Tarjeta | Consumo aproximado de energía | Niveles de fibra de luz | |||
---|---|---|---|---|---|
AMPS | Vatios | BTU por hora | ‘Nivel Rx’ | Nivel Tx | |
Max. Dibujar con tarjetas | 22.63 | 1088.64 | 3714.59 | ||
BANDEJA DE VENTILADOR: FTA2 | 1.21 | 58.00 | 198.00 | ||
BANDEJA DE VENTILADOR: FTA3-T | 1.98 | 95.00 | 324.00 | ||
XC | 0.28 | 13.00 | 46.00 | ||
XCVT | 0.72 | 34.40 | 117.46 | ||
XC10G | 1.64 | 78.60 | 268.40 | ||
TCC | 0.20 | 9.82 | 33.53 | ||
TCC+ | 0.20 | 9.82 | 33.53 | ||
AIC | 0.12 | 6.01 | 20.52 | ||
AIC-I | 0,17 | 8.00 | 27.30 | ||
DS1-14 | 0.26 | 12.60 | 43.02 | ||
DS1N-14 | 0.26 | 12.60 | 43.02 | ||
DS3-12E | 0.79 | 38.20 | 130.43 | ||
DS3N-12E | 0.79 | 38.20 | 130.43 | ||
DS3XM-6 | 0.42 | 20.00 | 68.00 | ||
EC1-12 | 0.76 | 36.60 | 124.97 | ||
E100T-G | 1.35 | 65.00 | 221.93 | ||
E1000-2-G incl. GBIC | 1.11 | 53.50 | 182.67 | ||
G1000-4 incl. GBIC | 1.31 | 63.00 | 215.11 | Máx.: mín. | Máx.: mín. |
OC3IR4-1310 | 0.40 | 13.20 | 65.56 | -8 a -28 | -8 a -15 |
OC12IR-1310 | 0.23 | 10.90 | 37.22 | -8 a -28 | -8 a -15 |
OC12LR-1310 | 0.25 | 9.28 | 41.00 | -8 a -28 | +2 a -3 |
OC12LR-1550 | 0.19 | 9.28 | 31.68 | -8 a -28 | +2 a -3 |
OC12IR4-1310 | 0.58 | 28.00 | 100.00 | -8 a -30 | -8 a -15 |
OC48IR-1310 de alta velocidad | 0.67 | 32.20 | 109.94 | 0 a -18 | 0 a -5 |
OC48LR-1550 de alta velocidad | 0.56 | 26.80 | 91.50 | -8 a -28 | +3 a -2 |
OC48IR-1310 Cualquier ranura | 0.77 | 37.20 | 127.01 | 0 a -18 | 0 a -5 |
OC48LR-1550 Any Slot | 0.77 | 37.20 | 127.01 | -8 a -28 | +3 a -2 |
OC48ELR-ITU 100 GHz | 0.65 | 31.20 | 106.53 | -9 a -27 | 0 a -2 |
OC48ELR-ITU 200 GHz | 0.65 | 31.20 | 106.53 | -8 a -28 | 0 a -2 |
OC192LR-1550 | 1.50 | 72.20 | 246.52 | -10 a -19 | +10 a +7 |