The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
Wireless Advanced Settings
Wireless Advanced Settings
On the Configuration > Wireless > Advanced page, you can perform the following advanced tasks:
In the Load Balancing tab, in the Aggressive Load Balancing Window (Clients) field, enter a value between 1 and 20 to specify the load-balancing window and the number of client associations on the AP with the lightest load. For example, consider AP1 has the least number of clients (6), and the window size is set to 5, then each AP connected to the device can have 11 clients. As a result, every 12th client is load balanced, and a denial response is sent based on the configured value for the maximum denial count.
In the Aggressive Load Balancing Denial Count field, enter a value between 0 and 10 to specify the number of times the client associations will be rejected for a particular AP.
Note: In the Load Balancing Statistics area, you can view the load balancing statistical data.
In the Band Select tab, enter a value between 1 and 10 in the Cycle Count field. The cycle count sets the number of suppression cycles for a new client. The default cycle count is 2.
In the Cycle Threshold field, enter a value between 1 and 1000 milliseconds for the scan cycle period threshold. This setting determines the time threshold during which new probe requests from a client come from a new scanning cycle. The default cycle threshold is 200 milliseconds.
In the Age Out Suppression field, enter a value between 10 and 200 seconds. Age-out suppression sets the expiration time for pruning previously known 802.11b/g/n clients. The default value is 20 seconds. After this time elapses, clients become new and are subject to probe response suppression.
In the Age Out Dual Band field, enter a value between 10 and 300 seconds. The age-out period sets the expiration time for pruning previously known dual-band clients. The default value is 50 seconds. After this time elapses, clients become new and are subject to probe response suppression.
In the Client RSSI field, enter a value between -90 dBm and -20 dBm. This is the minimum RSSI for a client to respond to a probe.
In the Client Mid RSSI field, enter a value between –20 dBm and –90 dBm. This parameter sets the mid-RSSI, whose value can be used for toggling 2.4 GHz probe suppression based on the RSSI value.