Viewing Sensors

This chapter includes the following sections:

Viewing Chassis Sensors

Viewing Power Supply Sensors

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show psu
  3. Server /sensor # show psu-redundancy

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show psu

Displays power supply sensor statistics for the server.

Step 3

Server /sensor # show psu-redundancy

Displays power supply redundancy sensor status for the server.

Example

This example displays power supply sensor statistics:

Server# scope sensor
Server /sensor # show psu
Name          Sensor Status  Reading  Units  Min. Warning Max. Warning  Min. Failure  Max. Failure    
------------  -------------- -------- ------ ------------ ------------  ------------- ------------- 
SU1_PIN       Normal        102      Watts      N/A        882             N/A             1098            
PSU2_PIN       Normal        96       Watts      N/A       882             N/A             1098            
PSU3_PIN       Normal        102      Watts      N/A       882             N/A             1098            
PSU4_PIN       Normal        96       Watts      N/A       882             N/A             1098            
PSU1_POUT      Normal        78       Watts      N/A       798             N/A             996             
PSU2_POUT      Normal        78       Watts      N/A       798             N/A             996             
PSU3_POUT      Normal        84       Watts      N/A       798             N/A             996             
PSU4_POUT      Normal        84       Watts      N/A       798             N/A             996             
POWER_USAGE    Normal        406      Watts      N/A       N/A             N/A             2674            
PSU1_DC_OK     Normal        good                                                                                  
PSU2_DC_OK     Normal        good                                                                                  
PSU3_DC_OK     Normal        good                                                                                  
PSU4_DC_OK     Normal        good                                                                                  
PSU1_AC_OK     Normal        good                                                                                  
PSU2_AC_OK     Normal        good                                                                                  
PSU3_AC_OK     Normal        good                                                                                  
PSU4_AC_OK     Normal        good                                                                                  
PSU1_STATUS    Normal        present                                                                               
PSU2_STATUS    Normal        present                                                                               
PSU3_STATUS    Normal        present                                                                               
PSU4_STATUS    Normal        present 
                                                                             
Server /sensor # show psu-redundancy             
Name                 Reading         Sensor Status        
-------------------- --------------- -------------------- 
PS_RDNDNT_MODE       full            Normal                

Server /sensor #

Viewing Fan Sensors

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show fan [detail]
  3. Server /sensor # show fan-pwm
  4. Server /sensor # show fan-pwm [detail

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show fan [detail]

Displays fan sensor statistics for the server.

Step 3

Server /sensor # show fan-pwm

Displays the PWM %.

Beginning with the release 4.3.5.240021​, Cisco IMC displays an additional sensor property for the fan - Pulse Width Modulation (PWM).

PWM is the absolute measure of the fan on and off duration to control the speed. The ratio of on time compared to off time is known as Duty cycle.

Step 4

Server /sensor # show fan-pwm [detail

Displays the PWM % in detail.

Example

  • This example displays fan sensor statistics:

    Server# scope sensor
    Server /sensor # show fan
    Name            Sensor Status  Reading    Units  Min. Warning  Max. Warning Min. Failure  Max. Failure    
    --------------- -------------  ---------- ------ ------------- ------------ ------------- ------------
    PSU1_FAN_SPEED   Normal         5160       RPM    1118            N/A             946       N/A             
    PSU2_FAN_SPEED   Normal         6106       RPM    1118            N/A             946       N/A             
    PSU3_FAN_SPEED   Normal         5762       RPM    1118            N/A             946       N/A             
    PSU4_FAN_SPEED   Normal         4988       RPM    1118            N/A             946       N/A             
    FAN1_SPEED       Normal         6600       RPM    2040            N/A             1800      N/A             
    FAN2_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A             
    FAN3_SPEED       Normal         6600       RPM    2040            N/A             1800      N/A             
    FAN4_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A             
    FAN5_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A             
    FAN6_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A             
    FAN7_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A             
    FAN8_SPEED       Normal         6660       RPM    2040            N/A             1800      N/A   
    Server /sensor #             
    
  • This example displays the PWM %:

    Server# scope sensor
    Server /sensor # show fan-pwm
    FAN Module           PWM (%)
    -------------------- --------------------
    MOD1_FAN             80
    MOD2_FAN             80
    MOD3_FAN             80
    MOD4_FAN             80
    MOD5_FAN             80
    MOD6_FAN             80
    
  • This example displays the PWM % in detail:

    Server# scope sensor
    Server /sensor # show fan-pwm detail
    FAN Module MOD1_FAN:
        PWM (%): 80
    FAN Module MOD2_FAN:
        PWM (%): 80
    FAN Module MOD3_FAN:
        PWM (%): 80
    FAN Module MOD4_FAN:
        PWM (%): 80
    FAN Module MOD5_FAN:
        PWM (%): 80
    FAN Module MOD6_FAN:
    PWM (%): 80

Viewing Current Sensors

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show current

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show current

Displays current sensor statistics.

Example

This example displays current sensor statistics:

Server# scope sensor
Server /sensor # show current
Name        Sensor Status Reading    Units   Min. Warning Max. Warning Min. Failure Max. Failure 
----------- ------------- ---------- ------- ------------ ------------ ------------ ------------ 
PSU1_IOUT   Normal         6.00       AMP        N/A          78.00        N/A          87.00        
PSU2_IOUT   Normal         6.00       AMP        N/A          78.00        N/A          87.00        
PSU3_IOUT   Normal         7.00       AMP        N/A          78.00        N/A          87.00        
PSU4_IOUT   Normal         7.00       AMP        N/A          78.00        N/A          87.00 

Server /sensor #             

Viewing Voltage Sensors

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show voltage

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show voltage

Displays voltage sensor statistics.

Example

This example displays voltage sensor statistics:

Server# scope sensor
Server /sensor # show voltage
Name             Sensor Status  Reading    Units  Min. Warning Max. Warning Min. Failure Max. Failure 
---------------- -------------- ---------- ------ ------------ ------------ ------------ ------------ 
SIOC_P1V0        Normal         1.000      V          N/A          N/A          0.944        1.064        
SIOC_P1V2        Normal         1.208      V          N/A          N/A          1.128        1.272        
SIOC_P1V5        Normal         1.500      V          N/A          N/A          1.410        1.590        
SIOC_P2V5        Normal         2.478      V          N/A          N/A          2.338        2.646        
SIOC_P3V3        Normal         3.320      V          N/A          N/A          3.100        3.500        
SIOC_P12V_STBY   Normal         12.060     V          N/A          N/A          11.280       12.720       
SIOC_P3V3_STBY   Normal         3.360      V          N/A          N/A          3.140        3.460        
PSU1_VIN         Normal         228.000    V          N/A          N/A          N/A          264.000      
PSU2_VIN         Normal         228.000    V          N/A          N/A          N/A          264.000      
PSU3_VIN         Normal         228.000    V          N/A          N/A          N/A          264.000      
PSU4_VIN         Normal         228.000    V          N/A          N/A          N/A          264.000      
P5V_1            Normal         5.010      V          N/A          N/A          4.500        5.640        
P5V_2            Normal         5.010      V          N/A          N/A          4.500        5.640        
P5V_3            Normal         5.010      V          N/A          N/A          4.500        5.640        
P5V_4            Normal         5.010      V          N/A          N/A          4.500        5.640        
P0V9_EXP1_VCORE  Normal         0.872      V          N/A          N/A          0.836        0.976        
P0V9_EXP2_VCORE  Normal         0.872      V          N/A          N/A          0.836        0.976        
P0V9_EXP1_AVD    Normal         0.888      V          N/A          N/A          0.836        0.976        
P0V9_EXP2_AVD    Normal         0.904      V          N/A          N/A          0.836        0.976        
PSU1_VOUT        Normal         12.000     V          N/A          N/A          N/A          12.600       
PSU2_VOUT        Normal         12.000     V          N/A          N/A          N/A          12.600       
PSU3_VOUT        Normal         12.000     V          N/A          N/A          N/A          12.600       
PSU4_VOUT        Normal         12.000     V          N/A      
Server /sensor #             

Viewing Temperature Sensors

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show temperature

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show temperature

Displays temperature sensor statistics.

Example

This example displays temperature sensor statistics:

Server# scope sensor
Server /sensor # show temperature
Name               Sensor Status  Reading Units    Min. Warning Max. Warning Min. Failure Max. Failure 
------------------ -------------- ------- -------- ------------ ------------ ------------ ------------ 
SIOC1_BACK_TEMP    Normal         37.0       C          N/A          70.0         N/A          80.0         
SIOC1_FRONT_TEMP   Normal         42.0       C          N/A          70.0         N/A          80.0         
SIOC1_MID_TEMP     Normal         41.0       C          N/A          70.0         N/A          80.0         
SIOC1_VIC_TEMP     Normal         44.0       C          N/A          70.0         N/A          80.0         
SIOC2_VIC_TEMP     Normal         44.0       C          N/A          70.0         N/A          80.0         
MOBO_R_BOT_TEMP    Normal         30.0       C          N/A          70.0         N/A          80.0         
MOBO_L_BOT_TEMP    Normal         31.0       C          N/A          70.0         N/A          80.0         
MOBO_R_MID_TEMP    Normal         25.0       C          N/A          50.0         N/A          55.0         
MOBO_R_IN_TEMP     Normal         24.0       C          N/A          50.0         N/A          55.0         
MOBO_L_IN_TEMP     Normal         26.0       C          N/A          50.0         N/A          55.0         
MOBO_L_MID_TEMP    Normal         26.0       C          N/A          50.0         N/A          55.0         
MOBO_R_OUT_TEMP    Normal         29.0       C          N/A          47.0         N/A          52.0         
MOBO_L_OUT_TEMP    Normal         29.0       C          N/A          46.0         N/A          51.0         
PSU1_TEMP          Normal         24.0       C          N/A          55.0         N/A          60.0         
PSU2_TEMP          Normal         27.0       C          N/A          55.0         N/A          60.0         
PSU3_TEMP          Normal         27.0       C          N/A          55.0         N/A          60.0         
PSU4_TEMP          Normal         25.0       C          N/A          55.0         N/A          60.0         
SIOC1_CMC_TEMP     Normal         51.0       C          N/A          75.0         N/A          85.0         
MOBO_R_EXP_TEMP    Normal         37.0       C          N/A          80.0         N/A          90.0         
MOBO_L_EXP_TEMP    Normal         40.0       C          N/A          80.0         N/A          90.0         
SIOC2_BACK_TEMP    Normal         36.0       C          N/A          70.0         N/A          80.0         
SIOC2_FRONT_TEMP   Normal         36.0       C          N/A          70.0         N/A          80.0         
SIOC2_MID_TEMP     Normal         36.0       C          N/A          70.0         N/A          80.0         
SIOC2_CMC_TEMP     Normal         36.0       C          N/A          75.0         N/A          85.0    
Server /sensor #             

Viewing LED Sensor

SUMMARY STEPS

  1. Server# scope sensor
  2. Server /sensor # show led

DETAILED STEPS

  Command or Action Purpose

Step 1

Server# scope sensor

Enters sensor command mode.

Step 2

Server /sensor # show led

Displays LED sensor statistics.

Example

This example displays LED sensor statistics:

Server# scope sensor
Server /sensor # show led
LED Name                  LED State  LED Color 
------------------------- ---------- -------- 
LED_FAN12_FAULT           OFF        AMBER    
LED_FAN34_FAULT           OFF        AMBER    
LED_FAN56_FAULT           OFF        AMBER    
LED_FAN78_FAULT           OFF        AMBER    
CHS_FP_LED_ID             OFF        BLUE     
LED_HLTH_STATUS           ON         GREEN    
LED_PSU_STATUS            ON         GREEN    
LED_TEMP_STATUS           ON         GREEN    
LED_FAN_STATUS            ON         GREEN    
SERVER1_FP_ID_LED         OFF        BLUE     
SERVER2_FP_ID_LED         OFF        BLUE     
OVERALL_DIMM_STATUS       ON         GREEN 
Server /sensor #             

Viewing Server Sensors

Viewing Storage Sensors

SUMMARY STEPS

  1. Server # scope server {1 | 2}
  2. Server /server # scope sensor
  3. Server /server /sensor #show hdd

DETAILED STEPS

  Command or Action Purpose

Step 1

Server # scope server {1 | 2}

Enters server command mode of server 1 or 2.

Step 2

Server /server # scope sensor

Enters sensor command.

Step 3

Server /server /sensor #show hdd

Displays the storage sensors for the server.

Example

This example displays the storage sensors for the server:

Server# scope server 1 
Server /server #scope sensor
Server /server /sensor #show hdd
Name                 Status               
-------------------- -------------------- 
SSD1_PRS             inserted             
SSD2_PRS             inserted      

 Server server /sensor #  

Viewing Current Sensors

SUMMARY STEPS

  1. Server # scope server {1 | 2}
  2. Server /server # scope sensor
  3. Server /server /sensor #show current

DETAILED STEPS

  Command or Action Purpose

Step 1

Server # scope server {1 | 2}

Enters server command mode of server 1 or 2.

Step 2

Server /server # scope sensor

Enters sensor command.

Step 3

Server /server /sensor #show current

Displays the current sensors for the server.

Example

This example displays the current sensors for the server:

Server# scope server 1 
Server /server #scope sensor
Server /server /sensor #show current
Name           Sensor Status  Reading  Units   Min. Warning Max. Warning Min. Failure Max. Failure 
-------------- -------------- -------- ------- ------------ ------------ ------------ ------------ 
P12V_CUR_SENS  Normal         5.84       AMP        N/A          N/A          N/A          56.90  
Server server /sensor #  

Viewing LED Sensors

SUMMARY STEPS

  1. Server # scope server {1 | 2}
  2. Server /server # scope sensor
  3. Server /server /sensor #show led

DETAILED STEPS

  Command or Action Purpose

Step 1

Server # scope server {1 | 2}

Enters server command mode of server 1 or 2.

Step 2

Server /server # scope sensor

Enters sensor command.

Step 3

Server /server /sensor #show led

Displays the LED sensors for the server.

Example

This example displays the LED sensors for the server:

Server# scope server 1 
Server /server #scope sensor
Server /server /sensor #show led
LED Name                  LED State  LED Color 
------------------------- ---------- -------- 
FP_ID_LED                 FAST BLINK BLUE     
P1_DIMM_A1_LED            OFF        AMBER    
P1_DIMM_A2_LED            OFF        AMBER    
P1_DIMM_B1_LED            OFF        AMBER    
P1_DIMM_B2_LED            OFF        AMBER    
P1_DIMM_C1_LED            OFF        AMBER    
P1_DIMM_C2_LED            OFF        AMBER    
P1_DIMM_D1_LED            OFF        AMBER    
P1_DIMM_D2_LED            OFF        AMBER    
P2_DIMM_E1_LED            OFF        AMBER    
P2_DIMM_E2_LED            OFF        AMBER    
P2_DIMM_F1_LED            OFF        AMBER    
P2_DIMM_F2_LED            OFF        AMBER    
P2_DIMM_G1_LED            OFF        AMBER    
P2_DIMM_G2_LED            OFF        AMBER    
P2_DIMM_H1_LED            OFF        AMBER    
P2_DIMM_H2_LED            OFF        AMBER    
LED_HLTH_STATUS           ON         GREEN    
LED_TEMP_STATUS           ON         GREEN    
OVERALL_DIMM_STATUS       ON         GREEN  
 
 Server server /sensor #  

Viewing Temperature Sensors

SUMMARY STEPS

  1. Server # scope server {1 | 2}
  2. Server /server # scope sensor
  3. Server /server /sensor #show temperature

DETAILED STEPS

  Command or Action Purpose

Step 1

Server # scope server {1 | 2}

Enters server command mode of server 1 or 2.

Step 2

Server /server # scope sensor

Enters sensor command.

Step 3

Server /server /sensor #show temperature

Displays the temperature sensors for the server.

Example

This example displays the temperature sensors for the server:

Server# scope server 1 
Server /server #scope sensor
Server /server /sensor #show temperature
Name             Sensor Status  Reading  Units    Min. Warning Max. Warning Min. Failure Max. Failure 
---------------- -------------- -------- -------- ------------ ------------ ------------ ------------ 
TEMP_SENS_FRONT  Normal         24.0       C          N/A          60.0         N/A          70.0         
TEMP_SENS_REAR   Normal         25.0       C          N/A          80.0         N/A          85.0         
P1_TEMP_SENS     Normal         21.0       C          N/A          74.0         N/A          79.0         
P2_TEMP_SENS     Normal         23.5       C          N/A          74.0         N/A          79.0         
DDR3_P1_A1_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_A2_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_B1_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_B2_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_C1_TEMP  Normal         24.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_C2_TEMP  Normal         24.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_D1_TEMP  Normal         24.0       C          N/A          65.0         N/A          85.0         
DDR3_P1_D2_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P2_E1_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P2_E2_TEMP  Normal         23.0       C          N/A          65.0         N/A          85.0         
DDR3_P2_F1_TEMP  Normal         22.0       C          N/A          65.0         N/A          85.0     

Server server /sensor #  

Viewing Voltage Sensors

SUMMARY STEPS

  1. Server # scope server {1 | 2}
  2. Server /server # scope sensor
  3. Server /server /sensor #show voltage

DETAILED STEPS

  Command or Action Purpose

Step 1

Server # scope server {1 | 2}

Enters server command mode of server 1 or 2.

Step 2

Server /server # scope sensor

Enters sensor command.

Step 3

Server /server /sensor #show voltage

Displays the voltage sensors for the server.

Example

This example displays the voltage sensors for the server:

Server# scope server 1 
Server /server #scope sensor
Server /server /sensor #show voltage
Name            Sensor Status  Reading  Units    Min. Warning Max. Warning Min. Failure Max. Failure 
--------------- -------------- -------- -------- ------------ ------------ ------------ ------------ 
P3V_BAT_SCALED   Normal         2.973      V          N/A          N/A          2.154        3.418        
P5V_STBY         Normal         4.909      V          N/A          N/A          4.555        5.452        
P3V3_STBY        Normal         3.302      V          N/A          N/A          3.018        3.602        
P1V1_SSB_STBY    Normal         1.088      V          N/A          N/A          1.000        1.205        
P1V8_STBY        Normal         1.784      V          N/A          N/A          1.627        1.980        
P1V0_STBY        Normal         0.990      V          N/A          N/A          0.911        1.088        
P1V5_STBY        Normal         1.490      V          N/A          N/A          1.372        1.637        
P0V75_STBY       Normal         0.725      V          N/A          N/A          0.686        0.823        
P2V5_STBY        Normal         2.484      V          N/A          N/A          2.279        2.734        
P12V             Normal         11.977     V          N/A          N/A          11.210       12.803       
P5V              Normal         5.031      V          N/A          N/A          4.680        5.335        
P3V3             Normal         3.276      V          N/A          N/A          3.089        3.526        
P1V5_SSB         Normal         1.482      V          N/A          N/A          1.412        1.607        
P1V1_SSB         Normal         1.084      V          N/A          N/A          1.037        1.178        
PVTT_P1          Normal         0.991      V          N/A          N/A          0.944        1.061        
PVTT_P2          Normal         0.975      V          N/A          N/A          0.944        1.061        
PVSA_P1          Normal         0.959      V          N/A          N/A          0.593        1.170    

Server server /sensor #