Connector and Cable Specifications

Connector and Cable Specifications

This appendix contains these topics:

Connector Specifications

10/100/1000 Ports (Including PoE)

All 10/100/1000 ports use standard RJ-45 connectors and Ethernet pinouts.

Figure 1. 10/100/1000 Port Pinouts

SFP Module Connectors

Figure 2. Duplex LC Cable Connector



Figure 3. Simplex LC Cable Connector

Figure 4. Copper SFP Module RJ-45 Connector

Cables and Adapters

SFP Module Cables

Each port must match the wave-length specifications on the other end of the cable, and the cable must not exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters).

Table 1 Fiber-Optic SFP Module Port Cabling Specifications

SFP Module

Wavelength (nanometers)

Cable Type

Core Size/Cladding Size (micron)

Modal Bandwidth (MHz/km)

Cable Distance

GLC-GE-100FX

1310

MMF

50/125
62.5/125

500
500

6,562 feet (2 km) 
6,562 feet (2 km)

GLC-BX-D

1490 TX
1310 RX

SMF

G.652

32,810 feet (10 km)

GLC-BX-U

1310 TX
1490 RX

SMF

G.6522

32,810 feet (10 km)

GLC-EX-SMD

1310

SMF

G.6522

 

24.9 miles (40 km)

GLC-SX-MM

GLC-SX-MMD

850

MMF

62.5/125
62.5/125
50/125
50/125

160
200
400
500

722 feet (220 m)
902 feet (275 m)
1,640 feet (500 m)
1,804 feet (550 m)

GLC-T

Standard 4 twisted-pair Category 5 cable

328 feet (100 m)


GLC-LH-SM


GLC-LH-SMD

1310

MMF 


SMF

62.5/125
50/125
50/125
G.6522

500
400
500

1,804 feet (550 m)
1,804 feet (550 m)
1,804 feet (550 m)
32,810 feet (10 km)

GLC-ZX-SM

GLC-ZX-SMD

1550

SMF

G.6522

43.4 to 62 miles 
(70 to 100 km)

CWDM

1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610

SMF

G.6522

62 miles (100 km)

SFP-10G-LR

1310

SMF

G.6522

 

6.21 miles (10 km)

SFP-10G-SR

850

MMF

62.5/125
62.5/125
50/125
50/125
50/125

160
200
400
500
2000

85 feet (26 m)
108 feet (33 m)
216 feet (66 m)
269 feet (82 m)
6,561 feet (2000 m)

SFP-10G-ER

1550

SMF

G.6522

 

24.86 miles (40 km)5

SFP-10G-LRM

850

MMF

62.5/125
62.5/125
50/125
50/125
50/125

160
200
400
500
2000

722 feet (220 m)
722 feet (220 m)
328 feet (100 m)
722 feet (220 m)
722 feet (220 m)

SFP-H10GB-CU1M

SFP-H10GB-CU1.5M

SFP-H10GB-CU2M

SFP-H10GB-CU2-5M


SFP-H10GB-CU3M


SFP-H10GB-CU5M


Twinax cable, 30-AWG cable assembly


Twinax cable, 30-AWG cable assembly


Twinax cable, 30-AWG cable assembly


Twinax cable, 30-AWG cable assembly

Twinax cable, 30-AWG cable assembly

Twinax cable, 24-AWG cable assembly

3 feet (1 m)

5 feet (1.5 m)

6.5 feet (2.0 m)

8 feet (2.5 m)


9 feet (3 m)


16 feet (5 m)

1 Modal bandwidth applies only to multimode fiber.
2 A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers.
3 A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, or 1000BASE-LX/LH SFP modules and a short link distance can cause transceiver saturation, and an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).
4 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors.
5 For distances up to 30 km, no special link design rules need to be considered. Link distances beyond 30 km require that you verify the cable characteristics, especially the cable's loss value.

Cable Pinouts

Figure 5. Four Twisted-Pair Straight-Through Cable Schematic



Figure 6. Four Twisted-Pair Crossover Cable Schematic

Figure 7. Two Twisted-Pair Straight-Through Cable Schematic

Figure 8. Two Twisted-Pair Crossover Cable Schematic

Figure 9. Identifying a Crossover Cable

Console Port Adapter Pinouts

The RS-232 console port uses an 8-pin RJ-45 connector. Use an RJ-45-to-DB-9 adapter cable to connect the switch console port to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter to connect the switch console port to a terminal. You can order the kit (part number ACS-DSBUASYN=) from Cisco.

Table 2 Console Port Signaling with a DB-9 Adapter

Switch Console 
Port (DTE)

RJ-45-to-DB-9
Terminal Adapter

Console
Device

Signal

DB-9 Pin

Signal

RTS

8

CTS

DTR

6

DSR

TxD

2

RxD

GND

5

GND

GND

5

GND

RxD

3

TxD

DSR

4

DTR

CTS

7

RTS

Table 3 Console Port Signaling with a DB-25 Adapter

Switch Console
Port (DTE)

RJ-45-to-DB-25
Terminal Adapter

Console
Device

Signal

DB-25 Pin

Signal

RTS

5

CTS

DTR

6

DSR

TxD

3

RxD

GND

7

GND

GND

7

GND

RxD

2

TxD

DSR

20

DTR

CTS

4

RTS