- Preface
- Overview
- Installing the Server Operating System or Hypervisor
- Managing the Server
- Managing Storage Using RAID
- Viewing Server Properties
- Viewing Server Sensors
- Managing Remote Presence
- Managing User Accounts
- Configuring Network-Related Settings
- Configuring Communication Services
- Managing Certificates
- Configuring Platform Event Filters
- Firmware Management
- Viewing Logs
- Server Utilities
- Diagnostic Tests
- Index
Contents
- Viewing Server Sensors
- Viewing the Fault Summary
- Viewing Temperature Sensors
- Viewing Voltage Sensors
- Viewing LED Sensors
- Viewing Storage Sensors
Viewing Server Sensors
This chapter includes the following sections:
- Viewing the Fault Summary
- Viewing Temperature Sensors
- Viewing Voltage Sensors
- Viewing LED Sensors
- Viewing Storage Sensors
Viewing the Fault Summary
This example displays a summary of faults from discrete sensors:
Server# scope fault Server /fault # show discrete-alarm Name Reading Sensor Status ------------ -------------------- ------------------------------------ PSU2_STATUS absent Critical Server /fault #
Viewing Temperature Sensors
| Command or Action | Purpose |
|---|
This example displays temperature sensor statistics:
Server# scope sensor Server /sensor # show temperature Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ IOH_TEMP_SENS Normal 32.0 C N/A 80.0 N/A 85.0 P2_TEMP_SENS Normal 31.0 C N/A 80.0 N/A 81.0 P1_TEMP_SENS Normal 34.0 C N/A 80.0 N/A 81.0 DDR3_P2_D1_TMP Normal 20.0 C N/A 90.0 N/A 95.0 DDR3_P1_A1_TMP Normal 21.0 C N/A 90.0 N/A 95.0 FP_AMBIENT_TEMP Normal 28.0 C N/A 40.0 N/A 45.0 Server /sensor #
Viewing Voltage Sensors
| Command or Action | Purpose |
|---|
This example displays voltage sensor statistics:
Server# scope sensor Server /sensor # show voltage Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ P3V_BAT_SCALED Normal 3.022 V N/A N/A 2.798 3.088 P12V_SCALED Normal 12.154 V N/A N/A 11.623 12.331 P5V_SCALED Normal 5.036 V N/A N/A 4.844 5.157 P3V3_SCALED Normal 3.318 V N/A N/A 3.191 3.381 P5V_STBY_SCALED Normal 5.109 V N/A N/A 4.844 5.157 PV_VCCP_CPU1 Normal 0.950 V N/A N/A 0.725 1.391 PV_VCCP_CPU2 Normal 0.891 V N/A N/A 0.725 1.391 P1V5_DDR3_CPU1 Normal 1.499 V N/A N/A 1.450 1.548 P1V5_DDR3_CPU2 Normal 1.499 V N/A N/A 1.450 1.548 P1V1_IOH Normal 1.087 V N/A N/A 1.068 1.136 P1V8_AUX Normal 1.773 V N/A N/A 1.744 1.852 Server /sensor #
Viewing LED Sensors
The server must be powered on, or the information will not display.
| Command or Action | Purpose |
|---|
This example displays information about the external LEDs:
Server# scope chassis
Server /chassis # show led
LED Name LED State LED Color
------------------------- ---------- --------
LED_SYS_ACT OFF GREEN
LED_HLTH_STATUS ON GREEN
Server /chassis # show led detail
LEDs:
LED Name: LED_SYS_ACT
LED State: OFF
LED Color: GREEN
LEDs:
LED Name: LED_HLTH_STATUS
LED State: ON
LED Color: GREEN
ucs-e160dp-m1 /chassis #
Viewing Storage Sensors
| Command or Action | Purpose |
|---|
Name column The name of the storage device. This can be: HDDX_PRS—Indicates the presence or absence of each hard drive.
Status column A brief description of the status of the storage device.
LED Status column The current LED color, if any. To make the physical LED on the storage device blink, select Turn On from the drop-down list. To let the storage device control whether the LED blinks, select Turn Off.Name
Description
This example displays storage sensor information:
Server# scope chassis Server /chassis # show hdd Name Status -------------------- -------------------- HDD1_PRS inserted HDD2_PRS inserted HDD3_PRS inserted Server /chassis #