road#28-01 Capital TowerSingapore 068912www.cisco.comTel: +65 6317 7777Fax: +65 6317 7799Cisco Systems has more than 200 offices in the following countries and regions. Addresses, phone numbers, and fax numbers are listed onthe Cisco Website at www.cisco.com/go/offices.Argentina · Australia · Austria · Belgium · Brazil · Bulgaria · Canada · Chile · China PRC · Colombia · Costa Rica · Croatia · Cyprus Czech Republic · Denmark · Dubai, UAE · Finland · France · Germany · Greece · Hong Kong SAR · Hungary · India · Indonesia · Ireland · Israel Italy · Japan · Korea · Luxembourg · Malaysia · Mexico · The Netherlands · New Zealand · Norway · Peru · Philippines · Poland · Portugal Puerto Rico · Romania · Russia · Saudi Arabia · Scotland · Singapore · Slovakia · Slovenia · South Africa · Spain · Sweden · Switzerland · Taiwan Thailand · Turkey · Ukraine · United Kingdom · United States · Venezuela · Vietnam · ZimbabweCopyright  2005 Cisco Systems, Inc. All rights reserved. CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StrataView Plus, TeleRouter, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0502R)	205482.CE_ETMG_CC_11.05Printed in the USA