- Preface
- New and Changed Information for this Release
- Overview
- Configuring Rack Accounts and Rack Groups
- Managing Rack Server Discovery
- Managing Rack Servers
- Managing Cisco UCS C3260 Servers
- Managing Rack Server Policies and Profiles
- Managing Firmware Upgrades
- Monitoring and Reporting
- Using Orchestration Workflows
Monitoring and
Reporting
- About Monitoring and Reporting
- Monitoring a Rack Server and Its Components
- Viewing Reports About a Rack Server
- Clearing SEL
- Uploading Technical Support Data to a Server
- Configuring Email Alert Rules
- Server Diagnostics
- Configuring an SCP User Password
About Monitoring and Reporting
Cisco UCS Director displays all managed components in each rack-mount server that has been added to a rack group. These components can be hardware or software.
Information You Can View
You can view and monitor details about each component, including the following:
Components You Can Monitor
You can monitor specific components or view reports for each of the components, including the following:
Email Alerts
You can configure rules in Cisco UCS Director so that an email message is triggered when faults of a certain severity occur on rack servers or rack server groups. When fault conditions specified in the rule occur, an email message is triggered and sent to the recipients you have specified. For information on configuring these email alert rules, see Configuring Email Alert Rules.
Monitoring a Rack Server and Its Components
Viewing Reports About a Rack Server
| Step 1 | On the menu bar, choose . |
| Step 2 | In the left pane, expand the pod that contains the rack server group and then choose the rack server group. |
| Step 3 | In the right pane, click the Rack Server tab. |
| Step 4 | Choose the row of the server for which you want to view reports. |
| Step 5 | In the right pane, click the Summary tab to view a wide array of tabular, graphical, and map reports that provide a view of trending data for the account. |
| Step 6 | For some
reports, you can click the icons on the table bar to customize the table
columns, filter the results, or export a report of the current table contents.
For more information, see the Cisco UCS Director Administration Guide. |
Clearing SEL
Uploading Technical Support Data to a Server
Configuring Email Alert Rules
| Step 1 | On the menu bar, choose . | ||||||||||||||||
| Step 2 | Choose the Email Alert Rules tab. | ||||||||||||||||
| Step 3 | Click Add (+). | ||||||||||||||||
| Step 4 | In the
Add Email
Alert Rule dialog box, complete the following fields:
| ||||||||||||||||
| Step 5 | Click Submit. |
Server Diagnostics
Overview of Server Diagnostics
Server diagnostics is available through UCS Server Configuration Utility (UCS-SCU). You can use diagnostics tools to diagnose hardware problems with your Cisco servers and run tests on various server components to find out hardware issues along with analysis of the test results in a tabular format.
You must download, configure, and save the UCS-SCU image to a remote location.
![]() Note | Running a diagnostic test using the UCS-SCU image results in the server being temporarily unavailable as the server reboots with the UCS-SCU image. |
![]() Note | You must configure the scpuser password to run server diagnostics. To configure the scpuser password, see Configuring an SCP User Password. |
Configuring Server Configuration Utility Image Location
Perform this procedure to configure and save the location of the UCS-SCU image.
| Step 1 | On the menu bar, choose . | ||||||||||||||
| Step 2 | Choose the SCU Image Profiles tab. | ||||||||||||||
| Step 3 | Click Add. | ||||||||||||||
| Step 4 | In the
Configure SCU Image Location dialog box, complete
the following:
| ||||||||||||||
| Step 5 | Click Save. | ||||||||||||||
| Step 6 | In the Submit Result dialog box, click OK. |
Running Diagnostics
Perform this procedure when you want to run diagnostics for servers or server groups. Running diagnostics on servers will result in the selected servers being restarted.
| Step 1 | On the menu bar, choose . | ||||||
| Step 2 | Choose the Server Diagnostics tab. | ||||||
| Step 3 | Click Run Diagnostics. | ||||||
| Step 4 | In the
Run
Diagnostics dialog box, complete the following:
| ||||||
| Step 5 | Click
Submit.
|
Configuring an SCP User Password
An SCP user is used by server diagnostics and tech support upload operations for transferring files to the Cisco IMC Supervisor appliance using the SCP protocol. An scp user account cannot be used to login to the Cisco IMC Supervisor UI or the shelladmin. You must create an SCP user using Putty, and then log in to the user interface to set a password.
Complete this procedure to configure a password for an SCP user.

Feedback