Configure Windows SMBDirect RoCEv2 Interface using UCS Manager CLI
Use the following steps to configure the RoCEv2 interface in the Cisco UCS Manager CLI.
Before you begin
You must log in with admin privileges.
Procedure
Command or Action | Purpose | |
---|---|---|
Step 1 |
Example:
|
Enter the service profile for the specified chassis, blade or UCS managed rack server ID. |
Step 2 |
Example:
|
Display the vNICs available on the server. |
Step 3 |
Example:
|
Enter the vnic mode for the specified vNIC. |
Step 4 |
To configure Windows SMBDirect RoCEv2 Mode 1: Example:
|
Specifies a Windows SMBDirect RoCEv2 adapter policy for RoCEv2 Mode 1. |
Step 5 |
To configure Windows SMBDirect RoCEv2 Mode 2: Example:
|
Configures Windows Mode 2, after creating a VMQ connection policy and assigning the adapter policy MQ-SMBd: |
Step 6 |
Example:
|
Commit the transaction to the system configuration. |
This example shows how to configure the RoCEv2 Win-HPN-SMBd adapter policy:
UCS-A# scope service-profile server 1/1
UCS-A /org/service-profile # show vnic
vNIC:
Name Fabric ID Dynamic MAC Addr Virtualization Preference
-------- ------------- ---------------------------- ----------------------------------
eth00 A B 00:25:B5:3A:84:00 NONE
eth01 A 00:25:B5:3A:84:01 NONE
eth02 B 00:25:B5:3A:84:02 NONE
UCS-A /org/service-profile # scope vnic eth01
UCS-A /org/service-profile/vnic # set adapter-policy Win-HPN-SMBd
UCS-A /org/service-profile/vnic* # commit-buffer
UCS-A /org/service-profile/vnic #