Cisco Firepower 4115機箱出現意外重新啟動,無法恢復運行狀態。觀察到以下症狀:
FMC UI將FTD狀態顯示為「Disabled」。
機箱管理器UI顯示具有狀態的邏輯例項:安全模組故障。

機箱管理器UI將安全引擎顯示為Degraded。

DDR4/DIMM記憶體、安全模組和儲存的多個相關故障出現在FXOS CLI中。
fxos# show fault
Severity Code Last Transition Time ID Description
--------- -------- ------------------------ -------- -----------
Critical F1236 2026-06-26T05:50:35.387 2443029 Health LED of server 1/1 shows error. Reason: DDR4_P1_A1_ECC:Sensor Threshold Crossed;
Major F1546 2026-06-26T22:11:30.870 2443026 Security Module 1 is in failed state. Error: Security module is downgraded (or) not acknowledged. Reason: DIMM or CPU degraded
Major F0317 2026-06-26T22:05:08.375 2443211 Server 1/1 (service profile: org-root/ls-ssp-sprof-1) health: inoperable
Major F1761 2026-06-26T05:52:40.467 2443450 Physical memory size 180224 on server 1/1 is smaller than expected.
Major F0185 2026-06-26T05:31:08.858 2442844 DIMM DIMM_A1 on server 1/1 operability: inoperable
Info F0461 2025-08-26T04:24:40.271 1895361 Log capacity on Management Controller on server 1/1 is very-low
機箱伺服器和記憶體狀態詳細資訊顯示無法運行的DIMM元件。
fxos# show server status detail
Server 1/1:
Slot Status: Equipped
Equipped Conn Path: A
Equipped Conn Status: A
Equipped Managing Instance: A
Availability: Unavailable
Admin State: In Service
Overall Status: Degraded
Oper Qualifier: Memory Inoperable
Discovery: Complete
Current Task:
Check Point: Discovered
fxos# show server memory detail
Server 1/1:
Array 1:
CPU ID: 1
Current Capacity (MB): 180224
Error Correction: Undisc
Max Capacity (MB): 9437184
Max Devices: 24
Populated: 12
DIMMS:
ID 1:
Location: DIMM_A1
Presence: Equipped
Overall Status: Inoperable
Visibility: No
Vendor: NO DIMM
Vendor Part Number: NO DIMM
Vendor Serial (SN): NO DIMM
HW Revision: 0
Form Factor: Unknown
Type: Unknown
Capacity (MB): Unknown
Clock: Unknown
Latency: 2917376161116564280513419804672.000000
Width: 14400
Cisco Firepower 4100安全裝置(FPR-4115-K9)
首次在FXOS版本上看到:2.14(1.167)
FTD版本:7.4.7.50(運行)、6.4.0.102(啟動)
通過FMC管理實現高可用性配置
記憶體配置:12個16GB DDR4模組,2666 MHz
受影響的DIMM:記憶體插槽1中的DIMM_A1
1.執行機箱重新啟動以嘗試記憶體故障恢復:
fxos# scope chassis
fxos /chassis # reboot
fxos /chassis* # commit-buffer
2.分配完整系統引導的時間後,在FXOS CLI和機箱管理器UI中重新驗證元件狀態故障狀態。
3.如果DIMM故障在完全重啟後仍然存在,則需要通過Cisco RMA更換硬體。
診斷程式確認了一個嚴重的記憶體子系統故障,其中超出了DDR4_P1_A1_ECC感測器閾值,表明在意外機箱重新啟動後模組完全出現故障。DIMM A1報告了「無法操作」狀態,所有SPD(串列存在檢測)資料都不可讀,確認不可逆的硬體故障,而不是通過正常重新啟動無法恢復的暫時性錯誤。記憶體故障導致安全模組和FTD邏輯例項無法正確初始化,導致機箱重新啟動後仍存在「無法操作」的機箱狀態。
| 修訂 | 發佈日期 | 意見 |
|---|---|---|
1.0 |
02-Nov-2026
|
初始版本 |