Viewing Power Supply Sensors
Procedure
Command or Action | Purpose | |
---|---|---|
Step 1 |
Server# scope sensor |
Enters sensor command mode. |
Step 2 |
Server /sensor # show psu |
Displays power supply sensor statistics for the server. |
Step 3 |
Server /sensor # show psu-redundancy |
Displays power supply redundancy sensor status for the server. |
Example
This example displays power supply sensor statistics:
Server# scope sensor
Server /sensor # show psu
Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure
------------ -------------- -------- ------ ------------ ------------ ------------- -------------
SU1_PIN Normal 102 Watts N/A 882 N/A 1098
PSU2_PIN Normal 96 Watts N/A 882 N/A 1098
PSU3_PIN Normal 102 Watts N/A 882 N/A 1098
PSU4_PIN Normal 96 Watts N/A 882 N/A 1098
PSU1_POUT Normal 78 Watts N/A 798 N/A 996
PSU2_POUT Normal 78 Watts N/A 798 N/A 996
PSU3_POUT Normal 84 Watts N/A 798 N/A 996
PSU4_POUT Normal 84 Watts N/A 798 N/A 996
POWER_USAGE Normal 406 Watts N/A N/A N/A 2674
PSU1_DC_OK Normal good
PSU2_DC_OK Normal good
PSU3_DC_OK Normal good
PSU4_DC_OK Normal good
PSU1_AC_OK Normal good
PSU2_AC_OK Normal good
PSU3_AC_OK Normal good
PSU4_AC_OK Normal good
PSU1_STATUS Normal present
PSU2_STATUS Normal present
PSU3_STATUS Normal present
PSU4_STATUS Normal present
Server /sensor # show psu-redundancy
Name Reading Sensor Status
-------------------- --------------- --------------------
PS_RDNDNT_MODE full Normal
Server /sensor #