Este documento descreve um problema que o motor 3500 da experiência dos media (MXE 3500) possa experimentar no processo do bootup com a unidade de bateria de backup (BBU) do controlador de MegaRAID.
As exibições de console este Mensagem de Erro quando houver um problema com o BBU:
The battery hardware is missing or malfunctioning, or the
battery is unplugged, or the battery could be fully
discharged. If you continue to boot the system, the
battery-backed cache will not function. If battery is
connected and has been allowed to charge for 30
minutes and this message continues to appear, then
contact technical support for assistance. Press 'D'
to disable this warning (if your controller does
not have a battery).
...
Press any key to continue, or 'C' to load the
configuration utility.
Se você pressiona qualquer chave o dispositivo carreg acima, mas não é claro se a bateria está em um bom estado ou não.
Veja estabelece CIMC para o server da série C UCS para obter informações sobre de como configurar o controlador do gerenciamento integrado de Cisco (CIMC).
A primeira etapa é verificar o MXE 3500 a fim considerar se reconhece o BBU. Use um cliente do Shell Seguro (ssh) para conectar ao MXE 3500 com o endereço de gerenciamento CIMC. Incorpore os comandos mostrados em corajoso a este exemplo:
MXE-3500-1# scope chassis
MXE-3500-1 /chassis # show detail
Chassis:
Power: on
Serial Number: xxxxxxxxxx
Product Name:
PID : MXE-3500-V2-K9=
UUID: xxxxxxxxxx
Locator LED: off
Description:
Power Restore Policy: restore-last-state
Power Delay Type: fixed
Power Delay Value(sec): 0
MXE-3500-1 /chassis # show pci-adapter detail
Slot 6:
Vendor ID: 0x14e4
Device ID: 0x1639
SubVendor ID: 0x14e4
SubDevice ID: 0x1639
Product Name : Broadcom 5709 1 Gbps 2-or-4 port NIC
Slot 7:
Vendor ID: 0x1000
Device ID: 0x0079
SubVendor ID: 0x1000
SubDevice ID: 0x9260
Product Name : LSI 9260-4i MegaRAID SAS HBA
## Note the slot number the MegaRAID controller is installed in.
## This slot number is used in the next command.
MXE-3500-1 /chassis # scope storageadapter SLOT-7
MXE-3500-1 /chassis/storageadapter # show detail
PCI Slot SLOT-7:
Info Valid: Yes
Info Invalid Cause:
Product Name: LSI MegaRAID SAS 9260-4i
Serial Number: xxxxxxxxx
Firmware Package Build: 12.12.0-0087
Product ID: LSI Logic
Battery Status: charging
Cache Memory Size: 0 MB
MXE-3500-1 /chassis/storageadapter # show bbu detail
Controller SLOT-7:
Info Valid: Yes
Info Invalid Cause:
Battery Type: iBBBU08
Battery Present: true
Voltage: 4.086 V
Current: 0.000 A
Charge: 100%
Charging State: charging
Temperature: 32 degrees C
Voltage Low: false
Temperature High: false
Learn Cycle Requested: false
Learn Cycle Active: false
Learn Cycle Failed: false
Learn Cycle Timeout: false
I2C Errors Detected: false
Battery Replacement Required: false
Remaining Capacity Low: false
MXE-3500-1 /chassis/storageadapter #
No exemplo você pode ver que o BBU esta presente, está carregando, e mostra um status normal.
Termine estas etapas se você recebe um Mensagem de Erro quando você inscreve o comando detail do bbu da mostra ou se o estado atual da bateria é falso:
Recarregue o MXE 3500.
Se “o hardware da bateria falta ou” a mensagem funcionando mal continua a indicar depois que cada repartição, pôde haver uma falha do hardware do BBU. Contacte o centro de assistência técnica da Cisco (TAC) para a assistência adicional.
Se as botas do dispositivo acima sem um erro ele puderam ter sido um erro transitório. Nenhuma ação mais adicional é exigida.