You can manage and monitor all rack-mount servers that have been integrated with a Cisco UCS instance through Cisco UCS Manager. All management and monitoring features are supported for rack-mount servers except power capping. Some rack-mount server management tasks, such as changes to the power state, can be performed from both the server and service profile. The remaining management tasks can only be performed on the server.
Cisco UCS Manager provides information, errors, and faults for each rack-mount server that it has discovered.
Tip
For information about how to integrate a supported Cisco UCS rack-mount server with Cisco UCS Manager, see the hardware installation guide for that server.
Booting Rack-Mount Servers
Booting a Rack-Mount Server
If the
Boot Server link is dimmed in the
Actions area, you must shut down the server
first.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to boot.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Boot Server.
Step 6
If
Cisco UCS Manager GUI
displays a confirmation dialog box, click
Yes.
After the server has booted, the
Overall Status field on the
General tab displays an OK status.
Booting a Server from the Service Profile
Procedure
Step 1
In the
Navigation pane, click the
Servers tab.
Step 2
On the
Servers tab, expand
Servers > Service Profiles.
Step 3
Expand the node for the organization where you want to create the service profile.
If the system does not include multi-tenancy, expand the
root node.
Step 4
Choose the service profile that requires the associated server to be booted.
Step 5
In the
Work pane, click the
General tab.
Step 6
In the Actions area, click Boot Server.
Step 7
If
Cisco UCS Manager GUI
displays a confirmation dialog box, click
Yes.
Step 8
Click OK in the Boot Server dialog box.
After the server has booted, the Overall Status field on the General tab displays an ok status or an up status.
Determining the Boot Order of a Rack-Mount Server
Tip
You can also view the boot order tabs from the General tab of the service profile associated with a server.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Click the server for which you want to determine the boot order.
Step 4
In the
Work pane, click the
General tab.
Step 5
If the Boot Order Details area
is not expanded, click the Expand icon to the right of the heading.
Step 6
To view the boot order assigned to the server, click the Configured Boot Order tab.
Step 7
To view what will boot from the various devices in the physical server configuration, click the Actual Boot Order tab.
Note
The Actual Boot Order tab always shows "Internal EFI Shell" at the bottom of the boot order list.
Shutting Down Rack-Mount Servers
Shutting Down a Rack-Mount Server
When you use this procedure to shut down
a server with an installed operating system,
Cisco UCS Manager
triggers the OS into a graceful shutdown sequence.
If the
Shutdown server link is dimmed in the
Actions area, the server is not running.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to shut down.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Shutdown Server.
Step 6
If
Cisco UCS Manager GUI
displays a confirmation dialog box, click
Yes.
After the server has been successfully shut down, the
Overall Status field on the
General tab displays a power-off status.
Shutting Down a Server from the
Service Profile
When you use this procedure to shut down
a server with an installed operating system,
Cisco UCS Manager
triggers the OS into a graceful shutdown sequence.
If the
Shutdown Server link is dimmed in the
Actions area, the server is not running.
Procedure
Step 1
In the
Navigation pane, click the
Servers tab.
Step 2
On the
Servers tab, expand
Servers > Service Profiles.
Step 3
Expand the node for the organization where you want to create the service profile.
If the system does not include multi-tenancy, expand the
root node.
Step 4
Choose the
service profile
that requires the associated server to be shut down.
Step 5
In the
Work pane, click the
General tab.
Step 6
In the
Actions area, click
Shutdown Server.
Step 7
If
Cisco UCS Manager GUI
displays a confirmation dialog box, click
Yes.
After the server has been successfully shut down, the
Overall Status field on the
General tab displays a down status or a
power-off status.
Resetting a Rack-Mount Server
When you reset a server,
Cisco UCS Manager sends a pulse on the reset line. You can choose to gracefully
shut down the operating system. If the operating system does not support a
graceful shut down, the server is power cycled. The option to have
Cisco UCS Manager complete all management operations before it resets the server
does not guarantee that these operations will be completed before the server is
reset.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to reset.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Reset.
Step 6
In the
Reset Server dialog box, do the following:
Click the
Power Cycle option.
Optional: Check the check box if you want
Cisco UCS Manager
to complete all management operations that are pending on this server.
Click
OK.
The reset may take several minutes to complete. After the server has
been reset, the
Overall Status field on the
General tab displays an ok status.
Reacknowledging a Rack-Mount Server
Perform the following procedure if
you need to have
Cisco UCS Manager rediscover the server and all endpoints in the server. For
example, you can use this procedure if a server is stuck in an unexpected
state, such as the discovery state.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to acknowledge.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Server Maintenance.
Step 6
In the
Maintenance dialog box, do the following:
Click
Re-acknowledge.
Click
OK.
Cisco UCS Manager disconnects the server and then builds the connections
between the server and the fabric interconnect or fabric interconnects in the
system. The acknowledgment may take several minutes to complete. After the
server has been acknowledged, the
Overall Status field on the
General tab displays an OK status.
Decommissioning a Rack-Mount Server
This procedure decommissions a server and deletes it from the Cisco UCS configuration. The server hardware physically remains in the
Cisco UCS instance. However,
Cisco UCS Manager ignores it and does not list it with the other servers.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to decommission.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Server Maintenance.
Step 6
In the
Maintenance dialog box, do the following:
Click
Decommission.
Click
OK.
The server is removed from the
Cisco UCS configuration.
Removing a Non-Existent Rack-Mount Server from the Configuration Database
Perform the following procedure if
you physically removed the server hardware without first
decommissioning the server. You cannot perform this procedure if the server is
physically present.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server that you want to remove from the configuration
database.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Server Maintenance.
Step 6
In the
Maintenance dialog box, do the following:
Click
Remove.
Click
OK.
Cisco UCS Manager removes all data about the server from its configuration
database. The server slot is now available for you to insert new server
hardware.
Turning the Locator LED for a Rack-Mount Server On and Off
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server for which you want to turn the locator LED on or off.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
one of the following:
Turn on Locator LED
Turn off Locator LED
Resetting the CMOS for a Rack-Mount Server
On rare occasions, troubleshooting a
server may require you to reset the CMOS. This procedure is not part of the
normal maintenance of a server.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server for which you want to reset the CMOS.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Recover Server.
Step 6
In the
Recover Server dialog box, do the following:
Click
Reset CMOS.
Click
OK.
Resetting the CIMC for a Rack-Mount Server
On rare occasions, such as an issue with
the current running firmware, troubleshooting a server may require you to reset
the CIMC. This procedure is not part of the normal maintenance of a server.
After you reset the CIMC, the server boots with the running version of the
firmware for that server.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server for which you want to reset the CIMC.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Recover Server.
Step 6
In the
Recover Server dialog box, do the following:
Click
Reset CIMC (Server Controller).
Click
OK.
Recovering the Corrupt BIOS on a Rack-Mount Server
On rare occasions, an issue with a server may require you to recover the corrupted BIOS. This procedure is not part of the normal maintenance of a server.
After you recover the BIOS, the server boots with the running version of the
firmware for that server. This radio button may be dimmed if the BIOS does not require recovery or the option is not available for a particular server.
Before You Begin
Important:
Remove all attached or mapped USB storage from a server before you attempt to recover the corrupt BIOS on that server. If an external USB drive is attached or mapped from vMedia to the server, BIOS recovery fails.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server for which you want to recover the BIOS.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the
Actions area, click
Recover Server.
Step 6
In the
Recover Server dialog box, do the following:
Click
Recover Corrupt BIOS.
Click
OK.
Step 7
If
Cisco UCS Manager GUI
displays a confirmation dialog box, click
Yes.
Step 8
In the Recover Corrupt BIOS dialog box, do the following:
Complete the following fields:
Name
Description
Version To Be
Activated drop-down list
Choose the firmware version that
you want to activate from the drop-down list.
Ignore Compatibility
Check check box
By default,
Cisco UCS makes sure that the firmware version is compatible with
everything running on the server before it activates that version.
Check this check box if you
want
Cisco UCS
to activate the firmware without making sure that it is compatible first.
Note
We recommend that you use this option only when explicitly
directed to do so by a technical support representative.
Click OK.
Viewing the POST Results for a Rack-Mount Server
You can view any errors collected during the Power On Self-Test process for a server and its adapters.
Procedure
Step 1
In the
Navigation pane, click the
Equipment tab.
Step 2
On the
Equipment tab, expand
Equipment > Rack Mounts > Servers.
Step 3
Choose the server for which you want to view the POST results.
Step 4
In the
Work pane, click the
General tab.
Step 5
In the Actions area, click View POST Results.
The POST Results dialog box lists the POST results for the server and its adapters.
Step 6
(Optional)Click the link in the Affected Object column to view the properties of that adapter.