Cisco UCS
uses firmware obtained from and certified by Cisco to support the endpoints in a Cisco UCS instance. Each endpoint is a component in the instance that requires firmware to function. A Cisco UCS instance includes the following firmware endpoints that need to be upgraded when you upgrade the firmware:
Endpoints physically located on servers, such as the BIOS, storage controller (RAID controller), and Cisco Integrated Management Controller (CIMC)
Endpoints physically located on adapters, including NIC and HBA firmware, and Option ROM (where
applicable)
I/O modules
Fabric interconnects
Cisco UCS Manager
Note
Beginning with Cisco UCS, Release 1.4(1), Cisco is releasing firmware upgrades in multiple bundles, rather than one large firmware package. For more information see Firmware Image Management.
This document uses the following definitions for managing firmware:
Upgrade
Changes the firmware running on an endpoint to another image, such as a release or patch. Upgrade includes both update and activation.
Update
Copies the firmware image to the backup partition on an endpoint.
Activate
Sets the firmware in the backup partition as the active firmware version on the endpoint. Activation can require or cause the reboot of an endpoint.
For Management Extensions and Capability Catalog upgrades, update and activate occur simultaneously. You only need to update or activate those upgrades. You do not need to perform both steps.
Firmware Image Management
Cisco delivers all firmware updates to
Cisco UCS
components in bundles of images. Cisco UCS firmware updates are available to be downloaded in the following bundles:
Cisco UCS Infrastructure Software Bundle
This bundle includes the following firmware images that are required to update the following components:
Cisco UCS Manager software
Kernel and system firmware for the fabric interconnects
I/O module firmware
Cisco UCS B-Series Blade Server Software Bundle
This bundle includes the following firmware images that are required to update the firmware for the blade servers in a Cisco UCS instance. In addition to the bundles created for a release, these bundles can also be released between infrastructure bundles to enable Cisco UCS Manager to support a blade server that is not included in the most recent infrastructure bundle.
CIMC firmware
BIOS firmware
Board controller firmware
Third-party firmware images required by the new server
Cisco UCS C-Series Rack-Mount Server Software Bundle
This bundle includes firmware images that are required to update the following components on rack-mount servers that have been integrated with and are managed by Cisco UCS Manager:
CIMC
BIOS
Adapters
Storage controllers
Note
You cannot use this bundle for standalone C-series servers. The firmware management system in those servers cannot interpret the header required by Cisco UCS Manager. For information on how to upgrade standalone C-series servers, see the C-series configuration guides.
Cisco also provides release notes, which you can obtain
on the same website from which you obtained the bundles.
Every firmware image has a header, which includes the following:
Checksum
Version information
Compatibility information that the system can use to verify the compatibility of component images and any dependencies
Firmware Image Catalog
Cisco UCS Manager
provides you with two views of the catalog of firmware images and their
contents that have been downloaded to the fabric interconnect:
Packages
This view provides you with a read-only representation of the
firmware bundles that have been downloaded onto the fabric interconnect. This view is
sorted by image, not by the contents of the image. For packages, you can use
this view to see which component images are in each downloaded firmware bundle.
Images
The images view lists the component images available on the
system. You cannot use this view to see complete firmware bundles or to group the images by bundle. The information available
about each component image includes the name of the component, the image size,
the image version, and the vendor and model of the component.
You can use this view to identify the firmware updates available
for each component. You can also use this view to delete obsolete and unneeded
images. Cisco UCS Manager deletes a package after all images in the package have been
deleted.
Tip
Cisco UCS Manager
stores the images in bootflash on the fabric interconnect. In a cluster system,
space usage in bootflash on both fabric interconnects is the same, because all
images are synchronized between them. If
Cisco UCS Manager
reports that the bootflash is out of space, delete obsolete images to free up
space.
Firmware Versions
The firmware versions on an endpoint depend upon the type of endpoint.
The endpoints physically located on a fabric interconnect have different versions than those physically located on a server or I/O module.
Firmware Versions in CIMC, I/O Modules, and Adapters
Each CIMC, I/O module, and adapter has two slots for firmware in flash.
Each slot holds a version of firmware. One slot is active and the other is the
backup slot. A component boots from whichever slot is designated as active.
The following firmware version terminology is used in Cisco UCS Manager:
Running Version
The running version is the firmware that is active and
in use by the endpoint.
Startup Version
The startup version is the firmware that will be used when the
endpoint next boots up.
Cisco UCS Manager
uses the activate operation to change the startup version.
Backup Version
The backup version is the firmware in the other
slot and is not in use by the endpoint. This version can be firmware that you have
updated to the endpoint but have not yet activated, or it can be an older
firmware version that was replaced by a recently activated version.
Cisco UCS Manager
uses the update operation to replace the image in the backup slot.
If the endpoint cannot boot from the startup version, it
boots from the backup version.
Firmware Versions in the Fabric Interconnect and
Cisco UCS Manager
You can only activate the fabric interconnect firmware and
Cisco UCS Manager
on the fabric interconnect. The fabric interconnect and
Cisco UCS Manager
firmware do not have backup versions, because all the images are stored on the
fabric interconnect. As a result, the number of bootable fabric interconnect
images is not limited to two, like the server CIMC and adapters. Instead, the
number of bootable fabric interconnect images is limited by the available space
in the memory of the fabric interconnect and the number of images stored there.
The fabric interconnect
and
Cisco UCS Manager
firmware have running and startup versions of the kernel and system firmware. The kernel and system firmware must run the same versions of firmware.
Firmware Upgrades
Cisco UCS firmware is upgraded through a combination of the following methods:
Direct upgrade at the endpoints. For a cluster configuration with two fabric interconnects, a direct upgrade can be minimally disruptive to data traffic. However, it requires that the Cisco UCS instance does not include firmware policies for those endpoints that you upgrade directly. You cannot avoid disruption to traffic in a Cisco UCS instance with only one fabric interconnection.
Upgrades to server endpoints through
service profiles
that include a host firmware package, a management firmware package, or both. This method is disruptive to data traffic and should be performed during a maintenance window.
Note
Direct upgrade is not available for all endpoints, including the
server BIOS, storage controller, HBA firmware, and HBA option ROM.
You must upgrade those endpoints through the host firmware package included in the
service profile associated with the server.
Before you upgrade the firmware for any endpoint in a Cisco UCS instance, consider the following guidelines and cautions:
Determine Appropriate Type of Firmware Upgrade for Each Endpoint
Some endpoints, such as adapters and the server CIMC, can be upgraded through either a direct firmware upgrade or a firmware package included in a service profile. The configuration of a Cisco UCS instance determines how you upgrade these endpoints. If the service profiles associated with the servers include a host firmware package, upgrade the adapters for those servers through the firmware package. In the same way, if the service profiles associated with the servers include a management firmware package, upgrade the CIMC for those servers through the firmware package.
Upgrades of a CIMC through a management firmware package or an adapter through a firmware package in the service profile associated with the server take precedence over direct firmware upgrades. You cannot directly upgrade an endpoint if the service profile associated with the server includes a firmware package. To perform a direct upgrade, you must remove the firmware package from the service profile.
No Server or Chassis Maintenance
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Number of Fabric Interconnects
For a cluster configuration with two fabric interconnects, you can take advantage of the failover between the fabric interconnects and perform a direct firmware upgrade of the endpoints without disrupting data traffic. However, you cannot avoid disrupting data traffic for those endpoints which must be upgraded through a host or management firmware package.
For a standalone configuration with a single fabric interconnect, you can minimize the disruption to data traffic when you perform a direct firmware upgrade of the endpoints. However, you must reboot the fabric interconnect to complete the upgrade and, therefore, cannot avoid disrupting traffic.
Do Not Activate All Endpoints Simultaneously in Cisco UCS Manager GUI
If you use Cisco UCS Manager GUI to update the firmware, do not select ALL from the Filter drop-down list in the Activate Firmware dialog box to activate all endpoints simultaneously. Many firmware releases and patches have dependencies that require the endpoints to be activated in a specific order for the firmware update to succeed. This order can change depending upon the contents of the release or patch. Activating all endpoints does not guarantee that the updates occur in the required order and can disrupt communications between the endpoints and the fabric interconnects and Cisco UCS Manager. For information about the dependencies in a specific release or patch, see the release notes provided with that release or patch.
Impact of Activation for Adapters and I/O Modules
During a direct upgrade, you should configure Set Startup Version Only for an adapter. With this setting, the activated firmware moves into the pending-next-boot state, and the server is not immediately rebooted. The activated firmware does not become the running version of firmware on the adapter until the server is rebooted. You cannot configure Set Startup Version Only for an adapter in the host firmware package.
If a server is not associated with a service profile, the activated firmware moves into the pending-next-boot state. Cisco UCS Manager does not reboot the endpoints or activate the firmware until the server is associated with a service profile. If necessary, you can manually reboot an unassociated server to activate the firmware.
When you configure Set Startup Version Only for an I/O module, the I/O module is rebooted when the fabric interconnect in its data path is rebooted. If you do not configure Set Startup Version Only for an I/O module, the I/O module reboots and disrupts traffic. In addition, if Cisco UCS Manager detects a protocol and firmware version mismatch between the fabric interconnect and the I/O module, Cisco UCS Manager automatically updates the I/O module with the firmware version that matches the firmware in the fabric interconnect and then activates the firmware and reboots the I/O module again.
Avoid Replacing RAID-Configured Hard Disks Prior to Upgrade
Under the following circumstances, Cisco UCS Manager may scrub all data on a hard disk as part of the RAID synchronization process during an upgrade of the server firmware:
The hard disks in the server are configured for RAID.
One or more of the RAID-configured hard disks in the server are removed.
The hard disk or disks are replaced with hard disks that are configured with a pre-existing RAID and the local disk configuration policy included in the service profile on the server is not used to configure those hard disks.
The server firmware is upgraded, causing the server to reboot and Cisco UCS Manager to begin the RAID synchronization process.
If the original hard disks contained vital data that needs
to preserved, avoid inserting new hard disks that are already configured for RAID.
Impact of Upgrade to Release 1.3(1i) or Higher
An upgrade from an earlier Cisco UCS firmware release to release 1.3(1i) or higher has the following impact on the Protect Configuration property of the local disk configuration policy the first time servers are associated with service profiles after the upgrade:
Unassociated Servers
After you upgrade the Cisco UCS instance, the initial server association proceeds without configuration errors whether or not the local disk configuration policy matches the server hardware. Even if you enable the Protect Configuration property, Cisco UCS does not protect the user data on the server if there are configuration mismatches between the local disk configuration policy on the previous service profile and the policy in the new service profile.
Note
If you enable the Protect Configuration property and the local disk configuration policy encounters mismatches between the previous service profile and the new service profile, all subsequent service profile associations with the server are blocked.
Associated Servers
Any servers that are already associated with service profiles do not reboot after the upgrade. Cisco UCS Manager does not report any configuration errors if there is a mismatch between the local disk configuration policy and the server hardware.
When a service profile is disassociated from a server and a new service profile associated, the setting for the Protect Configuration property in the new service profile takes precedence and overwrites the setting in the previous service profile.
Disable Call Home before Upgrading to Avoid Unecessary Alerts (Optional)
When you upgrade a Cisco UCS instance, Cisco UCS Manager restarts the components to complete the upgrade process. This restart causes events that are identical to service disruptions and component failures that trigger Call Home alerts to be sent. If you do not disable Call Home before you begin the upgrade, you can ignore the alerts generated by the upgrade-related component restarts.
Always Upgrade Cisco UCS Gen-2 Adapters through a Host Firmware Package
You cannot upgrade Cisco UCS Gen-2 adapters directly at the endpoints. You must upgrade the firmware on those adapters through a host firmware package.
The firmware on the Cisco UCS 82598KR-CI 10-Gigabit
Ethernet Adapter (N20-AI0002), Intel-based adapter card, is burned into the hardware at manufacture. You cannot upgrade the firmware on this adapter.
Required Order of Components for Firmware Activation
If you upgrade firmware by individual components in a
Cisco UCS
instance, activate the updates in the required order for
quicker activation and to avoid potential issues with conflicting firmware versions.
Required Order when Upgrading from Cisco UCS, Release 1.3(1) and Later
(Optional) Call Home—If the Cisco UCS instance includes Call Home or Smart Call Home, disable Call Home if you do not want to receive unnecessary alerts when Cisco UCS Manager restarts components to complete the firmware activation.
Adapter—If you plan to upgrade the adapters directly, perform this step first. However, if you prefer or if the adapters require it, you can omit this step and upgrade the adapters as part of the last step, in a host firmware package.
CIMC—If you upgrade the adapters in the host firmware package, perform this step first.
Cisco UCS Manager.
I/O module—Activate with Set Startup Version only.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the subordinate fabric interconnect first.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the primary fabric interconnect second
Host firmware package—Must be the last step in the upgrade process. We recommend that you upgrade the board controller firmware during this step to avoid an additional reboot of the server. You must upgrade the following firmware in a host firmware package:
BIOS
Storage controller
Gen 2 adapters
(Optional) Call Home—If you disabled Call Home before the upgrading the firmware, enable Call Home.
Required Order when Upgrading from Cisco UCS, Release 1.0(2) and Later
(Optional) Call Home—If the Cisco UCS instance includes Call Home or Smart Call Home, disable Call Home if you do not want to receive unnecessary alerts when Cisco UCS Manager restarts components to complete the firmware activation.
Adapter—If you plan to upgrade the adapters directly, perform this step first. However, if you prefer or if the adapters require it, you can omit this step and upgrade the adapters as part of the last step, in a host firmware package.
BMC—If you upgrade the adapters in the host firmware package, perform this step first.
Cisco UCS Manager.
I/O module—Activate with Set Startup Version only.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the subordinate fabric interconnect first.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the primary fabric interconnect second
Host firmware package—Must be the last step in the upgrade process. We recommend that you upgrade the board controller firmware during this step to avoid an additional reboot of the server. You must upgrade the following firmware in a host firmware package:
BIOS
Storage controller
Gen 2 adapters
(Optional) Call Home—If you disabled Call Home before the upgrading the firmware, enable Call Home.
Required Order when Upgrading from Cisco UCS, Release 1.0(1)
(Optional) Call Home—If the Cisco UCS instance includes Call Home or Smart Call Home, disable Call Home if you do not want to receive unnecessary alerts when Cisco UCS Manager restarts components to complete the firmware activation.
Adapter
(interface card)—If you plan to upgrade the adapters directly, perform this step first. However, if you prefer, you can omit this step and upgrade the adapters as part of the last step, in a host firmware package.
BMC—If you upgrade the adapters in the host firmware package, perform this step first.
Cisco UCS Manager.
I/O module—Activate with Set Startup Version only.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the subordinate fabric interconnect first.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the primary fabric interconnect second
Host firmware package—Must be the last step in the upgrade process. We recommend that you upgrade the board controller firmware during this step to avoid an additional reboot of the server. You must upgrade the following firmware in a host firmware package:
BIOS
Storage controller
Gen 2 adapters
(Optional) Call Home—If you disabled Call Home before the upgrading the firmware, enable Call Home.
Required Order for Adding Support for Previously Unsupported Servers
From Cisco UCS, Release 1.4(1) and later, the method for adding support for previously unsupported type of servers, such as a new blade server or a rack-mount server, to an existing Cisco UCS instance requires the following additional steps after you upgrade your existing firmware to the new release.
Adding Support for a Previously Unsupported Cisco UCS Blade Server
After you upgrade the firmware for the existing components, you can add support for a previously unsupported server that was released between infrastructure bundle releases. When you add the first server of a previously unsupported type of blade server, you must perform the steps to enable Cisco UCS Manager to support that type of server in the following order:
Insert the blade server into the chassis as described in the server installation guide. Cisco UCS Manager cannot discover the server as it is unsupported, and the finite state machine (FSM) for the discovery fails with an unsupported server error.
Obtain the B-Series server bundle for the new blade server from Cisco.com and download it to the fabric interconnect.
Activate the Capability Catalog image from the server bundle.
Activate the Management Extension from the server bundle.
Wait for Cisco UCS Manager to retry discovery of the new server. If server discovery does not begin within a few minutes, acknowledge the server.
Note
You only need to perform these steps for the first server of a previously unsupported type of blade server. Cisco UCS Manager discovers all subsequent servers of that type automatically.
Integrating a Cisco UCS Rack-Mount Server
After you upgrade the firmware for the existing components, you can integrate a Cisco UCS rack-mount server. When you integrate a rack-mount server, you must perform the steps in the following order:
If you have not already done so, configure the rack server discovery policy in Cisco UCS Manager.
Follow the instructions in the server installation guide for installing and integrating a rack-mount server in a system managed by Cisco UCS Manager.
Wait for Cisco UCS Manager to discover the new server. If server discovery does not begin within a few minutes, acknowledge the server.
Direct Firmware Upgrade at Endpoints
If you follow the correct procedure and apply the upgrades in the correct order, a direct firmware upgrade and the activation of the new firmware version on the endpoints is minimally disruptive to traffic in a Cisco UCS instance.
You can directly upgrade the firmware on the following endpoints:
Adapters
CIMCs
I/O modules
Board controllers
Cisco UCS Manager
Fabric interconnects
The adapter and board controller firmware can also be upgraded through the host firmware package in the service profile. If you use a host firmware package to upgrade this firmware, you can reduce the number of times a server needs to be rebooted during the firmware upgrade process.
Note
Upgrades of a CIMC through a management firmware package or an adapter through a firmware package in the service profile associated with the server take precedence over direct firmware upgrades. You cannot directly upgrade an endpoint if the service profile associated with the server includes a firmware package. To perform a direct upgrade, you must remove the firmware package from the service profile.
Cisco UCS Manager
separates the direct upgrade process into two stages to ensure that you can push the
firmware to an endpoint while the system is running without affecting uptime on
the server or other endpoints.
Update
During this stage, the system copies the selected firmware version from the primary fabric interconnect to
the backup partition in the endpoint and verifies that the firmware image is not corrupt. The update process always overwrites the firmware in the backup
slot.
The update stage applies only to the following endpoints:
Adapters
CIMCs
I/O modules
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Activate
During this stage, the system sets the specified image version
(normally the backup version) as the startup version and, if you do not specify Set Startup Version Only, immediately reboots the endpoint. When the
endpoint is rebooted, the backup partition becomes the active partition, and the active
partition becomes the backup partition. The firmware in the new active partition becomes the
startup version and the running version.
The following endpoints only require activation because the specified firmware image already exists on the endpoint:
Cisco UCS Manager
Fabric interconnects
Board controllers on those servers that support them
When the firmware is activated, the endpoint is rebooted and the new firmware becomes the active kernel version and system version. If the endpoint cannot boot from the startup firmware, it defaults to
the backup version and raises a fault.
Caution
When you configure Set Startup Version Only for an I/O module, the I/O module is rebooted when the fabric interconnect in its data path is rebooted. If you do not configure Set Startup Version Only for an I/O module, the I/O module reboots and disrupts traffic. In addition, if Cisco UCS Manager detects a protocol and firmware version mismatch between the fabric interconnect and the I/O module, Cisco UCS Manager automatically updates the I/O module with the firmware version that matches the firmware in the fabric interconnect and then activates the firmware and reboots the I/O module again.
Outage Impacts of Direct Firmware Upgrades
When you perform a direct firmware upgrade on an endpoint, you can disrupt traffic or cause an outage in one or more of the endpoints in the Cisco UCS instance.
Outage Impact of a Fabric Interconnect Firmware Upgrade
When you upgrade the firmware for a fabric interconnect, you cause the following outage impacts and disruptions:
The fabric interconnect reboots.
The corresponding I/O modules reboot.
Outage Impact of a Cisco UCS Manager Firmware Upgrade
A firmware upgrade to Cisco UCS Manager causes the following disruptions:
Cisco UCS Manager GUI—All users logged in to Cisco UCS Manager GUI are logged out and their sessions ended.
Any unsaved work in progress is lost.
Cisco UCS Manager CLI—All users logged in through telnet are logged out and their sessions ended. Console sessions are not ended.
Outage Impact of an I/O Module Firmware Upgrade
When you upgrade the firmware for an I/O module, you cause the following outage impacts and disruptions:
For a standalone configuration with a single fabric interconnect, data traffic is disrupted when the I/O module reboots. For a cluster configuration with two fabric interconnects, data traffic fails over to the other I/O module and the fabric interconnect in its data path.
If you activate the new firmware as the startup version only, the I/O module reboots when the corresponding fabric interconnect is rebooted.
If you activate the new firmware as the running and startup version, the I/O module reboots immediately.
An I/O module can take up to ten minutes to become available after a firmware upgrade.
Outage Impact of a CIMC Firmware Upgrade
When you upgrade the firmware for a CIMC in a server, you impact only the CIMC and internal processes. You do not interrupt server traffic. This firmware upgrade causes the following outage impacts and disruptions to the CIMC:
Any activities being performed on the server through the KVM console and vMedia are interrupted.
Any monitoring or IPMI polling is interrupted.
Outage Impact of an Adapter Firmware Upgrade
If you activate the firmware for an adapter and do not configure the Set Startup Version Only option, you cause the following outage impacts and disruptions:
The server reboots.
Server traffic is disrupted.
Firmware Upgrades through
Service Profiles
You can use
service profiles
to upgrade the server and adapter firmware, including the BIOS on the server, by
defining the following policies and including them in the
service profile
associated with a server:
Host Firmware Package policy
Management Firmware Package policy
Note
You cannot upgrade the firmware on an I/O module, fabric interconnect,
or
Cisco UCS Manager
through
service profiles.
You must upgrade the firmware on those endpoints directly.
This policy enables you to specify a set of firmware versions
that make up the host firmware package (also known as the host firmware pack). The host firmware includes the following firmware for
server and adapter endpoints:
Adapter
BIOS
Board Controller
FC Adapters
HBA Option ROM
Storage Controller
Tip
You can include more than one type of firmware in the same host firmware package. For example, a host firmware package can include both BIOS firmware and storage controller firmware or adapter firmware for two different models of adapters. However, you can only have one firmware version with the same type, vendor, and model number. The system recognizes which firmware version is required for an endpoint and ignores all other firmware versions.
The firmware package is pushed to all servers associated with
service profiles
that include this policy.
This policy ensures that the host firmware is identical on all servers
associated with
service profiles
which use the same policy. Therefore, if you move the
service profile
from one server to another, the firmware versions are maintained. Also, if you
change the firmware version for an endpoint in the firmware package, new versions
are applied to all the affected service profiles immediately, which could cause
server reboots.
You must include this policy in a
service profile,
and that
service profile
must be associated with a server for it to take effect.
Prerequisites
This policy is not dependent upon any other policies. However, you
must ensure that the appropriate firmware has been downloaded to the fabric
interconnect. If the firmware image is not available when Cisco UCS Manager is associating a server with a service profile, Cisco UCS Manager ignores the firmware upgrade and completes
the association.
Management Firmware Package
This policy enables you to specify a set of firmware versions
that make up the management firmware package (also known as a management firmware pack). The management firmware package includes the
Cisco Integrated Management Controller (CIMC) on the server.
You do not need to use this package if you upgrade the CIMC directly.
The firmware package is pushed to all servers associated with
service profiles
that include this policy.
This policy ensures that the CIMC firmware is identical on all servers
associated with service profiles
which use the same policy. Therefore, if you move the
service profile
from one server to another, the firmware versions are maintained.
You must include this policy in a
service profile,
and that service profile
must be associated with a server for it to take effect.
This policy is not dependent upon any other policies. However, you
must ensure that the appropriate firmware has been downloaded to the fabric
interconnect.
Stages of a Firmware Upgrade through
Service Profiles
You can use the host and management firmware package policies in
service profiles
to upgrade server and adapter firmware.
Caution
If you modify a host firmware package by adding an endpoint or changing firmware versions for an existing endpoint, Cisco UCS Manager upgrades the endpoints and reboots all servers associated with that firmware package as soon as the changes are saved, disrupting data traffic to and from the servers.
New Service Profile
For a new service profile, this upgrade takes place over the following stages:
Firmware Package Policy Creation
During this stage, you create the host and/or management firmware
packages and include them in the appropriate firmware policies.
Service Profile Association
During this stage, you include the firmware packages in a
service profile,
and then associate the
service profile
with a server. The system pushes the selected firmware versions to the
endpoints. For a host firmware package, the server is rebooted to ensure that the endpoints are running the versions
specified in the firmware package.
Existing Service Profile
If the service profile is already associated with a server, Cisco UCS Manager upgrades the firmware as soon as you save the changes to the host firmware packages. For a host firmware package, Cisco UCS Manager reboots the server as soon as the change is saved.
Firmware Downgrades
You downgrade firmware in a Cisco UCS instance in the same way that you upgrade firmware. The package or version that you select when you update the firmware determines whether you are performing an upgrade or a downgrade.
Completing the Prerequisites for Upgrading the Firmware
Prerequisites for Upgrading and Downgrading Firmware
All endpoints in a Cisco UCS instance must be fully functional and all processes must be complete before you begin a firmware upgrade or downgrade on those endpoints. You cannot upgrade or dtowngrade an endpoint that is not in a functional state. For example, the firmware on a server that has not been discovered cannot be upgraded or downgraded. An incomplete process, such as an FSM that has failed after the maximum number of retries, can cause the upgrade or downgrade on an endpoint to fail. If an FSM is in progress, Cisco UCS Manager queues up the update and activation and runs them when the FSM has completed successfully.
Before you upgrade or downgrade firmware in a Cisco UCS instance, complete the following prerequisites:
Back up the configuration into an All Configuration backup file.
For a cluster configuration, verify that the high availability status of the fabric interconnects shows that both are up and running.
For a standalone configuration, verify that the Overall Status of the fabric interconnect is Operable.
Verify that all servers, I/O modules, and adapters are fully functional. An inoperable server cannot be upgraded.
Verify that all servers have been discovered. They do not need to be powered on or associated with a service profile.
Creating an All Configuration Backup File
This procedure assumes that you do not have an existing backup operation for an All Configuration backup file.
Before You Begin
Obtain the backup server IP address and authentication credentials.
Creates an enabled All Configuration backup operation that runs as soon as you enter the commit-buffer command. The all-configuration option backs up the server, fabric, and system related configuration. Specify the URL for the backup file using one of the following syntax:
ftp://username@hostname/path
scp://username@hostname/path
sftp://username@hostname/path
tftp://hostname:port-num/path
Step 3
UCS-A /system # commit-buffer
Commits the transaction.
The following example uses SCP to create an All Configuration backup file on the host named host35 and commits the transaction:
Verifying the Operability of a Fabric Interconnect
If your Cisco UCS instance is running in a high availability cluster configuration, you must verify the operability of both fabric interconnects.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope fabric-interconnect {a | b}
Enters fabric interconnect mode for the specified fabric interconnect.
Step 2
UCS-A /fabric-interconnect #show
Displays information about the fabric interconnect.
Verify that the operability of the fabric interconnects is in the Operable state. If the operability is not in the Operable state, run a show tech-support command and contact Cisco Technical Support. Do not proceed with the firmware upgrade. For more information about the show tech-support command, see the Cisco UCS Troubleshooting Guide.
The following example displays that the operability for both fabric interconnects is in the Operable state:
UCS-A# scope fabric-interconnect a
UCS-A /fabric-interconnect # show
Fabric Interconnect:
ID OOB IP Addr OOB Gateway OOB Netmask Operability
-- --------------- --------------- --------------- -----------
A 192.168.100.10 192.168.100.20 255.255.255.0 Operable
UCS-A /fabric-interconnect # exit
UCS-A# scope fabric-interconnect b
UCS-A /fabric-interconnect # show
Fabric Interconnect:
ID OOB IP Addr OOB Gateway OOB Netmask Operability
-- --------------- --------------- --------------- -----------
B 192.168.100.11 192.168.100.20 255.255.255.0 Operable
Verifying the High Availability Status and Roles of a Cluster Configuration
The high availability status is the same for both fabric interconnects in a cluster configuration.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
show cluster state
Displays the operational state and leadership role for both fabric
interconnects in a high availability cluster.
Verify that both fabric interconnects (A and B) are in the Up state and HA is in the Ready state. If the fabric interconnects are not in the Up state or HA is not in the Ready state, run a show tech-support command and contact Cisco Technical Support. Do not proceed with the firmware upgrade. For more information about the show tech-support command, see the Cisco UCS Troubleshooting Guide.
Also note which fabric interconnect has the primary role and which has the subordinate role; you will need to know this information to upgrade the firmware on the fabric interconnects.
The following example displays that both fabric interconnects are in the Up state, HA is in the Ready state, fabric interconnect A has the primary role,
and fabric interconnect B has the subordinate role:
UCS-A# show cluster state
Cluster Id: 0x4432f72a371511de-0xb97c000de1b1ada4
A: UP, PRIMARY
B: UP, SUBORDINATE
HA READY
Verifying the Status of an I/O Module
If your Cisco UCS is running in a high availability cluster configuration, you must verify the status for both I/O modules in all chassis.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope chassischassis-id
Enters chassis mode for the specified chassis.
Step 2
UCS-A /chassis #
scope iomiom-id
Enters chassis I/O module mode for the selected I/O module.
Step 3
UCS-A #
show
Shows the status of the specified I/O module on the specified chassis.
Verify that the overall status of the I/O module is in the Operable state. If the overall status is not in the Operable state, run a show tech-support command and contact Cisco Technical Support. Do not proceed with the firmware upgrade. For more information about the show tech-support command, see the Cisco UCS Troubleshooting Guide.
The following example displays that the overall status for both I/O modules on chassis 1 is in the Operable state:
UCS-A# scope chassis 1
UCS-A /chassis # scope iom 1
UCS-A /chassis/iom # show
IOM:
ID Side Fabric ID Overall Status
---------- ----- --------- --------------
1 Left A Operable
UCS-A /chassis/iom # exit
UCS-A /chassis # scope iom 2
UCS-A /chassis/iom # show
IOM:
ID Side Fabric ID Overall Status
---------- ----- --------- --------------
2 Right B Operable
Verifying the Status of a Server
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope serverchassis-id/server-id
Enters chassis server mode for the specified server in the specified chassis.
Step 2
UCS-A /chassis/server #
show status detail
Shows the status detail of the server.
Verify that the overall status of the server is Ok, Unavailable, or any value that does not indicate a failure. If the overall status is in a state that indicates a failure, such as Discovery Failed, the endpoints on that server cannot be upgraded.
The following example displays that the overall status for server 7 on chassis 1 is in the Ok state:
UCS-A# scope server 1/7
UCS-A /chassis/server # show status detail
Server 1/7:
Slot Status: Equipped
Conn Path: A,B
Conn Status: A,B
Managing Instance: B
Availability: Unavailable
Admin State: In Service
Overall Status: Ok
Oper Qualifier: N/A
Discovery: Complete
Current Task:
Verifying the Status of Adapters on Servers in a Chassis
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope serverchassis-id/server-id
Enters chassis server mode for the specified server in the specified chassis
Step 2
UCS-A /chassis/server #
show adapter status
Displays the status of the adapter.
Verify that the overall status of the adapter is in the Operable state. If the overall status of the adapter is in any state other than Operable, you cannot upgrade it. However, you can proceed with the upgrade for the other adapters in the Cisco UCS instance.
The following example displays that the overall status for the adapter in server 7 on chassis 1 is in the Operable state:
UCS-A# scope server 1/7
UCS-A /chassis/server # show adapter status
Server 1/1:
Overall Status
--------------
Operable
Downloading and Managing Firmware Packages
Obtaining Software Bundles from Cisco
Before You Begin
Determine which of the following software bundles you need to update the Cisco UCS instance:
Cisco UCS Infrastructure Software Bundle—Required for all Cisco UCS instances.
Cisco UCS B-Series Blade Server Software Bundle—Required for all Cisco UCS instances that include blade servers.
Cisco UCS C-Series Rack-Mount Server Software Bundle—Only required for Cisco UCS instances that include integrated rack-mount servers. This bundle contains firmware to enable Cisco UCS Manager to manage those servers and is not applicable to standalone C-Series rack-mount servers.
Cisco UCS B-Series Blade Server Software Bundle—Click Cisco UCS Manager Server Software > UCS B-Series Blade Server Software > Unified Computing System (UCS) Server Software.
Cisco UCS C-Series Rack-Mount Server Software Bundle—Navigate to Cisco UCS Manager Server Software > UCS C-Series RackMount Server Software > Unified Computing System (UCS) Server Software.
Step 6
On any page where you download a software bundle, click the Release Notes link to download the latest version of the Release Notes.
Step 7
For each software bundle that you want to download, do the following:
Click the link for the release you want to download.
Click one of the following buttons and follow the instructions provided:
Download Now—Allows you to download the software bundle immediately.
Add to Cart—Adds the software bundle to your cart to be downloaded at a later time.
Follow the prompts to complete your download of the software bundle(s).
Step 8
Read the Release Notes before upgrading Cisco UCS.
What to Do Next
Download the software bundles to the fabric interconnect.
Downloading Firmware Images to the Fabric Interconnect from a Remote Location
Note
In a cluster setup, the image file for the firmware bundle is downloaded
to both fabric interconnects, regardless of which fabric interconnect is used
to initiate the download.
Cisco UCS Manager
maintains all firmware packages and images in both fabric interconnects in sync. If one fabric
interconnect is down, the download still finishes
successfully. The images are synced to the other fabric interconnect when it
comes back online.
Before You Begin
Obtain the required firmware bundles from Cisco.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware #
download imageURL
Downloads the firmware bundle for
Cisco UCS.
Using the download path provided by Cisco, specify the URL with one of the
following syntax:
ftp://server-ip-addr/path
scp://username@server-ip-addr/path
sftp://username@server-ip-addr/path
tftp://server-ip-addr:port-num/path
Note
TFTP has a file size limitation of 32 MB. Because firmware bundles can be much larger than that, we recommend that you do not select TFTP for firmware downloads.
If you use a hostname rather than an IP address, configure a DNS server in Cisco UCS Manager.
Step 3
Enter the password for the remote server.
The password for the remote server username. This field does not apply if the protocol is tftp.
Step 4
UCS-A /firmware #
show download-task
Displays the status for your download task. When your image is
completely downloaded, the task state changes from Downloading to Downloaded.
The CLI does not automatically refresh, so you may have to enter the
show download-task command multiple times until
the task state displays Downloaded.
Step 5
Repeat this task until all of the firmware bundles have been downloaded to the fabric interconnect.
The following example uses SCP to download the
ucs-k9-bundle.1.0.0.988.gbin firmware package.
After the image file for the firmware bundles have downloaded completely, update the firmware on the endpoints.
Displaying the Firmware Package Download Status
After a firmware download operation has been started, you can check the download status to see if the package is still downloading or if it has completely downloaded.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware # show download-task
Displays the status for your download task. When your image is completely downloaded, the task state changes from Downloading to Downloaded. The CLI does not automatically refresh, so you may have to enter the show download-task command multiple times until the task state displays Downloaded.
The following example displays the download status for the ucs-k9-bundle.1.0.0.988.gbin firmware package. The show download-task command is entered multiple times until the download state indicates that the firmware package has been downloaded:
UCS-A# scope firmware
UCS-A /firmware # show download-task
Download task:
File Name Protocol Server Userid State
--------- -------- --------------- --------------- -----
ucs-k9-bundle.1.0.0.988.gbin
Scp 10.193.32.11 user1 Downloading
UCS-A /firmware # show download-task
Download task:
File Name Protocol Server Userid State
--------- -------- --------------- --------------- -----
ucs-k9-bundle.1.0.0.988.gbin
Scp 10.193.32.11 user1 Downloading
UCS-A /firmware # show download-task
Download task:
File Name Protocol Server Userid State
--------- -------- --------------- --------------- -----
ucs-k9-bundle.1.0.0.988.gbin
Scp 10.193.32.11 user1 Downloaded
Canceling an Image Download
You can cancel the download task for an image only while it is in progress. After
the image has downloaded, deleting the download task does not delete the image
that was downloaded.
You cannot cancel the FSM related to the image download task.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware # delete download-tasktask-name
Deletes the specified download task.
Step 3
UCS-A /firmware # commit-buffer
Commits the transaction to the system configuration.
Displaying All Available Software Images on the Fabric
Interconnect
This procedure is optional and displays the available software images
on the fabric interconnect for all endpoints. You can also use the
show image command in each endpoint mode to display
the available software images for that endpoint.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware #
show image
Displays all software images downloaded onto the fabric
interconnect.
Note
You must provide the software version number when directly
updating an endpoint. If you intend to directly update firmware at an endpoint,
note its version number in the right column.
The following example displays all available software images on the
fabric interconnect:
UCS-A# scope firmware
UCS-A /firmware # show image
Name Type Version
------------------------------------------------------- -------------------- -------
ucs-2100.1.0.0.988.gbin Iom 1.0(0.988)
ucs-6100-k9-kickstart.4.0.1a.N2.1.0.988.gbin Switch Kernel 4.0(1a)N2(1.0.988)
ucs-6100-k9-system.4.0.1a.N2.1.0.988.gbin Switch Software 4.0(1a)N2(1.0.988)
ucs-b200-m1-bios.S5500.86B.01.00.0030-978a.021920.gbin Server Bios S5500.86B.01.00.0030-978a.021920
ucs-b200-m1-k9-bmc.1.0.0.988.gbin Bmc 1.0(0.988)
ucs-b200-m1-sasctlr.2009.02.09.gbin Storage Controller 2009.02.09
ucs-m71kr-e-cna.1.0.0.988.gbin Adapter 1.0(0.988)
ucs-m71kr-e-hba.zf280a4.gbin Host Hba zf280a4
ucs-m71kr-e-optionrom.ZN502N5.gbin Host Hba Optionrom ZN502N5
ucs-m71kr-q-cna.1.0.0.988.gbin Adapter 1.0(0.988)
ucs-m71kr-q-optionrom.1.69.gbin Host Hba Optionrom 1.69
ucs-m81kr-vic.1.0.0.988.gbin Adapter 1.0(0.988)
ucs-manager-k9.1.0.0.988.gbin System 1.0(0.988)
Displaying All Available Packages on the Fabric Interconnect
This procedure is optional and displays the available software packages
on the fabric interconnect for all endpoints.. You can also use the
show package command in each endpoint mode to display
the available software images for that endpoint.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware #
show package
Displays all software packages downloaded onto the fabric
interconnect.
Note
You must provide the software version number when directly
updating an endpoint. If you intend to directly update firmware at an endpoint,
note its version number in the right column.
The following example displays all available software packages on the
fabric interconnect:
UCS-A# scope firmware
UCS-A /firmware # show package
Name Version
--------------------------------------------- -------
ucs-k9-bundle.1.3.0.221.bin
ucs-k9-bundle.1.4.0.292.gbin
ucs-k9-bundle.1.4.0.357.gbin
ucs-k9-bundle.1.4.0.378.gbin 1.4(0.378)
ucs-k9-bundle.1.4.0.390.gbin 1.4(0.390)
Pubs-A /firmware #
Determining the Contents of a Firmware Package
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware # show packagepackage-nameexpand
Displays the contents of the specified firmware package.
The following example displays the contents of a firmware package:
Checking the Available Space on a Fabric Interconnect
If an image download fails, check whether the bootflash on the fabric
interconnect or fabric interconnects in the
Cisco UCS
has sufficient available space.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope fabric-interconnect{a | b}
Enters fabric interconnect mode for the specified fabric.
Step 2
UCS-A /fabric-interconnect # show storage[detail | expand}
Displays the available space for the specified fabric.
Note
When you download a firmware image bundle, a fabric interconnect needs at least twice as much available space as the size of the firmware image bundle. If the bootflash does not have sufficient space,
delete the obsolete firmware, core files, and other unneeded objects from the fabric interconnect.
The following example displays the available space for a fabric interconnect:
UCS-A# scope fabric-interconnect
UCS-A /fabric-interconnect # show storage
Storage on local flash drive of fabric interconnect:
Partition Size (MBytes) Used Percentage
---------------- ---------------- ---------------
bootflash 8658 50
opt 1917 2
workspace 277 4
UCS-A /fabric-interconnect #
Deleting Firmware Packages from a Fabric Interconnect
Use this procedure if you want to delete an entire package. If you prefer, you can also delete only a single image from a package.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope firmware
Enters firmware mode.
Step 2
UCS-A /firmware # delete packagepackage-name
Deletes the specified firmware package.
Step 3
UCS-A /firmware # commit-buffer
Commits the transaction to the system configuration.
Cisco UCS Manager deletes the selected package or packages and all images contained within each package.
The following example deletes a firmware package and commits the transaction:
Updating and Activating the Firmware on an Adapter
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Updates the selected firmware version on the adapter.
Step 4
UCS-A /chassis/server/adapter #
commit-buffer
(Optional)
Commits the transaction.
Use this step only if you intend to use the show firmware command in Step 5 to verify that the firmware update completed successfully before activating the firmware in Step 6. You can skip this step and commit the update-firmware and activate-firmware commands in the same transaction; however, if the firmware update does not complete successfully, the firmware activation does not start.
Cisco UCS Manager copies the selected firmware image to the backup memory partition and verifies that image is not corrupt. The image remains as the backup version until you explicitly activate it.
Step 5
UCS-A /chassis/server/adapter #
show firmware
(Optional)
Displays the status of the firmware update.
Use this step only if you want to verify that the firmware update completed successfully. The firmware update is complete when the update status is Ready. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Updating to Ready. Continue to Step 6 when the update status is Ready.
Activates the selected firmware version on the adapter.
Use the set-startup-only keyword if you want to move the activated firmware into the pending-next-boot state and not immediately reboot the server. The activated firmware does not become the running version of firmware on the adapter until the server is rebooted. You cannot use the set-startup-only keyword for an adapter in the host firmware package.
Use the ignorecompcheck keyword if you want to ignore the compatibility check and activate the firmware regardless of any possible incompatibilities or currently executing tasks.
Step 7
UCS-A /chassis/server/adapter #
commit-buffer
Commits the transaction.
Step 8
UCS-A /chassis/server/adapter #
show firmware
(Optional)
Displays the status of the firmware activation.
Use this step only if you want to verify that the firmware activation completed successfully. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Activating to Ready.
The following example updates and activates the adapter firmware to version 1.2(1) in the same transaction, without verifying that the firmware update and firmware activation completed successfully:
UCS-A# scope adapter 1/1/1
UCS-A# /chassis/server/adapter # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-m81kr-vic.1.2.1.gbin Adapter 1.2(1) Active
UCS-A# /chassis/server/adapter # update firmware 1.2(1)
UCS-A# /chassis/server/adapter* # activate firmware 1.2(1) ignorecompcheck set-startup-only
UCS-A# /chassis/server/adapter* # commit-buffer
UCS-A# /chassis/server/adapter #
The following example updates the adapter firmware to version 1.2(1), verifies that the firmware update completed successfully before starting the firmware activation, activates the adapter firmware, and verifies that the firmware activation completed successfully:
UCS-A# scope adapter 1/1/1
UCS-A# /chassis/server/adapter # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-m81kr-vic.1.2.1.gbin Adapter 1.2(1) Active
UCS-A# /chassis/server/adapter # update firmware 1.2(1)
UCS-A# /chassis/server/adapter* # commit-buffer
UCS-A# /chassis/server/adapter # show firmware
Adapter 1:
Running-Vers: 1.1(1)
Update-Status: Updating
Activate-Status: Ready
UCS-A# /chassis/server/adapter # show firmware
Adapter 1:
Running-Vers: 1.1(1)
Update-Status: Ready
Activate-Status: Ready
UCS-A# /chassis/server/adapter # activate firmware 1.2(1) ignorecompcheck
UCS-A# /chassis/server/adapter* # commit-buffer
UCS-A# /chassis/server/adapter # show firmware
Adapter 1:
Running-Vers: 1.1(1)
Update-Status: Ready
Activate-Status: Activating
UCS-A# /chassis/server/adapter # show firmware
Adapter 1:
Running-Vers: 1.2(1)
Update-Status: Ready
Activate-Status: Ready
Updating and Activating the CIMC Firmware on a Server
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope serverchassis-id/blade-id
Enters chassis server mode for the specified server.
Step 2
UCS-A /chassis/server # scope cimc
Enters chassis server CIMC mode.
Step 3
UCS-A /chassis/server/cimc #
show image
Displays the available software images for the adapter.
Updates the selected firmware version on the CIMC in the server.
Step 5
UCS-A /chassis/cimc #
commit-buffer
(Optional)
Commits the transaction.
Use this step only if you intend to use the show firmware command in Step 6 to verify that the firmware update completed successfully before activating the firmware in Step 7. You can skip this step and commit the update-firmware and activate-firmware commands in the same transaction; however, if the firmware update does not complete successfully, the firmware activation does not start.
Cisco UCS Manager copies the selected firmware image to the backup memory partition and verifies that image is not corrupt. The image remains as the backup version until you explicitly activate it.
Step 6
UCS-A /chassis/cimc #
show firmware
(Optional)
Displays the status of the firmware update.
Use this step only if you want to verify that the firmware update completed successfully. The firmware update is complete when the update status is Ready. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Updating to Ready. Continue to Step 7 when the update status is Ready.
Activates the selected firmware version on the CIMC in the server.
Use the ignorecompcheck keyword if you want to ignore the compatibility check and activate the firmware regardless of any possible incompatibilities or currently executing tasks.
Step 8
UCS-A /chassis/server/cimc # commit-buffer
Commits the transaction.
Step 9
UCS-A /chassis/cimc #
show firmware
(Optional)
Displays the status of the firmware activation.
Use this step only if you want to verify that the firmware activation completed successfully. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Activating to Ready.
The following example updates and activates the CIMC firmware to version 1.2(1) in the same transaction, without verifying that the firmware update and firmware activation completed successfully:
UCS-A# scope server 1/1
UCS-A# /chassis/server # scope cimc
UCS-A# /chassis/server/cimc # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-b200-m1-k9-cimc.1.2.1.gbin Bmc 1.2(1) Active
UCS-A# /chassis/server/cimc # update firmware 1.2(1)
UCS-A# /chassis/server/cimc* # activate firmware 1.2(1) ignorecompcheck set-startup-only
UCS-A# /chassis/server/cimc* # commit-buffer
UCS-A# /chassis/server/cimc #
The following example updates the CIMC firmware to version 1.2(1), verifies that the firmware update completed successfully before starting the firmware activation, activates the CIMC firmware, and verifies that the firmware activation completed successfully:
UCS-A# scope server 1/1
UCS-A# /chassis/server # scope cimc
UCS-A# /chassis/server/cimc # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-b200-m1-k9-cimc.1.2.1.gbin Bmc 1.2(1) Active
UCS-A# /chassis/server/cimc # update firmware 1.2(1)
UCS-A# /chassis/server/cimc* # commit-buffer
UCS-A# /chassis/server/cimc # show firmware
Running-Vers Update-Status Activate-Status
--------------- --------------- ---------------
1.1(1) Updating Ready
UCS-A# /chassis/server/cimc # show firmware
Running-Vers Update-Status Activate-Status
--------------- --------------- ---------------
1.1(1) Ready Ready
UCS-A# /chassis/server/cimc # activate firmware 1.2(1) ignorecompcheck
UCS-A# /chassis/server/cimc* # commit-buffer
UCS-A# /chassis/server/cimc # show firmware
Running-Vers Update-Status Activate-Status
--------------- --------------- ---------------
1.1(1) Ready Activating
UCS-A# /chassis/server/cimc # show firmware
Running-Vers Update-Status Activate-Status
--------------- --------------- ---------------
1.2(1) Ready Ready
Updating and Activating the Firmware on an IOM
If your system is running in a high availability cluster configuration, you must update and activate both I/O modules.
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope chassischassis-id
Enters chassis mode for the specified chassis.
Step 2
UCS-A /chassis #
scope iomiom-id
Enters chassis I/O module mode for the selected I/O module.
Step 3
UCS-A /chassis/iom #
show image
Displays the available software images for the I/O module.
Step 4
UCS-A /chassis/iom #
update firmware
version-num
Updates the selected firmware version on the I/O module.
Step 5
UCS-A /chassis/iom #
commit-buffer
(Optional)
Commits the transaction.
Use this step only if you intend to use the show firmware command in Step 6 to verify that the firmware update completed successfully before activating the firmware in Step 7. You can skip this step and commit the update-firmware and activate-firmware commands in the same transaction; however, if the firmware update does not complete successfully, the firmware activation does not start.
Cisco UCS Manager copies the selected firmware image to the backup memory partition and verifies that image is not corrupt. The image remains as the backup version until you explicitly activate it.
Step 6
UCS-A /chassis/iom #
show firmware
(Optional)
Displays the status of the firmware update.
Use this step only if you want to verify that the firmware update completed successfully. The firmware update is complete when the update status is Ready. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Updating to Ready. Continue to Step 7 when the update status is Ready.
Activates the selected firmware version on the I/O module.
Use the set-startup-only keyword if you want to reboot the I/O module only when the fabric interconnect in its data path reboots. If you do not use the set-startup-only keyword, the I/O module reboots and disrupts traffic. In addition, if Cisco UCS Manager detects a protocol and firmware version mismatch between it and the I/O module, it updates the I/O module with the firmware version that matches its own and then activates the firmware and reboots the I/O module again.
Use the ignorecompcheck keyword if you want to ignore the compatibility check and activate the firmware regardless of any possible incompatibilities or currently executing tasks.
Step 8
UCS-A /chassis/iom #
commit-buffer
Commits the transaction.
Step 9
UCS-A /chassis/iom #
show firmware
(Optional)
Displays the status of the firmware activation.
Use this step only if you want to verify that the firmware activation completed successfully. The CLI does not automatically refresh, so you may have to enter the show firmware command multiple times until the task state changes from Activating to Ready.
The following example updates and activates the I/O module firmware to version 1.2(1) in the same transaction, without verifying that the firmware update and firmware activation completed successfully:
UCS-A# scope chassis 1
UCS-A# /chassis # scope iom 1
UCS-A# /chassis/iom # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-2100.1.2.1.gbin Iom 1.2(1) Active
UCS-A# /chassis/iom # update firmware 1.2(1)
UCS-A# /chassis/iom* # activate firmware 1.2(1) ignorecompcheck set-startup-only
UCS-A# /chassis/iom* # commit-buffer
UCS-A# /chassis/iom #
The following example updates the I/O module firmware to version 1.2(1), verifies that the firmware update completed successfully before starting the firmware activation, activates the I/O module firmware, and verifies that the firmware activation completed successfully:
UCS-A# scope chassis 1
UCS-A# /chassis # scope iom 1
UCS-A# /chassis/iom # show image
Name Type Version State
-------------------------------------------------- -------------------- ------------- -----
ucs-2100.1.2.1.gbin Iom 1.2(1) Active
UCS-A# /chassis/iom # update firmware 1.2(1)
UCS-A# /chassis/iom* # commit-buffer
UCS-A# /chassis/iom # show firmware
IOM Fabric ID Running-Vers Update-Status Activate-Status
-------- --------- --------------- --------------- ---------------
1 A 1.1(1) Updating Ready
UCS-A# /chassis/iom # show firmware
IOM Fabric ID Running-Vers Update-Status Activate-Status
-------- --------- --------------- --------------- ---------------
1 A 1.1(1) Ready Ready
UCS-A# /chassis/iom # activate firmware 1.2(1) ignorecompcheck
UCS-A# /chassis/iom* # commit-buffer
UCS-A# /chassis/iom # show firmware
IOM Fabric ID Running-Vers Update-Status Activate-Status
-------- --------- --------------- --------------- ---------------
1 A 1.1(1) Ready Activating
UCS-A# /chassis/iom # show firmware
IOM Fabric ID Running-Vers Update-Status Activate-Status
-------- --------- --------------- --------------- ---------------
1 A 1.2(1) Ready Ready
Activating the Board Controller Firmware on a Server
Only certain servers, such as the Cisco UCS B440 High Performance blade server and the Cisco UCS B230 blade server, have board controller firmware. The board controller firmware controls many of the server functions, including eUSBs, LEDs, and I/O connectors.
Note
This activation procedure causes the server to reboot. Depending upon whether or not the service profile associated with the server includes a maintenance policy, the reboot can occur immediately. To reduce the number of times a server needs to be rebooted during the upgrade process, we recommend that you upgrade the board controller firmware through the host firmware package in the service profile.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope serverchassis-id/server-id
Enters chassis server mode for the specified server.
Step 2
UCS-A /chassis/server #scope boardcontroller
Enters board controller mode for the server.
Step 3
UCS-A /chassis/server/boardcontroller #
show image
(Optional)
Displays the available software images for the board controller.
Step 4
UCS-A /chassis/server/boardcontroller #
show firmware
(Optional)
Displays the current running software image for the board controller.
Activates the selected firmware version on the board controller in the server.
Use the ignorecompcheck keyword if you want to ignore the compatibility check and activate the firmware regardless of any possible incompatibilities or currently executing tasks.
Commits the transaction to the system configuration.
Cisco UCS Manager
disconnects all active sessions, logs out all users, and activates the software.
When the upgrade is complete, you are prompted to log back in.
The following example activates the board controller firmware:
UCS-A# scope server 1/1
UCS-A# /chassis/server # scope boardcontroller
UCS-A# /chassis/server/boardcontroller # show image
Name Type Version State
-------------------------------------- ----------------- ------------------ -----
ucs-b440-m1-pld.B440100C-B4402006.bin Board Controller B440100C-B4402006 Active
UCS-A# /chassis/server/boardcontroller # show firmware
BoardController:
Running-Vers: B440100C-B4402006
Activate-Status: Ready
UCS-A# /chassis/server/boardcontroller # activate firmware B440100C-B4402006
ignorecompcheck
UCS-A# /chassis/server/boardcontroller* # commit-buffer
Activating the Cisco UCS Manager Software
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope system
Enters system mode.
Step 2
UCS-A /system #
show image
Displays the available software images for Cisco UCS Manager
(system).
Activates the selected firmware version on the system.
Use the ignorecompcheck keyword if you want to ignore the compatibility check and activate the firmware regardless of any possible incompatibilities or currently executing tasks.
Note
Activating Cisco UCS Manager does not require rebooting the fabric
interconnect; however, management services will briefly go down and all VSH
shells will be terminated as part of the activation.
Step 4
UCS-A /system #
commit-buffer
Commits the transaction.
Cisco UCS Manager makes the selected version the startup version and schedules the activation to occur when the fabric interconnects are upgraded.
The following example upgrades Cisco UCS Manager to version 1.2(1) and commits the transaction:
UCS-A# scope system
UCS-A# /system # show image
Name Type Version State
-------------------------------------------------- ---------------- ----------- -----
ucs-manager-k9.1.2.1.gbin System 1.2(1) Active
UCS-A# /system # activate firmware 1.2(1)
UCS-A# /system* # commit-buffer
UCS-A# /system #
Activating the Firmware on a Fabric Interconnect
When updating the firmware on two fabric interconnects in a high availability cluster configuration, you must activate the subordinate fabric interconnect before activating the primary fabric interconnect. For more information about determining the role for each fabric interconnect, see Verifying the High Availability Status and Roles of a Cluster Configuration.
Tip
If you ever need to recover the password to the admin account that was created when you configured the fabric interconnects for the Cisco UCS instance, you must know the running kernel version and the running system version. If you do not plan to create additional accounts, we recommend that you save the path to these firmware versions in a text file so that you can access them if required.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope fabric-interconnect {a |
b}
Enters fabric interconnect mode for the specified fabric
interconnect.
Step 2
UCS-A /fabric-interconnect #
show image
Displays the available software images for the fabric
interconnect.
Activates the selected firmware version on the fabric
interconnect.
Step 4
UCS-A /fabric-interconnect #
commit-buffer
Commits the transaction.
Cisco UCS Manager updates and activates the firmware, and then reboots the fabric interconnect and any I/O module in the data path to that fabric interconnect, disrupting data traffic to and from that fabric interconnect.
The following example upgrades the fabric interconnect to version
4.0(1a)N2(1.2.1) and commits the transaction:
UCS-A# scope fabric-interconnect a
UCS-A /fabric-interconnect # show image
Name Type Version State
--------------------------------------------- -------------------- ----------------- -----
ucs-6100-k9-kickstart.4.0.1a.N2.1.2.1.gbin Fabric Interconnect 4.0(1a)N2(1.2.1) Active
ucs-6100-k9-system.4.0.1a.N2.1.2.1.gbin Fabric Interconnect 4.0(1a)N2(1.2.1) Active
UCS-A /fabric-interconnect # activate firmware kernel-version 4.0(1a)N2(1.2.1) system-version 4.0(1a)N2(1.2.1)
UCS-A /fabric-interconnect* # commit-buffer
UCS-A /fabric-interconnect #
Updating Firmware through Service Profiles
Host Firmware Package
This policy enables you to specify a set of firmware versions
that make up the host firmware package (also known as the host firmware pack). The host firmware includes the following firmware for
server and adapter endpoints:
Adapter
BIOS
Board Controller
FC Adapters
HBA Option ROM
Storage Controller
Tip
You can include more than one type of firmware in the same host firmware package. For example, a host firmware package can include both BIOS firmware and storage controller firmware or adapter firmware for two different models of adapters. However, you can only have one firmware version with the same type, vendor, and model number. The system recognizes which firmware version is required for an endpoint and ignores all other firmware versions.
The firmware package is pushed to all servers associated with
service profiles
that include this policy.
This policy ensures that the host firmware is identical on all servers
associated with
service profiles
which use the same policy. Therefore, if you move the
service profile
from one server to another, the firmware versions are maintained. Also, if you
change the firmware version for an endpoint in the firmware package, new versions
are applied to all the affected service profiles immediately, which could cause
server reboots.
You must include this policy in a
service profile,
and that
service profile
must be associated with a server for it to take effect.
Prerequisites
This policy is not dependent upon any other policies. However, you
must ensure that the appropriate firmware has been downloaded to the fabric
interconnect. If the firmware image is not available when Cisco UCS Manager is associating a server with a service profile, Cisco UCS Manager ignores the firmware upgrade and completes
the association.
Creating and Updating a Host Firmware Package
If the policy is included in one or more service profiles associated with a server and those service profiles do not include maintenance policies, Cisco UCS Manager updates and activates the firmware in the server and adapter with
the new versions and reboots the server as soon as you save the host firmware package policy.
Tip
You can include more than one type of firmware in the same host firmware package. For example, a host firmware package can include both BIOS firmware and storage controller firmware or adapter firmware for two different models of adapters. However, you can only have one firmware version with the same type, vendor, and model number. The system recognizes which firmware version is required for an endpoint and ignores all other firmware versions.
Before You Begin
Ensure that the appropriate firmware has
been downloaded to the fabric interconnect.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope orgorg-name
Enters organization mode for the specified organization. To enter
the root organization mode, type
/ as the
org-name.
Step 2
UCS-A org/ #
create fw-host-packpack-name
Creates a host firmware package with the specified package name and
enters organization firmware host package mode.
Step 3
UCS-A /org/fw-host-pack #
set descrdescription
(Optional)
Provides a description for the host firmware package.
Note
If your description includes spaces, special characters, or
punctuation, you must begin and end your description with quotation marks. The
quotation marks will not appear in the description field of any
show command output.
Creates a package image for the host firmware package and enters
organization firmware host package image mode. The
hw-vendor-name and
hw-model values are labels that help you easily
identify the package image when you enter the
show image detail command. The
version-num value specifies the version number
of the firmware being used for the package image.
The model and model number (PID) must match the servers that are associated with this firmware package. If you select the wrong model or model number, Cisco UCS Manager cannot install the firmware update.
Step 5
UCS-A org/fw-host-pack/pack-image #
set versionversion-num
(Optional)
Specifies the package image version number. Changing this number
triggers firmware updates on all components using the firmware through a
service profile. Use this step only when updating a host firmware package, not
when creating a package.
Note
The host firmware package can contain multiple package images.
Repeat 4, and 5, to create additional package images for other components.
Step 6
UCS-A org/fw-host-pack/pack-image #
commit-buffer
Commits the transaction.
Cisco UCS Manager verifies the model numbers and vendor against all servers associated with service profiles that include this policy. If the model numbers and vendor match a firmware version in the policy, Cisco UCS Manager updates the firmware according to the settings in the maintenance policies included in the service profiles.
The following example creates the app1 host firmware package, creates a
storage controller package image with version 2009.02.09 firmware, and commits
the transaction:
Include the policy in a
service profile
and/or template.
Management Firmware Package
This policy enables you to specify a set of firmware versions
that make up the management firmware package (also known as a management firmware pack). The management firmware package includes the
Cisco Integrated Management Controller (CIMC) on the server.
You do not need to use this package if you upgrade the CIMC directly.
The firmware package is pushed to all servers associated with
service profiles
that include this policy.
This policy ensures that the CIMC firmware is identical on all servers
associated with service profiles
which use the same policy. Therefore, if you move the
service profile
from one server to another, the firmware versions are maintained.
You must include this policy in a
service profile,
and that service profile
must be associated with a server for it to take effect.
This policy is not dependent upon any other policies. However, you
must ensure that the appropriate firmware has been downloaded to the fabric
interconnect.
Creating and Updating a Management Firmware Package
Caution
If the policy is included in one or more service profiles associated with a server and those service profiles do not include maintenance policies, Cisco UCS Manager updates and activates the management firmware in the server with
the new versions and reboots the server as soon as you save the management firmware package policy
Before You Begin
Ensure that the appropriate firmware has
been downloaded to the fabric interconnect.
Procedure
Command or Action
Purpose
Step 1
UCS-A#
scope orgorg-name
Enters organization mode for the specified organization. To enter
the root organization mode, type
/ as the
org-name.
Step 2
UCS-A org/ #
create fw-mgmt-packpack-name
Creates a management firmware package with the specified package name
and enters organization firmware management package mode.
Step 3
UCS-A /org/fw-mgmt-pack #
set descrdescription
(Optional)
Provides a description for the management firmware package.
Note
If your description includes spaces, special characters, or
punctuation, you must begin and end your description with quotation marks. The
quotation marks will not appear in the description field of any
show command output.
Creates a package image for the management firmware package and
enters organization firmware management package image mode. The
hw-vendor-name and
hw-model values are labels that help you easily
identify the package image when you enter the
show image detail command. The
version-num value specifies the version number
of the firmware being used for the package image.
The model and model number (PID) must match the servers that are associated with this firmware package. If you select the wrong model or model number, Cisco UCS Manager cannot install the firmware update.
Step 5
UCS-A org/fw-mgmt-pack/pack-image #
set versionversion-num
(Optional)
Specifies the package image version number. Changing this number
triggers firmware updates on all components using the firmware through a
service profile. Use this step only when updating a firmware package, not
when creating a package.
Step 6
UCS-A org/fw-mgmt-pack/pack-image #
commit-buffer
Commits the transaction.
Cisco UCS Manager verifies the model numbers and vendor against all servers associated with service profiles that include this policy. If the model numbers and vendor match a firmware version in the policy, Cisco UCS Manager updates the firmware according to the settings in the maintenance policies included in the service profiles.
The following example creates the cimc1 host firmware package, creates a
CIMC package image with version 1.0(0.988) firmware, and commits the
transaction:
Include the policy in a
service profile
and/or template.
Managing the Capability Catalog
Capability Catalog
The capability catalog is a set of tunable parameters, strings, and rules. Cisco UCS Manager uses the catalog to update the display and configurability of components such as newly qualified DIMMs and disk drives for servers.
The catalog is divided by hardware components, such as the chassis, CPU, local disk, and I/O module. You can use the catalog to view the list of providers available for that component. There is one provider per hardware component. Each provider is identified by the vendor, model (PID), and revision. For each provider, you can also view details of the equipment manufacturer and the form factor.
The contents of the capability catalog include the following:
Implementation-Specific Tunable Parameters
Power and thermal
constraints
Slot ranges and
numbering
Adapter
capacities
Hardware-Specific Rules
Firmware compatibility for components such as the BIOS,
CIMC, RAID controller, and adapters
Diagnostics
Hardware-specific
reboot
User
Display Strings
Part numbers, such as the CPN,
PID/VID
Component
descriptions
Physical
layout/dimensions
OEM information
Updates to the Capability Catalog
Capability catalog updates are included in each Cisco UCS Manager update. Unless otherwise instructed by Cisco Technical Support, you only need to activate the capability catalog update after you've downloaded, updated, and activated an Cisco UCS Infrastructure Software Bundle.
As soon as you activate a capability catalog update, Cisco UCS Manager immediately updates to the new baseline catalog. You do not have to perform any further tasks. Updates to the capability catalog do not require you to reboot any component in the Cisco UCS instance or to reinstall Cisco UCS Manager.
Each Cisco UCS Manager release
contains a baseline catalog. In rare circumstances, Cisco releases an update to the capability catalog and makes it available on the same site where you download firmware images. The catalog update is compatible with Cisco UCS, Release 1.3(1) and later.
(Optional) Specifies the file transfer protocol for the remote server.
Note
TFTP has a file size limitation of 32 MB. Because catalog images can be much larger than that, we recommend that you do not use TFTP for catalog image downloads.
Step 8
UCS-A /system/capability/cat-updater # set server {hostname | ip-address}
(Optional) Specifies the hostname or IP address of the remote server.
Step 9
UCS-A /system/capability/cat-updater # set pathpathname/filename
(Optional) Specifies the path and file name of the capability catalog file on the remote server.
Step 10
UCS-A /system/capability/cat-updater # restart
Restarts the capability catalog file update operation.
The following example changes the server IP address and restarts the capability catalog file update operation:
UCS-A# scope system
UCS-A /system # scope capability
UCS-A /system/capability # show cat-updater
Catalog Updater:
File Name Protocol Server Userid Status
--------- -------- --------------- --------------- ------
ucs-catalog.1.0.0.4.bin
Scp 192.0.2.111 user1 Failed
UCS-A /system/capability # scope cat-updater ucs-catalog.1.0.0.4.bin
UCS-A /system/capability/cat-updater # set server 192.0.2.112
UCS-A /system/capability/cat-updater # restart
UCS-A /system/capability/cat-updater #
Viewing a Capability Catalog Provider
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope system
Enters system command mode.
Step 2
UCS-A /system # scope capability
Enters capability command mode.
Step 3
UCS-A /system/capability # show {chassis | cpu | disk | fan | fru | iom | memory | psu | server}
[vendormodelrevision] [detail | expand]
Displays vendor, model, and revision information for all components in the specified component category.
To view manufacturing and form factor details for a specific component, specify the vendor, model, and revision with the expand keyword. If any of these fields contains spaces, you must enclose the field with quotation marks.
Note
If the server contains one or more SATA devices, such as a hard disk drive or solid state drive, the show disk command displays ATA in the Vendor field. Use the expand keyword to display additional vendor information.
The following example lists the installed fans and displays detailed information from the capability catalog about a specific fan:
UCS-A# scope system
UCS-A /system # scope capability
UCS-A /system/capability # show fan
Fan Module:
Vendor Model Revision
------------------------ ------------------------ --------
Cisco Systems, Inc. N10-FAN1 0
Cisco Systems, Inc. N10-FAN2 0
Cisco Systems, Inc. N20-FAN5 0
UCS-A /system/capability # show fan "Cisco Systems, Inc." N10-FAN1 0 expand
Fan Module:
Vendor: Cisco Systems, Inc.
Model: N10-FAN1
Revision: 0
Equipment Manufacturing:
Name: Fan Module for UCS 6140 Fabric Interconnect
PID: N10-FAN1
VID: NA
Caption: Fan Module for UCS 6140 Fabric Interconnect
Part Number: N10-FAN1
SKU: N10-FAN1
CLEI:
Equipment Type:
Form Factor:
Depth (C): 6.700000
Height (C): 1.600000
Width (C): 4.900000
Weight (C): 1.500000
UCS-A /system/capability #
Click the link for the latest release of the capability catalog.
Step 7
Click one of the following buttons and follow the instructions provided:
Download Now—Allows you to download the catalog update immediately
Add to Cart—Adds the catalog update to your cart to be downloaded at a later time
Step 8
Follow the prompts to complete your download of the catalog update.
What to Do Next
Update the capability catalog.
Updating the Capability Catalog from a Remote Location
You cannot perform a partial update to the capability catalog. When you update the capability catalog, all components included in the catalog image are updated.
Procedure
Command or Action
Purpose
Step 1
UCS-A# scope system
Enters system command mode.
Step 2
UCS-A /system # scope capability
Enters capability command mode.
Step 3
UCS-A /system/capability # update catalogURL
Imports and applies the specified capability catalog file. Specify the URL for the operation using one of the following syntax:
ftp://username@hostname/path
scp://username@hostname/path
sftp://username@hostname/path
tftp://hostname:port-num/path
When a username is specified, you are prompted for a password.
Step 4
UCS-A /system/capability # show version
(Optional) Displays the catalog update version.
Step 5
UCS-A /system/capability # show cat-updaterfilename
(Optional) Displays the update history for a capability catalog file, if specified, or for all capability catalog file update operations.
Cisco UCS Manager downloads the image and updates the capability catalog. You do not need to reboot any hardware components.
The following example uses SCP to import a capability catalog file:
UCS-A# scope system
UCS-A /system # scope capability
UCS-A /system/capability # update catalog scp://user1@192.0.2.111/catalogs/ucs-catalog.1.0.0.4.bin
Password:
UCS-A /system/capability # show version
Catalog:
Update Version: 1.0(0.4)
UCS-A /system/capability # show cat-updater
Catalog Updater:
File Name Protocol Server Userid Status
--------- -------- --------------- --------------- ------
ucs-catalog.1.0.0.4.bin
Scp 192.0.2.111 user1 Success
UCS-A /system/capability #
Updating Management Extensions
Management Extensions
Management extension updates are included in each Cisco UCS Manager update. Unless otherwise instructed by Cisco Technical Support, you only need to activate the management extension update after you've downloaded, updated, and activated an Cisco UCS Infrastructure Software Bundle.
Management extensions enable you to add support for previously unsupported servers and other hardware to Cisco UCS Manager. For example, you may need to activate a management extension if you want to add a new, previously unsupported server to an existing Cisco UCS instance.
The management extension image contains the images, information, and firmware required by Cisco UCS Manager to be able to manage the new hardware.
Cisco UCS Manager may need to access a management extension when you activate. Therefore, the management extension is locked during the activation and update process.
Activating a Management Extension
The management extension is included in the server bundle that you have already downloaded. You do not need to download the management extension separately.
To verify the management extension version, issue the show version command.