이 문서에서는 MegaRAID 컨트롤러의 BBU(Battery Backup Unit)를 사용하여 부팅 프로세스에서 MXE 3500(Media Experience Engine 3500)이 경험할 수 있는 문제를 설명합니다.
BBU에 문제가 있는 경우 콘솔에 다음 오류 메시지가 표시됩니다.
The battery hardware is missing or malfunctioning, or the
battery is unplugged, or the battery could be fully
discharged. If you continue to boot the system, the
battery-backed cache will not function. If battery is
connected and has been allowed to charge for 30
minutes and this message continues to appear, then
contact technical support for assistance. Press 'D'
to disable this warning (if your controller does
not have a battery).
...
Press any key to continue, or 'C' to load the
configuration utility.
키를 누르면 장치가 부팅되지만 배터리가 정상 상태인지 여부가 명확하지 않습니다.
CIMC(Cisco Integrated Management Controller)를 구성하는 방법에 대한 자세한 내용은 UCS C-Series 서버에 대한 CIMC 설정을 참조하십시오.
첫 번째 단계는 MXE 3500이 BBU를 인식하는지 확인하는 것입니다.SSH(Secure Shell) 클라이언트를 사용하여 CIMC 관리 주소가 있는 MXE 3500에 연결합니다.다음 예에서는 굵게 표시된 명령을 입력합니다.
MXE-3500-1# scope chassis
MXE-3500-1 /chassis # show detail
Chassis:
Power: on
Serial Number: xxxxxxxxxx
Product Name:
PID : MXE-3500-V2-K9=
UUID: xxxxxxxxxx
Locator LED: off
Description:
Power Restore Policy: restore-last-state
Power Delay Type: fixed
Power Delay Value(sec): 0
MXE-3500-1 /chassis # show pci-adapter detail
Slot 6:
Vendor ID: 0x14e4
Device ID: 0x1639
SubVendor ID: 0x14e4
SubDevice ID: 0x1639
Product Name : Broadcom 5709 1 Gbps 2-or-4 port NIC
Slot 7:
Vendor ID: 0x1000
Device ID: 0x0079
SubVendor ID: 0x1000
SubDevice ID: 0x9260
Product Name : LSI 9260-4i MegaRAID SAS HBA
## Note the slot number the MegaRAID controller is installed in.
## This slot number is used in the next command.
MXE-3500-1 /chassis # scope storageadapter SLOT-7
MXE-3500-1 /chassis/storageadapter # show detail
PCI Slot SLOT-7:
Info Valid: Yes
Info Invalid Cause:
Product Name: LSI MegaRAID SAS 9260-4i
Serial Number: xxxxxxxxx
Firmware Package Build: 12.12.0-0087
Product ID: LSI Logic
Battery Status: charging
Cache Memory Size: 0 MB
MXE-3500-1 /chassis/storageadapter # show bbu detail
Controller SLOT-7:
Info Valid: Yes
Info Invalid Cause:
Battery Type: iBBBU08
Battery Present: true
Voltage: 4.086 V
Current: 0.000 A
Charge: 100%
Charging State: charging
Temperature: 32 degrees C
Voltage Low: false
Temperature High: false
Learn Cycle Requested: false
Learn Cycle Active: false
Learn Cycle Failed: false
Learn Cycle Timeout: false
I2C Errors Detected: false
Battery Replacement Required: false
Remaining Capacity Low: false
MXE-3500-1 /chassis/storageadapter #
이 예에서는 BBU가 존재하고 충전 중이며 정상 상태를 보여줍니다.
show bbu detail 명령을 입력할 때 오류 메시지가 표시되거나 Battery Present(배터리 있음) 상태가 false인 경우 다음 단계를 완료합니다.
MXE 3500을 재부팅합니다.
재부팅할 때마다 '배터리 하드웨어가 없거나 작동하지 않음' 메시지가 계속 표시되면 BBU의 하드웨어 오류가 발생할 수 있습니다.자세한 내용은 Cisco TAC(Technical Assistance Center)에 문의하십시오.
오류 없이 디바이스를 부팅하는 경우 일시적인 오류가 발생했을 수 있습니다.추가 조치는 필요하지 않습니다.