Managing Firmware
Upgrades
This chapter discusses the following topics:
- About Upgrading Firmware on Rack Servers
- Adding Images to a Local Cisco UCS Director System
- Uploading Images from a Local File System
- Adding Images from a Network Server
- Upgrading the Firmware Image
- Deleting the Firmware Image
- Deleting a Profile Created for Firmware Upgrade
- Clearing Firmware Upgrade Status Messages
About Upgrading Firmware on Rack Servers
In Cisco UCS Director, you can create firmware upgrade profiles and then use these profiles to upgrade the firmware on rack servers. You can create the following types of firmware upgrade profiles:
-
Profile for locally stored firmware images.
For more information on creating this profile, see Adding Images to a Local Cisco UCS Director System
-
Profile for firmware images stored on the network.
For more information on creating this profile, see Adding Images from a Network Server
Adding Images to a Local Cisco UCS Director System
Uploading Images from a Local File System
Perform this procedure to upload iso images from your local file system to the system.
| Step 1 | Choose . | ||||||||
| Step 2 | On the Physical Accounts page, click Images - Local. | ||||||||
| Step 3 | Click Upload to add an image. | ||||||||
| Step 4 | In the
Upload
Firmware Image - Local screen, complete the required fields,
including the following:
| ||||||||
| Step 5 | Click Upload. | ||||||||
| Step 6 | Click OK in the File Upload confirmation screen, once the upload is complete. | ||||||||
| Step 7 | Click
Close.
|
Adding Images from a Network Server
| Step 1 | Choose . | ||||||||||||||||||||
| Step 2 | On the Physical Accounts page, click Images - Network. | ||||||||||||||||||||
| Step 3 | Click Add. | ||||||||||||||||||||
| Step 4 | In the
Add
Firmware Image - Network screen, complete the required fields,
including the following:
| ||||||||||||||||||||
| Step 5 | Click
Submit.
|
Upgrading the Firmware Image
Perform this procedure when you want to upgrade firmware on a rack server.
| Step 1 | Choose . | ||||||||
| Step 2 | On the Physical Accounts page, click Firmware Upgrades. | ||||||||
| Step 3 | Click
Run
Upgrade.
A warning message stating that the firmware upgrade process will result in downtime of the hosts is displayed. | ||||||||
| Step 4 | Click OK to confirm. | ||||||||
| Step 5 | In the
Upgrade
Firmware screen, complete the following:
| ||||||||
| Step 6 | Click Submit. |
Deleting the Firmware Image
Perform this procedure when you want to delete only the firmware image and not the profile using which the firmware image was downloaded.
| Step 1 | Choose . |
| Step 2 | On the Physical Accounts page, click Images - Local. |
| Step 3 | Select a profile from the table. |
| Step 4 | Click Delete Image. |
| Step 5 | In the
Delete
Image(s) screen, click
Delete.
The firmware image is deleted from the system. You can download this firmware image from later on by using the Download Image option. |
Deleting a Profile Created for Firmware Upgrade
Perform this procedure when you want to delete a profile created for firmware upgrade.
Clearing Firmware Upgrade Status Messages
Perform this procedure to clear all firmware-related status messages recorded in the Cisco UCS Director system.