Server Specifications
This appendix lists the technical specifications for the Cisco UCS C460 server and includes the following sections:
Physical Specifications
Table A-1 lists the physical specifications for the server.
Table A-1 Physical Specifications
|
|
Height |
6.8 in (174 mm) |
Width |
16.7 in (424 mm) |
Depth |
27.7 in (704 mm) |
Weight |
110.23 lbs (50 kg) |
Caution
The Cisco UCS C460 server weighs approximately 110 pounds, or 50 kilograms, when fully loaded with components. We recommend that you use a minimum of two people when lifting the server. Attempting to lift the Cisco UCS C460 server alone could result in personal injury or equipment damage.
Environmental Specifications
Table A-2 lists the environmental specifications for the server.
Table A-2 Environmental Specifications
|
|
Temperature, operating |
10ºC to 35ºC (50ºF to 95ºF) |
Temperature, non-operating |
-40ºC to 70ºC (-40ºF to 158ºF) |
Humidity, non-operating |
95%, non-condensing at temperatures of 25ºC (77ºF) to 30ºC (86ºF) |
Altitude |
-30m to 1500m (-100ft to 5000ft) |
Power Specifications
Table A-3 lists the specifications for each power supply.
Table A-3 Power Supply Specifications
|
|
AC input voltage |
115 to 230 VAC nominal (Range: 90 to 264 VAC) |
AC input frequency |
50 to 60 Hz nominal (Range: 47 to 63 Hz) |
Maximum AC-input current |
10A |
Maximum output power for each power supply |
850W (up to four power supplies can be installed) |
Power supply output voltage |
Main power: 12 VDC Standby power: 3.3 VDC |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/