Cisco MDS 9000 Family Command Reference, Release 1.2(2a)
R Commands

Table Of Contents

R Commands

radius-server host

radius-server key

radius-server retransmit

radius-server timeout

reload

rmdir

role name

rscn

run-script

rspan-tunnel


R Commands


The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. See the "Command Modes" section to determine the appropriate mode for each command. For more information, refer to the Cisco MDS 9000 Family Configuration Guide.

radius-server host

radius-server key

radius-server retransmit

radius-server timeout

reload

rmdir

role name

rscn

rspan-tunnel

run-script

radius-server host

To configure RADIUS authentication related parameters, use the radius command.

radius-server host server name or ip address [accounting] | [acct-port port number (accounting | authentication accounting) | primary accounting | authentication accounting] | [auth-port port number (accounting) (acct-port port number |accounting | authentication accounting | primary accounting | primary authentication)] | [authentication accounting] | [key shared secret] | [primary accounting | primary authentication]

no radius-server host server name or ip address [accounting] | [acct-port port number (accounting | authentication accounting) | primary accounting | authentication accounting] | [auth-port port number (accounting) (acct-port port number |accounting | authentication accounting | primary accounting | primary authentication)] | [authentication accounting] | [key shared secret] | [primary accounting | primary authentication]

Syntax Description

server name or ip address

Enter RADIUS server's DNS name or its IP address. The maximum character size is 256.

accounting

Use for accounting.

acct-port

RADIUS server's port for accounting.

authentication

Use for authentication.

key

RADIUS shared secret.

primary

Whether this RADIUS server is a primary server or not.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

None.

Examples

The following examples provide various scenarios to configure RADIUS authentication.

switch# config t

switch(config)# radius host 10.10.0.0 primary

switch(config)# radius host 10.10.0.0 key HostKey 

switch(config)# radius host 10.10.0.0 auth-port 2003 

switch(config)# radius host 10.10.0.0 acct-port 2004

switch(config)# radius host 10.10.0.0 accounting

switch(config)# radius host radius1 primary 

switch(config)# radius host radius2 key 0 abcd 

switch(config)# radius host radius3 key 7 1234 


radius-server key

To configure a global RADIUS shared secret, use the radius-server key command. Use the no form of this command to removed a configured shared secret.

radius-server key [0 | 7] shared secret

no radius-server key [0 | 7] shared secret

Syntax Description

key

Global RADIUS shared secret.

0

Configures a preshared key specified in clear text (indicated by 0) to authenticate communication between the RADIUS client and server. This is the default.

7

Configures a preshared key specified in encrypted text (indicated by 7) to authenticate communication between the RADIUS client and server.

shared secret

Configures a preshared key to authenticate communication between the RADIUS client and server.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

You need to configure the RADIUS preshared key to authenticate the switch to the RADIUS server. The length of the key is restricted to 65 characters and can include any printable ASCII characters (white spaces are not allowed). You can configure a global key to be used for all RADIUS server configurations on the switch. You can override this global key assignment by explicitly using the key option in the radius-server host command.

Examples

The following examples provide various scenarios to configure RADIUS authentication.


switch# config t

switch(config)# radius key AnyWord

switch(config)# radius key 0 AnyWord 

switch(config)# radius key 7 public 


radius-server retransmit

To specify the number of times that RADIUS servers should try to authenticate a user, use the radius-server retransmit command.

radius-server retransmit count

Syntax Description

retransmit

RADIUS server retransmit count.

count

Configures the number of times (3) the switch tries to connect to a RADIUS server(s) before reverting to local authentication.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

By default, a switch retries a RADIUS server connection only once. This number can be configured. The maximum is five retries per server. You can revert the retry number to its default by issuing the no radius-server retransmit command.

Examples

The following examples provide various scenarios to configure RADIUS authentication.


switch# config t

switch(config)# radius-server retransmit 3

radius-server timeout

To specify the time between retransmissions to the RADIUS servers, use the radius-server timeout command. You can revert the retransmission time to its default by issuing the no form of this command.

radius-server timeout seconds

no radius-server timeout seconds

Syntax Description

timeout

RADIUS server timeout period in seconds.

seconds

Specifies the time (in seconds) between retransmissions to the RADIUS server. The default is one (1) second and the valid range is 1 to 60 seconds.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

None.

Examples

The following examples provide various scenarios to configure RADIUS authentication.

switch# config t

switch(config)# radius-server timeout 30 

reload

To reload the entire switch, an active supervisor module, a standby supervisor module, or a specific module, or to force a netboot on a given module, use the reload command in EXEC mode.

reload [module module-number force-dnld]

Syntax Description

module

Reloads a specific module or active/standby supervisor module.

module-number

Specifies a module, either 1 or 2.

force-dnld

Reloads, initiates netboot, and forces the download of the latest module firmware version to a specific module.


Defaults

None.

Command Modes

EXEC mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

Use the reload command to reboot the system, or to reboot a specific module, or to force a netboot on a specific module. The reload command used by itself, powers down all the modules and reboots the supervisor modules.

The reload module module-number command is used if the given slot has a module or standby supervisor module. It then power-cycles that module. If the given slot has an active supervisor module, then it causes the currently active supervisor module to reboot and the standby supervisor module becomes active.

The reload module module-number force-dnld command is similar to the previous command. This command forces netboot to be performed. If the slot contains a module, then the module netboots with the latest firmware and updates its corresponding flash with this image.

Examples

The following example uses reload to reboot the system.

switch# reload
This command will reboot the system. (y/n)? y

The following example uses reload to initiate netboot on a specific module.

switch# reload module 8 force-dnld

The following example uses reload to reboot a specific module.

switch# reload module 8
reloading module 8 ...

The following example uses reload to reboot an active supervisor module.

switch# reload module 5
This command will cause supervisor switchover. (y/n)? y

Related Commands

Command
Description

install

Installs a new software image.

copy system:running-config nvram:startup-config

Copies any file from a source to a destination.


rmdir

To delete an existing directory from the Flash file system, use the rmdir command in EXEC mode.

rmdir {bootflash: | slot0: | volatile:} directory

Syntax Description

bootflash:

Source or destination location for internal bootflash memory.

slot0:

Source or destination location for the CompactFlash memory or PCMCIA card.

volatile:

Source or destination location for volatile file system.

directory

Name of the directory to remove.


Defaults

This command has no default settings.

Command Modes

EXEC

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

This command is only valid on Flash file systems.

The rmdir command deletes an existing directory at the current directory level or at a specified directory level. The directory must be empty to be deleted.

Examples

The following example deletes the directory called test in the slot0 directory.

switch# rmdir slot0:test 

The following example deletes the directory called test at the current directory level.

switch# rmdir test
 
If the current directory is slot0:mydir, this command deletes the slot0:mydir/test directory.

Related Commands

Command
Description

dir

Displays a list of files on a file system.

mkir

Creates a new directory in the Flash file system.


role name

To configure and assign users to a new role or to modify the profile for an existing role, use the role name command in configuration mode. Use the no form of this command to delete a configured role.

role name name [description user description] [ rule number permit clear feature name |permit config feature name | permit debug feature name | permit show feature name ] [ rule number deny clear feature name | deny config feature name | deny debug feature name | deny exec feature name | deny show feature name ]

no role name name [description user description] [ rule number permit clear feature name | permit config feature name | permit debug feature name | permit show feature name] [rule number deny clear feature name | deny config feature name | deny debug feature name | deny exec feature name | deny show feature nam ]

Syntax Description

role name

Configures RADIUS server.

name

Adds RADIUS server. The maximum size is 32.

description

Add a description for the role. The maximum size is 80.

user description

Add description of users to the role.

exit

Exit from this submode

no

Negate a command or set its defaults

rule

Enter the rule number 1-16.

number

Enter the rule number 1-16.

permit

Remove commands from the role.

deny

Add commands to the role

clear

Clear commands

config

Configuration commands

debug

Debug commands

show

Show commands

feature

Enter the feature name

exec

Exec commands

name

Enter the feature name (Max Size - 32)


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

Roles are assigned rules. Roles are a group of rules defining a user's access to certain commands. Users are assigned roles. The rules within roles can be assigned to permit or deny access to the following commands:
clear Clear commands
config Configuration commands
debug Debug commands
exec EXEC commands
show Show commands
These commands can have permit or deny options within that command line.

Examples

The following example shows how to assign users to a new role.

switch# config t
switch(config)# role name techdocs 
switch(config-role)# 
switch(config)# no role name techdocs 
switch(config)#
switch(config-role)# description Entire Tech. Docs. group
switch(config-role)# no description 
switch# config t
switch(config)# role name sangroup
switch(config-role)#
switch(config-role)# rule 1 permit config
switch(config-role)# rule 2 deny config feature fspf
switch(config-role)# rule 3 permit debug feature zone
switch(config-role)# rule 4 permit exec feature fcping
switch(config-role)# no rule 4

Role: network-operator
Description: Predefined Network Operator group. This role cannot be modified
Access to Show commands and selected Exec commands

Related Commands

Command
Description

show role

Displays all roles configured on the switch including the rules based on each role.


rscn

To configure a registered state change notification (RSCN), a Fibre Channel service that informs Nx ports about changes in the fabric, use the rscn command in configuration mode.

rscn {multi-pid value | supress interface fc slot-number }

Syntax Description

multi-pid

Sends RSCNs in multi-PID format.

vsan

Configures VSAN information or membership.

vsan-id

The ID of the VSAN is from 1 to 4093.

fc

Fiber Channel interface. Slot number range is from 1 to 9.

slot-number

Specifies a slot number and port number.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

None.

Examples

The following example configures RSCNs in multi-PID format.

switch# config t
excal-113(config)# rscn multi-pid vsan 1

Related Commands

Command
Description

show rscn internal

Displays RSCN internal information.

show rscn src-table

Displays state change registration table,

show rscn statistics

Displays RSCN statistics.


run-script

To execute the commands specified in a file, use the run script command.

run-script {bootflash: | slot0: | volatile:} filename

Syntax Description

bootflash:

Source or destination location for internal bootflash memory.

slot0:

Source or destination location for the CompactFlash memory or PCMCIA card.

volatile:

Source or destination location for volatile file system.

filename

Name of the file containing the commands.


Defaults

None.

Command Modes

EXEC mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.0(2).

Usage Guidelines

To use this command, be sure to create the file and specify commands in the required order.

Examples

The following example executes the CLI commands specified in the testfile that resides in the slot0 directory.


switch# show file slot0:testfile
conf t
interface fc 1/1
no shutdown
end
sh interface fc1/1

In response to the run-script command, this is the file output:

switch# run-script slot0:testfile
'conf t'
Enter configuration commands, one per line. End with CNTL/Z.

'interface fc 1/1'

'no shutdown'

'end'

'sh interface fc1/1'
fc1/1 is down (Fcot not present)
    Hardware is Fibre Channel
    Port WWN is 20:01:00:05:30:00:48:9e
    Admin port mode is auto, trunk mode is on
    vsan is 1
    Beacon is turned off
    Counter Values (current):
      0 frames input, 0 bytes, 0 discards
      0 runts, 0 jabber, 0 too long, 0 too short
      0 input errors, 0 CRC, 0 invalid transmission words
      0 address id, 0 delimiter
      0 EOF abort, 0 fragmented, 0 unknown class
      0 frames output, 0 bytes, 0 discards
      Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
      Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
    Counter Values (5 minute averages):
      0 frames input, 0 bytes, 0 discards
      0 runts, 0 jabber, 0 too long, 0 too short
      0 input errors, 0 CRC, 0 invalid transmission words
      0 address id, 0 delimiter
      0 EOF abort, 0 fragmented, 0 unknown class
      0 frames output, 0 bytes, 0 discards
      Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
	  Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits

rspan-tunnel

To associate and bind the SPAN tunnel (ST) port with the RSPAN tunnel, use the rspan-tunnel command.

rspan-tunnel interface fc-tunnel tunnel-id

Syntax Description

rspan-tunnel

Configures the remote SPAN (RSPAN) tunnel.

interface

Specifies the interface to configure this tunnel.

fc-tunnel

Specifies the FC tunnel interface.

tunnel-id

Configures an ID that ranges from 1 to 255.


Defaults

None.

Command Modes

Configuration mode.

Command History

This command was introduced in Cisco MDS SAN-OS Release 1.2(1).

Usage Guidelines

The interface is not operationally up until the Fibre Channel tunnel mapping is configured in the source and destination switches.

Examples

The following example configures an interface to associate and bind the ST port with the RSPAN tunnel and enables traffic flow trough this interface..

switchS# config t 
switchS(config)# interface fc2/1 
switchS(config-if)# rspan-tunnel interface fc-tunnel 100 