| Fan Info |
|
Name column
|
The designated name of the fan.
|
|
MemberId column
|
A unique identifier for the fan within its group.
|
|
PhysicalContext column
|
Describes the physical location or context of the fan.
|
|
State column
|
The current operational state or health status of the fan.
|
|
Reading(RPM) column
|
The current rotational speed of the fan, measured in revolutions per minute (RPM).
|
|
MinReadingRange column
|
The minimum value of the normal operating range for the fan speed.
|
|
MaxReadingRange column
|
The maximum value of the normal operating range for the fan speed.
|
|
UF column
|
Upper Fatal threshold for the fan speed.
|
|
UC column
|
Upper Critical threshold for the fan speed.
|
|
UNC column
|
Upper Non-Critical threshold for the fan speed.
|
|
LNC column
|
Lower Non-Critical threshold for the fan speed.
|
|
LC column
|
Lower Critical threshold for the fan speed.
|
|
LF column
|
Lower Fatal threshold for the fan speed.
|
|
Temperature Info
|
|
Name column
|
The designated name of the temperature sensor.
|
|
MemberId column
|
A unique identifier for the temperature sensor within its group.
|
|
PhysicalContext column
|
Describes the physical location or context of the temperature sensor.
|
|
State column
|
The current operational state or health status of the temperature sensor.
|
|
Reading(Celsius) column
|
The current temperature reading, measured in Celsius.
|
|
UF column
|
Upper Fatal threshold for the temperature reading.
|
|
UC column
|
Upper Critical threshold for the temperature reading.
|
|
UNC column
|
Upper Non-Critical threshold for the temperature reading.
|
|
LNC column
|
Lower Non-Critical threshold for the temperature reading.
|
|
LC column
|
Lower Critical threshold for the temperature reading.
|
|
LF column
|
Lower Fatal threshold for the temperature reading.
|